Skip to main content
Top
Published in: International Journal of Computer Vision 2/2017

21-06-2016

Automatic Sleep System Recommendation by Multi-modal RBG-Depth-Pressure Anthropometric Analysis

Authors: Cristina Palmero, Jordi Esquirol, Vanessa Bayo, Miquel Àngel Cos, Pouya Ahmadmonfared, Joan Salabert, David Sánchez, Sergio Escalera

Published in: International Journal of Computer Vision | Issue 2/2017

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

This paper presents a novel system for automatic sleep system recommendation using RGB, depth and pressure information. It consists of a validated clinical knowledge-based model that, along with a set of prescription variables extracted automatically, obtains a personalized bed design recommendation. The automatic process starts by performing multi-part human body RGB-D segmentation combining GrabCut, 3D Shape Context descriptor and Thin Plate Splines, to then extract a set of anthropometric landmark points by applying orthogonal plates to the segmented human body. The extracted variables are introduced to the computerized clinical model to calculate body circumferences, weight, morphotype and Body Mass Index categorization. Furthermore, pressure image analysis is performed to extract pressure values and at-risk points, which are also introduced to the model to eventually obtain the final prescription of mattress, topper, and pillow. We validate the complete system in a set of 200 subjects, showing accurate category classification and high correlation results with respect to manual measures.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
go back to reference Allen, B., Curless, B., & Popović, Z. (2004). Exploring the space of human body shapes: Data-driven synthesis under anthropometric control. Tech. rep., SAE Technical Paper Allen, B., Curless, B., & Popović, Z. (2004). Exploring the space of human body shapes: Data-driven synthesis under anthropometric control. Tech. rep., SAE Technical Paper
go back to reference Azouz, Z. B., Shu, C., & Mantel, A. (2006). Automatic locating of anthropometric landmarks on 3d human models. In: Third International Symposium on 3D Data Processing, Visualization, and Transmission, pp. 750–757. IEEE. Azouz, Z. B., Shu, C., & Mantel, A. (2006). Automatic locating of anthropometric landmarks on 3d human models. In: Third International Symposium on 3D Data Processing, Visualization, and Transmission, pp. 750–757. IEEE.
go back to reference Bain, D., Ferguson-Pell, M., & McLeod, A. (2003). Evaluation of mattresses using interface pressure mapping. Journal of Wound Care, 12(6), 231–235.CrossRef Bain, D., Ferguson-Pell, M., & McLeod, A. (2003). Evaluation of mattresses using interface pressure mapping. Journal of Wound Care, 12(6), 231–235.CrossRef
go back to reference Belongie, S., Malik, J., & Puzicha, J. (2002). Shape matching and object recognition using shape contexts. IEEE Transactions on Pattern Analysis and Machine Intelligence, 24(4), 509–522.CrossRef Belongie, S., Malik, J., & Puzicha, J. (2002). Shape matching and object recognition using shape contexts. IEEE Transactions on Pattern Analysis and Machine Intelligence, 24(4), 509–522.CrossRef
go back to reference Benjumea, A. C. (2001). Datos antropométricos de la población laboral española. Prevención, trabajo y salud: Revista del Instituto Nacional de Seguridad e Higiene en el Trabajo, 14, 22–30. Benjumea, A. C. (2001). Datos antropométricos de la población laboral española. Prevención, trabajo y salud: Revista del Instituto Nacional de Seguridad e Higiene en el Trabajo, 14, 22–30.
go back to reference Bookstein, F. L. (1989). Principal warps: Thin-plate splines and the decomposition of deformations. IEEE Transactions on Pattern Analysis & Machine Intelligence, 6, 567–585.CrossRefMATH Bookstein, F. L. (1989). Principal warps: Thin-plate splines and the decomposition of deformations. IEEE Transactions on Pattern Analysis & Machine Intelligence, 6, 567–585.CrossRefMATH
go back to reference Boykov, Y., & Funka-Lea, G. (2006). Graph cuts and efficient n-d image segmentation. International Journal of Computer Vision, 70(2), 109–131.CrossRef Boykov, Y., & Funka-Lea, G. (2006). Graph cuts and efficient n-d image segmentation. International Journal of Computer Vision, 70(2), 109–131.CrossRef
go back to reference Canda, A. S., & de Deportes, C. S. (2012). Variables antropométricas de la población deportista española. Consejo Superior de Deportes, Servicio de Documentación y Publicaciones. Canda, A. S., & de Deportes, C. S. (2012). Variables antropométricas de la población deportista española. Consejo Superior de Deportes, Servicio de Documentación y Publicaciones.
