Skip to main content
Top

2018 | OriginalPaper | Chapter

15. Biomaterials and Devices in Hard Tissue Augmentation

Authors : Vasif Hasirci, Nesrin Hasirci

Published in: Fundamentals of Biomaterials

Publisher: Springer New York

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Bone loss or damage can result from illnesses such as cancer and osteoporosis or by trauma sustained in an accident. The lost bone has to be substituted using alternative materials or methods such as tissue engineering or additive manufacturing, while damages like cracks or breaks are repaired by use of implants such as fracture fixation devices in the form of screws, wires, pins, staples, or more complex load-bearing devices until healing is achieved. There are five types of bone in the human body. These are the long bones, femur (upper leg), tibia (lower leg), and humerus (upper arm); short bones, carpals (wrist) and tarsals (ankle); flat bones, scapula (shoulder bone), sternum (chest bone), cranium (skull), pelvis, and ribs; irregular bones, vertebrae, sacrum (lower end of the vertebra), and mandible (lower jaw); and sesamoid bones, bones in tendons (patella and pisiform).

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Andani MT, Moghaddam NS, Haberland C, Dean D, Miller MJ, Elahini M (2014) Metals for bone implants. Part 1. Powder metallurgy and implant rendering. Acta Biomater 10(10):4058–4070CrossRef Andani MT, Moghaddam NS, Haberland C, Dean D, Miller MJ, Elahini M (2014) Metals for bone implants. Part 1. Powder metallurgy and implant rendering. Acta Biomater 10(10):4058–4070CrossRef
2.
go back to reference Patel A, Li L, Anand A (2014) Systematic review: functional outcomes and complications of intramedullary nailing versus plate fixation for both-bone diaphyseal forearm fractures in children, injury. Int J Care Injured 45:1135–1143CrossRef Patel A, Li L, Anand A (2014) Systematic review: functional outcomes and complications of intramedullary nailing versus plate fixation for both-bone diaphyseal forearm fractures in children, injury. Int J Care Injured 45:1135–1143CrossRef
3.
go back to reference de Dompsure RB, Peter R, Hoffmeyer P (2010) Uninfected nonunion of the humeral diaphyses: Review of 21 patients treated with shingling, compression plate, and autologous bone graft. Orthop Traumatol Surg Res 96:139–146CrossRef de Dompsure RB, Peter R, Hoffmeyer P (2010) Uninfected nonunion of the humeral diaphyses: Review of 21 patients treated with shingling, compression plate, and autologous bone graft. Orthop Traumatol Surg Res 96:139–146CrossRef
4.
go back to reference Kim SJ, Jo YH, Choi WS, Lee CH, Lee BG, Kim JH, Lee KH (2017) Biomechanical properties of 3-dimensional printed volar locking distal radius plate: comparison with conventional volar locking plate. J Hand Surg Am 42(9):747.e1–747.e6CrossRef Kim SJ, Jo YH, Choi WS, Lee CH, Lee BG, Kim JH, Lee KH (2017) Biomechanical properties of 3-dimensional printed volar locking distal radius plate: comparison with conventional volar locking plate. J Hand Surg Am 42(9):747.e1–747.e6CrossRef
5.
go back to reference Cuppone M, Seedhom BB, Berry E, Ostell AE (2004) The longitudinal Young's modulus of cortical bone in the midshaft of human femur and its correlation with CT scanning data. Calcif Tissue Int 74(3):302–309CrossRef Cuppone M, Seedhom BB, Berry E, Ostell AE (2004) The longitudinal Young's modulus of cortical bone in the midshaft of human femur and its correlation with CT scanning data. Calcif Tissue Int 74(3):302–309CrossRef
6.
go back to reference Mehboob H, Chang S-H (2014) Evaluation of the development of tissue phenotypes: Bone fracture healing using functionally graded material composite bone plates. Compos Struct 117:105–113CrossRef Mehboob H, Chang S-H (2014) Evaluation of the development of tissue phenotypes: Bone fracture healing using functionally graded material composite bone plates. Compos Struct 117:105–113CrossRef
