Transfemoral Residual Limb Volume Change Due to Physical Activity

Authors : Linda Paternò, Michele Ibrahimi, Elisa Rosini, Arianna Menciassi, Leonardo Ricotti

Published in: Converging Clinical and Engineering Research on Neurorehabilitation III

Publisher: Springer International Publishing

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

In the state-of-the-art, only few studies analyzed volume changes in residual lower limbs. Most of them focused on transtibial amputees, while data on transfemoral ones are largely missing. This study aims at investigating how transfemoral stumps change over time. A measurement system based on a portable 3D optical scanning technique was used to measure volume fluctuations in 6 transfemoral amputees prior to and 20 min after physical activity. Such technique allowed to measure the stump volume once outside of the prosthetic socket. Investigating stump volume changes over time after prosthesis doffing is necessary to take into account this source of error during tests. Data show that volume fluctuations range from −1.25% to +3.09%. These values were enough to cause patient discomfort. This study highlights the need to properly characterize volume changes with the aim of designing more efficient socket solutions, based on such data.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Paterno, L., et al.: Sockets for limb prostheses: a review of existing technologies and open challenges. IEEE Trans. Biomed. Eng. 65(9), 1996–2010 (2018)CrossRef Paterno, L., et al.: Sockets for limb prostheses: a review of existing technologies and open challenges. IEEE Trans. Biomed. Eng. 65(9), 1996–2010 (2018)CrossRef
2.
go back to reference Sanders, J.E., Fatone, S.: Residual limb volume change: systematic review of measurement and management. JRRD 48(8), 949–986 (2011)CrossRef Sanders, J.E., Fatone, S.: Residual limb volume change: systematic review of measurement and management. JRRD 48(8), 949–986 (2011)CrossRef
3.
go back to reference de Boer-Wilzing, V.G., et al.: Variation in results of volume measurements of stumps of lower-limb amputees: a comparison of 4 methods. Arch. Phys. Med. Rehabil. 92(6), 941–946 (2011)CrossRef de Boer-Wilzing, V.G., et al.: Variation in results of volume measurements of stumps of lower-limb amputees: a comparison of 4 methods. Arch. Phys. Med. Rehabil. 92(6), 941–946 (2011)CrossRef
4.
go back to reference Zachariah, S.G., et al.: Shape and volume change in the transtibial residuum over the short term: preliminary investigation of six subjects. JRRD 41(5), 683–694 (2004)CrossRef Zachariah, S.G., et al.: Shape and volume change in the transtibial residuum over the short term: preliminary investigation of six subjects. JRRD 41(5), 683–694 (2004)CrossRef
Metadata
Title
Transfemoral Residual Limb Volume Change Due to Physical Activity
Authors
Linda Paternò
Michele Ibrahimi
Elisa Rosini
Arianna Menciassi
Leonardo Ricotti
Copyright Year
2019
DOI
https://doi.org/10.1007/978-3-030-01845-0_29