Skip to main content
Top
Published in: Microsystem Technologies 6/2015

01-06-2015 | Technical Paper

A flexible dry micro-dome electrode for ECG monitoring

Authors: Ying Meng, Zhen Bo Li, Xiang Chen, Jia Pin Chen

Published in: Microsystem Technologies | Issue 6/2015

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

This paper describes a flexible dry electrode with micro domes on polydimethylsiloxane (PDMS) for the monitoring of electrocardiogram (ECG). The fabrication procedure of this microstructure was mainly composed of melting photoresist, double-PDMS-molding, nickel (Ni) plating and encapsulation between two thin PDMS films. To investigate the performance of the fabricated micro-dome electrode, three dry electrodes with different arrays were fabricated to conduct the contact impendence measurements. ECG signals were measured by both the standard wet electrodes (Ag/AgCl) and dry electrodes. Experimental results showed the dry electrode provided signal quality that was comparable to the standard wet electrode without the need for skin preparation or electrolytic solution. The proposed dry electrode is more comfortable, with less skin irritation and requires no conductive gel. Thus, this flexible dry micro-dome electrode could find potential biomedical applications in health monitoring.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
go back to reference Baek JY, Kwon GH, An JH et al (2007) Bi-axial stretchable electrode based on the thin PDMS substrate for the biomedical applications. Mater Sci Forum 544–545:665–668CrossRef Baek JY, Kwon GH, An JH et al (2007) Bi-axial stretchable electrode based on the thin PDMS substrate for the biomedical applications. Mater Sci Forum 544–545:665–668CrossRef
go back to reference Baek JY, An JH, Choi JM et al (2008) Flexible polymeric dry electrodes for the long-term monitoring of ECG. Sens Actuators A 143(2):423–429CrossRef Baek JY, An JH, Choi JM et al (2008) Flexible polymeric dry electrodes for the long-term monitoring of ECG. Sens Actuators A 143(2):423–429CrossRef
go back to reference Chen CY, Chang CL, Chang CW et al (2013) A low-power bio-potential acquisition system with flexible PDMS dry electrodes for portable ubiquitous healthcare applications. Sensors 13:3077–3091CrossRef Chen CY, Chang CL, Chang CW et al (2013) A low-power bio-potential acquisition system with flexible PDMS dry electrodes for portable ubiquitous healthcare applications. Sensors 13:3077–3091CrossRef
go back to reference Fordyce PM, Diaz-Botia CA, DeRisi JL et al (2012) Systematic characterization of feature dimensions and closing pressures for microfluidic valves produced via photoresist reflow. Lab Chip 12(21):4287–4295CrossRef Fordyce PM, Diaz-Botia CA, DeRisi JL et al (2012) Systematic characterization of feature dimensions and closing pressures for microfluidic valves produced via photoresist reflow. Lab Chip 12(21):4287–4295CrossRef
go back to reference Grand L, Wittner L, Herwik S et al (2010) Short and long term biocompatibility of NeuroProbes silicon probes. J Neurosci Meth 189:216–229CrossRef Grand L, Wittner L, Herwik S et al (2010) Short and long term biocompatibility of NeuroProbes silicon probes. J Neurosci Meth 189:216–229CrossRef
go back to reference Hassanin H, Mohammadkhani A, Jiang K (2012) Fabrication of hybrid nanostructured arrays using a PDMS/PDMS replication process. Lab Chip 12(20):4160–4167CrossRef Hassanin H, Mohammadkhani A, Jiang K (2012) Fabrication of hybrid nanostructured arrays using a PDMS/PDMS replication process. Lab Chip 12(20):4160–4167CrossRef
go back to reference Hoffmann KP, Ruff R (2007) Flexible dry surface-electrodes for ECG long-term monitoring. In: Engineering in medicine and biology society, EMBS 2007. 29th Annual international conference of the IEEE, pp 5739–5742 Hoffmann KP, Ruff R (2007) Flexible dry surface-electrodes for ECG long-term monitoring. In: Engineering in medicine and biology society, EMBS 2007. 29th Annual international conference of the IEEE, pp 5739–5742
go back to reference Jung HC, Moon JH, Baek DH et al (2012) CNT/PDMS composite flexible dry electrodes for long-term ECG monitoring. IEEE Trans Biomed Eng 59(5):1472–1479CrossRef Jung HC, Moon JH, Baek DH et al (2012) CNT/PDMS composite flexible dry electrodes for long-term ECG monitoring. IEEE Trans Biomed Eng 59(5):1472–1479CrossRef
go back to reference Kanga MG, Parkb HJ, Ahnc SH et al (2010) Transparent Cu nanowire mesh electrode on flexible substrates fabricated by transfer printing and its application in organic solar cells. Sol Energy Mater Sol Cell 94(6):1179–1184CrossRef Kanga MG, Parkb HJ, Ahnc SH et al (2010) Transparent Cu nanowire mesh electrode on flexible substrates fabricated by transfer printing and its application in organic solar cells. Sol Energy Mater Sol Cell 94(6):1179–1184CrossRef