go back to reference Cippitelli, E., Gasparrini, S., Spinsante, S., & Gambi, E. (2015). Kinect as a tool for gait analysis: Validation of a real-time joint extraction algorithm working in side view. Sensors, 15(1), 1417–1434.CrossRef Cippitelli, E., Gasparrini, S., Spinsante, S., & Gambi, E. (2015). Kinect as a tool for gait analysis: Validation of a real-time joint extraction algorithm working in side view. Sensors, 15(1), 1417–1434.CrossRef
go back to reference Clarkson, S., Wheat, J., Heller, B., & Choppin, S. (2014). Assessing the suitability of the microsoft kinect for calculating person specific body segment parameters. In Computer Vision-ECCV 2014 Workshops, pp. 372–385. Springer. Clarkson, S., Wheat, J., Heller, B., & Choppin, S. (2014). Assessing the suitability of the microsoft kinect for calculating person specific body segment parameters. In Computer Vision-ECCV 2014 Workshops, pp. 372–385. Springer.
go back to reference de Sanidad y Consumo, M. (2008). Estudio antropométrico de la población femenina española. de Sanidad y Consumo, M. (2008). Estudio antropométrico de la población femenina española.
go back to reference Dempster, A. P., Laird, N. M., & Rubin, D. B. (1977). Maximum likelihood from incomplete data via the em algorithm. Journal of the Royal Statistical Society Series B (Methodological), 39, 1–38.MathSciNetMATH Dempster, A. P., Laird, N. M., & Rubin, D. B. (1977). Maximum likelihood from incomplete data via the em algorithm. Journal of the Royal Statistical Society Series B (Methodological), 39, 1–38.MathSciNetMATH
go back to reference Determann, R. M., Wolthuis, E. K., Spronk, P. E., Kuiper, M. A., Korevaar, J. C., Vroom, M. B., et al. (2007). Reliability of height and weight estimates in patients acutely admitted to intensive care units. Critical Care Nurse, 27(5), 48–55. Determann, R. M., Wolthuis, E. K., Spronk, P. E., Kuiper, M. A., Korevaar, J. C., Vroom, M. B., et al. (2007). Reliability of height and weight estimates in patients acutely admitted to intensive care units. Critical Care Nurse, 27(5), 48–55.
go back to reference DeVocht, J. W., Wilder, D. G., Bandstra, E. R., & Spratt, K. F. (2006). Biomechanical evaluation of four different mattresses. Applied Ergonomics, 37(3), 297–304.CrossRef DeVocht, J. W., Wilder, D. G., Bandstra, E. R., & Spratt, K. F. (2006). Biomechanical evaluation of four different mattresses. Applied Ergonomics, 37(3), 297–304.CrossRef
go back to reference Espitia-Contreras, A., Sanchez-Caiman, P., & Uribe-Quevedo, A. (2014). Development of a kinect-based anthropometric measurement application. In 2014 IEEE Virtual Reality (VR), pp. 71–72. IEEE. Espitia-Contreras, A., Sanchez-Caiman, P., & Uribe-Quevedo, A. (2014). Development of a kinect-based anthropometric measurement application. In 2014 IEEE Virtual Reality (VR), pp. 71–72. IEEE.
go back to reference Fischler, M. A., & Bolles, R. C. (1981). Random sample consensus: A paradigm for model fitting with applications to image analysis and automated cartography. Communications of the ACM, 24(6), 381–395.MathSciNetCrossRef Fischler, M. A., & Bolles, R. C. (1981). Random sample consensus: A paradigm for model fitting with applications to image analysis and automated cartography. Communications of the ACM, 24(6), 381–395.MathSciNetCrossRef
go back to reference Foubert, N. (2010). Posture recognition and postural transition detection using bed-based pressure sensor. PhD thesis, Carleton University Ottawa. Foubert, N. (2010). Posture recognition and postural transition detection using bed-based pressure sensor. PhD thesis, Carleton University Ottawa.
