Skip to main content
Top
Published in: Optical and Quantum Electronics 1/2024

01-01-2024

A compact dual-band hybrid dielectric resonator antenna for blood glucose sensing and wireless communication

Authors: Piyush Kumar Mishra, Vijay Shanker Tripathi

Published in: Optical and Quantum Electronics | Issue 1/2024

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

This paper proposes a compact dielectric resonator-based high gain dual-band hybrid antenna. The antenna is proposed to work in a dual ISM (industrial, scientific, and medical) band, i.e., at 2.40\(-\)2.48 GHz and 5.725\(-\)5.875 GHz. The designed antenna can work as a radiator in the lower band (2.37\(-\)2.49 GHz) and as a sensor in the upper band (5.34\(-\)6.00 GHz). The non-invasive blood glucose sensing application is chosen at a higher frequency band, and a lower band is chosen for wireless communication. From a single transmission feed line, both frequency bands are generated by the fundamental mode \({TM_{10}}\) of radiating slot and \({HEM_{11}}\) mode inside cylindrical DRA, respectively. The designed antenna is optimized and simulated to get the best possible results in terms of S-parameter, bandwidth, gain, radiation pattern, efficiency in a lower band, and sensitivity toward blood permittivity in a higher band. This work performs regression analysis and fasting experiments for blood glucose sensing. The link budget analysis is also done at different data rates for wireless communication. The Specific absorption rate (SAR) value is calculated in finger tissue to ensure safety. The simulated and measured results of the designed antenna suggest that it can be used for non-invasive blood glucose sensing and wireless communication applications. To the author’s knowledge, no antenna was reported prior for radiating as well as sensing applications.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
go back to reference Balanis, C.A.: Antenna Theory: Analysis and Design. Wiley, Hoboken, NJ, USA (2016) Balanis, C.A.: Antenna Theory: Analysis and Design. Wiley, Hoboken, NJ, USA (2016)
go back to reference Bruen, D., Delaney, C., Florea, L., Diamond, D.: Glucose sensing for diabetes monitoring: recent developments, Sensors, vol. 17, no. 8, (2017) Bruen, D., Delaney, C., Florea, L., Diamond, D.: Glucose sensing for diabetes monitoring: recent developments, Sensors, vol. 17, no. 8, (2017)
go back to reference Cebedio, M.C., Rabioglio, L.A., Gelosi, I.E., Ribas, R.A., Uriz, A.J., Moreira, J.C.: Analysis and design of a microwave coplanar sensor for non-invasive blood glucose measurements. IEEE Sens. J. 20(18), 10572–10581 (2020)CrossRefADS Cebedio, M.C., Rabioglio, L.A., Gelosi, I.E., Ribas, R.A., Uriz, A.J., Moreira, J.C.: Analysis and design of a microwave coplanar sensor for non-invasive blood glucose measurements. IEEE Sens. J. 20(18), 10572–10581 (2020)CrossRefADS
go back to reference Cole, K.S., Cole, R.H.: Dispersion and absorption in dielectrics: I. Alternating current characteristics, J. Chem. Phys., vol. 9, (1941) Cole, K.S., Cole, R.H.: Dispersion and absorption in dielectrics: I. Alternating current characteristics, J. Chem. Phys., vol. 9, (1941)
go back to reference Ding, Y., Leung, K.W.: On the dual-band DRA-slot hybrid antenna. IEEE Trans. Antennas Propag. 57(3), 624–630 (2009)CrossRefADS Ding, Y., Leung, K.W.: On the dual-band DRA-slot hybrid antenna. IEEE Trans. Antennas Propag. 57(3), 624–630 (2009)CrossRefADS
