Skip to main content
Top

2009 | OriginalPaper | Chapter

Wireless Communication Systems from the Perspective of Implantable Sensor Networks for Neural Signal Monitoring

Authors : C. Tarín, L. Traver, P. Martí, N. Cardona

Published in: Wireless Technology

Publisher: Springer US

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Recent advances in modern neurocomputing heading toward promising clinical applications of implantable neuronal sensing devices have shown the utmost necessity of wireless communication systems that allow real-time monitoring of neural signals. The design of a wireless transmission system for this particular application shall meet several requirements involving source compression of the high data rate neural recording, communication with a standard device as bridge between body area and remote server, and high fidelity of the received signal to ensure effective brain activity monitoring. A wireless transmission system over Bluetooth and 3G is analyzed for its application to the real-time transmission of neural signals captured by implanted micro-electrode array sensors. Average compression rate of 75% of the neural signal is achieved through detection using nonlinear energy operator preprocessing and automatic threshold adaptation. The wireless transmission of these signals integrates a Bluetooth transmission from the information source to a conventional mobile device and then over 3G to a remote server, without intermediate storage on the mobile phone. Reconstruction of the coded neural signal provides the input to high-performance spike classification algorithm allowing the tracking of individual neuron spiking patterns.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Akin T, Najafi K, Bradley R (1998) A wireless implantable multichannel digital neural recording system for a micromachines sieve electrode. IEEE Journal of Solid State Circuits, 1, 33, 109–118CrossRef Akin T, Najafi K, Bradley R (1998) A wireless implantable multichannel digital neural recording system for a micromachines sieve electrode. IEEE Journal of Solid State Circuits, 1, 33, 109–118CrossRef
2.
go back to reference Anderson DJ, Oweiss KG (2003) Capturing Signal Activity and Spatial Distribution of Neurons in a Sub-Millimeter Volume. Conference Record of the 37th Asilomar Conference on Signals, Systems and Computers, 1, 387–390 Anderson DJ, Oweiss KG (2003) Capturing Signal Activity and Spatial Distribution of Neurons in a Sub-Millimeter Volume. Conference Record of the 37th Asilomar Conference on Signals, Systems and Computers, 1, 387–390
4.
go back to reference Brown EN, Kass RE, Mitra PP (2004) Multiple neural spike train data analysis: state-of-the-art and future challenges. Nature Neuroscience, 7, 5, 456–461CrossRef Brown EN, Kass RE, Mitra PP (2004) Multiple neural spike train data analysis: state-of-the-art and future challenges. Nature Neuroscience, 7, 5, 456–461CrossRef
5.
go back to reference Fernández E, Pelayo F, Romero S, Bongard M, Marín C, Alfaro A, Merabet L (2005) Development of a cortical visual neuroprosthesis for the blind: the relevance of neuroplasticity. Journal of Neural Engineering, 2, R1–R12CrossRef Fernández E, Pelayo F, Romero S, Bongard M, Marín C, Alfaro A, Merabet L (2005) Development of a cortical visual neuroprosthesis for the blind: the relevance of neuroplasticity. Journal of Neural Engineering, 2, R1–R12CrossRef
6.
go back to reference Hochberg LR, Serruya MD, Friehs GM, Mukand JA, Saleh M, Caplan AH, Branner A, Chen D, Penn RD, Donoghue JP (2006) Neuronal ensemble control of prosthetic devices by a human with tetraplegia. Nature, 442, 164–171CrossRef Hochberg LR, Serruya MD, Friehs GM, Mukand JA, Saleh M, Caplan AH, Branner A, Chen D, Penn RD, Donoghue JP (2006) Neuronal ensemble control of prosthetic devices by a human with tetraplegia. Nature, 442, 164–171CrossRef
7.
go back to reference Irazoqui-Pastor P, Mody I, Judy JW (2002) Transcutaneous rf-powered neural recording device. Second Joint EMBS/BMES Conference, Houston, USA, 3, 2105–2106 Irazoqui-Pastor P, Mody I, Judy JW (2002) Transcutaneous rf-powered neural recording device. Second Joint EMBS/BMES Conference, Houston, USA, 3, 2105–2106
8.
