Skip to main content
Top

2018 | OriginalPaper | Chapter

(Bio-)chemical Sensing and Imaging by LAPS and SPIM

Authors : Tatsuo Yoshinobu, Steffi Krause, Ko-ichiro Miyamoto, Carl Frederik Werner, Arshak Poghossian, Torsten Wagner, Michael J. Schöning

Published in: Label-Free Biosensing

Publisher: Springer International Publishing

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

The light-addressable potentiometric sensor (LAPS) and scanning photo-induced impedance microscopy (SPIM) are two closely related methods to visualise the distributions of chemical species and impedance, respectively, at the interface between the sensing surface and the sample solution. They both have the same field-effect structure based on a semiconductor, which allows spatially resolved and label-free measurement of chemical species and impedance in the form of a photocurrent signal generated by a scanning light beam. In this article, the principles and various operation modes of LAPS and SPIM, functionalisation of the sensing surface for measuring various species, LAPS-based chemical imaging and high-resolution sensors based on silicon-on-sapphire substrates are described and discussed, focusing on their technical details and prospective applications.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Bergveld P (1970) Development of an ion-sensitive solid-state device for neurophysiological measurements. IEEE Trans Biomed Eng 17:70–71CrossRefPubMed Bergveld P (1970) Development of an ion-sensitive solid-state device for neurophysiological measurements. IEEE Trans Biomed Eng 17:70–71CrossRefPubMed
2.
go back to reference Hafeman DG, Parce JW, McConnell HM (1988) Light-addressable potentiometric sensor for biochemical systems. Science 240:1182–1185PubMedCrossRef Hafeman DG, Parce JW, McConnell HM (1988) Light-addressable potentiometric sensor for biochemical systems. Science 240:1182–1185PubMedCrossRef
3.
go back to reference Krause S, Talabani H, Xu M, Moritz W, Griffiths J (2002) Scanning photo-induced impedance microscopy – an impedance based imaging technique. Electrochim Acta 47:2143–2148CrossRef Krause S, Talabani H, Xu M, Moritz W, Griffiths J (2002) Scanning photo-induced impedance microscopy – an impedance based imaging technique. Electrochim Acta 47:2143–2148CrossRef
4.
go back to reference Yoshinobu T, Ecken H, Poghossian A, Lüth H, Iwasaki H, Schöning MJ (2001) Alternative sensor materials for light-addressable potentiometric sensors. Sensors Actuators B Chem 76:388–392CrossRef Yoshinobu T, Ecken H, Poghossian A, Lüth H, Iwasaki H, Schöning MJ (2001) Alternative sensor materials for light-addressable potentiometric sensors. Sensors Actuators B Chem 76:388–392CrossRef
5.
go back to reference Adami M, Alliata D, Del Carlo C, Martini M, Piras L, Sartore M, Nicolini C (1995) Characterization of silicon transducers with Si3N4 sensing surfaces by an AFM and a PAB system. Sensors Actuators B Chem 24–25:889–893CrossRef Adami M, Alliata D, Del Carlo C, Martini M, Piras L, Sartore M, Nicolini C (1995) Characterization of silicon transducers with Si3N4 sensing surfaces by an AFM and a PAB system. Sensors Actuators B Chem 24–25:889–893CrossRef
6.
go back to reference Ismail ABM, Harada T, Yoshinobu T, Iwasaki H, Schöning MJ, Lüth H (2000) Investigation of pulsed laser-deposited Al2O3 as a high pH-sensitive layer for LAPS-based biosensing applications. Sensors Actuators B Chem 71:169–172CrossRef Ismail ABM, Harada T, Yoshinobu T, Iwasaki H, Schöning MJ, Lüth H (2000) Investigation of pulsed laser-deposited Al2O3 as a high pH-sensitive layer for LAPS-based biosensing applications. Sensors Actuators B Chem 71:169–172CrossRef
7.
go back to reference Werner CF, Wagner T, Yoshinobu T, Keusgen M, Schöning MJ (2013) Frequency behaviour of light-addressable potentiometric sensors. Phys Status Solidi A 210:884–891CrossRef Werner CF, Wagner T, Yoshinobu T, Keusgen M, Schöning MJ (2013) Frequency behaviour of light-addressable potentiometric sensors. Phys Status Solidi A 210:884–891CrossRef
8.
go back to reference Nakao M, Yoshinobu T, Iwasaki H (1994) Scanning-laser-beam semiconductor pH-imaging sensor. Sensors Actuators B Chem 20:119–123CrossRef Nakao M, Yoshinobu T, Iwasaki H (1994) Scanning-laser-beam semiconductor pH-imaging sensor. Sensors Actuators B Chem 20:119–123CrossRef
9.
go back to reference Wagner T, Werner CF, Miyamoto K, Schöning MJ, Yoshinobu T (2011) A high-density multi-point LAPS set-up using a VCSEL array and FPGA control. Sensors Actuators B Chem 154:124–128CrossRef Wagner T, Werner CF, Miyamoto K, Schöning MJ, Yoshinobu T (2011) A high-density multi-point LAPS set-up using a VCSEL array and FPGA control. Sensors Actuators B Chem 154:124–128CrossRef
10.
go back to reference Chen L, Zhou Y, Jiang S, Kunze J, Schmuki P, Krause S (2010) High resolution LAPS and SPIM. Electrochem Commun 12:758–760CrossRef Chen L, Zhou Y, Jiang S, Kunze J, Schmuki P, Krause S (2010) High resolution LAPS and SPIM. Electrochem Commun 12:758–760CrossRef
11.
go back to reference Adami M, Sartore M, Nicolini C (1995) PAB: a newly designed potentiometric alternating biosensor system. Biosens Bioelectron 10:155–167CrossRef Adami M, Sartore M, Nicolini C (1995) PAB: a newly designed potentiometric alternating biosensor system. Biosens Bioelectron 10:155–167CrossRef
12.
go back to reference Miyamoto K, Kaneko K, Matsuo A, Wagner T, Kanoh S, Schöning MJ, Yoshinobu T (2012) Miniaturized chemical imaging sensor system using an OLED display panel. Sensors Actuators B Chem 170:82–87CrossRef Miyamoto K, Kaneko K, Matsuo A, Wagner T, Kanoh S, Schöning MJ, Yoshinobu T (2012) Miniaturized chemical imaging sensor system using an OLED display panel. Sensors Actuators B Chem 170:82–87CrossRef
13.
