Skip to main content
Top
Published in: Neural Computing and Applications 8/2020

06-10-2018 | Original Article

A novel online method for identifying motion artifact and photoplethysmography signal reconstruction using artificial neural networks and adaptive neuro-fuzzy inference system

Authors: Bahram Tarvirdizadeh, Alireza Golgouneh, Farzam Tajdari, Erfan Khodabakhshi

Published in: Neural Computing and Applications | Issue 8/2020

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Photoplethysmography (PPG) is a noninvasive technique to measure blood volume changes in blood vessels. Despite the wide usage of PPG signal in medical and non-medical applications, this signal can be affected by the motion artifacts leading to data loss. In this paper, we proposed an algorithm to detect motion artifacts and reconstruct the corrupted parts of the signal using real-time modeling based on multilayer perceptron (MLP), radial basis function (RBF) artificial neural networks (ANNs) and adaptive-neuro fuzzy inference system (ANFIS). The developed algorithm was applied to reconstruct the corrupted parts of PPG signals of 23 healthy 25- to 28-year-old volunteers. In the experimental phase, the left- and right-hand PPG signals of the volunteers were simultaneously obtained. While the left hand of the subjects were fixed, they were asked to shake their hands without any predetermined pattern, to simulate the real-life motion accelerations. To statistically and physiologically evaluate the performance of the proposed models, Pearson correlation coefficient (PCC), intraclass correlation coefficient (ICC), Bland–Altman plot (with the 95% limits of agreement), and time-domain feature analysis tests were adopted. The results indicated that the ANFIS with subtractive clustering algorithm shows the best performance in modeling the lost parts of the right-hand signals with an average PCC and ICC of 0.80 and 0.77, respectively, with the reference signal (left-hand signals) over all the tests. Also, the proposed ANFIS-based algorithm had an ability to retrieve the important time-domain PPG signal features, namely mean of inter-beat intervals (NN), standard deviations of NN (SDNN), root mean square of standard deviations (RMSSD) and standard deviation of standard deviations (SDSD) without any significant difference at p < 0.05 level to those of the reference signal (left-hand signal).

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Teng XF, Zhang YT (2003) Study on the peak interval variability of photoplethysmogtaphic signals. In: IEEE EMBS Asian-Pacific conference on biomedical engineering, 2003, pp 140–141 Teng XF, Zhang YT (2003) Study on the peak interval variability of photoplethysmogtaphic signals. In: IEEE EMBS Asian-Pacific conference on biomedical engineering, 2003, pp 140–141
2.
go back to reference Selvaraj N, Santhosh J, Anand S (2007) Feasibility of photoplethymographic signal for assessment of autonomic response using heart rate variability analysis. In: 3rd Kuala Lumpur international conference on biomedical engineering 2006, pp 391–395 Selvaraj N, Santhosh J, Anand S (2007) Feasibility of photoplethymographic signal for assessment of autonomic response using heart rate variability analysis. In: 3rd Kuala Lumpur international conference on biomedical engineering 2006, pp 391–395
3.
go back to reference Johnston W, Mendelson Y (2005) Extracting heart rate variability from a wearable reflectance pulse oximeter. In: Proceedings of the IEEE 31st annual northeast bioengineering conference, 2005, pp 157–158 Johnston W, Mendelson Y (2005) Extracting heart rate variability from a wearable reflectance pulse oximeter. In: Proceedings of the IEEE 31st annual northeast bioengineering conference, 2005, pp 157–158
4.
go back to reference Bolanos M, Nazeran H, Haltiwanger E (2006) Comparison of heart rate variability signal features derived from electrocardiography and photoplethysmography in healthy individuals. In: 28th Annual international conference of the IEEE engineering in medicine and biology society, 2006, EMBS’06, pp 4289–4294 Bolanos M, Nazeran H, Haltiwanger E (2006) Comparison of heart rate variability signal features derived from electrocardiography and photoplethysmography in healthy individuals. In: 28th Annual international conference of the IEEE engineering in medicine and biology society, 2006, EMBS’06, pp 4289–4294
5.
