55. Research on Fungal Microorganisms Growth Under Various Thermal Conditions

Authors : Yang Lv, Bailin Fu, Wenjie Yuan, An Xie, Jinmu Huang

Published in: Proceedings of the 8th International Symposium on Heating, Ventilation and Air Conditioning

Publisher: Springer Berlin Heidelberg

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Indoor air quality has a great impact on our health, and there are many reasons contributing to the pollution of indoor air. At present, people have widely concerned about air-conditioning system, which is regarded as potential microbial pollution sources. The study is about separation and identification of fungal microorganisms on the surface of the central air-conditioning system filters, and then doing research on the colonies and mycelium grown and reproduce regular of fungal microorganisms in different thermal environment, which aim to lay the groundwork of effective air microbial contamination solved by thermal methods. This study has shown that Penicillium spp and Cladosporium spp are dominant fungi, and the number of CFUs is 600 and 140 cfu/cm², respectively. No matter constant or variable temperature conditions, the reproduce rate of Penicillium is faster than A. glaucus and the relationship between colony diameter and time is liner relation. Through these constant and variable experiments, it is found that variable temperature does obvious restrain on Penicillium spp, while A. glaucus has the same tendency.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Bluyssen PM, Cox C, Seppanen O et al (2003) Why, when, how do HVAC-systems pollute the indoor environment and what to do about it? Environ 38(2):209–225 Bluyssen PM, Cox C, Seppanen O et al (2003) Why, when, how do HVAC-systems pollute the indoor environment and what to do about it? Environ 38(2):209–225
2.
go back to reference Hou J (2009) Field and analysis for microbial contamination and characteristics of ventilated systems in air conditioning. Master thesis, Xi An University of Architecture and Technology, Xi An, China (In Chinese) Hou J (2009) Field and analysis for microbial contamination and characteristics of ventilated systems in air conditioning. Master thesis, Xi An University of Architecture and Technology, Xi An, China (In Chinese)
3.
go back to reference Chen F, Zhao B, Yang X (2009) Investigation and review of microbial pollution in air conditioning systems of public buildings. Heating ventilating and air conditioning (39):50–56 (In Chinese) Chen F, Zhao B, Yang X (2009) Investigation and review of microbial pollution in air conditioning systems of public buildings. Heating ventilating and air conditioning (39):50–56 (In Chinese)
4.
go back to reference Lu Z, Jang J, Cao D et al (2007) Testing and analysis for microbes and particles in central air conditioning systems of public buildings. J Heating ventilating and air conditioning 37:103–107 (In Chinese) Lu Z, Jang J, Cao D et al (2007) Testing and analysis for microbes and particles in central air conditioning systems of public buildings. J Heating ventilating and air conditioning 37:103–107 (In Chinese)
5.
go back to reference Li A, Yao L, Hou J (2010) Field test and analysis of microbial contamination in central air conditioning systems. Heating ventilating and air conditioning 40:121–125 (In Chinese) Li A, Yao L, Hou J (2010) Field test and analysis of microbial contamination in central air conditioning systems. Heating ventilating and air conditioning 40:121–125 (In Chinese)
6.
go back to reference Zhang J, Guo X (2005) Living environment and health. Chemical Industry Press, Beijing (In Chinese) Zhang J, Guo X (2005) Living environment and health. Chemical Industry Press, Beijing (In Chinese)
7.
go back to reference Zhao A, Guo Y, Pan X (2009) Research advance in indoor microbial contamination and health impact. J Environ Health (26):82–84 (In Chinese) Zhao A, Guo Y, Pan X (2009) Research advance in indoor microbial contamination and health impact. J Environ Health (26):82–84 (In Chinese)
8.
go back to reference Somers CM, McCarry BE, Malek F et al (2004) Reduction of particulate air pollution lowers the risk of heritable mutations in mice. Science 304:1008–1010CrossRef Somers CM, McCarry BE, Malek F et al (2004) Reduction of particulate air pollution lowers the risk of heritable mutations in mice. Science 304:1008–1010CrossRef
9.
go back to reference Gorny RL, Reponen T, Willeke K et al (2002) Fungal fragments as indoor air biocontaminants. Appl Environ Microbial (68):3522 Gorny RL, Reponen T, Willeke K et al (2002) Fungal fragments as indoor air biocontaminants. Appl Environ Microbial (68):3522
10.
go back to reference Wei J (1979) Fungal identification manual. Shanghai Science and Technology Press, Shanghai (In Chinese) Wei J (1979) Fungal identification manual. Shanghai Science and Technology Press, Shanghai (In Chinese)
Metadata
Title
Research on Fungal Microorganisms Growth Under Various Thermal Conditions
Authors
Yang Lv
Bailin Fu
Wenjie Yuan
An Xie
Jinmu Huang
Copyright Year
2014
Publisher
Springer Berlin Heidelberg
DOI
https://doi.org/10.1007/978-3-642-39584-0_55