go back to reference Gordon, S. J., & Grimmer-Somers, K. (2011). Your pillow may not guarantee a good night’s sleep or symptom-free waking. Physiotherapy Canada, 63(2), 183–190.CrossRef Gordon, S. J., & Grimmer-Somers, K. (2011). Your pillow may not guarantee a good night’s sleep or symptom-free waking. Physiotherapy Canada, 63(2), 183–190.CrossRef
go back to reference Gordon, S. J., Grimmer-Somers, K., & Trott, P. (2009). Pillow use: The behaviour of cervical pain, sleep quality and pillow comfort in side sleepers. Manual Therapy, 14(6), 671–678.CrossRef Gordon, S. J., Grimmer-Somers, K., & Trott, P. (2009). Pillow use: The behaviour of cervical pain, sleep quality and pillow comfort in side sleepers. Manual Therapy, 14(6), 671–678.CrossRef
go back to reference Gordon, S. J., Grimmer-Somers, K. A., & Trott, P. H. (2010). Pillow use: The behavior of cervical stiffness, headache and scapular/arm pain. Journal of Pain Research, 3, 137. Gordon, S. J., Grimmer-Somers, K. A., & Trott, P. H. (2010). Pillow use: The behavior of cervical stiffness, headache and scapular/arm pain. Journal of Pain Research, 3, 137.
go back to reference Gupta, S., Markey, M. K., & Bovik, A. C. (2010). Anthropometric 3d face recognition. International Journal of Computer Vision, 90(3), 331–349.CrossRef Gupta, S., Markey, M. K., & Bovik, A. C. (2010). Anthropometric 3d face recognition. International Journal of Computer Vision, 90(3), 331–349.CrossRef
go back to reference Harada, T., Mori, T., Nishida, Y., Yoshimi, T., & Sato, T. (1999). Body parts positions and posture estimation system based on pressure distribution image. In Proceedings of the 1999 IEEE international conference on robotics and automation (Vol. 2, pp. 968–975). IEEE. Harada, T., Mori, T., Nishida, Y., Yoshimi, T., & Sato, T. (1999). Body parts positions and posture estimation system based on pressure distribution image. In Proceedings of the 1999 IEEE international conference on robotics and automation (Vol. 2, pp. 968–975). IEEE.
go back to reference Harada, T., Sato, T., & Mori, T. (2001). Pressure distribution image based human motion tracking system using skeleton and surface integration model. In Proceedings 2001 ICRA IEEE international conference on robotics and automation (Vol. 4, pp. 3201–3207). IEEE. Harada, T., Sato, T., & Mori, T. (2001). Pressure distribution image based human motion tracking system using skeleton and surface integration model. In Proceedings 2001 ICRA IEEE international conference on robotics and automation (Vol. 4, pp. 3201–3207). IEEE.
go back to reference Huang, S. H., & Pan, Y. C. (2014). Ergonomic job rotation strategy based on an automated rgb-d anthropometric measuring system. Journal of Manufacturing Systems, 33(4), 699–710.CrossRef Huang, S. H., & Pan, Y. C. (2014). Ergonomic job rotation strategy based on an automated rgb-d anthropometric measuring system. Journal of Manufacturing Systems, 33(4), 699–710.CrossRef
go back to reference Huang, W., Wai, A.A.P., Foo, S.F., Biswas, J., Hsia, C.C., & Liou, K. (2010). Multimodal sleeping posture classification. In 2010 20th international conference on pattern recognition (ICPR), pp. 4336–4339. IEEE. Huang, W., Wai, A.A.P., Foo, S.F., Biswas, J., Hsia, C.C., & Liou, K. (2010). Multimodal sleeping posture classification. In 2010 20th international conference on pattern recognition (ICPR), pp. 4336–4339. IEEE.
go back to reference Joint, F., Organization, W. H., et al. (1985). Energy and protein requirements: report of a joint fa. Joint, F., Organization, W. H., et al. (1985). Energy and protein requirements: report of a joint fa.