go back to reference Sukor JA, Redmond SJ, Lovell NH (2011) Signal quality measures for pulse oximetry through waveform morphology analysis. Physiol Meas 32(3):369 Sukor JA, Redmond SJ, Lovell NH (2011) Signal quality measures for pulse oximetry through waveform morphology analysis. Physiol Meas 32(3):369
6.
go back to reference Kunchon S, Desudchit T, Chinrungrueng C (2009) Comparative evaluation of adaptive filters in motion artifact cancellation for pulse oximetry. In: 5th International colloquium on signal processing & its applications, 2009. CSPA 2009, pp 307–311 Kunchon S, Desudchit T, Chinrungrueng C (2009) Comparative evaluation of adaptive filters in motion artifact cancellation for pulse oximetry. In: 5th International colloquium on signal processing & its applications, 2009. CSPA 2009, pp 307–311
7.
go back to reference Graybeal JM, Petterson MT (2004) Adaptive filtering and alternative calculations revolutionizes pulse oximetry sensitivity and specificity during motion and low perfusion. In: 26th Annual international conference of the IEEE engineering in medicine and biology society, 2004. IEMBS’04, vol 2, pp 5363–5366 Graybeal JM, Petterson MT (2004) Adaptive filtering and alternative calculations revolutionizes pulse oximetry sensitivity and specificity during motion and low perfusion. In: 26th Annual international conference of the IEEE engineering in medicine and biology society, 2004. IEMBS’04, vol 2, pp 5363–5366
8.
go back to reference Foo JYA, Wilson SJ (2006) A computational system to optimise noise rejection in photoplethysmography signals during motion or poor perfusion states. Med Biol Eng Comput 44(1–2):140–145 Foo JYA, Wilson SJ (2006) A computational system to optimise noise rejection in photoplethysmography signals during motion or poor perfusion states. Med Biol Eng Comput 44(1–2):140–145
9.
go back to reference Harris R, Chabries D, Bishop F (1986) A variable step (VS) adaptive filter algorithm. IEEE Trans Acoust 34(2):309–316 Harris R, Chabries D, Bishop F (1986) A variable step (VS) adaptive filter algorithm. IEEE Trans Acoust 34(2):309–316
10.
go back to reference Evans JB, Liu B (1987) Variable step size methods for the LMS adaptive algorithm. In: Proceedings of the IEEE international symposium on circuits and systems, 1987, vol 2, pp 422–425 Evans JB, Liu B (1987) Variable step size methods for the LMS adaptive algorithm. In: Proceedings of the IEEE international symposium on circuits and systems, 1987, vol 2, pp 422–425
11.
go back to reference Chan KW, Zhang YT (2002) Adaptive reduction of motion artifact from photoplethysmographic recordings using a variable step-size LMS filter. In: Proceedings of IEEE sensors, 2002, vol. 2, pp. 1343–1346 Chan KW, Zhang YT (2002) Adaptive reduction of motion artifact from photoplethysmographic recordings using a variable step-size LMS filter. In: Proceedings of IEEE sensors, 2002, vol. 2, pp. 1343–1346
12.
go back to reference Seyedtabaii S, Seyedtabaii L (2008) Kalman filter based adaptive reduction of motion artifact from photoplethysmographic signal. World Acad Sci Eng Technol 37:173–176 Seyedtabaii S, Seyedtabaii L (2008) Kalman filter based adaptive reduction of motion artifact from photoplethysmographic signal. World Acad Sci Eng Technol 37:173–176
13.
go back to reference Yan Y, Poon CCY, Zhang Y (2005) Reduction of motion artifact in pulse oximetry by smoothed pseudo Wigner–Ville distribution. J Neuroeng Rehabil 2(1):1 Yan Y, Poon CCY, Zhang Y (2005) Reduction of motion artifact in pulse oximetry by smoothed pseudo Wigner–Ville distribution. J Neuroeng Rehabil 2(1):1
14.
