Skip to main content
Top
Published in: Measurement Techniques 2/2013

01-05-2013 | Electromagnetic Measurements

A method of measuring the integral characteristics of a signal

Author: P. B. Petrovic

Published in: Measurement Techniques | Issue 2/2013

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

A new method of measuring active power and the effective (root mean square) value of alternating signals in half the time required by other existing methods, is proposed. The measurement is made by simple summation of samples of the instantaneous power without adjusting the measurement time depending on the signal frequency. Mathematical modeling enables the accuracy of the proposed algorithm to be estimated.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Footnotes
1
According to the State Standard GOST R 54149-2010 “Electric power. Compatibility of technical electromagnetic instruments. Standards of electric power quality in electric power supply systems for general use” only the first 40 harmonics are standardized (ed. note).
 
2
According to GOST R 54149-2010 (see footnote 1), a deviation of up to 5 Hz is permitted in isolated systems with autonomous generator equipment and 0.4 Hz in synchronized power supply systems (ed. note).
 
3
According to GOST R 54149-2010, the short-term dose of flicker P st should not exceed values of 1.38 (ed. note).
 
Literature
1.
go back to reference J. J. Clarke and J. R. Stockton, “Principles and theory of wattmeters operating on the basis of regularly spaced sample pairs,” J. Phys. E: Sci. Instrum., 15, 645–652 (1982).ADSCrossRef J. J. Clarke and J. R. Stockton, “Principles and theory of wattmeters operating on the basis of regularly spaced sample pairs,” J. Phys. E: Sci. Instrum., 15, 645–652 (1982).ADSCrossRef
2.
go back to reference P. Petrovic and M. Stevanovic, Digital Processing and Reconstruction of Complex AC Signals, Springer, New York (2009). P. Petrovic and M. Stevanovic, Digital Processing and Reconstruction of Complex AC Signals, Springer, New York (2009).
3.
go back to reference IEC 50160, Voltage Characteristics of Electricity Supplied by Public Distribution Networks (2011). IEC 50160, Voltage Characteristics of Electricity Supplied by Public Distribution Networks (2011).
4.
go back to reference L. P. Kunjumuhammed and M. K. Mishra, “A control algorithm for single-phase active power filter under non-stiff voltage source,” IEEE Trans. Power Electronics, 21, No. 3, 822–825 (2006).CrossRef L. P. Kunjumuhammed and M. K. Mishra, “A control algorithm for single-phase active power filter under non-stiff voltage source,” IEEE Trans. Power Electronics, 21, No. 3, 822–825 (2006).CrossRef
5.
go back to reference O. Martens et al., “DSP-based power quality monitoring device,” IEEE Int. Symp. Intelligent Signal Proc., 1–5 (2008). O. Martens et al., “DSP-based power quality monitoring device,” IEEE Int. Symp. Intelligent Signal Proc., 1–5 (2008).
6.
go back to reference H. Hindersah et al., “Prototype development of single phase prepaid KWh meter,” Proc. Int. Conf. Electrical Engineering and Informatics (2011), pp. 1–6. H. Hindersah et al., “Prototype development of single phase prepaid KWh meter,” Proc. Int. Conf. Electrical Engineering and Informatics (2011), pp. 1–6.
7.
go back to reference W. Jiekang, L. Jun, and W. Jixiang, “High-accuracy, wide-range frequency estimation methods for power system signals under nonsinusoidal conditions,” IEEE Trans. Power Del., 20, No. 1, 366–374 (2005).CrossRef W. Jiekang, L. Jun, and W. Jixiang, “High-accuracy, wide-range frequency estimation methods for power system signals under nonsinusoidal conditions,” IEEE Trans. Power Del., 20, No. 1, 366–374 (2005).CrossRef
8.
go back to reference M. D. Kuseljevic, “A simultaneous estimation of frequency, magnitude, and active and reactive power by using decoupled modules,” IEEE Trans. Instrum. Meas., 59, No. 7, 1866–1873 (2010).CrossRef M. D. Kuseljevic, “A simultaneous estimation of frequency, magnitude, and active and reactive power by using decoupled modules,” IEEE Trans. Instrum. Meas., 59, No. 7, 1866–1873 (2010).CrossRef
