The Detection of the Retina’s Lesions in Optical Coherence Tomography (OCT)

Author : Joanna Swiebocka-Wiek

Published in: Information Technology and Computational Physics

Publisher: Springer International Publishing

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

The Optical Coherence Tomography (OCT) is a very modern, noninvasive, and noncontact optical imaging technique. It is dedicated to different types of ocular tissues such as for example: the retina, optic disk, or cornea. During the examination, OCT is used for the early diagnosis of diseases such as: glaucoma, macular degeneration (AMD), diabetic changes in the retina, macular hole, macular edema, and eye cancer. These may inevitably lead to blindness, hence it is so important to ensure the patient of early and accurate diagnosis. The main goal of this paper is to propose a preliminary, automated method of detecting the occurrence of pathological changes in the retina (cysts and inflammation).

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Fercher, A.F.: Ophthalmic interferometry. In: von Bally, G., Khanna, S. (eds.) Proceedings of the International Conference on Optics in Life Sciences, pp. 221–228, Aug 1990 Fercher, A.F.: Ophthalmic interferometry. In: von Bally, G., Khanna, S. (eds.) Proceedings of the International Conference on Optics in Life Sciences, pp. 221–228, Aug 1990
2.
go back to reference Tanno, N., Ichikawa, T., Saeki, A.: Lightwave reflection measurement. Japanese Patent No. 2010042 (1990) Tanno, N., Ichikawa, T., Saeki, A.: Lightwave reflection measurement. Japanese Patent No. 2010042 (1990)
3.
go back to reference Chiba, S., Tanno, N.: Backscattering optical heterodyne tomography. In: Prepared for the 14th Laser Sensing Symposium (1991) Chiba, S., Tanno, N.: Backscattering optical heterodyne tomography. In: Prepared for the 14th Laser Sensing Symposium (1991)
4.
go back to reference Bouma, B.E., Tearney, G.J.: Handbook of Optical Coherence Tomography. Marcel Dekker Inc., New York, Basel (2002) Bouma, B.E., Tearney, G.J.: Handbook of Optical Coherence Tomography. Marcel Dekker Inc., New York, Basel (2002)
5.
go back to reference Bourquin, S., Seitz, P., Salathe R.P.: Optical coherence topography based on a two-dimensional smart detector array. Opt. Lett. 26(8), 512–514 (2001) Bourquin, S., Seitz, P., Salathe R.P.: Optical coherence topography based on a two-dimensional smart detector array. Opt. Lett. 26(8), 512–514 (2001)
6.
go back to reference Yeow, J.T.W., Yang, V.X.D., Chahwan, A., Gordon.: Micromachined 2-D Scanner for 3-D optical coherence tomography. Sensors Actuators 117(2) (2005) Yeow, J.T.W., Yang, V.X.D., Chahwan, A., Gordon.: Micromachined 2-D Scanner for 3-D optical coherence tomography. Sensors Actuators 117(2) (2005)
7.
go back to reference Drexler, W., Morgner, U., Ghanta, R.K., Kartner, F.X.: Ultrahigh-resolution ophthalmic optical coherence tomography. Nat. Med. 7(4), 502–507 (2001) Drexler, W., Morgner, U., Ghanta, R.K., Kartner, F.X.: Ultrahigh-resolution ophthalmic optical coherence tomography. Nat. Med. 7(4), 502–507 (2001)
8.
go back to reference Adhi, M., Duker, J.S.: Optical coherence tomography—current and future applications. Curr. Opin. Ophtamol. 24(3), 213–221 (2013) Adhi, M., Duker, J.S.: Optical coherence tomography—current and future applications. Curr. Opin. Ophtamol. 24(3), 213–221 (2013)
9.
go back to reference Bezerra, H.G., Costa, M.A., Guagliumi, G., Rollins, A.M.: Intracoronary optical coherence tomography: a comprehensive review clinical and research applications. JACC Cardiovasc. Interv. 2(11), 1035–1046 (2009) Bezerra, H.G., Costa, M.A., Guagliumi, G., Rollins, A.M.: Intracoronary optical coherence tomography: a comprehensive review clinical and research applications. JACC Cardiovasc. Interv. 2(11), 1035–1046 (2009)
10.
go back to reference Zysk, A.M., guyen, F.T., Oldenburg, A.L., Marks, D.L.: Optical coherence tomography: a review of clinical development from bench to bedside. J. Biomed. Opt. 5(12) (2007) Zysk, A.M., guyen, F.T., Oldenburg, A.L., Marks, D.L.: Optical coherence tomography: a review of clinical development from bench to bedside. J. Biomed. Opt. 5(12) (2007)
11.
go back to reference Fercher, A.F., Hitzenberger, C.K., Drexler, W., Kamp, G., Sattmann, H.: In Vivo optical coherence tomography. Am. J. Ophthalmol. 116, 113–114 (1993) Fercher, A.F., Hitzenberger, C.K., Drexler, W., Kamp, G., Sattmann, H.: In Vivo optical coherence tomography. Am. J. Ophthalmol. 116, 113–114 (1993)
15.
go back to reference Kharousi, N.A., Upender, K.W., Sitara, A.: Current applications of optical coherence tomography in ophthalmology, Chapter 1. In: INTECH (2013). doi:10.5772/53961. ISBN 978-953-51-1032-3 Kharousi, N.A., Upender, K.W., Sitara, A.: Current applications of optical coherence tomography in ophthalmology, Chapter 1. In: INTECH (2013). doi:10.​5772/​53961. ISBN 978-953-51-1032-3
Metadata
Title
The Detection of the Retina’s Lesions in Optical Coherence Tomography (OCT)
Author
Joanna Swiebocka-Wiek
Copyright Year
2017
DOI
https://doi.org/10.1007/978-3-319-44260-0_11

Premium Partner