go back to reference Werner CF, Wagner T, Miyamoto K, Yoshinobu T, Schöning MJ (2012) High speed and high resolution chemical imaging based on a new type of OLED-LAPS set-up. Sensors Actuators B Chem 175:118–122CrossRef Werner CF, Wagner T, Miyamoto K, Yoshinobu T, Schöning MJ (2012) High speed and high resolution chemical imaging based on a new type of OLED-LAPS set-up. Sensors Actuators B Chem 175:118–122CrossRef
14.
go back to reference Wagner T, Miyamoto K, Werner CF, Schöning MJ, Yoshinobu T (2011) Utilising digital micro-mirror device (DMD) as scanning light source for light-addressable potentiometric sensors (LAPS). Sens Lett 9:812–815CrossRef Wagner T, Miyamoto K, Werner CF, Schöning MJ, Yoshinobu T (2011) Utilising digital micro-mirror device (DMD) as scanning light source for light-addressable potentiometric sensors (LAPS). Sens Lett 9:812–815CrossRef
15.
go back to reference Poghossian A, Werner CF, Buniatyan VV, Wagner T, Miamoto K, Yoshinobu T, Schöning MJ (2017) Towards addressability of light-addressable potentiometric sensors: shunting effect of non-illuminated region and cross-talk. Sensors Actuators B Chem 244:1071–1079CrossRef Poghossian A, Werner CF, Buniatyan VV, Wagner T, Miamoto K, Yoshinobu T, Schöning MJ (2017) Towards addressability of light-addressable potentiometric sensors: shunting effect of non-illuminated region and cross-talk. Sensors Actuators B Chem 244:1071–1079CrossRef
16.
go back to reference Bousse L, Mostarshed S, Hafeman D, Sartore M, Adami M, Nicolini C (1994) Investigation of carrier transport through silicon wafers by photocurrent measurements. J Appl Phys 75:4000–4008CrossRef Bousse L, Mostarshed S, Hafeman D, Sartore M, Adami M, Nicolini C (1994) Investigation of carrier transport through silicon wafers by photocurrent measurements. J Appl Phys 75:4000–4008CrossRef
17.
go back to reference Yoshinobu T, Ecken H, Poghossian A, Simonis A, Iwasaki H, Lüth H, Schöning MJ (2001) Constant-current-mode LAPS (CLAPS) for the detection of penicillin. Electroanalysis 13:733–736CrossRef Yoshinobu T, Ecken H, Poghossian A, Simonis A, Iwasaki H, Lüth H, Schöning MJ (2001) Constant-current-mode LAPS (CLAPS) for the detection of penicillin. Electroanalysis 13:733–736CrossRef
18.
go back to reference Miyamoto K, Sakakita S, Yoshinobu T (2016) A novel data acquisition method for visualization of large pH changes by chemical imaging sensor. ISIJ Int 56:492–494CrossRef Miyamoto K, Sakakita S, Yoshinobu T (2016) A novel data acquisition method for visualization of large pH changes by chemical imaging sensor. ISIJ Int 56:492–494CrossRef
19.
go back to reference Miyamoto K, Wagner T, Yoshinobu T, Kanoh S, Schöning MJ (2011) Phase-mode LAPS and its application to chemical imaging. Sensors Actuators B Chem 154:28–32CrossRef Miyamoto K, Wagner T, Yoshinobu T, Kanoh S, Schöning MJ (2011) Phase-mode LAPS and its application to chemical imaging. Sensors Actuators B Chem 154:28–32CrossRef
20.
go back to reference Krause S, Moritz W, Talabani H, Xu M, Sabot A, Ensell G (2006) Scanning photo-induced impedance microscopy – resolution studies and polymer characterization. Electrochim Acta 51:1423–1430CrossRef Krause S, Moritz W, Talabani H, Xu M, Sabot A, Ensell G (2006) Scanning photo-induced impedance microscopy – resolution studies and polymer characterization. Electrochim Acta 51:1423–1430CrossRef
21.
go back to reference Zhou Y, Chen L, Krause S, Chazalviel JN (2007) Scanning photoinduced impedance microscopy using amorphous silicon photodiode structures. Anal Chem 79:6208–6214PubMedCrossRef Zhou Y, Chen L, Krause S, Chazalviel JN (2007) Scanning photoinduced impedance microscopy using amorphous silicon photodiode structures. Anal Chem 79:6208–6214PubMedCrossRef
22.
go back to reference Zhou Y, Jiang S, Krause S, Chazalviel JN (2007) Biosensor arrays based on the degradation of thin polymer films interrogated by scanning photoinduced impedance microscopy. Anal Chem 79:8974–8978PubMedCrossRef Zhou Y, Jiang S, Krause S, Chazalviel JN (2007) Biosensor arrays based on the degradation of thin polymer films interrogated by scanning photoinduced impedance microscopy. Anal Chem 79:8974–8978PubMedCrossRef
23.
go back to reference Seki A, Motoya K, Watanabe S, Kubo I (1999) Novel sensors for potassium, calcium and magnesium ions based on a silicon transducer as a light-addressable potentiometric sensor. Anal Chim Acta 382:131–136CrossRef Seki A, Motoya K, Watanabe S, Kubo I (1999) Novel sensors for potassium, calcium and magnesium ions based on a silicon transducer as a light-addressable potentiometric sensor. Anal Chim Acta 382:131–136CrossRef
24.
go back to reference Wu Y, Wang P, Ye X, Zhang Q, Li R, Yan W, Zheng X (2001) A novel microphysiometer based on MLAPS for drugs screening. Biosens Bioelectron 16:277–286CrossRef Wu Y, Wang P, Ye X, Zhang Q, Li R, Yan W, Zheng X (2001) A novel microphysiometer based on MLAPS for drugs screening. Biosens Bioelectron 16:277–286CrossRef
25.
go back to reference Ermolenko YE, Yoshinobu T, Mourzina Y, Levichev S, Furuichi K, Vlasov YG, Schöning MJ, Iwasaki H (2002) Photocurable membranes for ion-selective light-addressable potentiometric sensor. Sensors Actuators B Chem 85:79–85CrossRef Ermolenko YE, Yoshinobu T, Mourzina Y, Levichev S, Furuichi K, Vlasov YG, Schöning MJ, Iwasaki H (2002) Photocurable membranes for ion-selective light-addressable potentiometric sensor. Sensors Actuators B Chem 85:79–85CrossRef
26.