go back to reference Reddy KA, George B, Kumar VJ (2008) Motion artifact reduction and data compression of photoplethysmo-graphic signals utilizing cycle by cycle fourier series analysis. In: Instrumentation and measurement technology conference proceedings, 2008. IMTC 2008. IEEE, 2008, pp 176–179 Reddy KA, George B, Kumar VJ (2008) Motion artifact reduction and data compression of photoplethysmo-graphic signals utilizing cycle by cycle fourier series analysis. In: Instrumentation and measurement technology conference proceedings, 2008. IMTC 2008. IEEE, 2008, pp 176–179
15.
go back to reference Kim BS, Yoo SK (2006) Motion artifact reduction in photoplethysmography using independent component analysis. Biomed Eng IEEE Trans 53(3):566–568 Kim BS, Yoo SK (2006) Motion artifact reduction in photoplethysmography using independent component analysis. Biomed Eng IEEE Trans 53(3):566–568
16.
go back to reference Han H, Kim M-J, Kim J (2007) Development of real-time motion artifact reduction algorithm for a wearable photoplethysmography. In: 2007 29th Annual international conference of the IEEE engineering in medicine and biology society, 2007, pp 1538–1541 Han H, Kim M-J, Kim J (2007) Development of real-time motion artifact reduction algorithm for a wearable photoplethysmography. In: 2007 29th Annual international conference of the IEEE engineering in medicine and biology society, 2007, pp 1538–1541
17.
go back to reference Lee B, Han J, Baek HJ, Shin JH, Park KS, Yi WJ (2010) Improved elimination of motion artifacts from a photoplethysmographic signal using a Kalman smoother with simultaneous accelerometry. Physiol Meas 31(12):1585 Lee B, Han J, Baek HJ, Shin JH, Park KS, Yi WJ (2010) Improved elimination of motion artifacts from a photoplethysmographic signal using a Kalman smoother with simultaneous accelerometry. Physiol Meas 31(12):1585
18.
go back to reference Foo JYA, Wilson SJ, Williams GR, Harris M, Cooper DM (2004) Motion artefact reduction of the photoplethysmographic signal in pulse transit time measurement. Australas Phys Eng Sci Med 27(4):165–173 Foo JYA, Wilson SJ, Williams GR, Harris M, Cooper DM (2004) Motion artefact reduction of the photoplethysmographic signal in pulse transit time measurement. Australas Phys Eng Sci Med 27(4):165–173
19.
go back to reference Couceiro R, Carvalho P, Paiva RP, Henriques J, Muehlsteff J (2012) Detection of motion artifacts in photoplethysmographic signals based on time and period domain analysis. In: 2012 Annual international conference of the IEEE engineering in medicine and biology society, 2012, pp 2603–2606 Couceiro R, Carvalho P, Paiva RP, Henriques J, Muehlsteff J (2012) Detection of motion artifacts in photoplethysmographic signals based on time and period domain analysis. In: 2012 Annual international conference of the IEEE engineering in medicine and biology society, 2012, pp 2603–2606
20.
go back to reference Chong JW et al (2014) Photoplethysmograph signal reconstruction based on a novel hybrid motion artifact detection–reduction approach. Part I: Motion and noise artifact detection. Ann Biomed Eng 42(11):2238–2250 Chong JW et al (2014) Photoplethysmograph signal reconstruction based on a novel hybrid motion artifact detection–reduction approach. Part I: Motion and noise artifact detection. Ann Biomed Eng 42(11):2238–2250
21.
go back to reference Krishnan R, Natarajan B, Warren S (2010) Two-stage approach for detection and reduction of motion artifacts in photoplethysmographic data. IEEE Trans Biomed Eng 57(8):1867–1876 Krishnan R, Natarajan B, Warren S (2010) Two-stage approach for detection and reduction of motion artifacts in photoplethysmographic data. IEEE Trans Biomed Eng 57(8):1867–1876
22.