go back to reference Jonker, R., & Volgenant, A. (1987). A shortest augmenting path algorithm for dense and sparse linear assignment problems. Computing, 38(4), 325–340.MathSciNetCrossRefMATH Jonker, R., & Volgenant, A. (1987). A shortest augmenting path algorithm for dense and sparse linear assignment problems. Computing, 38(4), 325–340.MathSciNetCrossRefMATH
go back to reference Kim, H. S., Park, K. H., & Jeoung, J. W. (2013). Can we measure the intraocular pressure when the eyeball is against the pillow in the lateral decubitus position? Acta Ophthalmologica, 91(7), e502–e505.CrossRef Kim, H. S., Park, K. H., & Jeoung, J. W. (2013). Can we measure the intraocular pressure when the eyeball is against the pillow in the lateral decubitus position? Acta Ophthalmologica, 91(7), e502–e505.CrossRef
go back to reference Lazzaro, E., Mallick, A., Singh, M., Reich, I., Elmann, S., Stefanov, D. G., et al. (2014). The effect of positional changes on intraocular pressure during sleep in patients with and without glaucoma. Journal of Glaucoma, 23(5), 282–287.CrossRef Lazzaro, E., Mallick, A., Singh, M., Reich, I., Elmann, S., Stefanov, D. G., et al. (2014). The effect of positional changes on intraocular pressure during sleep in patients with and without glaucoma. Journal of Glaucoma, 23(5), 282–287.CrossRef
go back to reference Leilnahari, K., Fatouraee, N., Khodalotfi, M., Sadeghein, M. A., & Kashani, Y. A. (2011). Spine alignment in men during lateral sleep position: experimental study and modeling. Biomedical Engineering Online, 10(1), 103.CrossRef Leilnahari, K., Fatouraee, N., Khodalotfi, M., Sadeghein, M. A., & Kashani, Y. A. (2011). Spine alignment in men during lateral sleep position: experimental study and modeling. Biomedical Engineering Online, 10(1), 103.CrossRef
go back to reference Liu, J.J., Xu, W., Huang, M.C., Alshurafa, N., Sarrafzadeh, M., Raut, N., & Yadegar, B. (2013). A dense pressure sensitive bedsheet design for unobtrusive sleep posture monitoring. In 2013 IEEE international conference on pervasive computing and communications (PerCom), pp 207–215. IEEE. Liu, J.J., Xu, W., Huang, M.C., Alshurafa, N., Sarrafzadeh, M., Raut, N., & Yadegar, B. (2013). A dense pressure sensitive bedsheet design for unobtrusive sleep posture monitoring. In 2013 IEEE international conference on pervasive computing and communications (PerCom), pp 207–215. IEEE.
go back to reference Liu, J. J., Xu, W., Huang, M. C., Alshurafa, N., Sarrafzadeh, M., Raut, N., et al. (2014). Sleep posture analysis using a dense pressure sensitive bedsheet. Pervasive and Mobile Computing, 10, 34–50.CrossRef Liu, J. J., Xu, W., Huang, M. C., Alshurafa, N., Sarrafzadeh, M., Raut, N., et al. (2014). Sleep posture analysis using a dense pressure sensitive bedsheet. Pervasive and Mobile Computing, 10, 34–50.CrossRef
go back to reference López-Torres, M., Porcar, R., Solaz, J., & Romero, T. (2008). Objective firmness, average pressure and subjective perception in mattresses for the elderly. Applied Ergonomics, 39(1), 123–130.CrossRef López-Torres, M., Porcar, R., Solaz, J., & Romero, T. (2008). Objective firmness, average pressure and subjective perception in mattresses for the elderly. Applied Ergonomics, 39(1), 123–130.CrossRef
