Abstract

This chapter proposed a personalized X-ray reconstruction-based planning and post-operative treatment evaluation framework called iJoint for advancing modern Total Hip Arthroplasty (THA). Based on a mobile X-ray image calibration phantom and a unique 2D-3D reconstruction technique, iJoint can generate patient-specific models of hip joint by non-rigidly matching statistical shape models to the X-ray radiographs. Such a reconstruction enables a true 3D planning and treatment evaluation of hip arthroplasty from just 2D X-ray radiographs whose acquisition is part of the standard diagnostic and treatment loop. As part of the system, a 3D model-based planning environment provides surgeons with hip arthroplasty related parameters such as implant type, size, position, offset and leg length equalization. With this newly developed system, we are able to provide true 3D solutions for computer assisted planning of THA using only 2D X-ray radiographs, which is not only innovative but also cost-effective.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Kiefer H (2007) Differences and opportunities of THA in the USA, Asia and Europe. In: Chang J-D, Billau K (eds) Ceramics in orthopaedics. Proceedings of the 12th BIOLOX® symposium on bioceramics and alternative bearings in joint arthroplasty. Springer, Berlin, pp 3–8 Kiefer H (2007) Differences and opportunities of THA in the USA, Asia and Europe. In: Chang J-D, Billau K (eds) Ceramics in orthopaedics. Proceedings of the 12th BIOLOX® symposium on bioceramics and alternative bearings in joint arthroplasty. Springer, Berlin, pp 3–8
2.
go back to reference Charnley J (1979) Low friction arthroplasty of the hip. Springer, Berlin Charnley J (1979) Low friction arthroplasty of the hip. Springer, Berlin
3.
go back to reference Müller ME (1992) Lessons of 30 years of total hip arthroplasty. Clin Orthop Relat Res 274:12–21 Müller ME (1992) Lessons of 30 years of total hip arthroplasty. Clin Orthop Relat Res 274:12–21
4.
go back to reference Gonzalez Della Valle A, Slullitel G, Piccaluga F, Salvati EA (2005) The precision and usefulness of pre-operative planning for cemented and hybrid primary total hip arthroplasty. J Arthroplasty 20:51–58 Gonzalez Della Valle A, Slullitel G, Piccaluga F, Salvati EA (2005) The precision and usefulness of pre-operative planning for cemented and hybrid primary total hip arthroplasty. J Arthroplasty 20:51–58
5.
go back to reference Eggli S, Pisan M, Mueller M (1998) The value of preoperative planning for total hip arthroplasty. J Bone Joint Surg Br 80:382–390CrossRef Eggli S, Pisan M, Mueller M (1998) The value of preoperative planning for total hip arthroplasty. J Bone Joint Surg Br 80:382–390CrossRef
6.
go back to reference Carter LW, Stovall DO, Young TR (1995) Determination of accuracy of preoperative templating of noncemented femoral prostheses. J Arthroplasty 10:507–513 Carter LW, Stovall DO, Young TR (1995) Determination of accuracy of preoperative templating of noncemented femoral prostheses. J Arthroplasty 10:507–513
7.
go back to reference Unnanuntana A, Wagner D, Goodman SB (2009) The accuracy of peroperative templating in cementless total hip arthroplasty. J Arthroplasty 24:180–186 Unnanuntana A, Wagner D, Goodman SB (2009) The accuracy of peroperative templating in cementless total hip arthroplasty. J Arthroplasty 24:180–186
8.
go back to reference Viceconti M, Lattanzi R, Antonietti B, Paderni S, Olmi R, Sudanese A, Toni A (2003) CT-based surgical planning software improves the accuracy of total hip replacement preoperative planning. Med Eng Phys 25:371–377CrossRef Viceconti M, Lattanzi R, Antonietti B, Paderni S, Olmi R, Sudanese A, Toni A (2003) CT-based surgical planning software improves the accuracy of total hip replacement preoperative planning. Med Eng Phys 25:371–377CrossRef
9.
go back to reference Huppertz A, Radmer S, Wagner M, Roessler T, Hamm B, Sparmann M (2014) Computed tomography for preoperative planning in total hip arthroplasty: what radiologists need to know. Skeletal Radiol 43:1041–1051CrossRef Huppertz A, Radmer S, Wagner M, Roessler T, Hamm B, Sparmann M (2014) Computed tomography for preoperative planning in total hip arthroplasty: what radiologists need to know. Skeletal Radiol 43:1041–1051CrossRef
10.