go back to reference Mourzina YG, Ermolenko YE, Yoshinobu T, Vlasov YG, Iwasaki H, Schöning MJ (2003) Anion-selective light-addressable potentiometric sensors (LAPS) for the determination of nitrate and sulphate ions. Sensors Actuators B Chem 91:32–38CrossRef Mourzina YG, Ermolenko YE, Yoshinobu T, Vlasov YG, Iwasaki H, Schöning MJ (2003) Anion-selective light-addressable potentiometric sensors (LAPS) for the determination of nitrate and sulphate ions. Sensors Actuators B Chem 91:32–38CrossRef
27.
go back to reference Yoshinobu T, Iwasaki H, Ui Y, Furuichi K, Ermolenko YE, Mourzina Y, Wagner T, Näther N, Schöning MJ (2005) The light-addressable potentiometric sensor for multi-ion sensing and imaging. Methods 37:94–102PubMedCrossRef Yoshinobu T, Iwasaki H, Ui Y, Furuichi K, Ermolenko YE, Mourzina Y, Wagner T, Näther N, Schöning MJ (2005) The light-addressable potentiometric sensor for multi-ion sensing and imaging. Methods 37:94–102PubMedCrossRef
28.
go back to reference Ha D, Hu N, Wu CX, Kirsanov D, Legin A, Khaydukova M, Wang P (2012) Novel structured light-addressable potentiometric sensor array based on PVC membrane for determination of heavy metals. Sensors Actuators B Chem 174:59–64CrossRef Ha D, Hu N, Wu CX, Kirsanov D, Legin A, Khaydukova M, Wang P (2012) Novel structured light-addressable potentiometric sensor array based on PVC membrane for determination of heavy metals. Sensors Actuators B Chem 174:59–64CrossRef
29.
go back to reference Ismail ABM, Furuichi K, Yoshinobu T, Iwasaki H (2002) Light-addressable potentiometric fluoride (F−) sensor. Sensors Actuators B Chem 86:94–97CrossRef Ismail ABM, Furuichi K, Yoshinobu T, Iwasaki H (2002) Light-addressable potentiometric fluoride (F) sensor. Sensors Actuators B Chem 86:94–97CrossRef
30.
go back to reference Kloock JP, Moreno L, Bratov A, Huachupoma S, Xu J, Wagner T, Yoshinobu T, Ermolenko YE, Vlasov YG, Schöning MJ (2006) PLD-prepared cadmium sensors based on chalcogenide glasses–ISFET, LAPS and μISE semiconductor structures. Sensors Actuators B Chem 118:149–155CrossRef Kloock JP, Moreno L, Bratov A, Huachupoma S, Xu J, Wagner T, Yoshinobu T, Ermolenko YE, Vlasov YG, Schöning MJ (2006) PLD-prepared cadmium sensors based on chalcogenide glasses–ISFET, LAPS and μISE semiconductor structures. Sensors Actuators B Chem 118:149–155CrossRef
31.
go back to reference Lue CE, Lai CS, Chen HY, Yang CM (2010) Light addressable potentiometric sensor with fluorine-terminated hafnium oxide layer for sodium detection. Jpn J Appl Phys 49:04DL05 Lue CE, Lai CS, Chen HY, Yang CM (2010) Light addressable potentiometric sensor with fluorine-terminated hafnium oxide layer for sodium detection. Jpn J Appl Phys 49:04DL05
32.
go back to reference Wang JC, Ye YR, Lin YH (2015) Light-addressable potentiometric sensor with nitrogen-incorporated ceramic Sm2O3 membrane for chloride ions detection. J Am Ceram Soc 98:443–447CrossRef Wang JC, Ye YR, Lin YH (2015) Light-addressable potentiometric sensor with nitrogen-incorporated ceramic Sm2O3 membrane for chloride ions detection. J Am Ceram Soc 98:443–447CrossRef
33.
go back to reference Mourzina Y, Yoshinobu T, Schubert J, Lüth H, Iwasaki H, Schöning MJ (2001) Ion-selective light-addressable potentiometric sensor (LAPS) with chalcogenide thin film prepared by pulsed laser deposition. Sensors Actuators B Chem 80:136–140CrossRef Mourzina Y, Yoshinobu T, Schubert J, Lüth H, Iwasaki H, Schöning MJ (2001) Ion-selective light-addressable potentiometric sensor (LAPS) with chalcogenide thin film prepared by pulsed laser deposition. Sensors Actuators B Chem 80:136–140CrossRef
34.
go back to reference Kloock JP, Mourzina YG, Ermolenko YE, Doll T, Schubert J, Schöning MJ (2004) Inorganic thin-film sensor membranes with PLD-prepared chalcogenide glasses: challenges and implementation. Sensors 4:156–162CrossRefPubMedCentral Kloock JP, Mourzina YG, Ermolenko YE, Doll T, Schubert J, Schöning MJ (2004) Inorganic thin-film sensor membranes with PLD-prepared chalcogenide glasses: challenges and implementation. Sensors 4:156–162CrossRefPubMedCentral
35.
go back to reference Men H, Zou SF, Legin A, Wang P (2005) A novel mercury ion selective thin film sensor. Chin J Anal Chem 33:428–431 Men H, Zou SF, Legin A, Wang P (2005) A novel mercury ion selective thin film sensor. Chin J Anal Chem 33:428–431
36.
go back to reference Hu W, Cai H, Fu J, Wang P, Yang G (2008) Line-scanning LAPS array for measurement of heavy metal ions with micro-lens array based on MEMS. Sensors Actuators B Chem 129:397–403CrossRef Hu W, Cai H, Fu J, Wang P, Yang G (2008) Line-scanning LAPS array for measurement of heavy metal ions with micro-lens array based on MEMS. Sensors Actuators B Chem 129:397–403CrossRef
37.
go back to reference Ermolenko YE, Yoshinobu T, Mourzina YG, Vlasov YG, Schöning MJ, Iwasaki H (2004) Laser-scanned silicon transducer (LSST) as a multisensor system. Sensors Actuators B Chem 103:457–462CrossRef Ermolenko YE, Yoshinobu T, Mourzina YG, Vlasov YG, Schöning MJ, Iwasaki H (2004) Laser-scanned silicon transducer (LSST) as a multisensor system. Sensors Actuators B Chem 103:457–462CrossRef
38.
go back to reference Yang JH, Lu TF, Wang JC, Yang CM, Pijanowska DG, Chin CH, Lue CE, Lai CS (2013) LAPS with nanoscaled and highly polarized HfO2 by CF4 plasma for NH4 + detection. Sensors Actuators B Chem 180:71–76CrossRef Yang JH, Lu TF, Wang JC, Yang CM, Pijanowska DG, Chin CH, Lue CE, Lai CS (2013) LAPS with nanoscaled and highly polarized HfO2 by CF4 plasma for NH4 + detection. Sensors Actuators B Chem 180:71–76CrossRef
39.