go back to reference Ram MR, Madhav KV, Krishna EH, Komalla NR, Reddy KA (2012) A novel approach for motion artifact reduction in PPG signals based on AS-LMS adaptive filter. IEEE Trans Instrum Meas 61(5):1445–1457 Ram MR, Madhav KV, Krishna EH, Komalla NR, Reddy KA (2012) A novel approach for motion artifact reduction in PPG signals based on AS-LMS adaptive filter. IEEE Trans Instrum Meas 61(5):1445–1457
23.
go back to reference Basaranoglu G, Bakan M, Umutoglu T, Zengin SU, Idin K, Salihoglu Z (2015) Comparison of SpO2 values from different fingers of the hands. Springerplus 4(1):1–3 Basaranoglu G, Bakan M, Umutoglu T, Zengin SU, Idin K, Salihoglu Z (2015) Comparison of SpO2 values from different fingers of the hands. Springerplus 4(1):1–3
25.
go back to reference Bagha S, Shaw L (2011) A real time analysis of PPG signal for measurement of SpO2 and pulse rate. Int J Comput Appl 36(11):975-8887 Bagha S, Shaw L (2011) A real time analysis of PPG signal for measurement of SpO2 and pulse rate. Int J Comput Appl 36(11):975-8887
26.
go back to reference Smith SW (1997) The scientist and engineer’s guide to digital signal processing, 1st edn. California Technical Publishing, California Smith SW (1997) The scientist and engineer’s guide to digital signal processing, 1st edn. California Technical Publishing, California
27.
go back to reference Hagan MT, Demuth HB, Beale MH (1996) Neural network design, vol 3632. PWS Pub, Boston Hagan MT, Demuth HB, Beale MH (1996) Neural network design, vol 3632. PWS Pub, Boston
28.
go back to reference Mirnezami SV, Hassan-Beygi SR, Banakar A, Ghobadian B (2017) Modelling total weighted vibration of a trailer seat pulled by a two-wheel tractor consumed diesel–biodiesel fuel blends using ANFIS methodology. Neural Comput Appl 28(1):1197–1206 Mirnezami SV, Hassan-Beygi SR, Banakar A, Ghobadian B (2017) Modelling total weighted vibration of a trailer seat pulled by a two-wheel tractor consumed diesel–biodiesel fuel blends using ANFIS methodology. Neural Comput Appl 28(1):1197–1206
29.
go back to reference Sefeedpari P, Rafiee S, Akram A, Chau K, Pishgar-Komleh SH (2016) Prophesying egg production based on energy consumption using multi-layered adaptive neural fuzzy inference system approach. Comput Electron Agric 131:10–19 Sefeedpari P, Rafiee S, Akram A, Chau K, Pishgar-Komleh SH (2016) Prophesying egg production based on energy consumption using multi-layered adaptive neural fuzzy inference system approach. Comput Electron Agric 131:10–19
30.
go back to reference Taormina R, Chau K (2015) Neural network river forecasting with multi-objective fully informed particle swarm optimization. J Hydroinform 17(1):99–113 Taormina R, Chau K (2015) Neural network river forecasting with multi-objective fully informed particle swarm optimization. J Hydroinform 17(1):99–113
31.
go back to reference Gholami V, Chau KW, Fadaee F, Torkaman J, Ghaffari A (2015) Modeling of groundwater level fluctuations using dendrochronology in alluvial aquifers. J Hydrol 529:1060–1069 Gholami V, Chau KW, Fadaee F, Torkaman J, Ghaffari A (2015) Modeling of groundwater level fluctuations using dendrochronology in alluvial aquifers. J Hydrol 529:1060–1069
32.
go back to reference Wang W, Xu D, Chau K, Chen S (2013) Improved annual rainfall-runoff forecasting using PSO–SVM model based on EEMD. J Hydroinform 15(4):1377–1390 Wang W, Xu D, Chau K, Chen S (2013) Improved annual rainfall-runoff forecasting using PSO–SVM model based on EEMD. J Hydroinform 15(4):1377–1390
33.