go back to reference Sariali E, Mauprivez R, Khiami H, Pascal-Mousselard H, Catonne Y (2012) Accuracy of the preoperative planning for cementless total hip arthroplasty. A randomised comparison between three-dimensional computerised planning and conventional templating. Orthop Traumatol Surg Res 98:151–158CrossRef Sariali E, Mauprivez R, Khiami H, Pascal-Mousselard H, Catonne Y (2012) Accuracy of the preoperative planning for cementless total hip arthroplasty. A randomised comparison between three-dimensional computerised planning and conventional templating. Orthop Traumatol Surg Res 98:151–158CrossRef
11.
go back to reference Huppertz A, Radmer S, Asbach P, Juran R, Schwenke C, Diederichs G, Hamm B, Sparmann M (2011) Computed tomography for preoperative planning in minimal-invasive total hip arthroplasty: radiation exposure and cost analysis. Eur J Radiol 78:406–413CrossRef Huppertz A, Radmer S, Asbach P, Juran R, Schwenke C, Diederichs G, Hamm B, Sparmann M (2011) Computed tomography for preoperative planning in minimal-invasive total hip arthroplasty: radiation exposure and cost analysis. Eur J Radiol 78:406–413CrossRef
12.
go back to reference Otomaru I, Nakamoto M, Kagiyama Y, Takao M, Sugano N, Tomiyama N, Tada Y, Sato Y (2012) Automated preoperative planning of femoral stem in total hip arthroplasty from 3D CT data: Atlas-based approach and comparative study. Med Image Anal 16:415–426CrossRef Otomaru I, Nakamoto M, Kagiyama Y, Takao M, Sugano N, Tomiyama N, Tada Y, Sato Y (2012) Automated preoperative planning of femoral stem in total hip arthroplasty from 3D CT data: Atlas-based approach and comparative study. Med Image Anal 16:415–426CrossRef
13.
go back to reference Hassani H, CheriX S, Ek ET, Ruediger HA (2014) Comparisons of preoperative three-dimensional planning and surgical reconstruction in primary cementless total hip arthroplasty. J Arthroplasty 29:1273–1277CrossRef Hassani H, CheriX S, Ek ET, Ruediger HA (2014) Comparisons of preoperative three-dimensional planning and surgical reconstruction in primary cementless total hip arthroplasty. J Arthroplasty 29:1273–1277CrossRef
14.
go back to reference Dubousset J, Charpak G, Skalli W, Deguise J, Kalifa G (2010) EOS: a new imaging system with low dose radiation in standing position for spine and bone & joint disorders. J Musculoskelet Res 13:1–12CrossRef Dubousset J, Charpak G, Skalli W, Deguise J, Kalifa G (2010) EOS: a new imaging system with low dose radiation in standing position for spine and bone & joint disorders. J Musculoskelet Res 13:1–12CrossRef
15.
go back to reference Wybier M, Bossard P (2013) Musculoskeletal imaging in progress: the EOS imaging system. Joint Bone Spine 80:238–243CrossRef Wybier M, Bossard P (2013) Musculoskeletal imaging in progress: the EOS imaging system. Joint Bone Spine 80:238–243CrossRef
16.
go back to reference Illes T, Somoskeoy S (2012) The EOS imaging system and its use in daily orthopaedic practice. Int. Orthop 36:1325–1331 Illes T, Somoskeoy S (2012) The EOS imaging system and its use in daily orthopaedic practice. Int. Orthop 36:1325–1331
17.
go back to reference Wade R, Yang H, McKenna C, Faria R, Gummerson N, Woolacott N (2013) A systematic review of the clinical effectiveness of EOS 2D/3D X-ray imaging system. Eur Spine J 22:296–304 Wade R, Yang H, McKenna C, Faria R, Gummerson N, Woolacott N (2013) A systematic review of the clinical effectiveness of EOS 2D/3D X-ray imaging system. Eur Spine J 22:296–304
18.
go back to reference Deschenes S, Charron G, Beaudoin G, Labelle H, Dubois J, Miron MC, Parent S (2010) Diagnostic imaging of spinal deformities—reducing patients radiation dose with a new slot-scanning X-ray imager. Spine 35:989–994 Deschenes S, Charron G, Beaudoin G, Labelle H, Dubois J, Miron MC, Parent S (2010) Diagnostic imaging of spinal deformities—reducing patients radiation dose with a new slot-scanning X-ray imager. Spine 35:989–994
19.
