9. Thermodynamic Analysis of a Refrigeration System Operating with R1234yf Refrigerant

Authors : Vedat Oruç, Atilla G. Devecioğlu

Published in: The Role of Exergy in Energy and the Environment

Publisher: Springer International Publishing

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

After restriction of European Union on using high-GWP refrigerants, the investigations have been directed to utilize low-GWP refrigerants in available systems to determine the suitability of their operating conditions. In this study, energy and exergy parameters were investigated as a result of using R1234yf in a refrigeration system originally constructed to operate with R134a. The experimental work was conducted at two different ambient temperatures of 20 and 40 °C, while the evaporation temperature was 0 °C. The temperature, pressure, electrical power consumption, and mass flow measurements in the system revealed cooling capacity, COP, and exergetic efficiency for both R134a and R1234yf refrigerants.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
2.
go back to reference Akasaka R (2010) An application of the extended corresponding states model to thermodynamic property calculations for trans-1,3,3,3-tetrafluoropropene (HFO-1234ze(E)). Int J Refrig 33:907–914CrossRef Akasaka R (2010) An application of the extended corresponding states model to thermodynamic property calculations for trans-1,3,3,3-tetrafluoropropene (HFO-1234ze(E)). Int J Refrig 33:907–914CrossRef
3.
go back to reference Navarro-Esbri J, Mendoza-Miranda JM, Mota-Babiloni A, Barragan-Cervera A, Belman-Flores JM (2013) Experimental analysis of R1234yf as a drop-in replacement for R134a in a vapor compression system. Int J Refrig 36:870–880CrossRef Navarro-Esbri J, Mendoza-Miranda JM, Mota-Babiloni A, Barragan-Cervera A, Belman-Flores JM (2013) Experimental analysis of R1234yf as a drop-in replacement for R134a in a vapor compression system. Int J Refrig 36:870–880CrossRef
4.
go back to reference Navarro-Esbri J, Moles F, Barragan-Cervera A (2013) Experimental analysis of the internal heat exchanger influence on a vapour compression system performance working with R1234yf as a drop-in replacement for R134a. Appl Therm Eng 59:153–161CrossRef Navarro-Esbri J, Moles F, Barragan-Cervera A (2013) Experimental analysis of the internal heat exchanger influence on a vapour compression system performance working with R1234yf as a drop-in replacement for R134a. Appl Therm Eng 59:153–161CrossRef
5.
go back to reference Fukuda S, Kondou C, Takata N, Koyama S (2014) Low GWP refrigerants R1234ze(E) and R1234ze(Z) for high temperature heat pumps. Int J Refrig 40:161–173. 298–306CrossRef Fukuda S, Kondou C, Takata N, Koyama S (2014) Low GWP refrigerants R1234ze(E) and R1234ze(Z) for high temperature heat pumps. Int J Refrig 40:161–173. 298–306CrossRef
6.
go back to reference Navarro-Esbrí J, Molés F, Peris B, Barragán-Cervera A, Mendoza-Miranda JM, Mota-Babiloni A, Belman JM (2014) Shell-and-tube evaporator model performance with different two-phase flow heat transfer correlations. Experimental analysis using R134a and R1234yf. Appl Therm Eng 62:80–89CrossRef Navarro-Esbrí J, Molés F, Peris B, Barragán-Cervera A, Mendoza-Miranda JM, Mota-Babiloni A, Belman JM (2014) Shell-and-tube evaporator model performance with different two-phase flow heat transfer correlations. Experimental analysis using R134a and R1234yf. Appl Therm Eng 62:80–89CrossRef
7.
go back to reference Zilio C, Brown JS, Schiochet G, Cavallini A (2011) The refrigerant R1234yf in air conditioning systems. Energy 36:6110–6120CrossRef Zilio C, Brown JS, Schiochet G, Cavallini A (2011) The refrigerant R1234yf in air conditioning systems. Energy 36:6110–6120CrossRef
8.
go back to reference Yana Motta S, Spatz M, Vera Becerra E (2010) Analysis of LGWP alternatives for small refrigeration (plug-in) applications. International refrigeration and air conditioning conference at Purdue. Link: http://docs.lib.purdue.edu/iracc/1149. Last accessed date: 09.06.2014 Yana Motta S, Spatz M, Vera Becerra E (2010) Analysis of LGWP alternatives for small refrigeration (plug-in) applications. International refrigeration and air conditioning conference at Purdue. Link: http://​docs.​lib.​purdue.​edu/​iracc/​1149. Last accessed date: 09.06.2014
9.