go back to reference Lorenz, M. W., Graf, M., Henke, C., Hermans, M., Ziemann, U., Sitzer, M., et al. (2007). Anthropometric approximation of body weight in unresponsive stroke patients. Journal of Neurology, Neurosurgery & Psychiatry, 78(12), 1331–1336.CrossRef Lorenz, M. W., Graf, M., Henke, C., Hermans, M., Ziemann, U., Sitzer, M., et al. (2007). Anthropometric approximation of body weight in unresponsive stroke patients. Journal of Neurology, Neurosurgery & Psychiatry, 78(12), 1331–1336.CrossRef
go back to reference Lorenzo-Navarro, J., Castrillón-Santana, M., & Hernández-Sosa, D. (2013). On the use of simple geometric descriptors provided by rgb-d sensors for re-identification. Sensors, 13(7), 8222–8238.CrossRef Lorenzo-Navarro, J., Castrillón-Santana, M., & Hernández-Sosa, D. (2013). On the use of simple geometric descriptors provided by rgb-d sensors for re-identification. Sensors, 13(7), 8222–8238.CrossRef
go back to reference Madadi, M., Escalera, S., Gonzalez, J., Roca, F. X., & Lumbreras, F. (2015). Multi-part body segmentation based on depth maps for soft biometry analysis. Pattern Recognition Letters, 56, 14–21.CrossRef Madadi, M., Escalera, S., Gonzalez, J., Roca, F. X., & Lumbreras, F. (2015). Multi-part body segmentation based on depth maps for soft biometry analysis. Pattern Recognition Letters, 56, 14–21.CrossRef
go back to reference Martinez, M., & Stiefelhagen, R. (2014). Kinect unbiased. In 2014 IEEE International Conference on Image Processing (ICIP), pp. 5791–5795. IEEE. Martinez, M., & Stiefelhagen, R. (2014). Kinect unbiased. In 2014 IEEE International Conference on Image Processing (ICIP), pp. 5791–5795. IEEE.
go back to reference Matsuo, J., Sugama, J., Sanada, H., Okuwa, M., Nakatani, T., Konya, C., et al. (2011). Development and validity of a new model for assessing pressure redistribution properties of support surfaces. Journal of Tissue Viability, 20(2), 55–66.CrossRef Matsuo, J., Sugama, J., Sanada, H., Okuwa, M., Nakatani, T., Konya, C., et al. (2011). Development and validity of a new model for assessing pressure redistribution properties of support surfaces. Journal of Tissue Viability, 20(2), 55–66.CrossRef
go back to reference Metsis, V., Kosmopoulos, D., Athitsos, V., & Makedon, F. (2014). Non-invasive analysis of sleep patterns via multimodal sensor input. Personal and Ubiquitous Computing, 18(1), 19–26.CrossRef Metsis, V., Kosmopoulos, D., Athitsos, V., & Makedon, F. (2014). Non-invasive analysis of sleep patterns via multimodal sensor input. Personal and Ubiquitous Computing, 18(1), 19–26.CrossRef
go back to reference Miller, S., Parker, M., Blasiole, N., Beinlich, N., & Fulton, J. (2013). A prospective, in vivo evaluation of two pressure-redistribution surfaces in healthy volunteers using pressure mapping as a quality control instrument. Ostomy/Wound Management, 59(2), 44–48. Miller, S., Parker, M., Blasiole, N., Beinlich, N., & Fulton, J. (2013). A prospective, in vivo evaluation of two pressure-redistribution surfaces in healthy volunteers using pressure mapping as a quality control instrument. Ostomy/Wound Management, 59(2), 44–48.
go back to reference Mogelmose, A., Bahnsen, C., Moeslund, T.B., Clapés, A., & Escalera, S. (2013). Tri-modal person re-identification with rgb, depth and thermal features. In 2013 IEEE conference on computer vision and pattern recognition workshops (CVPRW), pp 301–307. IEEE. Mogelmose, A., Bahnsen, C., Moeslund, T.B., Clapés, A., & Escalera, S. (2013). Tri-modal person re-identification with rgb, depth and thermal features. In 2013 IEEE conference on computer vision and pattern recognition workshops (CVPRW), pp 301–307. IEEE.