go back to reference Glaser DA, Doan J, Newton PO (2012) Comparison of 3-dimensional spinal reconstruction accuracy. Spine 37:1391–1397 Glaser DA, Doan J, Newton PO (2012) Comparison of 3-dimensional spinal reconstruction accuracy. Spine 37:1391–1397
20.
go back to reference Lazennec JV, Rousseau MA, Rangel A, Gorin M, Belicourt C, Brusson A, Catonne Y (2011) Pelvis and total hip arthroplasty acetabular component orientations in sitting and standing positions: Measurements reproductibility with EOS imaging system versus conventional radiographies. Orthop Traumatol Surg Res 97:373–380CrossRef Lazennec JV, Rousseau MA, Rangel A, Gorin M, Belicourt C, Brusson A, Catonne Y (2011) Pelvis and total hip arthroplasty acetabular component orientations in sitting and standing positions: Measurements reproductibility with EOS imaging system versus conventional radiographies. Orthop Traumatol Surg Res 97:373–380CrossRef
21.
go back to reference Lazennec JV, Brusson A, Dominique F, Rousseau MA, Pour AE (2014) Offset and anteversion reconstruction after cemented and uncemented total hip arthroplasty: an evaluation with the low-cost EOS system comparing two- and three-dimensional imaging. Int Orthop. 39(7):1259–1267 Jul 2015, 10.1007/s00264-014-2616-3 Lazennec JV, Brusson A, Dominique F, Rousseau MA, Pour AE (2014) Offset and anteversion reconstruction after cemented and uncemented total hip arthroplasty: an evaluation with the low-cost EOS system comparing two- and three-dimensional imaging. Int Orthop. 39(7):1259–1267 Jul 2015, 10.​1007/​s00264-014-2616-3
22.
go back to reference Folinais D, Thelen P, Delin C, Radier C, Catonne Y, Lazennec JY (2011) Measuring femoral and rotational alignment: EOS system versus computed tomography. Orthop Traumatol Surg Res 99:509–516CrossRef Folinais D, Thelen P, Delin C, Radier C, Catonne Y, Lazennec JY (2011) Measuring femoral and rotational alignment: EOS system versus computed tomography. Orthop Traumatol Surg Res 99:509–516CrossRef
23.
go back to reference Blendea S, Eckman K, Jaramaz B, Levison TJ, DiGioia III AM (2005) Measurements of acetabular cup position and pelvic spatial orientation after total hip arthroplasty using computed tomography/radiography matching. Comput Aided Surg 10:37–43 Blendea S, Eckman K, Jaramaz B, Levison TJ, DiGioia III AM (2005) Measurements of acetabular cup position and pelvic spatial orientation after total hip arthroplasty using computed tomography/radiography matching. Comput Aided Surg 10:37–43
24.
go back to reference Penney GP, Edwards PJ, Hipwell JH, Slomczykowski M, Revie I, Hawkes DJ (2007) Postoperative calculation of acetabular cup position using 2D–3D registration. IEEE Trans Biomed Eng 54:1342–1348 Penney GP, Edwards PJ, Hipwell JH, Slomczykowski M, Revie I, Hawkes DJ (2007) Postoperative calculation of acetabular cup position using 2D–3D registration. IEEE Trans Biomed Eng 54:1342–1348
25.
go back to reference Zheng G, Zhang X, Steppacher S, Murphy SB, Siebenrock KA, Tannast M (2009) HipMatch: an object-oriented cross-platform program for accurate determination of cup orientation using 2D-3D registration of single standard X-ray radiograph and a CT volume. Comput Methods Programs Biomed 95:236–248 Zheng G, Zhang X, Steppacher S, Murphy SB, Siebenrock KA, Tannast M (2009) HipMatch: an object-oriented cross-platform program for accurate determination of cup orientation using 2D-3D registration of single standard X-ray radiograph and a CT volume. Comput Methods Programs Biomed 95:236–248
26.
go back to reference Steffen S, Thelen B, Ballestra S, Nolte L-P, Buechler P, Zheng G (2014) X-ray image calibration and its application to clinical orthopedics. Med Eng Phys 36(7):968–974CrossRef Steffen S, Thelen B, Ballestra S, Nolte L-P, Buechler P, Zheng G (2014) X-ray image calibration and its application to clinical orthopedics. Med Eng Phys 36(7):968–974CrossRef
27.
