Abstract

Purpose

Image-guided interventions that use preoperative 3D computed tomography (CT) models are limited by the preoperative segmentation time 3D image and collection of intraoperative registration data. Intraoperative CT imaging can be ergonomically efficient in a direct navigation system if the imaging device is accurately calibrated. A mobile-gantry CT scanner offers improved patient safety but presents technical challenges beyond those of a conventional scanner. The goal was to calibrate an optoelectronic navigation system to mobile-gantry CT with millimeter-level accuracy.

Methods

A custom calibration device was designed and manufactured. The calibrator contained optoelectronic markers for navigation reference and radio-opaque markers for CT reference. Calibrations were performed with a ceiling-mounted optoelectronic camera and with a portable camera, and then verified for accuracy.

Results

The component fiducial registration errors were extremely small, being 0.36 mm, with standard deviation of 0.16 mm, for the ceiling-mounted camera, and 0.05 mm, with standard deviation of 0.01 mm, for the portable camera. The net target registration error, measured as RMS deviation, was 1.58 mm for the ceiling-mounted camera and 0.73 mm for the portable camera.

Conclusions

High-accuracy calibration of the mobile-gantry CT scanner was possible from a single preoperative CT image. A ceiling-mounted optoelectronic camera, which is ergonomically preferable, marginally met the accuracy criteria. The portable camera, which is in widespread use for conventional navigated surgery, had deep sub-millimeter error. This study demonstrates that high accuracy is achievable and offers a system developer options to trade off accuracy and user convenience in direct surgical navigation.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Footnotes
1
Similarly to \(^{H}_{A}T\) and \(^{A}_{I}T\) mentioned earlier, the imaging transform \(^{Y}_{H}T\) was determined using DICOM header “meta-data.”
 
