Skip to main content
Top
Published in: International Journal of Steel Structures 2/2020

01-01-2020

Structural Performance of Welded Built-Up Mega Composite Columns Subject to Compressive Force and Moment

Authors: Sun-Hee Kim, Sung-Mo Choi

Published in: International Journal of Steel Structures | Issue 2/2020

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

The width thickness ratio of a concrete-filled steel tube column is limited in order to prevent the local buckling of the tube. Determined by column width and steel tube thickness, width-thickness ratio decides whether the cross-section is compact, non-compact or slender. Different compressive strength formulas are applied depending on the type of the cross-section. This study suggests the shape of binding frames which are placed at a constant distance inside the steel tube of a mega column having large cross-sections to improve the composite effect and confinement effect. Structural tests are conducted on 9 welded built-up and generic CFT columns with different steel thicknesses to evaluate their structural performance under compressive force and moment applied simultaneously. The maximum load of the welded built-up specimens with compact, non-compact and slender cross-sections is approximately 38%, 30% and 20% higher when compared with their generic CFT counterparts. While the effective stiffness of the members of concrete-filled composite columns is calculated by one formula, the difference among the specimens is greater than 10% depending on the width-thickness ratio. Therefore, it is deemed that effective stiffness needs to be categorized depending on the width-thickness ratio as in the case of compressive strength and bending strength.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
go back to reference ACI 318 (2014) Building Code Requirements for Structural Concrete and Commentary, American Concrete Institute, USA. ACI 318 (2014) Building Code Requirements for Structural Concrete and Commentary, American Concrete Institute, USA.
go back to reference AIK (2016) Korea Building Codes(KBC2016), AIK, Korea (in Korean). AIK (2016) Korea Building Codes(KBC2016), AIK, Korea (in Korean).
go back to reference American Institute of Steel Construction (2016). Specification for Structural Steel Buildings, AISC 360–16, AISC, Chicago. American Institute of Steel Construction (2016). Specification for Structural Steel Buildings, AISC 360–16, AISC, Chicago.
go back to reference Eurocode 2. (2004). Design of Concrete Structures-Part 1-1: General Rules and Rules for Buildings, CEN, Belgium. Eurocode 2. (2004). Design of Concrete Structures-Part 1-1: General Rules and Rules for Buildings, CEN, Belgium.
go back to reference Eurocode 3. (2005). Design of Steel Structures-Part 1-1: General Rules and Rules for Buildings, CEN, Belgium. Eurocode 3. (2005). Design of Steel Structures-Part 1-1: General Rules and Rules for Buildings, CEN, Belgium.
go back to reference Eurocode 4. (2004). Design of Composite Steel and Concrete Structures-Part 1-1: General Rules and Rules for Buildings, CEN, Belgium. Eurocode 4. (2004). Design of Composite Steel and Concrete Structures-Part 1-1: General Rules and Rules for Buildings, CEN, Belgium.
go back to reference Kennedy, S. J. (1984). End connection effects on the strength of concrete filled HSS beam columns, M.Sc. thesis, Department of Civil Engineering, Edmonton, Alberta, Canada. Kennedy, S. J. (1984). End connection effects on the strength of concrete filled HSS beam columns, M.Sc. thesis, Department of Civil Engineering, Edmonton, Alberta, Canada.
go back to reference Kim, S. H., Yom, K. S., & Choi, S. M. (2013). A study on the load carrying capacity and deformation capacity of the internal anchors welded cold formed concrete filled columns. Journal of Korean Society of Steel Construction,25(4), 347–357. (in Korean).CrossRef Kim, S. H., Yom, K. S., & Choi, S. M. (2013). A study on the load carrying capacity and deformation capacity of the internal anchors welded cold formed concrete filled columns. Journal of Korean Society of Steel Construction,25(4), 347–357. (in Korean).CrossRef
go back to reference Korea Building Code (2016) Composite construction design manual, Korean Society of Steel Construction. Korea Building Code (2016) Composite construction design manual, Korean Society of Steel Construction.
go back to reference Lee, S. H., et al. (2009). Water pressure test and analysis for welding thickness decision for new cold-formed type concrete filled tubular square column. Journal of Korean Society of Steel Construction, KSSC,21(5), 515–525. (in Korean). Lee, S. H., et al. (2009). Water pressure test and analysis for welding thickness decision for new cold-formed type concrete filled tubular square column. Journal of Korean Society of Steel Construction, KSSC,21(5), 515–525. (in Korean).
go back to reference Marshall, P. W. (1992). Design of welded tubular connections: Basis and use of AWS code provisions. Amsterdam: Elsevier. Marshall, P. W. (1992). Design of welded tubular connections: Basis and use of AWS code provisions. Amsterdam: Elsevier.
go back to reference Uy, B., & Das, S. (1997). Wet concrete loading of thin-walled steel box columns during the construction of a tall building. Journal of Constructional Steel Research,42(2), 95–119.CrossRef Uy, B., & Das, S. (1997). Wet concrete loading of thin-walled steel box columns during the construction of a tall building. Journal of Constructional Steel Research,42(2), 95–119.CrossRef
go back to reference Uy, B., & Das, S. (1999). Bracing of thin walled steel box columns during pumping of wet concrete in tall buildings. Thin-Walled Structures,33(2), 127–154.CrossRef Uy, B., & Das, S. (1999). Bracing of thin walled steel box columns during pumping of wet concrete in tall buildings. Thin-Walled Structures,33(2), 127–154.CrossRef
Metadata
Title
Structural Performance of Welded Built-Up Mega Composite Columns Subject to Compressive Force and Moment
Authors
Sun-Hee Kim
Sung-Mo Choi
Publication date
01-01-2020
Publisher
Korean Society of Steel Construction
Published in
International Journal of Steel Structures / Issue 2/2020
Print ISSN: 1598-2351
Electronic ISSN: 2093-6311
DOI
https://doi.org/10.1007/s13296-019-00305-4

Other articles of this Issue 2/2020

International Journal of Steel Structures 2/2020 Go to the issue

Premium Partners