go back to reference Endoh K, Matsushima H, Takaku S (2010) Evaluation of cycle performance of room air conditioner using HFO-1234yf as refrigerant. International refrigeration and air conditioning conference at Purdue. Link: http://docs.lib.purdue.edu/iracc/1050. Last accessed date: 09.06.2014 Endoh K, Matsushima H, Takaku S (2010) Evaluation of cycle performance of room air conditioner using HFO-1234yf as refrigerant. International refrigeration and air conditioning conference at Purdue. Link: http://​docs.​lib.​purdue.​edu/​iracc/​1050. Last accessed date: 09.06.2014
10.
go back to reference Aprea C, Greco A, Maiorino A (2016) An experimental investigation on the substitution of HFC134a with HFO1234YF in a domestic refrigerator. Appl Therm Eng 106:959–967CrossRef Aprea C, Greco A, Maiorino A (2016) An experimental investigation on the substitution of HFC134a with HFO1234YF in a domestic refrigerator. Appl Therm Eng 106:959–967CrossRef
11.
go back to reference Pottker G, Hrnjak P (2015) Experimental investigation of the effect of condenser subcooling in R134a and R1234yf air conditioning systems with and without internal heat exchanger. Int J Refrig 50:104–113CrossRef Pottker G, Hrnjak P (2015) Experimental investigation of the effect of condenser subcooling in R134a and R1234yf air conditioning systems with and without internal heat exchanger. Int J Refrig 50:104–113CrossRef
12.
go back to reference Mota-Babiloni A, Navarro-Esbri J, Barragan-Cervera MF, Peris B (2014) Drop-in energy performance evaluation of R1234yf and R1234ze(E) in a vapor compression system as R134a replacements. Appl Therm Eng 71:259–265CrossRef Mota-Babiloni A, Navarro-Esbri J, Barragan-Cervera MF, Peris B (2014) Drop-in energy performance evaluation of R1234yf and R1234ze(E) in a vapor compression system as R134a replacements. Appl Therm Eng 71:259–265CrossRef
13.
go back to reference Jankovic Z, Atienza JS, Suarez JAM (2015) Thermodynamic and heat transfer analyses for R1234yf and R1234ze(E) as drop-in replacements for R134a in a small power refrigerating system. Appl Therm Eng 80:42–54CrossRef Jankovic Z, Atienza JS, Suarez JAM (2015) Thermodynamic and heat transfer analyses for R1234yf and R1234ze(E) as drop-in replacements for R134a in a small power refrigerating system. Appl Therm Eng 80:42–54CrossRef
14.
go back to reference Illan-Gomez F, Lopez-Belchi A, Garcia-Cascales JR, Vera-Garcia F (2015) Experimental two-phase heat transfer coefficient and frictional pressure drop inside mini-channels during condensation with R1234yf and R134a. Int J Refrig 51:12–23CrossRef Illan-Gomez F, Lopez-Belchi A, Garcia-Cascales JR, Vera-Garcia F (2015) Experimental two-phase heat transfer coefficient and frictional pressure drop inside mini-channels during condensation with R1234yf and R134a. Int J Refrig 51:12–23CrossRef
17.
go back to reference Devecioğlu AG, Oruç V (2017) The influence of plate-type heat exchanger on energy efficiency and environmental effects of the air-conditioners using R453A as a substitute for R22. Appl Therm Eng 112:1364–1372CrossRef Devecioğlu AG, Oruç V (2017) The influence of plate-type heat exchanger on energy efficiency and environmental effects of the air-conditioners using R453A as a substitute for R22. Appl Therm Eng 112:1364–1372CrossRef
18.
go back to reference Lemmon EW, Huber ML, McLinden MO (2013) NIST standard reference database 23 reference fluid thermodynamic and transport properties-REFPROP, version 9.1. National Institute of Standards and Technology, Standard Reference Data Program, Gaithersburg Lemmon EW, Huber ML, McLinden MO (2013) NIST standard reference database 23 reference fluid thermodynamic and transport properties-REFPROP, version 9.1. National Institute of Standards and Technology, Standard Reference Data Program, Gaithersburg
19.
go back to reference Stoecker WF, Jones JW (1982) Refrigeration and air conditioning. McGraw-Hill, Singapore Stoecker WF, Jones JW (1982) Refrigeration and air conditioning. McGraw-Hill, Singapore
20.
go back to reference Dinçer İ, Kanoğlu M (2010) Refrigeration systems and applications. Wiley, New YorkCrossRef Dinçer İ, Kanoğlu M (2010) Refrigeration systems and applications. Wiley, New YorkCrossRef
Metadata
Title
Thermodynamic Analysis of a Refrigeration System Operating with R1234yf Refrigerant
Authors
Vedat Oruç
Atilla G. Devecioğlu
Copyright Year
2018
DOI
https://doi.org/10.1007/978-3-319-89845-2_9