Abstract

Monitoring vital signs remotely is essential for accident victims because any movement can aggravate their health state. This paper proposes to evaluate the feasibility of heart rate measurements using a video camera with the subject lying down to simulate an emergency situation. Plane-Orthogonal-to-Skin method (POS) was used to estimate the blood volume variation. The cardiac frequency was calculated using the Fast Fourier Transform (FFT) technique. Three body positions were chosen for the study: Ventral Decubitus, Dorsal Decubitus and Lateral Decubitus. The results demonstrated the possibility to obtain reliable heart rate values in these conditions with average Root Mean Square Error (RMSE) of 3.04 bpm. Future work aims to develop and evaluate an application for mobile devices that maintain the privacy of the examined subject.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Sun Y, Nitish T (2016) Photoplethysmography revisited: from contact to noncontact, from point to imaging. IEEE Trans Biomed Eng 63:463–477CrossRef Sun Y, Nitish T (2016) Photoplethysmography revisited: from contact to noncontact, from point to imaging. IEEE Trans Biomed Eng 63:463–477CrossRef
2.
go back to reference Harford M, Catherall J, Gerry S, Young JD, Watkinson P (2019) Availability and performance of image-based, non-contact methods of monitoring heart rate, blood pressure, respiratory rate, and oxygen saturation: a systematic review. Physiol Measur 40:06TR01CrossRef Harford M, Catherall J, Gerry S, Young JD, Watkinson P (2019) Availability and performance of image-based, non-contact methods of monitoring heart rate, blood pressure, respiratory rate, and oxygen saturation: a systematic review. Physiol Measur 40:06TR01CrossRef
3.
go back to reference Aarts LAM, Jeanne V, Cleary JP et al (2013) Non-contact heart rate monitoring utilizing camera photoplethysmography in the neonatal intensive care unit–a pilot study. Early Hum Dev 89:943–948CrossRef Aarts LAM, Jeanne V, Cleary JP et al (2013) Non-contact heart rate monitoring utilizing camera photoplethysmography in the neonatal intensive care unit–a pilot study. Early Hum Dev 89:943–948CrossRef
4.
go back to reference Villarroel M, Chaichulee S, Jorge J et al (2019) Non-contact physiological monitoring of preterm infants in the Neonatal Intensive Care Unit. NPJ Digit Med 2:1–18CrossRef Villarroel M, Chaichulee S, Jorge J et al (2019) Non-contact physiological monitoring of preterm infants in the Neonatal Intensive Care Unit. NPJ Digit Med 2:1–18CrossRef
5.
go back to reference Rouast PV, Adam MTP, Chiong R, Cornforth D, Lux E (2018) Remote heart rate measurement using low-cost RGB face video: a technical literature review. Front Comput Sci 12:858–872CrossRef Rouast PV, Adam MTP, Chiong R, Cornforth D, Lux E (2018) Remote heart rate measurement using low-cost RGB face video: a technical literature review. Front Comput Sci 12:858–872CrossRef
6.
go back to reference Li P, Benezeth Y, Nakamura K, Gomez R, Li C, Yang F (2018) Comparison of region of interest segmentation methods for video-based heart rate measurements. In: 2018 IEEE 18th international conference on bioinformatics and bioengineering (BIBE). IEEE, pp 143–146 Li P, Benezeth Y, Nakamura K, Gomez R, Li C, Yang F (2018) Comparison of region of interest segmentation methods for video-based heart rate measurements. In: 2018 IEEE 18th international conference on bioinformatics and bioengineering (BIBE). IEEE, pp 143–146
7.
go back to reference Wilder-Smith A, Freedman DO (2020) Isolation, quarantine, social distancing and community containment: pivotal role for old-style public health measures in the novel coronavirus (2019-nCoV) outbreak. J Travel Med 27:taaa020CrossRef Wilder-Smith A, Freedman DO (2020) Isolation, quarantine, social distancing and community containment: pivotal role for old-style public health measures in the novel coronavirus (2019-nCoV) outbreak. J Travel Med 27:taaa020CrossRef
8.