go back to reference Gabriel, S., Lau, R.W., Gabriel, C.: The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. Phys. Med. Biol. 41(11), 2271–2293 (1996)CrossRefPubMed Gabriel, S., Lau, R.W., Gabriel, C.: The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. Phys. Med. Biol. 41(11), 2271–2293 (1996)CrossRefPubMed
go back to reference Gabriel, S., Lau, R.W. Gabriel, C.: The dielectric properties of biologicaltissue,Phys.Med.Biol.pp.2231-2293, (2004) Gabriel, S., Lau, R.W. Gabriel, C.: The dielectric properties of biologicaltissue,Phys.Med.Biol.pp.2231-2293, (2004)
go back to reference Hasan, Md N., Tamanna, S., Singh, Padam, N., Md, Rudramuni, M.: Cylindrical dielectric resonator antenna sensor for non-invasive glucose sensing application. 961-964. 10.1109/SPIN.2019.8711633 (2019) Hasan, Md N., Tamanna, S., Singh, Padam, N., Md, Rudramuni, M.: Cylindrical dielectric resonator antenna sensor for non-invasive glucose sensing application. 961-964. 10.1109/SPIN.2019.8711633 (2019)
go back to reference Hurt, W.D.: Multiterm Debye dispersion relations for permittivity of muscle, IEEE Trans. Biomed. Eng., vol. BME- 32, no. 1, pp. 60-64, (1985) Hurt, W.D.: Multiterm Debye dispersion relations for permittivity of muscle, IEEE Trans. Biomed. Eng., vol. BME- 32, no. 1, pp. 60-64, (1985)
go back to reference IEEE Standard for Safety Levels with Respect to Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 Hz to 300 GHz, in IEEE Std C95.1-2019 (Revision of IEEE Std C95.1-2005/ Incorporates IEEE Std C95.1-2019/Cor 1-2019) , vol., no., pp.1-312, 4 Oct. (2019), https://doi.org/10.1109/IEEESTD.2019.8859679. IEEE Standard for Safety Levels with Respect to Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 Hz to 300 GHz, in IEEE Std C95.1-2019 (Revision of IEEE Std C95.1-2005/ Incorporates IEEE Std C95.1-2019/Cor 1-2019) , vol., no., pp.1-312, 4 Oct. (2019), https://​doi.​org/​10.​1109/​IEEESTD.​2019.​8859679.​
go back to reference Iqbal, A., Alazemi, A.J., Khaddaj Mallat, N.: Slot-DRA-Based Independent Dual-Band Hybrid Antenna for Wearable Biomedical Devices, in IEEE Access, 7, pp. 184029-184037, (2019) Iqbal, A., Alazemi, A.J., Khaddaj Mallat, N.: Slot-DRA-Based Independent Dual-Band Hybrid Antenna for Wearable Biomedical Devices, in IEEE Access, 7, pp. 184029-184037, (2019)
go back to reference Jang, C., Park, J.K., Lee, H.J., Yun, G.H., Yook, J.G.: Temperature corrected fluidic glucose sensor based on microwave resonator, Sensors, vol. 18, no. 11, Nov. (2018) Jang, C., Park, J.K., Lee, H.J., Yun, G.H., Yook, J.G.: Temperature corrected fluidic glucose sensor based on microwave resonator, Sensors, vol. 18, no. 11, Nov. (2018)
go back to reference Keyrouz, S., Caratelli, D.: Dielectric Resonator Antennas: Basic Concepts, Design Guidelines, and Recent Developments at Millimeter-Wave Frequencies, International Journal of Antennas and Propagation, vol. 2016, Article ID 6075680, 20 pages, (2016) Keyrouz, S., Caratelli, D.: Dielectric Resonator Antennas: Basic Concepts, Design Guidelines, and Recent Developments at Millimeter-Wave Frequencies, International Journal of Antennas and Propagation, vol. 2016, Article ID 6075680, 20 pages, (2016)
go back to reference Kracolak, T., Moreland, E.C., Topsakal, E.: Cole-cole model for glucose-dependent dielectric properties of blood plasma for continuos glucose monitoring. Microw. Optical Tech. Lett. 55(5), 1160–1164 (2013)CrossRef Kracolak, T., Moreland, E.C., Topsakal, E.: Cole-cole model for glucose-dependent dielectric properties of blood plasma for continuos glucose monitoring. Microw. Optical Tech. Lett. 55(5), 1160–1164 (2013)CrossRef