go back to reference Irazoqui-Pastor P, Mody I, Judy JW (2005) Recording brain activity wirelessly. IEEE Engineering in Medicine and Biology Magazine, 24, 6, 48–54CrossRef Irazoqui-Pastor P, Mody I, Judy JW (2005) Recording brain activity wirelessly. IEEE Engineering in Medicine and Biology Magazine, 24, 6, 48–54CrossRef
9.
go back to reference Ju MC, Park CH, Hong DK, Youn KJ, Cho JW (2002) Link management scheme of bluetooth based on channel quality estimation. Electronics Letters, 38, 15, 89–790CrossRef Ju MC, Park CH, Hong DK, Youn KJ, Cho JW (2002) Link management scheme of bluetooth based on channel quality estimation. Electronics Letters, 38, 15, 89–790CrossRef
10.
go back to reference Kim K, Kim S (2000) Neural spike sorting under nearly 0 dB signal-to-noise ratio using nonlinear energy operator and artificial neural-network classifier. IEEE Transactions on Biomedical Engineering, 47, 10, 1406–1411CrossRef Kim K, Kim S (2000) Neural spike sorting under nearly 0 dB signal-to-noise ratio using nonlinear energy operator and artificial neural-network classifier. IEEE Transactions on Biomedical Engineering, 47, 10, 1406–1411CrossRef
11.
go back to reference Lebedev MA, Carmena JM, O’Doherty JE, Zacksenhouse M, Henriquez CS, Principe JC, Nicolelis MAL (2005) Cortical ensemble adaptation to represent velocity of an artificial actuator controlled by a brain-machine interface. The Journal of Neuroscience, 25, 19, 4681–4693CrossRef Lebedev MA, Carmena JM, O’Doherty JE, Zacksenhouse M, Henriquez CS, Principe JC, Nicolelis MAL (2005) Cortical ensemble adaptation to represent velocity of an artificial actuator controlled by a brain-machine interface. The Journal of Neuroscience, 25, 19, 4681–4693CrossRef
12.
go back to reference Letelier JC, Weber PP (2000) Spike sorting based on discrete wavelet transform coefficients. Journal of Neuroscience Methods, 2, 101, 93–106CrossRef Letelier JC, Weber PP (2000) Spike sorting based on discrete wavelet transform coefficients. Journal of Neuroscience Methods, 2, 101, 93–106CrossRef
13.
go back to reference Lopez-Casado C, Tejero-Calado J, Bernal-Martin A, Lopez-Gomez M, Romero-Romero M, Quesada G, Lorca J, Garcia E (2005) Network architecture for global biomedical monitoring service. 27th Annual International Conference of the Engineering in Medicine and Biology Society, Shanghai, China, pp. 2433–2436 Lopez-Casado C, Tejero-Calado J, Bernal-Martin A, Lopez-Gomez M, Romero-Romero M, Quesada G, Lorca J, Garcia E (2005) Network architecture for global biomedical monitoring service. 27th Annual International Conference of the Engineering in Medicine and Biology Society, Shanghai, China, pp. 2433–2436
14.
go back to reference Martinoiaa S, Sanguinetib V, Cozzib L, Berdondinic L, van Peltd J, Tomase J, Le Massonf G, Davideg F (2004) Towards an embodied in vitro electrophysiology: the NeuroBIT project. Neurocomputing, 60, 58, 1065–1072CrossRef Martinoiaa S, Sanguinetib V, Cozzib L, Berdondinic L, van Peltd J, Tomase J, Le Massonf G, Davideg F (2004) Towards an embodied in vitro electrophysiology: the NeuroBIT project. Neurocomputing, 60, 58, 1065–1072CrossRef
15.
go back to reference Mojarradi M, Binkley D, Blalock B, Anderson R, Ulshoefer N, Johnson T (2003) A miniaturized neuroprosthesis suitable for implantation into the brain. IEEE Transactions on Neural Systems and Rehabilitation Engineering, 3, 11, 38–42CrossRef Mojarradi M, Binkley D, Blalock B, Anderson R, Ulshoefer N, Johnson T (2003) A miniaturized neuroprosthesis suitable for implantation into the brain. IEEE Transactions on Neural Systems and Rehabilitation Engineering, 3, 11, 38–42CrossRef
16.
go back to reference Morrow R, (2000) Connecting with a bluetooth piconet. Fall Wireless Symposium/Portable By Design Conference and Exhibition, Chicago Morrow R, (2000) Connecting with a bluetooth piconet. Fall Wireless Symposium/Portable By Design Conference and Exhibition, Chicago
17.