go back to reference Chau K (2017) Use of meta-heuristic techniques in rainfall-runoff modelling. Multidisciplinary Digital Publishing Institute, Basel Chau K (2017) Use of meta-heuristic techniques in rainfall-runoff modelling. Multidisciplinary Digital Publishing Institute, Basel
34.
go back to reference Zhang S, Chau K-W (2009) Dimension reduction using semi-supervised locally linear embedding for plant leaf classification. In: International conference on intelligent computing, 2009, pp 948–955 Zhang S, Chau K-W (2009) Dimension reduction using semi-supervised locally linear embedding for plant leaf classification. In: International conference on intelligent computing, 2009, pp 948–955
35.
go back to reference Walczak S, Velanovich V (2018) Improving prognosis and reducing decision regret for pancreatic cancer treatment using artificial neural networks. Decis Support Syst 106:110–118 Walczak S, Velanovich V (2018) Improving prognosis and reducing decision regret for pancreatic cancer treatment using artificial neural networks. Decis Support Syst 106:110–118
36.
go back to reference Ghaffari A, Khodayari A, Kamali A, Tajdari F, Hosseinkhani N (2018) New fuzzy solution for determining anticipation and evaluation behavior during car-following maneuvers. Proc Inst Mech Eng Part D J Automob Eng 0954407017724241 Ghaffari A, Khodayari A, Kamali A, Tajdari F, Hosseinkhani N (2018) New fuzzy solution for determining anticipation and evaluation behavior during car-following maneuvers. Proc Inst Mech Eng Part D J Automob Eng 0954407017724241
37.
go back to reference Howard AG et al (2017) Mobilenets: efficient convolutional neural networks for mobile vision applications. arXiv Preprint. arXiv:1704.04861 Howard AG et al (2017) Mobilenets: efficient convolutional neural networks for mobile vision applications. arXiv Preprint. arXiv:​1704.​04861
38.
go back to reference Haykin S, Network N (2004) A comprehensive foundation. Neural Netw 2(2004):41 Haykin S, Network N (2004) A comprehensive foundation. Neural Netw 2(2004):41
39.
go back to reference Broomhead DS, Lowe D (1988) Radial basis functions, multi-variable functional interpolation and adaptive networks (No. RSRE-MEMO-4148). Royal Signals and Radar Establishment Malvern, UK Broomhead DS, Lowe D (1988) Radial basis functions, multi-variable functional interpolation and adaptive networks (No. RSRE-MEMO-4148). Royal Signals and Radar Establishment Malvern, UK
40.
go back to reference Jang J-S (1993) ANFIS: adaptive-network-based fuzzy inference system. IEEE Trans Syst Man Cybern 23(3):665–685 Jang J-S (1993) ANFIS: adaptive-network-based fuzzy inference system. IEEE Trans Syst Man Cybern 23(3):665–685
41.
go back to reference Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1(8476):307–310 Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1(8476):307–310
42.
go back to reference Tarvirdizadeh B, Golgouneh A, Khodabakhshi E, Tajdari F (2017) An assessment of a similarity between the right and left hand Photoplethysmography signals, using time and frequency features of heart-rate-variability signal. In: 2017 IEEE 4th international conference on knowledge-based engineering and innovation (KBEI), pp 0588–0594 Tarvirdizadeh B, Golgouneh A, Khodabakhshi E, Tajdari F (2017) An assessment of a similarity between the right and left hand Photoplethysmography signals, using time and frequency features of heart-rate-variability signal. In: 2017 IEEE 4th international conference on knowledge-based engineering and innovation (KBEI), pp 0588–0594
43.