go back to reference Lekha, S.: Real-time non-invasive detection and classification of diabetes using modified convolution neural network. IEEE J. Biomed. Health Inform. 22(5), 1630–1636 (2017)CrossRefPubMed Lekha, S.: Real-time non-invasive detection and classification of diabetes using modified convolution neural network. IEEE J. Biomed. Health Inform. 22(5), 1630–1636 (2017)CrossRefPubMed
go back to reference Li, Y., Lu, Z., Yang, L.: CPW-fed slot antenna for medical wearable applications. IEEE Access 7, 42107–42112 (2019)CrossRef Li, Y., Lu, Z., Yang, L.: CPW-fed slot antenna for medical wearable applications. IEEE Access 7, 42107–42112 (2019)CrossRef
go back to reference Lin, Tamar, Gal, Avner, Mayzel, Yulia, Horman, Keren, Bahartan, Karnit: Non-invasive glucose monitoring: a review of challenges and recent advances. Curr Trends Biomedical Eng & Biosci 6(5), 1–8 (2017)CrossRef Lin, Tamar, Gal, Avner, Mayzel, Yulia, Horman, Keren, Bahartan, Karnit: Non-invasive glucose monitoring: a review of challenges and recent advances. Curr Trends Biomedical Eng & Biosci 6(5), 1–8 (2017)CrossRef
go back to reference Lin, Tamar, Gal, Avner, Mayzel, Yulia, Horman, Keren, Bahartan, Karnit: Non-invasive glucose monitoring: a review of challenges and recent advances. Curr Trends Biomedical Eng and Biosci 6(5), 1–8 (2017)CrossRef Lin, Tamar, Gal, Avner, Mayzel, Yulia, Horman, Keren, Bahartan, Karnit: Non-invasive glucose monitoring: a review of challenges and recent advances. Curr Trends Biomedical Eng and Biosci 6(5), 1–8 (2017)CrossRef
go back to reference Liu, Y.-X.G., Xiao, S.: Capacitively loaded circularly polarized implantable patch antenna for ISM band biomedical applications. IEEE Trans. Antennas Propag. 62(5), 2407–2417 (2014)CrossRefADS Liu, Y.-X.G., Xiao, S.: Capacitively loaded circularly polarized implantable patch antenna for ISM band biomedical applications. IEEE Trans. Antennas Propag. 62(5), 2407–2417 (2014)CrossRefADS
go back to reference Navaei, M., Rezaei, P., Kiani, S.: Measurement of low-loss aqueous solutions permittivity with high detection accuracy by a contact and free-label resonance microwave sensor. Int. J. Commun Syst 36, e5417 (2023)CrossRef Navaei, M., Rezaei, P., Kiani, S.: Measurement of low-loss aqueous solutions permittivity with high detection accuracy by a contact and free-label resonance microwave sensor. Int. J. Commun Syst 36, e5417 (2023)CrossRef
go back to reference Petosa, A., Ittipiboon, A., Antar, Y.M.M., Roscoe, D., Cuhasi, M.: Recent advances in dielectric-resonator antenna technology. IEEE Antennas Propag. Mag. 40(3), 35–48 (1998)CrossRefADS Petosa, A., Ittipiboon, A., Antar, Y.M.M., Roscoe, D., Cuhasi, M.: Recent advances in dielectric-resonator antenna technology. IEEE Antennas Propag. Mag. 40(3), 35–48 (1998)CrossRefADS
go back to reference Sethi, W.T., Ashraf, M.A., Alshebeili, S.A., Issa, K.: Thumb positioning analysis of new elliptical-shaped microwave sensors for non-invasive glucose monitoring , IEEE ELECTRONICS LETTERS 3rd May (2018) Vol. 54 No. 9 pp. 553-554 Sethi, W.T., Ashraf, M.A., Alshebeili, S.A., Issa, K.: Thumb positioning analysis of new elliptical-shaped microwave sensors for non-invasive glucose monitoring , IEEE ELECTRONICS LETTERS 3rd May (2018) Vol. 54 No. 9 pp. 553-554
go back to reference Sharma, A., Sarkar, A., Biswas, A., Akhtar, M.J.: Compact dual-band hybrid dielectric resonator antenna loaded with magnetic-LC resonator. J. Electromagn. Appl. 32(10), 1298–1305 (2018)CrossRef Sharma, A., Sarkar, A., Biswas, A., Akhtar, M.J.: Compact dual-band hybrid dielectric resonator antenna loaded with magnetic-LC resonator. J. Electromagn. Appl. 32(10), 1298–1305 (2018)CrossRef
