Abstract

The use of commercially available Screen Printed Electrodes (SPEs) in Pulsed Voltammetric techniques for the determination of carcinogenic compounds, (namely furan, benzidines and chromium (VI)), is presented. The advantages related to the SPEs disposability and to the electrodes protection with Nafion® membrane for fouling prevention is shown.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Barek J, Cvačka J, Muck A, Quaiserová V, Zima J (2001) Electrochemical methods for monitoring of environmental carcinogens. Fresenius J Anal Chem 369:556–562CrossRef Barek J, Cvačka J, Muck A, Quaiserová V, Zima J (2001) Electrochemical methods for monitoring of environmental carcinogens. Fresenius J Anal Chem 369:556–562CrossRef
2.
go back to reference Barek J, Peckova K, Vyskocil V (2008) Adsorptive stripping voltammetry of environmental carcinogens. Curr Anal Chem 4:242–249CrossRef Barek J, Peckova K, Vyskocil V (2008) Adsorptive stripping voltammetry of environmental carcinogens. Curr Anal Chem 4:242–249CrossRef
3.
go back to reference Brett CMA, Oliveira-Brett AM (2011) Electrochemical sensing in solution-origins, application and future perspectives. J Solid State Electrochem 15:1487–1494CrossRef Brett CMA, Oliveira-Brett AM (2011) Electrochemical sensing in solution-origins, application and future perspectives. J Solid State Electrochem 15:1487–1494CrossRef
4.
go back to reference Alvarez-Icaza M, Bilitewski U (1993) Mass production of biosensors. Anal Chem 65:525A–533ACrossRef Alvarez-Icaza M, Bilitewski U (1993) Mass production of biosensors. Anal Chem 65:525A–533ACrossRef
5.
go back to reference Wang J, Tian B, Nascimento VB, Angnes L (1998) Performance of screen- printed carbon electrodes fabricated from different carbon inks. Electrochim Acta 43(23):3459–3465CrossRef Wang J, Tian B, Nascimento VB, Angnes L (1998) Performance of screen- printed carbon electrodes fabricated from different carbon inks. Electrochim Acta 43(23):3459–3465CrossRef
6.
go back to reference Laschi S, Franek M, Mascini M (2000) Screen printed electrochemical immunosensors for PCB detection. Electroanalysis 12:1293–1298CrossRef Laschi S, Franek M, Mascini M (2000) Screen printed electrochemical immunosensors for PCB detection. Electroanalysis 12:1293–1298CrossRef
7.
go back to reference Gonzáles-García O, Ariño C, Díaz-Cruz JM, Esteban M (2011) Development and possibilities of multichannel voltammetric detection in liquid chromatography. Electroanalysis 23(1):140–146CrossRef Gonzáles-García O, Ariño C, Díaz-Cruz JM, Esteban M (2011) Development and possibilities of multichannel voltammetric detection in liquid chromatography. Electroanalysis 23(1):140–146CrossRef
8.
go back to reference Falciola L, Pifferi V, Possenti ML, Carrara V (2012) Square wave voltammetric detection of furan on platinum and platinum-based screen printed electrodes. J Electroanal Chem 664:100–104CrossRef Falciola L, Pifferi V, Possenti ML, Carrara V (2012) Square wave voltammetric detection of furan on platinum and platinum-based screen printed electrodes. J Electroanal Chem 664:100–104CrossRef
9.
go back to reference Falciola L, Pifferi V, Mascheroni E (2012) Platinum-based and carbon-based screen printed electrodes for the determination of benzidine by differential pulse voltammetry. Electroanalysis 24(4):767–775CrossRef Falciola L, Pifferi V, Mascheroni E (2012) Platinum-based and carbon-based screen printed electrodes for the determination of benzidine by differential pulse voltammetry. Electroanalysis 24(4):767–775CrossRef
10.
go back to reference Pifferi V, Spadavecchia F, Cappelletti G, Paoli EA, Falciola L (2013) Electrodeposited nano-titania films for photocatalytic Cr(VI) reduction. Catal Today 209:8–12 Pifferi V, Spadavecchia F, Cappelletti G, Paoli EA, Falciola L (2013) Electrodeposited nano-titania films for photocatalytic Cr(VI) reduction. Catal Today 209:8–12
Metadata
Title
Use of Screen-Printed Electrodes in the Determination of Some Environmental Carcinogens
Authors
L. Falciola
G. Cappelletti
V. Pifferi
F. Spadavecchia
Copyright Year
2014
Publisher
Springer New York
DOI
https://doi.org/10.1007/978-1-4614-3860-1_26