go back to reference Lee KK, He J, Singh A, Massia S et al (2004) Polyimide based neural implants with stiffness improvement. Sens Actuators B 102(1):67–72CrossRef Lee KK, He J, Singh A, Massia S et al (2004) Polyimide based neural implants with stiffness improvement. Sens Actuators B 102(1):67–72CrossRef
go back to reference Lee JH, Nam YW, Jung HC et al (2012) Shear induced CNT/PDMS conducting thin film for electrode cardiogram (ECG) electrode. BioChip J 6:91–98CrossRef Lee JH, Nam YW, Jung HC et al (2012) Shear induced CNT/PDMS conducting thin film for electrode cardiogram (ECG) electrode. BioChip J 6:91–98CrossRef
go back to reference Liu H, Tao X, Xu P et al (2013) A dynamic measurement system for evaluating dry bio-potential surface electrodes. Measurement 46(6):1904–1913CrossRef Liu H, Tao X, Xu P et al (2013) A dynamic measurement system for evaluating dry bio-potential surface electrodes. Measurement 46(6):1904–1913CrossRef
go back to reference Martin RS, Gawron AJ, Lunte SM et al (2000) Dual-electrode electrochemical detection for poly (dimethylsiloxane)-fabricated capillary electrophoresis microchips. Anal Chem 72(14):3196–3202CrossRef Martin RS, Gawron AJ, Lunte SM et al (2000) Dual-electrode electrochemical detection for poly (dimethylsiloxane)-fabricated capillary electrophoresis microchips. Anal Chem 72(14):3196–3202CrossRef
go back to reference Ng WC, Seet HL, Lee KS et al (2009) Microspike EEG electrode and the vacuum-casting technology for mass production. J Mater Process Technol 209:4434–4438CrossRef Ng WC, Seet HL, Lee KS et al (2009) Microspike EEG electrode and the vacuum-casting technology for mass production. J Mater Process Technol 209:4434–4438CrossRef
go back to reference O’Gorman JG, Jamieson RD (1975) The incremental stimulus intensity effect and habituation of autonomic responses in man. Physiol Psychol 3(4):385–389CrossRef O’Gorman JG, Jamieson RD (1975) The incremental stimulus intensity effect and habituation of autonomic responses in man. Physiol Psychol 3(4):385–389CrossRef
go back to reference Oder TN, Shakya J, Lin JY et al (2003) Nitride microlens arrays for blue and ultraviolet wavelength applications. Appl Phys Lett 82(21):3692–3694CrossRef Oder TN, Shakya J, Lin JY et al (2003) Nitride microlens arrays for blue and ultraviolet wavelength applications. Appl Phys Lett 82(21):3692–3694CrossRef
go back to reference Popovic Z, Sprague R, Neville Connell G (1988) Technique for monolithic fabrication of microlens arrays. Appl Opt 27:1281–1284CrossRef Popovic Z, Sprague R, Neville Connell G (1988) Technique for monolithic fabrication of microlens arrays. Appl Opt 27:1281–1284CrossRef
go back to reference Salvo P, Raedt R, Carrette E et al (2012) A 3D printed dry electrode for ECG/EEG recording. Sens Actuators A 174:96–102CrossRef Salvo P, Raedt R, Carrette E et al (2012) A 3D printed dry electrode for ECG/EEG recording. Sens Actuators A 174:96–102CrossRef
go back to reference Simionca IM, Arvinte A, Ardeleanu R et al (2012) Siloxane-crown ether polyamide based electrode for electrochemical determination of lead(II) in aqueous solution. Electroanal 24(10):1995–2004CrossRef Simionca IM, Arvinte A, Ardeleanu R et al (2012) Siloxane-crown ether polyamide based electrode for electrochemical determination of lead(II) in aqueous solution. Electroanal 24(10):1995–2004CrossRef
go back to reference Takeuchi S, Ziegler DM, Yoshida Y et al (2005) Parylene flexible neural probes integrated with microfluidic channels. Lab Chip 5(5):519–523CrossRef Takeuchi S, Ziegler DM, Yoshida Y et al (2005) Parylene flexible neural probes integrated with microfluidic channels. Lab Chip 5(5):519–523CrossRef
go back to reference Thompson CS, Abate AR (2013) Adhesive-based bonding technique for PDMS microfluidic devices. Lab Chip 13(4):632–635CrossRef Thompson CS, Abate AR (2013) Adhesive-based bonding technique for PDMS microfluidic devices. Lab Chip 13(4):632–635CrossRef
go back to reference Wang LF, Liu JQ, Yang B et al (2012) PDMS-based low cost flexible dry electrode for long-term EEG measurement. Sens J IEEE 12(9):2898–2904CrossRef Wang LF, Liu JQ, Yang B et al (2012) PDMS-based low cost flexible dry electrode for long-term EEG measurement. Sens J IEEE 12(9):2898–2904CrossRef
go back to reference Yu LM, Tay FEH, Guo DG et al (2009) A microfabricated electrode with hollow microneedles for ECG measurement. Sens Actuators A 151(1):17–22CrossRef Yu LM, Tay FEH, Guo DG et al (2009) A microfabricated electrode with hollow microneedles for ECG measurement. Sens Actuators A 151(1):17–22CrossRef
Metadata
Title
A flexible dry micro-dome electrode for ECG monitoring
Authors
Ying Meng
Zhen Bo Li
Xiang Chen
Jia Pin Chen
Publication date
01-06-2015
Publisher
Springer Berlin Heidelberg
Published in
Microsystem Technologies / Issue 6/2015
Print ISSN: 0946-7076
Electronic ISSN: 1432-1858
DOI
https://doi.org/10.1007/s00542-014-2235-3

Other articles of this Issue 6/2015

Microsystem Technologies 6/2015 Go to the issue