go back to reference Prem K, Liu Y, Russell TW et al (2020) The effect of control strategies to reduce social mixing on outcomes of the COVID-19 epidemic in Wuhan, China: a modelling study. Lancet Publ Health 5(5):e261–e270CrossRef Prem K, Liu Y, Russell TW et al (2020) The effect of control strategies to reduce social mixing on outcomes of the COVID-19 epidemic in Wuhan, China: a modelling study. Lancet Publ Health 5(5):e261–e270CrossRef
9.
go back to reference Kowal M, Kubal S, Piotrowski P, Staniec K (2017) Practical Remarks on the Heart Rate and Saturation Measurement Methodology Measurement Science and Technology. 28:054003 Kowal M, Kubal S, Piotrowski P, Staniec K (2017) Practical Remarks on the Heart Rate and Saturation Measurement Methodology Measurement Science and Technology. 28:054003
10.
go back to reference Shahshahani A, Zilic Z, Bhadra S (2019) An ultrasound-based biomedical system for continuous cardiopulmonary monitoring: a single sensor for multiple information. IEEE Trans Biomed Eng 67:268–276CrossRef Shahshahani A, Zilic Z, Bhadra S (2019) An ultrasound-based biomedical system for continuous cardiopulmonary monitoring: a single sensor for multiple information. IEEE Trans Biomed Eng 67:268–276CrossRef
11.
go back to reference Di Rienzo M, Rizzo G, Işılay ZM, Lombardi P (2020) SeisMote: a multi-sensor wireless platform for cardiovascular monitoring in laboratory, daily life, and telemedicine. Sensors 20:680CrossRef Di Rienzo M, Rizzo G, Işılay ZM, Lombardi P (2020) SeisMote: a multi-sensor wireless platform for cardiovascular monitoring in laboratory, daily life, and telemedicine. Sensors 20:680CrossRef
12.
go back to reference Macwan R, Benezeth Y, Mansouri A (2018) Remote photoplethysmography with constrained ICA using periodicity and chrominance constraints. Biomed Eng Online 17:22CrossRef Macwan R, Benezeth Y, Mansouri A (2018) Remote photoplethysmography with constrained ICA using periodicity and chrominance constraints. Biomed Eng Online 17:22CrossRef
13.
go back to reference Van Rossum G, Drake FL (2011) The python language reference manual. Network Theory Ltd Van Rossum G, Drake FL (2011) The python language reference manual. Network Theory Ltd
14.
go back to reference Bradski G, Kaehler A (2008) Learning OpenCV: computer vision with the OpenCV library. O’Reilly Media, Inc Bradski G, Kaehler A (2008) Learning OpenCV: computer vision with the OpenCV library. O’Reilly Media, Inc
15.
go back to reference de Dios JJ, Garcia N (2003) Face detection based on a new color space YCgCr. In: Proceedings 2003 international conference on image processing (Cat. No.03CH37429); 3:III-909 de Dios JJ, Garcia N (2003) Face detection based on a new color space YCgCr. In: Proceedings 2003 international conference on image processing (Cat. No.03CH37429); 3:III-909
16.
go back to reference Wang W, den Brinker AC, Stuijk S, de Haan G (2017) Algorithmic principles of remote PPG. IEEE Trans Biomed Eng 64:1479–1491CrossRef Wang W, den Brinker AC, Stuijk S, de Haan G (2017) Algorithmic principles of remote PPG. IEEE Trans Biomed Eng 64:1479–1491CrossRef
17.
go back to reference Poh M-Z, McDuff DJ, Picard RW (2010) Non-contact, automated cardiac pulse measurements using video imaging and blind source separation. Opt Exp 18:10762–10774CrossRef Poh M-Z, McDuff DJ, Picard RW (2010) Non-contact, automated cardiac pulse measurements using video imaging and blind source separation. Opt Exp 18:10762–10774CrossRef
18.
go back to reference Artemyev M, Marina C, Mikhail G, Olga P (2020) Robust algorithm for remote photoplethysmography in realistic conditions. Digit Sig Process 104:102737CrossRef Artemyev M, Marina C, Mikhail G, Olga P (2020) Robust algorithm for remote photoplethysmography in realistic conditions. Digit Sig Process 104:102737CrossRef
Metadata
Title
Towards a Remote Vital Sign Monitoring in Accidents
Authors
A. Floriano
R. S. Rosa
L. C. Lampier
E. Caldeira,
T. F. Bastos-Filho
Copyright Year
2022
DOI
https://doi.org/10.1007/978-3-030-70601-2_231