Skip to main content
Top

2014 | OriginalPaper | Chapter

T 2-Relaxometry for Myelin Water Fraction Extraction Using Wald Distribution and Extended Phase Graph

Authors : Alireza Akhondi-Asl, Onur Afacan, Robert V. Mulkern, Simon K. Warfield

Published in: Medical Image Computing and Computer-Assisted Intervention – MICCAI 2014

Publisher: Springer International Publishing

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Quantitative assessment of myelin density in the white matter is an emerging tool for neurodegenerative disease related studies such as multiple sclerosis and Schizophrenia. For the last two decades,

T

2

relaxometry based on multi-exponential fitting to a single slice multi-echo sequence has been the most common MRI technique for myelin water fraction (MWF) mapping, where the short

T

2

is associated with myelin water. However, modeling the spectrum of the relaxations as the sum of large number of impulse functions with unknown amplitudes makes the accuracy and robustness of the estimated MWF’s questionable. In this paper, we introduce a novel model with small number of parameters to simultaneously characterize transverse relaxation rate spectrum and

B

1

inhomogeneity at each voxel. We use mixture of three Wald distributions with unknown mixture weights, mean and shape parameters to represent the distribution of the relative amount of water in between myelin sheets, tissue water, and cerebrospinal fluid. The parameters of the model are estimated using the variable projection method and are used to extract the MWF at each voxel. In addition, we use Extended Phase Graph (EPG) method to compensate for the stimulated echoes caused by

B

1

inhomogeneity. To validate our model, synthetic and real brain experiments were conducted where we have compared our novel algorithm with the non-negative least squares (NNLS) as the state-of-the-art technique in the literature. Our results indicate that we can estimate MWF map with substantially higher accuracy as compared to the NNLS method.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Metadata
Title
T 2-Relaxometry for Myelin Water Fraction Extraction Using Wald Distribution and Extended Phase Graph
Authors
Alireza Akhondi-Asl
Onur Afacan
Robert V. Mulkern
Simon K. Warfield
Copyright Year
2014
Publisher
Springer International Publishing
DOI
https://doi.org/10.1007/978-3-319-10443-0_19

Premium Partner