go back to reference Seki A, Ikeda S, Kubo I, Karube I (1998) Biosensors based on light-addressable potentiometric sensors for urea, penicillin and glucose. Anal Chim Acta 373:9–13CrossRef Seki A, Ikeda S, Kubo I, Karube I (1998) Biosensors based on light-addressable potentiometric sensors for urea, penicillin and glucose. Anal Chim Acta 373:9–13CrossRef
40.
go back to reference Poghossian A, Yoshinobu T, Simonis A, Ecken H, Lüth H, Schöning MJ (2001) Penicillin detection by means of field-effect based sensors: EnFET, capacitive EIS sensor or LAPS? Sensors Actuators B Chem 78:237–242CrossRef Poghossian A, Yoshinobu T, Simonis A, Ecken H, Lüth H, Schöning MJ (2001) Penicillin detection by means of field-effect based sensors: EnFET, capacitive EIS sensor or LAPS? Sensors Actuators B Chem 78:237–242CrossRef
41.
go back to reference Jang SW, Lee SY, Yuan H, Kim DE, Kwon DH, Kang SW (2007) High-sensitivity membranes of light addressable potentiometric sensor for penicillin detection. Sens Mater 18:115–124 Jang SW, Lee SY, Yuan H, Kim DE, Kwon DH, Kang SW (2007) High-sensitivity membranes of light addressable potentiometric sensor for penicillin detection. Sens Mater 18:115–124
42.
go back to reference Siqueira JR, Werner CF, Bäcker M, Poghossian A, Zucolotto V, Oliveira ON, Schöning MJ (2009) Layer-by-layer assembly of carbon nanotubes incorporated in light-addressable potentiometric sensors. J Phys Chem C 113:14765–14770CrossRef Siqueira JR, Werner CF, Bäcker M, Poghossian A, Zucolotto V, Oliveira ON, Schöning MJ (2009) Layer-by-layer assembly of carbon nanotubes incorporated in light-addressable potentiometric sensors. J Phys Chem C 113:14765–14770CrossRef
43.
go back to reference Bousse L, Kirk G, Sigal G (1990) Biosensors for detection of enzymes immobilized in microvolume reaction chambers. Sensors Actuators B Chem 1:555–560CrossRef Bousse L, Kirk G, Sigal G (1990) Biosensors for detection of enzymes immobilized in microvolume reaction chambers. Sensors Actuators B Chem 1:555–560CrossRef
44.
go back to reference Paddeu S, Fanigliulo A, Lanzi M, Dubrovsky T, Nicolini C (1995) LB-based PAB immunosystem: activity of an immobilized urease monolayer. Sensors Actuators B Chem 25:876–882CrossRef Paddeu S, Fanigliulo A, Lanzi M, Dubrovsky T, Nicolini C (1995) LB-based PAB immunosystem: activity of an immobilized urease monolayer. Sensors Actuators B Chem 25:876–882CrossRef
45.
go back to reference Miyamoto K, Yoshida M, Sakai T, Matsuzaka A, Wagner T, Kanoh S, Yoshinobu T, Schöning MJ (2011) Differential setup of light-addressable potentiometric sensor with an enzyme reactor in a flow channel. Jpn J Appl Phys 50:04DL08CrossRef Miyamoto K, Yoshida M, Sakai T, Matsuzaka A, Wagner T, Kanoh S, Yoshinobu T, Schöning MJ (2011) Differential setup of light-addressable potentiometric sensor with an enzyme reactor in a flow channel. Jpn J Appl Phys 50:04DL08CrossRef
46.
go back to reference Mourzina IG, Yoshinobu T, Ermolenko YE, Vlasov YG, Schöning MJ, Iwasaki H (2004) Immobilization of urease and cholinesterase on the surface of semiconductor transducer for the development of light-addressable potentiometric sensors. Microchim Acta 144:41–50CrossRef Mourzina IG, Yoshinobu T, Ermolenko YE, Vlasov YG, Schöning MJ, Iwasaki H (2004) Immobilization of urease and cholinesterase on the surface of semiconductor transducer for the development of light-addressable potentiometric sensors. Microchim Acta 144:41–50CrossRef
47.
go back to reference Adami M, Piras L, Lanzi M, Fanigliulo A, Vakula S, Nicoli C (1994) Monitoring of enzymatic activity and quantitative measurements of substrates by means of a newly designed silicon-based potentiometric sensor. Sensors Actuators B Chem 18:178–182CrossRef Adami M, Piras L, Lanzi M, Fanigliulo A, Vakula S, Nicoli C (1994) Monitoring of enzymatic activity and quantitative measurements of substrates by means of a newly designed silicon-based potentiometric sensor. Sensors Actuators B Chem 18:178–182CrossRef
48.
go back to reference Werner CF, Takenaga S, Taki H, Sawada K, Schöning MJ (2013) Comparison of label-free ACh-imaging sensors based on CCD and LAPS. Sensors Actuators B Chem 177:745–752CrossRef Werner CF, Takenaga S, Taki H, Sawada K, Schöning MJ (2013) Comparison of label-free ACh-imaging sensors based on CCD and LAPS. Sensors Actuators B Chem 177:745–752CrossRef
49.
go back to reference Abouzar MH, Poghossian A, Siqueira JR, Oliveira ON, Moritz W, Schöning MJ (2010) Capacitive electrolyte – insulator – semiconductor structures functionalised with a polyelectrolyte/enzyme multilayer: new strategy for enhanced field-effect biosensing. Phys Status Solidi A 207:884–890CrossRef Abouzar MH, Poghossian A, Siqueira JR, Oliveira ON, Moritz W, Schöning MJ (2010) Capacitive electrolyte – insulator – semiconductor structures functionalised with a polyelectrolyte/enzyme multilayer: new strategy for enhanced field-effect biosensing. Phys Status Solidi A 207:884–890CrossRef
50.
go back to reference Sassolas A, Blum LJ, Leca-Bouvier BD (2012) Immobilization strategies to develop enzymatic biosensors. Biotechnol Adv 30:489–511PubMedCrossRef Sassolas A, Blum LJ, Leca-Bouvier BD (2012) Immobilization strategies to develop enzymatic biosensors. Biotechnol Adv 30:489–511PubMedCrossRef
51.