go back to reference Bonnemeier H et al (2003) Circadian profile of cardiac autonomic nervous modulation in healthy subjects: differing effects of aging and gender on heart rate variability. J Cardiovasc Electrophysiol 14(8):791–799 Bonnemeier H et al (2003) Circadian profile of cardiac autonomic nervous modulation in healthy subjects: differing effects of aging and gender on heart rate variability. J Cardiovasc Electrophysiol 14(8):791–799
44.
go back to reference Fauchier L, Babuty D, Cosnay P, Autret ML, Fauchier JP (1997) Heart rate variability in idiopathic dilated cardiomyopathy: characteristics and prognostic value. J Am Coll Cardiol 30(4):1009–1014 Fauchier L, Babuty D, Cosnay P, Autret ML, Fauchier JP (1997) Heart rate variability in idiopathic dilated cardiomyopathy: characteristics and prognostic value. J Am Coll Cardiol 30(4):1009–1014
45.
go back to reference Kemp AH, Quintana DS, Felmingham KL, Matthews S, Jelinek HF (2012) Depression, comorbid anxiety disorders, and heart rate variability in physically healthy, unmedicated patients: implications for cardiovascular risk. PLoS ONE 7(2):e30777 Kemp AH, Quintana DS, Felmingham KL, Matthews S, Jelinek HF (2012) Depression, comorbid anxiety disorders, and heart rate variability in physically healthy, unmedicated patients: implications for cardiovascular risk. PLoS ONE 7(2):e30777
46.
go back to reference Ponikowski P et al (1997) Depressed heart rate variability as an independent predictor of death in chronic congestive heart failure secondary to ischemic or idiopathic dilated cardiomyopathy. Am J Cardiol 79(12):1645–1650 Ponikowski P et al (1997) Depressed heart rate variability as an independent predictor of death in chronic congestive heart failure secondary to ischemic or idiopathic dilated cardiomyopathy. Am J Cardiol 79(12):1645–1650
47.
go back to reference Counihan PJ, Fei L, Bashir Y, Farrell TG, Haywood GA, McKenna WJ (1993) Assessment of heart rate variability in hypertrophic cardiomyopathy. Association with clinical and prognostic features. Circulation 88(4):1682–1690 Counihan PJ, Fei L, Bashir Y, Farrell TG, Haywood GA, McKenna WJ (1993) Assessment of heart rate variability in hypertrophic cardiomyopathy. Association with clinical and prognostic features. Circulation 88(4):1682–1690
48.
go back to reference Fauchier L, Babuty D, Cosnay P, Fauchier JP (1999) Prognostic value of heart rate variability for sudden death and major arrhythmic events in patients with idiopathic dilated cardiomyopathy. J Am Coll Cardiol 33(5):1203–1207 Fauchier L, Babuty D, Cosnay P, Fauchier JP (1999) Prognostic value of heart rate variability for sudden death and major arrhythmic events in patients with idiopathic dilated cardiomyopathy. J Am Coll Cardiol 33(5):1203–1207
49.
go back to reference Schroeder EB et al (2005) Diabetes, glucose, insulin, and heart rate variability: the Atherosclerosis Risk in Communities (ARIC) study. Diabetes Care 28(3):668–674 Schroeder EB et al (2005) Diabetes, glucose, insulin, and heart rate variability: the Atherosclerosis Risk in Communities (ARIC) study. Diabetes Care 28(3):668–674
50.
go back to reference Galinier M et al (2000) Depressed low frequency power of heart rate variability as an independent predictor of sudden death in chronic heart failure. Eur Heart J 21(6):475–482 Galinier M et al (2000) Depressed low frequency power of heart rate variability as an independent predictor of sudden death in chronic heart failure. Eur Heart J 21(6):475–482
51.
go back to reference Asl BM, Setarehdan SK, Mohebbi M (2008) Support vector machine-based arrhythmia classification using reduced features of heart rate variability signal. Artif Intell Med 44(1):51–64 Asl BM, Setarehdan SK, Mohebbi M (2008) Support vector machine-based arrhythmia classification using reduced features of heart rate variability signal. Artif Intell Med 44(1):51–64
53.