10.
go back to reference Y. S. Poberezhskiy and G. Y. Poberezhskiy, “Sampling and signal reconstruction circuits performing internal antialiasing filtering and their influence on the design of digital receivers and transmitters,” IEEE Trans. Circuits and Systems-1, 51, No. 1, 118–129 (2004).CrossRef Y. S. Poberezhskiy and G. Y. Poberezhskiy, “Sampling and signal reconstruction circuits performing internal antialiasing filtering and their influence on the design of digital receivers and transmitters,” IEEE Trans. Circuits and Systems-1, 51, No. 1, 118–129 (2004).CrossRef
11.
go back to reference Guide to the Expression of Uncertainty in Measurement, ISO, Geneva (1993). Guide to the Expression of Uncertainty in Measurement, ISO, Geneva (1993).
12.
go back to reference IEC 50160, Voltage Characteristics of Electricity Supplied by Public Distribution Networks (2011). IEC 50160, Voltage Characteristics of Electricity Supplied by Public Distribution Networks (2011).
13.
go back to reference H. Z. Hoseini, I. Kale, and O. Shoaei, “Modeling of switched-capacitor delta-sigma modulators in SIMULINK,” IEEE Trans. Instrum. Meas., 54, No. 4, 1646–1654 (2005).CrossRef H. Z. Hoseini, I. Kale, and O. Shoaei, “Modeling of switched-capacitor delta-sigma modulators in SIMULINK,” IEEE Trans. Instrum. Meas., 54, No. 4, 1646–1654 (2005).CrossRef
14.
go back to reference P. Petrovic, “New digital multimeter for accurate measurement of synchronously sampled AC signals,” IEEE Trans. Instrum. Meas., 53, No. 3, 716–725 (2004).MathSciNetCrossRef P. Petrovic, “New digital multimeter for accurate measurement of synchronously sampled AC signals,” IEEE Trans. Instrum. Meas., 53, No. 3, 716–725 (2004).MathSciNetCrossRef
15.
go back to reference K. J. Coakley et al., “Adaptive characterization of jitter noise in sampled high-speed signals,” IEEE Trans. Instrum. Meas., 52, No. 5, 1537–1547 (2003).CrossRef K. J. Coakley et al., “Adaptive characterization of jitter noise in sampled high-speed signals,” IEEE Trans. Instrum. Meas., 52, No. 5, 1537–1547 (2003).CrossRef
16.
go back to reference G. Vendersteen and R. Pintelon, “Maximum likelihood estimator for jitter noise models,” IEEE Trans. Instrum. Meas., 49, No. 6, 1282–1284 (2000).CrossRef G. Vendersteen and R. Pintelon, “Maximum likelihood estimator for jitter noise models,” IEEE Trans. Instrum. Meas., 49, No. 6, 1282–1284 (2000).CrossRef
17.
go back to reference H. Germer, “High-precision ac measurements using the Monte Carlo method,” IEEE Trans. Instrum. Meas., 50, No. 5, 457–460 (2001).CrossRef H. Germer, “High-precision ac measurements using the Monte Carlo method,” IEEE Trans. Instrum. Meas., 50, No. 5, 457–460 (2001).CrossRef
19.
go back to reference H. Hindersah et al., “Prototype development of single phase prepaid KWh meter,” Int. Conf. Electrical Engineering and Informatics (2011), pp. 1–6. H. Hindersah et al., “Prototype development of single phase prepaid KWh meter,” Int. Conf. Electrical Engineering and Informatics (2011), pp. 1–6.
20.
go back to reference J. C. Asquerino et al., “Measurement of apparent power components in the frequency domain,” IEEE Trans. Instrum. Meas., 39, No. 4, 583–587 (1990).CrossRef J. C. Asquerino et al., “Measurement of apparent power components in the frequency domain,” IEEE Trans. Instrum. Meas., 39, No. 4, 583–587 (1990).CrossRef
21.
go back to reference A. Odzemir and A. Ferikoglu, “Low cost mixed-signal microcontroller based power measurement technique,” IEE Proc. Sci. Meas. and Technol., 151, No. 4, 253–258 (2004).CrossRef A. Odzemir and A. Ferikoglu, “Low cost mixed-signal microcontroller based power measurement technique,” IEE Proc. Sci. Meas. and Technol., 151, No. 4, 253–258 (2004).CrossRef
Metadata
Title
A method of measuring the integral characteristics of a signal
Author
P. B. Petrovic
Publication date
01-05-2013
Publisher
Springer US
Published in
Measurement Techniques / Issue 2/2013
Print ISSN: 0543-1972
Electronic ISSN: 1573-8906
DOI
https://doi.org/10.1007/s11018-013-0178-1

Other articles of this Issue 2/2013

Measurement Techniques 2/2013 Go to the issue