Skip to main content
Top

2018 | OriginalPaper | Chapter

Study About UI Design Optimization of TNPS MMI

Author : Jie Xu

Published in: Nuclear Power Plants: Innovative Technologies for Instrumentation and Control Systems

Publisher: Springer Singapore

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Tianwan Nuclear Power Station Phase I is the first nuclear power station that adopts full digital instrumentation and control system in China. Due to the fact that there is no reference station in the complete sense for the original design, most of the design is actually new. This leads to plenty of exploration and study in terms of how the Man Machine Interface satisfies most effectively the requirements of human factors engineering. To certain extent, it affirms the utilization of digital I&C system, and proves the effectiveness of MMI, as the two units of Phase I have achieved good operation performance, economic benefits since commercial operation. So Phase II based on the successful construction and good practice of Phase I, implements the strategy of ‘Copy plus Improvements’. I&C System still adopts full digital I&C system. MMI is basically the same, and assimilating the experiences in aspects of design, commissioning and operation of Phase I. This essay introduces the general structure of computerized MMI in Phase I, studies and summaries the principles of display design, discourses how to realize these principles during engineering. Through aforementioned studies, this essay analyzes the display design advantages and disadvantages of Phase I, introduces some implemented measures in Phase II.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Advanced Light Water Reactor Utility Requirements Document (URD), vol. 2, Chap. 10, Revision 7 Advanced Light Water Reactor Utility Requirements Document (URD), vol. 2, Chap. 10, Revision 7
2.
go back to reference International Electrotechnical Commission. IEC 73: Basic and safety principles for man-machine interface, marking and identification - Coding principles for indication devices and actuators: 10 (1996) International Electrotechnical Commission. IEC 73: Basic and safety principles for man-machine interface, marking and identification - Coding principles for indication devices and actuators: 10 (1996)
3.
go back to reference International Electrotechnical Commission. IEC 964: Design for control rooms of nuclear power plants: 03 (1989) International Electrotechnical Commission. IEC 964: Design for control rooms of nuclear power plants: 03 (1989)
4.
go back to reference SIEMENS Work Report. General description for the arrangement of video displays of the OM system for Tianwan NPP (2003) SIEMENS Work Report. General description for the arrangement of video displays of the OM system for Tianwan NPP (2003)
5.
go back to reference International Electrotechnical Commission. IEC 61772: Nuclear Power Plants - Control Rooms - Application of Visual Display Units (VDUs) (2009) International Electrotechnical Commission. IEC 61772: Nuclear Power Plants - Control Rooms - Application of Visual Display Units (VDUs) (2009)
6.
go back to reference Consortium technical report. HFE program for control room and HMI design (2013) Consortium technical report. HFE program for control room and HMI design (2013)
Metadata
Title
Study About UI Design Optimization of TNPS MMI
Author
Jie Xu
Copyright Year
2018
Publisher
Springer Singapore
DOI
https://doi.org/10.1007/978-981-10-7416-5_6