go back to reference Zhai J, Barreto A (2006) Stress detection in computer users based on digital signal processing of noninvasive physiological variables. In: 28th Annual international conference of the IEEE engineering in medicine and biology society, 2006. EMBS’06, pp 1355–1358 Zhai J, Barreto A (2006) Stress detection in computer users based on digital signal processing of noninvasive physiological variables. In: 28th Annual international conference of the IEEE engineering in medicine and biology society, 2006. EMBS’06, pp 1355–1358
54.
go back to reference Chigira H, Kobayashi M, Maeda A (2015) Mouse with photo-plethysmographic surfaces for unobtrusive stress monitoring. in: 2012 IEEE International conference on consumer electronics-Berlin (ICCE-Berlin), pp 304–305 Chigira H, Kobayashi M, Maeda A (2015) Mouse with photo-plethysmographic surfaces for unobtrusive stress monitoring. in: 2012 IEEE International conference on consumer electronics-Berlin (ICCE-Berlin), pp 304–305
55.
go back to reference Zhang H, Zhu Y, Maniyeri J, Guan C (2014) Detection of variations in cognitive workload using multi-modality physiological sensors and a large margin unbiased regression machine. In: 2014 36th Annual international conference of the IEEE engineering in medicine and biology society (EMBC), pp 2985–2988 Zhang H, Zhu Y, Maniyeri J, Guan C (2014) Detection of variations in cognitive workload using multi-modality physiological sensors and a large margin unbiased regression machine. In: 2014 36th Annual international conference of the IEEE engineering in medicine and biology society (EMBC), pp 2985–2988
56.
go back to reference Cinaz B, Arnrich B, La Marca R, Tröster G (2013) Monitoring of mental workload levels during an everyday life office-work scenario. Pers Ubiquitous Comput 17(2):229–239 Cinaz B, Arnrich B, La Marca R, Tröster G (2013) Monitoring of mental workload levels during an everyday life office-work scenario. Pers Ubiquitous Comput 17(2):229–239
57.
go back to reference Kim KH, Bang SW, Kim SR (2004) Emotion recognition system using short-term monitoring of physiological signals. Med Biol Eng Comput 42(3):419–427 Kim KH, Bang SW, Kim SR (2004) Emotion recognition system using short-term monitoring of physiological signals. Med Biol Eng Comput 42(3):419–427
58.
go back to reference Monajati M, Abbasi SH, Shabaninia F, Shamekhi S (2012) Emotions states recognition based on physiological parameters by employing of fuzzy-adaptive resonance theory. Int J Intell Sci 2(4):166 Monajati M, Abbasi SH, Shabaninia F, Shamekhi S (2012) Emotions states recognition based on physiological parameters by employing of fuzzy-adaptive resonance theory. Int J Intell Sci 2(4):166
59.
go back to reference Zheng BS, Murugappan M, Yaacob S (2012) Human emotional stress assessment through heart rate detection in a customized protocol experiment. In: 2012 IEEE symposium on industrial electronics and applications (ISIEA), 2012, pp 293–298 Zheng BS, Murugappan M, Yaacob S (2012) Human emotional stress assessment through heart rate detection in a customized protocol experiment. In: 2012 IEEE symposium on industrial electronics and applications (ISIEA), 2012, pp 293–298
Metadata
Title
A novel online method for identifying motion artifact and photoplethysmography signal reconstruction using artificial neural networks and adaptive neuro-fuzzy inference system
Authors
Bahram Tarvirdizadeh
Alireza Golgouneh
Farzam Tajdari
Erfan Khodabakhshi
Publication date
06-10-2018
Publisher
Springer London
Published in
Neural Computing and Applications / Issue 8/2020
Print ISSN: 0941-0643
Electronic ISSN: 1433-3058
DOI
https://doi.org/10.1007/s00521-018-3767-8

Other articles of this Issue 8/2020

Neural Computing and Applications 8/2020 Go to the issue

Premium Partner