go back to reference Nechala, P., Mahoney, J., & Farkas, L. G. (1999). Digital two-dimensional photogrammetry: A comparison of three techniques of obtaining digital photographs. Plastic and Reconstructive Surgery, 103(7), 1819–1825.CrossRef Nechala, P., Mahoney, J., & Farkas, L. G. (1999). Digital two-dimensional photogrammetry: A comparison of three techniques of obtaining digital photographs. Plastic and Reconstructive Surgery, 103(7), 1819–1825.CrossRef
go back to reference Nguyen, T. V., Feng, J., & Yan, S. (2014). Seeing human weight from a single rgb-d image. Journal of Computer Science and Technology, 29(5), 777–784.CrossRef Nguyen, T. V., Feng, J., & Yan, S. (2014). Seeing human weight from a single rgb-d image. Journal of Computer Science and Technology, 29(5), 777–784.CrossRef
go back to reference Reyes, M., Clapés, A., Ramírez, J., Revilla, J. R., & Escalera, S. (2013). Automatic digital biometry analysis based on depth maps. Computers in Industry, 64(9), 1316–1325.CrossRef Reyes, M., Clapés, A., Ramírez, J., Revilla, J. R., & Escalera, S. (2013). Automatic digital biometry analysis based on depth maps. Computers in Industry, 64(9), 1316–1325.CrossRef
go back to reference Romero Collazos, J. (2008). Análisis de la forma y la proporcionalidad. antropometria aplicada a la nutrición. Romero Collazos, J. (2008). Análisis de la forma y la proporcionalidad. antropometria aplicada a la nutrición.
go back to reference Rother, C., Kolmogorov, V., & Blake, A. (2004). Grabcut: Interactive foreground extraction using iterated graph cuts. ACM Transactions on Graphics (TOG), 23(3), 309–314.CrossRef Rother, C., Kolmogorov, V., & Blake, A. (2004). Grabcut: Interactive foreground extraction using iterated graph cuts. ACM Transactions on Graphics (TOG), 23(3), 309–314.CrossRef
go back to reference Rusu, R. B. (2013). Semantic 3D object maps for everyday robot manipulation (Vol. 85). Heidelberg: Springer. Rusu, R. B. (2013). Semantic 3D object maps for everyday robot manipulation (Vol. 85). Heidelberg: Springer.
go back to reference Sáenz, Z. L., Arias, A., Guzmán, E. C., & Arias, d L. (2011). Analysis of ergonomics conditions of a brand of mattress and pillows. University-industry project, medellin-colombia. Work (Reading, Mass), 41, 1281–1287. Sáenz, Z. L., Arias, A., Guzmán, E. C., & Arias, d L. (2011). Analysis of ergonomics conditions of a brand of mattress and pillows. University-industry project, medellin-colombia. Work (Reading, Mass), 41, 1281–1287.
go back to reference Suzuki, K., Horiba, I., & Sugie, N. (2003). Linear-time connected-component labeling based on sequential local operations. Computer Vision and Image Understanding, 89(1), 1–23. Suzuki, K., Horiba, I., & Sugie, N. (2003). Linear-time connected-component labeling based on sequential local operations. Computer Vision and Image Understanding, 89(1), 1–23.
go back to reference Uhm, T., Park, H., & Park, J. I. (2015). Fully vision-based automatic human body measurement system for apparel application. Measurement, 61, 169–179.CrossRef Uhm, T., Park, H., & Park, J. I. (2015). Fully vision-based automatic human body measurement system for apparel application. Measurement, 61, 169–179.CrossRef
go back to reference Verhaert, V., Druyts, H., Van Deun, D., Berckmans, D., Verbraecken, J., Vandekerckhove, M., Haex, B., & Vander Sloten, J. (2011a). The use of a generic human model to personalize bed design. In: Proceedings of 1st international symposium on digital human modeling, vol 2202. Lyon, June, paper ID. Verhaert, V., Druyts, H., Van Deun, D., Berckmans, D., Verbraecken, J., Vandekerckhove, M., Haex, B., & Vander Sloten, J. (2011a). The use of a generic human model to personalize bed design. In: Proceedings of 1st international symposium on digital human modeling, vol 2202. Lyon, June, paper ID.
go back to reference Verhaert, V., Druyts, H., Van Deun, D., De Wilde, T., Van Brussel, K., Haex, B., et al. (2011b). Modeling human-bed interaction: The predictive value of anthropometric models in choosing the correct bed support. Work (Reading, Mass), 41, 2268–2273. Verhaert, V., Druyts, H., Van Deun, D., De Wilde, T., Van Brussel, K., Haex, B., et al. (2011b). Modeling human-bed interaction: The predictive value of anthropometric models in choosing the correct bed support. Work (Reading, Mass), 41, 2268–2273.