18.
go back to reference Obeid I, Nicolelis MAL, Wolf PD (2004a) A multichannel telemetry system for single unit neural recording. The Journal of Neuroscience Methods, 133, 33–38CrossRef Obeid I, Nicolelis MAL, Wolf PD (2004a) A multichannel telemetry system for single unit neural recording. The Journal of Neuroscience Methods, 133, 33–38CrossRef
19.
go back to reference Obeid I, Nicolelis MAL, Wolf PD (2004b) A low power multichannel analog front end for portable neural signal recordings. The Journal of Neuroscience Methods, 133, 27–32CrossRef Obeid I, Nicolelis MAL, Wolf PD (2004b) A low power multichannel analog front end for portable neural signal recordings. The Journal of Neuroscience Methods, 133, 27–32CrossRef
20.
go back to reference Obeid I, Wolf PD (2004) Evaluation of Spike-detection algorithms for a brain-machine interface application. IEEE Transactions on Biomedical Engineering, 51, 6, 905–911CrossRef Obeid I, Wolf PD (2004) Evaluation of Spike-detection algorithms for a brain-machine interface application. IEEE Transactions on Biomedical Engineering, 51, 6, 905–911CrossRef
21.
go back to reference Olson BP, Si J, Hu J, He J (2005) Closed-loop cortical control of direction using support vector machines. IEEE Transactions on Neural systems and Rehabilitation Engineering, 13, 1, 72–80CrossRef Olson BP, Si J, Hu J, He J (2005) Closed-loop cortical control of direction using support vector machines. IEEE Transactions on Neural systems and Rehabilitation Engineering, 13, 1, 72–80CrossRef
22.
go back to reference Ryugo DK, Kretzmer EA, Niparko JK. (2005) Restoration of auditory nerve synapses in cats by cochlear implants. Science, 310, 5753, 1490–1492CrossRef Ryugo DK, Kretzmer EA, Niparko JK. (2005) Restoration of auditory nerve synapses in cats by cochlear implants. Science, 310, 5753, 1490–1492CrossRef
23.
go back to reference Salamon D, Bei A, Grigioni M, Gianni M, Liberti M, D’Inzeo G, Luca SD (2005) Indoor telemedicine in hospital: a pda-based flexible solution for wireless monitoring and database integration. 27th Annual International Conference of the Engineering in Medicine and Biology Society, Shanghai, China, pp. 386–389 Salamon D, Bei A, Grigioni M, Gianni M, Liberti M, D’Inzeo G, Luca SD (2005) Indoor telemedicine in hospital: a pda-based flexible solution for wireless monitoring and database integration. 27th Annual International Conference of the Engineering in Medicine and Biology Society, Shanghai, China, pp. 386–389
24.
go back to reference Tarín C, Martí P, Traver L, Cardona N, Díaz JA, Antonino E (2007) UWB Channel Measurements for hand-portable devices: a comparative study. IEEE International Symposium on Personal, Indoor and Mobile Radio Communications, Athens, Greece, pp. 1–5 Tarín C, Martí P, Traver L, Cardona N, Díaz JA, Antonino E (2007) UWB Channel Measurements for hand-portable devices: a comparative study. IEEE International Symposium on Personal, Indoor and Mobile Radio Communications, Athens, Greece, pp. 1–5
25.
go back to reference Tarín C, Traver L, Martí P, Cardona N, Díaz JA, Cabedo M (2007) UWB Channel measures for hand-portable and wearable devices. IEEE International Conference on Wireless and Mobile Computing, Networking and Communications, New York, USA, pp. 1–6 Tarín C, Traver L, Martí P, Cardona N, Díaz JA, Cabedo M (2007) UWB Channel measures for hand-portable and wearable devices. IEEE International Conference on Wireless and Mobile Computing, Networking and Communications, New York, USA, pp. 1–6
26.