go back to reference Hartley R, Zisserman A (2004) Multiple view geometry in computer vision, 2nd edn. Cambridge University Press, Cambridge Hartley R, Zisserman A (2004) Multiple view geometry in computer vision, 2nd edn. Cambridge University Press, Cambridge
28.
go back to reference Cootes TF, Taylor CJ, Cooper DH, Graham J (1995) Active shape models-their training and application. Comput Vis Image Underst 61:38–59 Cootes TF, Taylor CJ, Cooper DH, Graham J (1995) Active shape models-their training and application. Comput Vis Image Underst 61:38–59
29.
go back to reference Vercauteren T, Pennec X, Perchant A, Ayache N (2009) Diffeomorphic demons: efficient non-parametric image registration. Neuroimage 45(1 Suppl):S61–S72CrossRef Vercauteren T, Pennec X, Perchant A, Ayache N (2009) Diffeomorphic demons: efficient non-parametric image registration. Neuroimage 45(1 Suppl):S61–S72CrossRef
30.
go back to reference Lamecker H, Wenckebach TH, Hege H-C (2006) Atlas-based 3D-shape reconstruction from X-ray images. In: Proceedings of the 2006 international conference on pattern recognition 2006 (ICPR 2006). IEEE Computer Society, pp 371–374 Lamecker H, Wenckebach TH, Hege H-C (2006) Atlas-based 3D-shape reconstruction from X-ray images. In: Proceedings of the 2006 international conference on pattern recognition 2006 (ICPR 2006). IEEE Computer Society, pp 371–374
31.
go back to reference Mitton D, Deschenes S, Laporte S, Godbout B, Bertrand S, de Guise JA, Skalli W (2006) 3D reconstruction of the pelvis from bi-planar radiography. Comput Methods Biomech Biomed Eng 9:1–5 Mitton D, Deschenes S, Laporte S, Godbout B, Bertrand S, de Guise JA, Skalli W (2006) 3D reconstruction of the pelvis from bi-planar radiography. Comput Methods Biomech Biomed Eng 9:1–5
32.
go back to reference Kadoury S, Cheriet F, Dansereau J, Labelle H (2007) Three-dimensional reconstruction of the scoliotic spine and pelvis from uncalibrated biplanar X-ray images. J Spinal Disord Tech 20:160–167 Kadoury S, Cheriet F, Dansereau J, Labelle H (2007) Three-dimensional reconstruction of the scoliotic spine and pelvis from uncalibrated biplanar X-ray images. J Spinal Disord Tech 20:160–167
33.
go back to reference Zheng G, Gollmer S, Schumann S, Dong X, Feilkas T, and Gonzalez Ballester MA (2009) A 2D/3D correspondence building method for reconstruction of a patient-specific 3D bone surface model using point distribution models and calibrated X-ray images. Med. Image Anal. 13:883–899 Zheng G, Gollmer S, Schumann S, Dong X, Feilkas T, and Gonzalez Ballester MA (2009) A 2D/3D correspondence building method for reconstruction of a patient-specific 3D bone surface model using point distribution models and calibrated X-ray images. Med. Image Anal. 13:883–899
34.
go back to reference Schumann S, Liu L, Tannast M, Bergmann M, Nolte LP, Zheng G (2013) An integrated system for 3D hip joint reconstruction from 2D X-rays: a preliminary validation study. Annals of Biomecial Engineering 41:2077–2087 Schumann S, Liu L, Tannast M, Bergmann M, Nolte LP, Zheng G (2013) An integrated system for 3D hip joint reconstruction from 2D X-rays: a preliminary validation study. Annals of Biomecial Engineering 41:2077–2087
35.
go back to reference Balestra S (2013) Statistical shape model-based articulated 2D-3D reconstruction. Master thesis, Institute for Surgical Technology and Biomechanics, University of Bern, Switzerland Balestra S (2013) Statistical shape model-based articulated 2D-3D reconstruction. Master thesis, Institute for Surgical Technology and Biomechanics, University of Bern, Switzerland
Metadata
Title
2D-3D Reconstruction-Based Planning of Total Hip Arthroplasty
Authors
Guoyan Zheng
Steffen Schumann
Steven Balestra
Benedikt Thelen
Lutz-P. Nolte
Copyright Year
2016
DOI
https://doi.org/10.1007/978-3-319-23482-3_10