go back to reference Colston JT, Kumar P, Rael ED, Tsin ATC, Valdes JJ, Chambers JP (1993) Detection of sub-nanogram quantities of Mojave toxin via enzyme immunoassay with light addressable potentiometric detector. Biosens Bioelectron 8:117–121PubMedCrossRef Colston JT, Kumar P, Rael ED, Tsin ATC, Valdes JJ, Chambers JP (1993) Detection of sub-nanogram quantities of Mojave toxin via enzyme immunoassay with light addressable potentiometric detector. Biosens Bioelectron 8:117–121PubMedCrossRef
52.
go back to reference Gehring AG, Patterson DL, Tu SI (1998) Use of a light-addressable potentiometric sensor for the detection of Escherichia coli O157:H7. Anal Biochem 258:293–298PubMedCrossRef Gehring AG, Patterson DL, Tu SI (1998) Use of a light-addressable potentiometric sensor for the detection of Escherichia coli O157:H7. Anal Biochem 258:293–298PubMedCrossRef
53.
go back to reference Dill K, Stanker LH, Young CR (1999) Detection of salmonella in poultry using a silicon chip-based biosensor. J Biochem Biophys Methods 41:61–67PubMedCrossRef Dill K, Stanker LH, Young CR (1999) Detection of salmonella in poultry using a silicon chip-based biosensor. J Biochem Biophys Methods 41:61–67PubMedCrossRef
54.
go back to reference Lee WE, Thompson HG, Hall JG, Bader DE (2000) Rapid detection and identification of biological and chemical agents by immunoassay, gene probe assay and enzyme inhibition using a silicon-based biosensor. Biosens Bioelectron 14:795–804PubMedCrossRef Lee WE, Thompson HG, Hall JG, Bader DE (2000) Rapid detection and identification of biological and chemical agents by immunoassay, gene probe assay and enzyme inhibition using a silicon-based biosensor. Biosens Bioelectron 14:795–804PubMedCrossRef
55.
go back to reference Hu WG, Thompson HG, Alvi AZ, Nagata LP, Suresh MR, Fulton RE (2004) Development of immunofiltration assay by light addressable potentiometric sensor with genetically biotinylated recombinant antibody for rapid identification of Venezuelan equine encephalitis virus. J Immunol Methods 289:27–35PubMedCrossRef Hu WG, Thompson HG, Alvi AZ, Nagata LP, Suresh MR, Fulton RE (2004) Development of immunofiltration assay by light addressable potentiometric sensor with genetically biotinylated recombinant antibody for rapid identification of Venezuelan equine encephalitis virus. J Immunol Methods 289:27–35PubMedCrossRef
56.
go back to reference Mosiello L, Laconi C, Del Gallo M, Ercole C, Lepidi A (2003) Development of a monoclonal antibody based potentiometric biosensor for terbuthylazine detection. Sensors Actuators B Chem 95:315–320CrossRef Mosiello L, Laconi C, Del Gallo M, Ercole C, Lepidi A (2003) Development of a monoclonal antibody based potentiometric biosensor for terbuthylazine detection. Sensors Actuators B Chem 95:315–320CrossRef
57.
go back to reference Liang J, Guan M, Huang G, Qiu H, Chen Z, Li G, Huang Y (2016) Highly sensitive covalently functionalized light-addressable potentiometric sensor for determination of biomarker. Mater Sci Eng C 63:185–191CrossRef Liang J, Guan M, Huang G, Qiu H, Chen Z, Li G, Huang Y (2016) Highly sensitive covalently functionalized light-addressable potentiometric sensor for determination of biomarker. Mater Sci Eng C 63:185–191CrossRef
58.
go back to reference Jia Y, Gao C, Feng D, Wu M, Liu Y, Chen X, Xing K, Feng X (2011) Bio-initiated light addressable potentiometric sensor for unlabeled biodetection and its MEDICI simulation. Analyst 136:4533–4538PubMedCrossRef Jia Y, Gao C, Feng D, Wu M, Liu Y, Chen X, Xing K, Feng X (2011) Bio-initiated light addressable potentiometric sensor for unlabeled biodetection and its MEDICI simulation. Analyst 136:4533–4538PubMedCrossRef
59.
go back to reference Ercole C, Gallo MD, Mosiello L, Baccella S, Lepidi A (2003) Escherichia coli detection in vegetable food by a potentiometric biosensor. Sensors Actuators B Chem 91:163–168CrossRef Ercole C, Gallo MD, Mosiello L, Baccella S, Lepidi A (2003) Escherichia coli detection in vegetable food by a potentiometric biosensor. Sensors Actuators B Chem 91:163–168CrossRef
60.
go back to reference Wu C, Du L, Zou L, Zhao L, Wang P (2012) An ATP sensitive light addressable biosensor for extracellular monitoring of single taste receptor cell. Biomed Microdevices 14:1047–1053PubMedCrossRef Wu C, Du L, Zou L, Zhao L, Wang P (2012) An ATP sensitive light addressable biosensor for extracellular monitoring of single taste receptor cell. Biomed Microdevices 14:1047–1053PubMedCrossRef
61.
go back to reference Jia Y, Qin M, Zhang H, Niu W, Li X, Wang L, Li X, Bai Y, Cao Y, Feng X (2007) Label-free biosensor: a novel phage-modified light addressable potentiometric sensor system for cancer cell monitoring. Biosens Bioelectron 22:3261–3266PubMedCrossRef Jia Y, Qin M, Zhang H, Niu W, Li X, Wang L, Li X, Bai Y, Cao Y, Feng X (2007) Label-free biosensor: a novel phage-modified light addressable potentiometric sensor system for cancer cell monitoring. Biosens Bioelectron 22:3261–3266PubMedCrossRef
62.
go back to reference Jia YF, Gao CY, He J, Feng DF, Xing KL, Wu M, Liu Y, Cai WS, Feng XZ (2012) Unlabeled multi tumor marker detection system based on bioinitiated light addressable potentiometric sensor. Analyst 137:3806–3813PubMedCrossRef Jia YF, Gao CY, He J, Feng DF, Xing KL, Wu M, Liu Y, Cai WS, Feng XZ (2012) Unlabeled multi tumor marker detection system based on bioinitiated light addressable potentiometric sensor. Analyst 137:3806–3813PubMedCrossRef
63.
go back to reference Zong X, Wu C, Wu X, Lu Y, Wang P (2009) A non-labeled DNA biosensor based on light addressable potentiometric sensor modified with TiO2 thin film. J Zhejiang Univ Sci B 10:860–866PubMedPubMedCentralCrossRef Zong X, Wu C, Wu X, Lu Y, Wang P (2009) A non-labeled DNA biosensor based on light addressable potentiometric sensor modified with TiO2 thin film. J Zhejiang Univ Sci B 10:860–866PubMedPubMedCentralCrossRef
64.
