Abstract

Using a data set with approximately 4 years of elapsed time between the earliest and most recent images of an iris (23 subjects, 46 irises, 6,797 images), we investigate template aging for iris biometrics. We compare the match and non-match distributions for short-time-lapse image pairs, acquired with no more than 120 days of time lapse between them, to the distributions for long-time-lapse image pairs, with at least 1,200 days of time lapse. We find no substantial difference in the non-match, or impostor, distribution between the short-time-lapse and the long-time-lapse data. We do find a difference in the match, or authentic, distributions. For the image dataset and iris biometric systems used in this work, the false reject rate increases by about 50 % or greater for the long-time-lapse data relative to the short-time-lapse data. The magnitude of the increase in the false reject rate varies with changes in the decision threshold, and with different matching algorithms. Our results demonstrate that iris biometrics is subject to a template aging effect.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference P. Artal, Aging effects on the optics of the eye, in Age-Related Changes of the Human Eye (Springer, 2008), pp. 35–44 P. Artal, Aging effects on the optics of the eye, in Age-Related Changes of the Human Eye (Springer, 2008), pp. 35–44
2.
go back to reference D. Atchison et al., Age-related changes in optical and biometric characteristics of emmetropic eyes. J. Vis. 8(4), 1–20 (2008)CrossRef D. Atchison et al., Age-related changes in optical and biometric characteristics of emmetropic eyes. J. Vis. 8(4), 1–20 (2008)CrossRef
3.
go back to reference S. Baker, K. Bowyer, P. Flynn, Empirical evidence for correct iris match score degradation with increased time-lapse between gallery and probe matches, in Proceedings of the Third International Conference on Biometrics, 2009, pp. 1170–1179 S. Baker, K. Bowyer, P. Flynn, Empirical evidence for correct iris match score degradation with increased time-lapse between gallery and probe matches, in Proceedings of the Third International Conference on Biometrics, 2009, pp. 1170–1179
4.
go back to reference S. Baker et al., Degradation of iris recognition performance due to non-cosmetic prescription contact lenses. Comput. Vis. Image Underst. 114(9), 1030–1044 (2010)CrossRef S. Baker et al., Degradation of iris recognition performance due to non-cosmetic prescription contact lenses. Comput. Vis. Image Underst. 114(9), 1030–1044 (2010)CrossRef
5.
go back to reference L. Bito, A. Matheny, O.C.K. Cruickshanksa, D. Nondahl, Eye color changes past early childhood. Arch. Ophthalmol. 115, 659–663 (1997) L. Bito, A. Matheny, O.C.K. Cruickshanksa, D. Nondahl, Eye color changes past early childhood. Arch. Ophthalmol. 115, 659–663 (1997)
6.
go back to reference J. Carls et al., Biometric enhancements: Template aging error score analysis, in 8th IEEE International Conference on Automatic Face and Gesture Recognition, 2008, pp. 1–8 J. Carls et al., Biometric enhancements: Template aging error score analysis, in 8th IEEE International Conference on Automatic Face and Gesture Recognition, 2008, pp. 1–8
7.
go back to reference J. Daugman, IEEE Trans. Circuits Syst. Video Technol., 21–30 (2004) J. Daugman, IEEE Trans. Circuits Syst. Video Technol., 21–30 (2004)
8.
go back to reference J. Daugman, New methods in iris recognition. IEEE Trans. Syst. Man Cybern. 37(5), 1167–1175 (2007)CrossRef J. Daugman, New methods in iris recognition. IEEE Trans. Syst. Man Cybern. 37(5), 1167–1175 (2007)CrossRef
9.
go back to reference S.P. Fenker, Experimental evidence of a template aging effect in iris biometrics (2011) S.P. Fenker, Experimental evidence of a template aging effect in iris biometrics (2011)
10.
go back to reference L. Flom, A. Safir, Iris recognition systems. U.S. Patent No. 4641394 (1987) L. Flom, A. Safir, Iris recognition systems. U.S. Patent No. 4641394 (1987)
11.
go back to reference L. Flom, A. Safir, D. Hu, Photobiology of the uveal tract, in Photobiological Sciences Online (1987) L. Flom, A. Safir, D. Hu, Photobiology of the uveal tract, in Photobiological Sciences Online (1987)
12.
go back to reference K. Hollingsworth, K.W. Bowyer, P.J. Flynn, Pupil dilation degrades iris biometric performance. Comput. Vis. Image Underst. (2009) K. Hollingsworth, K.W. Bowyer, P.J. Flynn, Pupil dilation degrades iris biometric performance. Comput. Vis. Image Underst. (2009)
13.
go back to reference K. Hollingsworth, K.W. Bowyer, P.J. Flynn, Similarity of iris texture between identical twins, in Computer Vision and Pattern Recognition Biometrics Workshop, June 2010 K. Hollingsworth, K.W. Bowyer, P.J. Flynn, Similarity of iris texture between identical twins, in Computer Vision and Pattern Recognition Biometrics Workshop, June 2010
14.