go back to reference Verhaert, V., Haex, B., Wilde, T. D., Berckmans, D., Verbraecken, J., Valck, Ed, et al. (2011c). Ergonomics in bed design: the effect of spinal alignment on sleep parameters. Ergonomics, 54(2), 169–178. Verhaert, V., Haex, B., Wilde, T. D., Berckmans, D., Verbraecken, J., Valck, Ed, et al. (2011c). Ergonomics in bed design: the effect of spinal alignment on sleep parameters. Ergonomics, 54(2), 169–178.
go back to reference Wang, Q., Jagadeesh, V., Ressler, B., & Piramuthu, R. (2014). Im2fit: Fast 3d model fitting and anthropometrics using single consumer depth camera and synthetic data. arXiv:1410.0745. Wang, Q., Jagadeesh, V., Ressler, B., & Piramuthu, R. (2014). Im2fit: Fast 3d model fitting and anthropometrics using single consumer depth camera and synthetic data. arXiv:​1410.​0745.
go back to reference Wong, M., Lai, A., Singh, M., & Chew, P. (2013). Sleeping posture and intraocular pressure. Singapore Medical Journal, 54(3), 146–148.CrossRef Wong, M., Lai, A., Singh, M., & Chew, P. (2013). Sleeping posture and intraocular pressure. Singapore Medical Journal, 54(3), 146–148.CrossRef
go back to reference Yang, C., Mao, Y., Cheung, G., Stankovic, V., & Chan, K. L. (2014). Graph-based depth video denoising and event detection for sleep monitoring. In 2014 IEEE 16th international workshop on multimedia signal processing (MMSP), IEEE, pp 1–6. Yang, C., Mao, Y., Cheung, G., Stankovic, V., & Chan, K. L. (2014). Graph-based depth video denoising and event detection for sleep monitoring. In 2014 IEEE 16th international workshop on multimedia signal processing (MMSP), IEEE, pp 1–6.
go back to reference Yousefi, R., Ostadabbas, S., Faezipour, M., Nourani, M., Tamil, L., & Pompeo, M. (2011). Posture and limb detection for pressure ulcer prevention. In Proceedings of the Southern Biomedical Engineering Conference (SBEC). Yousefi, R., Ostadabbas, S., Faezipour, M., Nourani, M., Tamil, L., & Pompeo, M. (2011). Posture and limb detection for pressure ulcer prevention. In Proceedings of the Southern Biomedical Engineering Conference (SBEC).
go back to reference Yu, M. C., Wu, H., Liou, J. L., Lee, M. S., & Hung, Y. P. (2012). Breath and position monitoring during sleeping with a depth camera. In HEALTHINF, pp 12–22. Yu, M. C., Wu, H., Liou, J. L., Lee, M. S., & Hung, Y. P. (2012). Breath and position monitoring during sleeping with a depth camera. In HEALTHINF, pp 12–22.
go back to reference Zuberi, N. A., Rekab, K., & Nguyen, H. V. (2004). Sleep apnea avoidance pillow effects on obstructive sleep apnea syndrome and snoring. Sleep and Breathing, 8(4), 201–207.CrossRef Zuberi, N. A., Rekab, K., & Nguyen, H. V. (2004). Sleep apnea avoidance pillow effects on obstructive sleep apnea syndrome and snoring. Sleep and Breathing, 8(4), 201–207.CrossRef
Metadata
Title
Automatic Sleep System Recommendation by Multi-modal RBG-Depth-Pressure Anthropometric Analysis
Authors
Cristina Palmero
Jordi Esquirol
Vanessa Bayo
Miquel Àngel Cos
Pouya Ahmadmonfared
Joan Salabert
David Sánchez
Sergio Escalera
Publication date
21-06-2016
Publisher
Springer US
Published in
International Journal of Computer Vision / Issue 2/2017
Print ISSN: 0920-5691
Electronic ISSN: 1573-1405
DOI
https://doi.org/10.1007/s11263-016-0919-0

Other articles of this Issue 2/2017

International Journal of Computer Vision 2/2017 Go to the issue

Premium Partner