go back to reference Wu C, Bronder TS, Poghossian A, Werner CF, Bäcker M, Schöning MJ (2014) Label-free electrical detection of DNA with a multi-spot LAPS: first step towards light-addressable DNA chips. Phys Status Solidi A 211:1423–1428CrossRef Wu C, Bronder TS, Poghossian A, Werner CF, Bäcker M, Schöning MJ (2014) Label-free electrical detection of DNA with a multi-spot LAPS: first step towards light-addressable DNA chips. Phys Status Solidi A 211:1423–1428CrossRef
65.
go back to reference Poghossian A, Schöning MJ (2014) Label-free sensing of biomolecules with field-effect devices for clinical applications. Electroanalysis 26:1197–1213CrossRef Poghossian A, Schöning MJ (2014) Label-free sensing of biomolecules with field-effect devices for clinical applications. Electroanalysis 26:1197–1213CrossRef
66.
go back to reference Bronder TS, Poghossian A, Scheja S, Wu C, Keusgen M, Mewes D, Schöning MJ (2015) DNA immobilization and hybridization detection by the intrinsic molecular charge using capacitive field-effect sensors modified with a charged weak polyelectrolyte layer. ACS Appl Mater Interfaces 7:20068–20075PubMedCrossRef Bronder TS, Poghossian A, Scheja S, Wu C, Keusgen M, Mewes D, Schöning MJ (2015) DNA immobilization and hybridization detection by the intrinsic molecular charge using capacitive field-effect sensors modified with a charged weak polyelectrolyte layer. ACS Appl Mater Interfaces 7:20068–20075PubMedCrossRef
67.
go back to reference Zhang GJ, Zhang G, Chua JH, Chee RE, Wong EH, Agarwal A, Buddharaju KD, Singh N, Gao Z, Balasubramanian N (2008) DNA sensing by silicon nanowire: charge layer distance dependence. Nano Lett 8:1066–1070PubMedCrossRef Zhang GJ, Zhang G, Chua JH, Chee RE, Wong EH, Agarwal A, Buddharaju KD, Singh N, Gao Z, Balasubramanian N (2008) DNA sensing by silicon nanowire: charge layer distance dependence. Nano Lett 8:1066–1070PubMedCrossRef
68.
go back to reference Poghossian A, Schöning MJ (2017) Nanomaterial-modified capacitive field-effect biosensors (Chapter 1). In: Springer series on chemical sensors and biosensors (Methods and applications). Springer, Heidelberg (this volume) Poghossian A, Schöning MJ (2017) Nanomaterial-modified capacitive field-effect biosensors (Chapter 1). In: Springer series on chemical sensors and biosensors (Methods and applications). Springer, Heidelberg (this volume)
69.
go back to reference Wu C, Bronder TS, Poghossian A, Werner CF, Schoning MJ (2015) Label-free detection of DNA using a light-addressable potentiometric sensor modified with a positively charged polyelectrolyte layer. Nanoscale 7:6143–6150PubMedCrossRef Wu C, Bronder TS, Poghossian A, Werner CF, Schoning MJ (2015) Label-free detection of DNA using a light-addressable potentiometric sensor modified with a positively charged polyelectrolyte layer. Nanoscale 7:6143–6150PubMedCrossRef
70.
go back to reference Wu C, Poghossian A, Bronder TS, Schöning MJ (2016) Sensing of double-stranded DNA molecules by their intrinsic molecular charge using the light-addressable potentiometric sensor. Sensors Actuators B Chem 229:506–512CrossRef Wu C, Poghossian A, Bronder TS, Schöning MJ (2016) Sensing of double-stranded DNA molecules by their intrinsic molecular charge using the light-addressable potentiometric sensor. Sensors Actuators B Chem 229:506–512CrossRef
71.
go back to reference Evtugyn GA, Hianik T (2011) Layer-by-layer polyelectrolyte assembles involving DNA as a platform for DNA sensors. Curr Anal Chem 7:8–34CrossRef Evtugyn GA, Hianik T (2011) Layer-by-layer polyelectrolyte assembles involving DNA as a platform for DNA sensors. Curr Anal Chem 7:8–34CrossRef
72.
go back to reference Yoshinobu T, Miyamoto K, Wagner T, Schöning MJ (2015) Recent developments of chemical imaging sensor systems based on the principle of the light-addressable potentiometric sensor. Sensors Actuators B Chem 207:926–932CrossRef Yoshinobu T, Miyamoto K, Wagner T, Schöning MJ (2015) Recent developments of chemical imaging sensor systems based on the principle of the light-addressable potentiometric sensor. Sensors Actuators B Chem 207:926–932CrossRef
73.
go back to reference Yoshinobu T, Miyamoto K, Werner CF, Poghossian A, Wagner T, Schöning MJ (2017) Light-addressable potentiometric sensors for quantitative spatial imaging of chemical species. Annu Rev Anal Chem 10:225–246CrossRef Yoshinobu T, Miyamoto K, Werner CF, Poghossian A, Wagner T, Schöning MJ (2017) Light-addressable potentiometric sensors for quantitative spatial imaging of chemical species. Annu Rev Anal Chem 10:225–246CrossRef
74.
go back to reference Inoue S, Nakao M, Yoshinobu T, Iwasaki H (1996) Chemical-imaging sensor using enzyme. Sensors Actuators B Chem 32:23–26CrossRef Inoue S, Nakao M, Yoshinobu T, Iwasaki H (1996) Chemical-imaging sensor using enzyme. Sensors Actuators B Chem 32:23–26CrossRef
75.
go back to reference Uchida H, Zhang WY, Katsube T (1996) High-speed chemical image sensor with digital LAPS system. Sensors Actuators B Chem 34:446–449CrossRef Uchida H, Zhang WY, Katsube T (1996) High-speed chemical image sensor with digital LAPS system. Sensors Actuators B Chem 34:446–449CrossRef
76.
go back to reference Das A, Chen TC, Yang CM, Lai CS (2014) A high-speed, flexible-scanning chemical imaging system using a light-addressable potentiometric sensor integrated with an analog micromirror. Sensors Actuators B Chem 198:225–232CrossRef Das A, Chen TC, Yang CM, Lai CS (2014) A high-speed, flexible-scanning chemical imaging system using a light-addressable potentiometric sensor integrated with an analog micromirror. Sensors Actuators B Chem 198:225–232CrossRef
77.