go back to reference A. Lanitis, A survey of the effects of aging on biometric identity verification. Int. J. Biometr. 2(1), 34–62 (2010)CrossRef A. Lanitis, A survey of the effects of aging on biometric identity verification. Int. J. Biometr. 2(1), 34–62 (2010)CrossRef
16.
go back to reference X. Liu, K.W. Bowyer, P. Flynn, Experiments with an improved iris segmentation algorithm, in Proceedings of the Fourth IEEE Workshop on Automatic Identification Technologies, Oct 2005, pp. 118–123 X. Liu, K.W. Bowyer, P. Flynn, Experiments with an improved iris segmentation algorithm, in Proceedings of the Fourth IEEE Workshop on Automatic Identification Technologies, Oct 2005, pp. 118–123
17.
go back to reference K. Miyazawa, et al., IEEE Trans. Pattern Anal. Mach. Intell. 30, 1741–1756 (2008) K. Miyazawa, et al., IEEE Trans. Pattern Anal. Mach. Intell. 30, 1741–1756 (2008)
18.
go back to reference K. Miyazawa et al., Aging and the Eye (2008) K. Miyazawa et al., Aging and the Eye (2008)
19.
go back to reference D. Monro, S. Rakshit, D. Zhang, DCT-based iris recognition. IEEE Trans. Pattern Anal. Mach. Intell. 4(29), 586–595 (2007)CrossRef D. Monro, S. Rakshit, D. Zhang, DCT-based iris recognition. IEEE Trans. Pattern Anal. Mach. Intell. 4(29), 586–595 (2007)CrossRef
20.
go back to reference D. Monro, S. Rakshit, D. Zhang, Iris Challenge Evaluation (2006) D. Monro, S. Rakshit, D. Zhang, Iris Challenge Evaluation (2006)
22.
go back to reference P. Phillips et al., Face Recognition Vendor Test 2002: Overview and Summary (2000) P. Phillips et al., Face Recognition Vendor Test 2002: Overview and Summary (2000)
23.
go back to reference P. Phillips et al., The iris challenge evaluation 2005, in Proceedings of the Second IEEE Conference on Biometrics: Theory, Applications, and Systems (2008) P. Phillips et al., The iris challenge evaluation 2005, in Proceedings of the Second IEEE Conference on Biometrics: Theory, Applications, and Systems (2008)
24.
go back to reference J. Ryu, J. Jang, H. Kim, Analysis of effect of fingerprint sample quality in template aging, in NIST Biometric Quality Workshop, vol. II, 2007, pp. 7–8 J. Ryu, J. Jang, H. Kim, Analysis of effect of fingerprint sample quality in template aging, in NIST Biometric Quality Workshop, vol. II, 2007, pp. 7–8
25.
26.
go back to reference J. Thornton, M. Savvides, V. Kumar, A Bayesian approach to deformed pattern matching of iris images. IEEE Trans. Pattern Anal. Mach. Intell. 29(4), 596–606 (2007)CrossRef J. Thornton, M. Savvides, V. Kumar, A Bayesian approach to deformed pattern matching of iris images. IEEE Trans. Pattern Anal. Mach. Intell. 29(4), 596–606 (2007)CrossRef
27.
go back to reference P. Tome-Gonzalez, F. Alonso-Fernandez, J. Ortega-Garcia, On the effects of time variability in iris recognition, in Proceedings of the Second IEEE Conference on Biometrics: Theory, Applications and Systems (2008) P. Tome-Gonzalez, F. Alonso-Fernandez, J. Ortega-Garcia, On the effects of time variability in iris recognition, in Proceedings of the Second IEEE Conference on Biometrics: Theory, Applications and Systems (2008)
28.
go back to reference U. Uludag, A. Ross, A. Jain, Biometric template selection and update: a case study in fingerprints. Pattern Recogn. 37, 1533–1542 (2008)CrossRefMATH U. Uludag, A. Ross, A. Jain, Biometric template selection and update: a case study in fingerprints. Pattern Recogn. 37, 1533–1542 (2008)CrossRefMATH
29.
go back to reference B. Winn et al., Factors affecting light-adapted pupil size in normal human subjects. Investig. Ophthalmol. Visual Sci. 35(3), 1132–1137 (1994) B. Winn et al., Factors affecting light-adapted pupil size in normal human subjects. Investig. Ophthalmol. Visual Sci. 35(3), 1132–1137 (1994)
30.
go back to reference K. Wright, P. Spiegel, Pediatric Ophthalmology and Strabismus (2003) K. Wright, P. Spiegel, Pediatric Ophthalmology and Strabismus (2003)
Metadata
Title
Template Aging in Iris Biometrics
Authors
Sarah E. Baker
Kevin W. Bowyer
Patrick J. Flynn
P. Jonathon Phillips
Copyright Year
2016
Publisher
Springer London
DOI
https://doi.org/10.1007/978-1-4471-6784-6_23

Premium Partner