go back to reference Tajima, T., Okabe, Y., Tanaka, Y., Seyama, M.: Linearization technique for dual-wavelength CW photoacoustic detection of glucose. IEEE Sens. J. 17(16), 5079–5086 (2017)CrossRefADS Tajima, T., Okabe, Y., Tanaka, Y., Seyama, M.: Linearization technique for dual-wavelength CW photoacoustic detection of glucose. IEEE Sens. J. 17(16), 5079–5086 (2017)CrossRefADS
go back to reference Topsakal, E., Karacolak, T., Moreland, E.C.: Glucose dependent dielectric properties of blood plasma, 2011 XXXth URSI General Assembly and Scientific Symposium, Istanbul, pp. 1-4, (2011) Topsakal, E., Karacolak, T., Moreland, E.C.: Glucose dependent dielectric properties of blood plasma, 2011 XXXth URSI General Assembly and Scientific Symposium, Istanbul, pp. 1-4, (2011)
go back to reference Turgul, V., Kale, I.: Simulating the effects of skin thickness and fingerprints to highlight problems with non-invasive rf blood glucose sensing from fingertips. IEEE Sens. J. 17(22), 7553–7560 (2017)CrossRefADS Turgul, V., Kale, I.: Simulating the effects of skin thickness and fingerprints to highlight problems with non-invasive rf blood glucose sensing from fingertips. IEEE Sens. J. 17(22), 7553–7560 (2017)CrossRefADS
go back to reference Valeri, C., Pozzilli, P., Leslie, D.: Glucose control in diabetes. Diabetes Metab. Res. Rev. 20(S2), S1–S8 (2004)CrossRefPubMed Valeri, C., Pozzilli, P., Leslie, D.: Glucose control in diabetes. Diabetes Metab. Res. Rev. 20(S2), S1–S8 (2004)CrossRefPubMed
go back to reference Xiao, Xia: Member, IEEE, and Qinwei Li, A non-invasive measurement of blood glucose concentration by uwb microwave spectrum. IEEE Antennas Wirel. Propag. Lett. 16, 1040–1043 (2017)CrossRefADS Xiao, Xia: Member, IEEE, and Qinwei Li, A non-invasive measurement of blood glucose concentration by uwb microwave spectrum. IEEE Antennas Wirel. Propag. Lett. 16, 1040–1043 (2017)CrossRefADS
go back to reference Yilmaz, T., Foster, R., Hao, Y.: Radio-frequency and microwave techniques for non-invasive measurement of blood glucose levels, Diagnostics, vol. 9, no. 1, (2019) Yilmaz, T., Foster, R., Hao, Y.: Radio-frequency and microwave techniques for non-invasive measurement of blood glucose levels, Diagnostics, vol. 9, no. 1, (2019)
go back to reference Yunos, M.F.A.M., Manczak, R., Guines, C., Mansor, A.F.M., Mak, W.C., Khan, S., Ramli, N.A., Pothier, A., Nordin, A.N.: RF Remote blood glucose sensor and a microfluidic vascular phantom for sensor validation. Biosensors (Basel). (2021) ;11(12):494. https://doi.org/10.3390/bios11120494.PMID: 34940251; PMCID: PMC8699327 Yunos, M.F.A.M., Manczak, R., Guines, C., Mansor, A.F.M., Mak, W.C., Khan, S., Ramli, N.A., Pothier, A., Nordin, A.N.: RF Remote blood glucose sensor and a microfluidic vascular phantom for sensor validation. Biosensors (Basel). (2021) ;11(12):494. https://​doi.​org/​10.​3390/​bios11120494.​PMID: 34940251; PMCID: PMC8699327
Metadata
Title
A compact dual-band hybrid dielectric resonator antenna for blood glucose sensing and wireless communication
Authors
Piyush Kumar Mishra
Vijay Shanker Tripathi
Publication date
01-01-2024
Publisher
Springer US
Published in
Optical and Quantum Electronics / Issue 1/2024
Print ISSN: 0306-8919
Electronic ISSN: 1572-817X
DOI
https://doi.org/10.1007/s11082-023-05579-x

Other articles of this Issue 1/2024

Optical and Quantum Electronics 1/2024 Go to the issue