7.
go back to reference Fujihara K, Yoshida E, Nakai A, Ramakrishna S, Hamada H (2007) Influence of micro-structures on bending properties of braided laminated composites. Compos Sci Technol 67:2191–2198CrossRef Fujihara K, Yoshida E, Nakai A, Ramakrishna S, Hamada H (2007) Influence of micro-structures on bending properties of braided laminated composites. Compos Sci Technol 67:2191–2198CrossRef
8.
go back to reference Kim HJ, Kim SH, Chang SH (2011) Bio-mechanical analysis of a fractured tibia with composite bone plates according to the diaphyseal oblique fracture angle. Compos Part B 42(4):666–674CrossRef Kim HJ, Kim SH, Chang SH (2011) Bio-mechanical analysis of a fractured tibia with composite bone plates according to the diaphyseal oblique fracture angle. Compos Part B 42(4):666–674CrossRef
9.
go back to reference Kharazi AZ, Fathi MH, Bahmani F, Fanian H (2011) Partially resorbable composite bone plate with controlled degradation rate, desired mechanical properties and bioactivity. Polym Degrad Stab 96:2055–2063CrossRef Kharazi AZ, Fathi MH, Bahmani F, Fanian H (2011) Partially resorbable composite bone plate with controlled degradation rate, desired mechanical properties and bioactivity. Polym Degrad Stab 96:2055–2063CrossRef
10.
go back to reference Hayashi M, Muramatsu H, Sato M, Tomizuka Y, Inoue M, Yoshimoto S (2013) Surgical treatment of facial fracture by using unsintered hydroxyapatite particles/poly L-lactide composite device (OSTEOTRANS MX): a clinical study on 17 cases. J Craniomaxillofac Surg 41:783–788CrossRef Hayashi M, Muramatsu H, Sato M, Tomizuka Y, Inoue M, Yoshimoto S (2013) Surgical treatment of facial fracture by using unsintered hydroxyapatite particles/poly L-lactide composite device (OSTEOTRANS MX): a clinical study on 17 cases. J Craniomaxillofac Surg 41:783–788CrossRef
11.
go back to reference Degala S, Shetty S, Ramya S (2013) Fixation of zygomatic and mandibular fractures with biodegradable plates. Ann Maxillofac Surg 3(1):25CrossRef Degala S, Shetty S, Ramya S (2013) Fixation of zygomatic and mandibular fractures with biodegradable plates. Ann Maxillofac Surg 3(1):25CrossRef
12.
go back to reference Lind M, Feller J, Webster KE (2009) Tibial bone tunnel widening is reduced by polylactate/hydroxyapatite interference screws compared to metal screws after ACL reconstruction with hamstring grafts. Knee 16(6):447–451CrossRef Lind M, Feller J, Webster KE (2009) Tibial bone tunnel widening is reduced by polylactate/hydroxyapatite interference screws compared to metal screws after ACL reconstruction with hamstring grafts. Knee 16(6):447–451CrossRef
13.
go back to reference Vázquez-Morales DE, Dyalram-Silverberg D, Lazow SK, Berger JR (2013) Treatment of mandible fractures using resorbable plates with a mean of 3 weeks maxillomandibular fixation:a prospective study. Oral Surg Oral Med Oral Pathol Oral Radiol 115:25–28CrossRef Vázquez-Morales DE, Dyalram-Silverberg D, Lazow SK, Berger JR (2013) Treatment of mandible fractures using resorbable plates with a mean of 3 weeks maxillomandibular fixation:a prospective study. Oral Surg Oral Med Oral Pathol Oral Radiol 115:25–28CrossRef
14.
go back to reference Kim JY, Lee YH, Gong HS, Lee SL, Lee SK, Baek GH (2013) Use of Kirschner wires with eyelets for tension band wiring of olecranon fractures. J Hand Surg Am 38(9):1762–1767CrossRef Kim JY, Lee YH, Gong HS, Lee SL, Lee SK, Baek GH (2013) Use of Kirschner wires with eyelets for tension band wiring of olecranon fractures. J Hand Surg Am 38(9):1762–1767CrossRef
15.