go back to reference Wagner T, Werner CF, Miyamoto K, Schöning MJ, Yoshinobu T (2012) Development and characterisation of a compact light-addressable potentiometric sensor (LAPS) based on the digital light processing (DLP) technology for flexible chemical imaging. Sensors Actuators B Chem 170:34–39CrossRef Wagner T, Werner CF, Miyamoto K, Schöning MJ, Yoshinobu T (2012) Development and characterisation of a compact light-addressable potentiometric sensor (LAPS) based on the digital light processing (DLP) technology for flexible chemical imaging. Sensors Actuators B Chem 170:34–39CrossRef
78.
go back to reference Sartore M, Adami M, Nicolini C, Bousse L, Mostarshed S, Hafeman D (1992) Minority-carrier diffusion length effects on light-addressable potentiometric sensor (LAPS) devices. Sens Actuators A 32:431–436CrossRef Sartore M, Adami M, Nicolini C, Bousse L, Mostarshed S, Hafeman D (1992) Minority-carrier diffusion length effects on light-addressable potentiometric sensor (LAPS) devices. Sens Actuators A 32:431–436CrossRef
79.
go back to reference Nakao M, Yoshinobu T, Iwasaki H (1994) Improvement of spatial-resolution of a laser-scanning pH-imaging sensor. Jpn J Appl Phys 33:L394–L397CrossRef Nakao M, Yoshinobu T, Iwasaki H (1994) Improvement of spatial-resolution of a laser-scanning pH-imaging sensor. Jpn J Appl Phys 33:L394–L397CrossRef
80.
go back to reference Nakao M, Inoue S, Yoshinobu T, Iwasaki H (1996) High-resolution pH imaging sensor for microscopic observation of microorganisms. Sensors Actuators B Chem 34:234–239CrossRef Nakao M, Inoue S, Yoshinobu T, Iwasaki H (1996) High-resolution pH imaging sensor for microscopic observation of microorganisms. Sensors Actuators B Chem 34:234–239CrossRef
81.
go back to reference Parak WJ, Hofmann UG, Gaub HE, Owicki JC (1997) Lateral resolution of light-addressable potentiometric sensors: an experimental and theoretical investigation. Sens Actuators A 63:47–57CrossRef Parak WJ, Hofmann UG, Gaub HE, Owicki JC (1997) Lateral resolution of light-addressable potentiometric sensors: an experimental and theoretical investigation. Sens Actuators A 63:47–57CrossRef
82.
go back to reference George M, Parak WJ, Gerhardt I, Moritz W, Kaesen F, Geiger H, Eisele I, Gaub HE (2000) Investigation of the spatial resolution of the light-addressable potentiometric sensor. Sens Actuators A 86:187–196CrossRef George M, Parak WJ, Gerhardt I, Moritz W, Kaesen F, Geiger H, Eisele I, Gaub HE (2000) Investigation of the spatial resolution of the light-addressable potentiometric sensor. Sens Actuators A 86:187–196CrossRef
83.
go back to reference Ito Y (1998) High-spatial resolution LAPS. Sensors Actuators B Chem 52:107–111CrossRef Ito Y (1998) High-spatial resolution LAPS. Sensors Actuators B Chem 52:107–111CrossRef
84.
go back to reference Moritz W, Gerhardt I, Roden D, Xu M, Krause S (2000) Photocurrent measurements for laterally resolved interface characterization. Fresenius J Anal Chem 367:329–333PubMedCrossRef Moritz W, Gerhardt I, Roden D, Xu M, Krause S (2000) Photocurrent measurements for laterally resolved interface characterization. Fresenius J Anal Chem 367:329–333PubMedCrossRef
85.
go back to reference Moritz W, Yoshinobu T, Finger F, Krause S, Martin-Fernandez M, Schöning MJ (2004) High resolution LAPS using amorphous silicon as the semiconductor material. Sensors Actuators B Chem 103:436–441CrossRef Moritz W, Yoshinobu T, Finger F, Krause S, Martin-Fernandez M, Schöning MJ (2004) High resolution LAPS using amorphous silicon as the semiconductor material. Sensors Actuators B Chem 103:436–441CrossRef
86.
go back to reference Guo Y, Seki K, Miyamoto K, Wagner T, Schöning MJ, Yoshinobu T (2014) Novel photoexcitation method for light-addressable potentiometric sensor with higher spatial resolution. Appl Phys Express 7:067301-1–067301-4 Guo Y, Seki K, Miyamoto K, Wagner T, Schöning MJ, Yoshinobu T (2014) Novel photoexcitation method for light-addressable potentiometric sensor with higher spatial resolution. Appl Phys Express 7:067301-1–067301-4
87.
go back to reference Werner CF, Miyamoto K, Wagner T, Schöning MJ, Yoshinobu T (2017) Lateral resolution enhancement of pulse-driven light-addressable potentiometric sensor. Sensors Actuators B Chem 248:961–965CrossRef Werner CF, Miyamoto K, Wagner T, Schöning MJ, Yoshinobu T (2017) Lateral resolution enhancement of pulse-driven light-addressable potentiometric sensor. Sensors Actuators B Chem 248:961–965CrossRef
88.
go back to reference Zhang Q, Wang P, Parak WJ, George M, Zhang G (2001) A novel design of multi-light LAPS based on digital compensation of frequency domain. Sensors Actuators B Chem 73:152–156CrossRef Zhang Q, Wang P, Parak WJ, George M, Zhang G (2001) A novel design of multi-light LAPS based on digital compensation of frequency domain. Sensors Actuators B Chem 73:152–156CrossRef
89.
go back to reference Miyamoto K, Itabashi A, Wagner T, Schöning MJ, Yoshinobu T (2014) High-speed chemical imaging inside a microfluidic channel. Sensors Actuators B Chem 194:521–527CrossRef Miyamoto K, Itabashi A, Wagner T, Schöning MJ, Yoshinobu T (2014) High-speed chemical imaging inside a microfluidic channel. Sensors Actuators B Chem 194:521–527CrossRef
90.
go back to reference Miyamoto K, Sakakita S, Wagner T, Schöning MJ, Yoshinobu T (2015) Application of chemical imaging sensor to in-situ pH imaging in the vicinity of a corroding metal surface. Electrochim Acta 183:137–142CrossRef Miyamoto K, Sakakita S, Wagner T, Schöning MJ, Yoshinobu T (2015) Application of chemical imaging sensor to in-situ pH imaging in the vicinity of a corroding metal surface. Electrochim Acta 183:137–142CrossRef
91.