go back to reference Tarín C, Traver L, Santamaría JF, Martí P, Cardona N (2007) Bluetooth-3G wireless transmission system for neural signal telemetry. IEEE Wireless Telecommunications Symposium, Pomona, California, USA, pp. 1–6 Tarín C, Traver L, Santamaría JF, Martí P, Cardona N (2007) Bluetooth-3G wireless transmission system for neural signal telemetry. IEEE Wireless Telecommunications Symposium, Pomona, California, USA, pp. 1–6
27.
go back to reference Taylor DM, Helms Tillery SI, Schwartz AB (2002) Direct cortical control of 3D neuroprosthetic devices. Science, 296, 1829–1832CrossRef Taylor DM, Helms Tillery SI, Schwartz AB (2002) Direct cortical control of 3D neuroprosthetic devices. Science, 296, 1829–1832CrossRef
29.
go back to reference Wessberg J, Stambaugh CR, Kralik JD, Beck PD, Laubach M, Chapin JK (2000) Real-time prediction of hand trajectory by ensembles of cortical neurons in primates. Nature, 408, 6810, 361–365CrossRef Wessberg J, Stambaugh CR, Kralik JD, Beck PD, Laubach M, Chapin JK (2000) Real-time prediction of hand trajectory by ensembles of cortical neurons in primates. Nature, 408, 6810, 361–365CrossRef
30.
go back to reference Wise KD, Anderson DJ, Hetke JF, Kipke DR, Njafi K (2004) Wireless implantable microsystems: High-density electronic interfaces to the nervous system. Proceedings of the IEEE, 92,1, 76–97 Wise KD, Anderson DJ, Hetke JF, Kipke DR, Njafi K (2004) Wireless implantable microsystems: High-density electronic interfaces to the nervous system. Proceedings of the IEEE, 92,1, 76–97
31.
go back to reference Wood F, Black MJ, Vargas-Irwin C, Fellows M, Donogue JP (2004) On the variability of manual spike sorting. IEEE Transactions on Biomedical Engineering, 51, 6, 912–918CrossRef Wood F, Black MJ, Vargas-Irwin C, Fellows M, Donogue JP (2004) On the variability of manual spike sorting. IEEE Transactions on Biomedical Engineering, 51, 6, 912–918CrossRef
32.
go back to reference Yu SN, Cheng JC (2005) A wireless physiological signal monitoring system with integrated bluetooth and wifi technologies. 27th Annual International Conference of the Engineering in Medicine and Biology Society, Shanghai, China, pp. 2203–2206 Yu SN, Cheng JC (2005) A wireless physiological signal monitoring system with integrated bluetooth and wifi technologies. 27th Annual International Conference of the Engineering in Medicine and Biology Society, Shanghai, China, pp. 2203–2206
33.
go back to reference Zasowski T, Althaus F, Stäger M, Wittneben A, Tröster G (2003) UWB for noninvasive wireless body area networks: Channel measurements and results. IEEE Conference on Ultra Wideband Systems and Technologies, pp. 1–10 Zasowski T, Althaus F, Stäger M, Wittneben A, Tröster G (2003) UWB for noninvasive wireless body area networks: Channel measurements and results. IEEE Conference on Ultra Wideband Systems and Technologies, pp. 1–10
34.
go back to reference Zumsteg ZS, Kemere C, O’Driscoll S, Santhanam G, Ahmed RE, Shenoy KV, Meng TH (2005) Power feasibility of implantable digital spike sorting circuits for neural prosthetic systems. IEEE Transactions on Neural Systems and Rehabilitation Engineering, 13, 3, 272–279CrossRef Zumsteg ZS, Kemere C, O’Driscoll S, Santhanam G, Ahmed RE, Shenoy KV, Meng TH (2005) Power feasibility of implantable digital spike sorting circuits for neural prosthetic systems. IEEE Transactions on Neural Systems and Rehabilitation Engineering, 13, 3, 272–279CrossRef
Metadata
Title
Wireless Communication Systems from the Perspective of Implantable Sensor Networks for Neural Signal Monitoring
Authors
C. Tarín
L. Traver
P. Martí
N. Cardona
Copyright Year
2009
Publisher
Springer US
DOI
https://doi.org/10.1007/978-0-387-71787-6_12