go back to reference Nobile F, Carta S, Fortina M, Santoro P, Meccariello L, Ferrata P (2016) Displaced 3-and 4-part proximal humeral fractures: evaluation and management with an intramedullary nail within 48 h, in the emergency department. J Acute Dis 5(2):154–159CrossRef Nobile F, Carta S, Fortina M, Santoro P, Meccariello L, Ferrata P (2016) Displaced 3-and 4-part proximal humeral fractures: evaluation and management with an intramedullary nail within 48 h, in the emergency department. J Acute Dis 5(2):154–159CrossRef
16.
go back to reference Mullett JH, Shannon F, Nöel J, Lawlor G, Lee TC, O’Rourke SK (2000) K-wire position in tension band wiring of the olecranon—a comparison of two techniques. Injury 31(6):427–431CrossRef Mullett JH, Shannon F, Nöel J, Lawlor G, Lee TC, O’Rourke SK (2000) K-wire position in tension band wiring of the olecranon—a comparison of two techniques. Injury 31(6):427–431CrossRef
17.
go back to reference Chen Q, Thouas GA (2015) Metallic implant biomaterials. Mater Sci Eng R Rep 87:1–57CrossRef Chen Q, Thouas GA (2015) Metallic implant biomaterials. Mater Sci Eng R Rep 87:1–57CrossRef
18.
go back to reference Slane J, Vivanco J, Meyerd J, Ploeg H-L, Squire M (2014) Modification of acrylic bone cement with mesoporous silica nanoparticles: Effects on mechanical, fatigue and absorption properties. J Mech Behav Biomed Mater 29:451–461CrossRef Slane J, Vivanco J, Meyerd J, Ploeg H-L, Squire M (2014) Modification of acrylic bone cement with mesoporous silica nanoparticles: Effects on mechanical, fatigue and absorption properties. J Mech Behav Biomed Mater 29:451–461CrossRef
19.
go back to reference Lopes PP, Garcia MP, Fernandes MH, Fernandes MHV (2013) Acrylic formulations containing bioactive and biodegradable fillers to be used as bone cements: properties and biocompatibility assessment. Mater Sci Eng C Mater Biol Appl 33:1289–1299CrossRef Lopes PP, Garcia MP, Fernandes MH, Fernandes MHV (2013) Acrylic formulations containing bioactive and biodegradable fillers to be used as bone cements: properties and biocompatibility assessment. Mater Sci Eng C Mater Biol Appl 33:1289–1299CrossRef
20.
go back to reference Kandalam U et al (2013) Novel bone adhesives: a comparison of bond strengths in vitro. Int J Oral Maxillofac Surg 42:1054–1059CrossRef Kandalam U et al (2013) Novel bone adhesives: a comparison of bond strengths in vitro. Int J Oral Maxillofac Surg 42:1054–1059CrossRef
21.
go back to reference Sakamoto Y, Shimizu Y, Nagasao T, Kishi K (2013) Human cadaver parietal bone samples. J Plast Reconstr Aesthet Surg 67:e88–ee90CrossRef Sakamoto Y, Shimizu Y, Nagasao T, Kishi K (2013) Human cadaver parietal bone samples. J Plast Reconstr Aesthet Surg 67:e88–ee90CrossRef
23.
go back to reference This image belongs to Coronation Dental Specialty Group and licensed under the Creative Commons Attribution-Share Alike 3.0 Unsupported license This image belongs to Coronation Dental Specialty Group and licensed under the Creative Commons Attribution-Share Alike 3.0 Unsupported license
24.
go back to reference Baldassarri M, Zhang Y, Thompson VP, Rekow ED, Stappert CFJ (2011) Reliability and failure modes of implant-supported zirconium-oxide fixed dental prostheses related to veneering techniques. J Dent 39(7):489–498CrossRef Baldassarri M, Zhang Y, Thompson VP, Rekow ED, Stappert CFJ (2011) Reliability and failure modes of implant-supported zirconium-oxide fixed dental prostheses related to veneering techniques. J Dent 39(7):489–498CrossRef
25.
go back to reference Preis V, Hahnel S, Behr M, Bein L, Rosentritt M (2017) In-vitro fatigue and fracture testing of CAD/CAM-materials in implant-supported molar crowns. Dent Mater 33(4):427–433CrossRef Preis V, Hahnel S, Behr M, Bein L, Rosentritt M (2017) In-vitro fatigue and fracture testing of CAD/CAM-materials in implant-supported molar crowns. Dent Mater 33(4):427–433CrossRef
Metadata
Title
Biomaterials and Devices in Hard Tissue Augmentation
Authors
Vasif Hasirci
Nesrin Hasirci
Copyright Year
2018
Publisher
Springer New York
DOI
https://doi.org/10.1007/978-1-4939-8856-3_15

Premium Partners