go back to reference Kohno Y, Matsuki R, Nomura S, Mitsunari K, Nakao M (2001) Neutralization of acid droplets on plant leaf surfaces. Water Air Soil Pollut 130:977–982CrossRef Kohno Y, Matsuki R, Nomura S, Mitsunari K, Nakao M (2001) Neutralization of acid droplets on plant leaf surfaces. Water Air Soil Pollut 130:977–982CrossRef
92.
go back to reference Nakao M, Inoue S, Oishi R, Yoshinobu T, Iwasaki H (1995) Observation of microorganism colonies using a scanning-laser-beam pH-sensing microscope. J Ferment Bioeng 79:163–166CrossRef Nakao M, Inoue S, Oishi R, Yoshinobu T, Iwasaki H (1995) Observation of microorganism colonies using a scanning-laser-beam pH-sensing microscope. J Ferment Bioeng 79:163–166CrossRef
93.
go back to reference Stein B, George M, Gaub HE, Behrends JC, Parak WJ (2003) Spatially resolved monitoring of cellular metabolic activity with a semiconductor-based biosensor. Biosens Bioelectron 18:31–41PubMedCrossRef Stein B, George M, Gaub HE, Behrends JC, Parak WJ (2003) Spatially resolved monitoring of cellular metabolic activity with a semiconductor-based biosensor. Biosens Bioelectron 18:31–41PubMedCrossRef
94.
go back to reference Werner CF, Krumbe C, Schumacher K, Groebel S, Spelthahn H, Stellberg M, Wagner T, Yoshinobu T, Selmer T, Keusgen M, Baumann MEM, Schöning MJ (2011) Determination of the extracellular acidification of Escherichia coli by a light-addressable potentiometric sensor. Phys Status Solidi A 208:1340–1344CrossRef Werner CF, Krumbe C, Schumacher K, Groebel S, Spelthahn H, Stellberg M, Wagner T, Yoshinobu T, Selmer T, Keusgen M, Baumann MEM, Schöning MJ (2011) Determination of the extracellular acidification of Escherichia coli by a light-addressable potentiometric sensor. Phys Status Solidi A 208:1340–1344CrossRef
95.
go back to reference Hiraishi N, Kitasako Y, Nikaido T, Foxton RM, Tagami J, Nomura S (2003) Acidity of conventional luting cements and their diffusion through bovine dentine. Int Endod J 36:622–628PubMedCrossRef Hiraishi N, Kitasako Y, Nikaido T, Foxton RM, Tagami J, Nomura S (2003) Acidity of conventional luting cements and their diffusion through bovine dentine. Int Endod J 36:622–628PubMedCrossRef
96.
go back to reference Murakami K, Kitasako Y, Burrow MF, Tagami J (2006) In vitro pH analysis of active and arrested dentinal caries in extracted human teeth using a micro pH sensor. Dent Mater J 25:423–429PubMedCrossRef Murakami K, Kitasako Y, Burrow MF, Tagami J (2006) In vitro pH analysis of active and arrested dentinal caries in extracted human teeth using a micro pH sensor. Dent Mater J 25:423–429PubMedCrossRef
97.
go back to reference Miyamoto K, Ichimura H, Wagner T, Schöning MJ, Yoshinobu T (2013) Chemical imaging of the concentration profile of ion diffusion in a microfluidic channel. Sensors Actuators B Chem 189:240–245CrossRef Miyamoto K, Ichimura H, Wagner T, Schöning MJ, Yoshinobu T (2013) Chemical imaging of the concentration profile of ion diffusion in a microfluidic channel. Sensors Actuators B Chem 189:240–245CrossRef
98.
go back to reference Wang J, Zhou Y, Watkinson M, Gautrot J, Krause S (2015) High-sensitivity light-addressable potentiometric sensors using silicon on sapphire functionalized with self-assembled organic monolayers. Sensors Actuators B Chem 209:230–236CrossRef Wang J, Zhou Y, Watkinson M, Gautrot J, Krause S (2015) High-sensitivity light-addressable potentiometric sensors using silicon on sapphire functionalized with self-assembled organic monolayers. Sensors Actuators B Chem 209:230–236CrossRef
99.
go back to reference Wang J, Wu F, Watkinson M, Zhu J, Krause S (2015) “Click” patterning of self-assembled monolayers on hydrogen-terminated silicon surfaces and their characterization using light-addressable potentiometric sensors. Langmuir 31:9646–9654PubMedCrossRef Wang J, Wu F, Watkinson M, Zhu J, Krause S (2015) “Click” patterning of self-assembled monolayers on hydrogen-terminated silicon surfaces and their characterization using light-addressable potentiometric sensors. Langmuir 31:9646–9654PubMedCrossRef
100.
go back to reference Wu F, Zhang DW, Wang J, Watkinson M, Krause S (2017) Copper contamination of self-assembled organic monolayer modified silicon surfaces following a ‘click’ reaction characterized with LAPS and SPIM. Langmuir 33:3170–3777PubMedCrossRef Wu F, Zhang DW, Wang J, Watkinson M, Krause S (2017) Copper contamination of self-assembled organic monolayer modified silicon surfaces following a ‘click’ reaction characterized with LAPS and SPIM. Langmuir 33:3170–3777PubMedCrossRef
101.
go back to reference Wang J, Campos I, Wu F, Zhu J, Sukhorukov GB, Palma M, Watkinson M, Krause S (2016) The effect of gold nanoparticles on the impedance of microcapsules visualized by scanning photo-induced impedance microscopy. Electrochim Acta 208:39–46CrossRef Wang J, Campos I, Wu F, Zhu J, Sukhorukov GB, Palma M, Watkinson M, Krause S (2016) The effect of gold nanoparticles on the impedance of microcapsules visualized by scanning photo-induced impedance microscopy. Electrochim Acta 208:39–46CrossRef
102.
go back to reference Zhang DW, Wu F, Wang J, Watkinson M, Krause S (2016) Image detection of yeast Saccharomyces cerevisiae by light-addressable potentiometric sensors (LAPS). Electrochem Commun 72:41–45CrossRef Zhang DW, Wu F, Wang J, Watkinson M, Krause S (2016) Image detection of yeast Saccharomyces cerevisiae by light-addressable potentiometric sensors (LAPS). Electrochem Commun 72:41–45CrossRef
Metadata
Title
(Bio-)chemical Sensing and Imaging by LAPS and SPIM
Authors
Tatsuo Yoshinobu
Steffi Krause
Ko-ichiro Miyamoto
Carl Frederik Werner
Arshak Poghossian
Torsten Wagner
Michael J. Schöning
Copyright Year
2018
DOI
https://doi.org/10.1007/5346_2017_22

Premium Partners