Literature
1.
go back to reference Smith EJ, Al-Sanawi HA, Gammon B, St John PJ, Pichora DR, Ellis RE (2012) Volume slicing of cone-beam computed tomography images for navigation of percutaneous scaphoid fixation. Int J Comput Assist Radiol Surg 7(3):433–444CrossRefPubMed Smith EJ, Al-Sanawi HA, Gammon B, St John PJ, Pichora DR, Ellis RE (2012) Volume slicing of cone-beam computed tomography images for navigation of percutaneous scaphoid fixation. Int J Comput Assist Radiol Surg 7(3):433–444CrossRefPubMed
2.
go back to reference Foley KT, Simon DA, Rampersaud YR (2001) Virtual fluoroscopy: computer-assisted fluoroscopic navigation. Spine 26(4):347–351CrossRefPubMed Foley KT, Simon DA, Rampersaud YR (2001) Virtual fluoroscopy: computer-assisted fluoroscopic navigation. Spine 26(4):347–351CrossRefPubMed
3.
go back to reference Oentoro A, Ellis RE (2010) High-accuracy registration of intraoperative CT imaging. SPIE Med Imaging 762505–762505 Oentoro A, Ellis RE (2010) High-accuracy registration of intraoperative CT imaging. SPIE Med Imaging 762505–762505
4.
go back to reference Ritter D, Mitschke M, Graumann R (2002) Markerless navigation with the intra-operative imaging modality SIREMOBIL Iso-C 3D. Electromedica 70(1):31–36 Ritter D, Mitschke M, Graumann R (2002) Markerless navigation with the intra-operative imaging modality SIREMOBIL Iso-C 3D. Electromedica 70(1):31–36
5.
go back to reference Smith EJ, Oentoro A, Al-Sanawi H, J BGP, St John, Pichora DR, Ellis RE (2010) Calibration and use of intraoperative cone-beam computed tomography: an in-vitro study for wrist fracture. Med Image Comput Comput Assist Interv 359–366 Smith EJ, Oentoro A, Al-Sanawi H, J BGP, St John, Pichora DR, Ellis RE (2010) Calibration and use of intraoperative cone-beam computed tomography: an in-vitro study for wrist fracture. Med Image Comput Comput Assist Interv 359–366
6.
go back to reference Grutzner PA, Hebecker A, Waelti H, Vock B, Nolte LP, Wentzensen A (2003) Clinical study for registration-free 3D-navigation with the SIREMOBIL Iso-C3D mobile C-arm. Electromedica 71(1):7–16 Grutzner PA, Hebecker A, Waelti H, Vock B, Nolte LP, Wentzensen A (2003) Clinical study for registration-free 3D-navigation with the SIREMOBIL Iso-C3D mobile C-arm. Electromedica 71(1):7–16
7.
go back to reference Hott JS, Deshmukh VR, Klopfenstein JD, Sonntag VKH, Dickman CA, Spetzler RF, Papadopoulos SM (2004) Intraoperative Iso-C C-arm navigation in craniospinal surgery: the first 60 cases. Neurosurg 54(5):1131–1137CrossRef Hott JS, Deshmukh VR, Klopfenstein JD, Sonntag VKH, Dickman CA, Spetzler RF, Papadopoulos SM (2004) Intraoperative Iso-C C-arm navigation in craniospinal surgery: the first 60 cases. Neurosurg 54(5):1131–1137CrossRef
8.
go back to reference Richter M, Geerling J, Zech S, Goesling T, Krettek C (2005) Intraoperative three-dimensional imaging with a motorized mobile C-arm (SIREMOBIL ISO-C-3D) in foot and ankle trauma care: A preliminary report. J Orthop Trauma 19(4):259–266CrossRefPubMed Richter M, Geerling J, Zech S, Goesling T, Krettek C (2005) Intraoperative three-dimensional imaging with a motorized mobile C-arm (SIREMOBIL ISO-C-3D) in foot and ankle trauma care: A preliminary report. J Orthop Trauma 19(4):259–266CrossRefPubMed
9.
go back to reference Kendoff D, Citak M, Gardner MJ, Stuebig T, Krettek C, Huefner T (2009) Intraoperative 3D imaging: value and consequences in 248 cases. J Trauma Acute Care Surg 66(1):232–238CrossRef Kendoff D, Citak M, Gardner MJ, Stuebig T, Krettek C, Huefner T (2009) Intraoperative 3D imaging: value and consequences in 248 cases. J Trauma Acute Care Surg 66(1):232–238CrossRef
10.
go back to reference Oentoro A (2009) A system for computer-assisted surgery with intraoperative CT imaging. Master’s thesis, Queen’s University, Kingston Oentoro A (2009) A system for computer-assisted surgery with intraoperative CT imaging. Master’s thesis, Queen’s University, Kingston
11.
go back to reference Al-Sanawi H, Gammon B, Sellens RW, St John P, Smith EJ, Ellis RE, Pichora DR (2012) Percutaneous scaphoid fixation using computer-assisted navigation with intraoperatively-acquired images. J Bone Joint Surg [B] 94(SUPP XXXVIII):52–52 Al-Sanawi H, Gammon B, Sellens RW, St John P, Smith EJ, Ellis RE, Pichora DR (2012) Percutaneous scaphoid fixation using computer-assisted navigation with intraoperatively-acquired images. J Bone Joint Surg [B] 94(SUPP XXXVIII):52–52
12.
go back to reference Jacob AL, Messmer P, Kaim A, Suhm N, Regazzoni P, Baumann B (2000) A whole-body registration-free navigation system for image-guided surgery and interventional radiology. Invest Radiol 35(5):279–288CrossRefPubMed Jacob AL, Messmer P, Kaim A, Suhm N, Regazzoni P, Baumann B (2000) A whole-body registration-free navigation system for image-guided surgery and interventional radiology. Invest Radiol 35(5):279–288CrossRefPubMed
13.
go back to reference Stelter K, Ledderose G, Hempel JM, Morhard DFB, Flatz W, Krause E, Mueller J (2012) Image guided navigation by intraoperative CT scan for cochlear implantation. Comput Aided Surg 17(3):153–160CrossRefPubMed Stelter K, Ledderose G, Hempel JM, Morhard DFB, Flatz W, Krause E, Mueller J (2012) Image guided navigation by intraoperative CT scan for cochlear implantation. Comput Aided Surg 17(3):153–160CrossRefPubMed
14.
go back to reference Belkova A (2013) Calibration of a mobile-gantry computed tomography scanner for surgical navigation. Master’s thesis, Queen’s University, Kingston Belkova A (2013) Calibration of a mobile-gantry computed tomography scanner for surgical navigation. Master’s thesis, Queen’s University, Kingston
15.
go back to reference Horn BKP (1987) Closed-form solution of absolute orientation using unit quaternions. J Optical Soc Am 4(4):629–642CrossRef Horn BKP (1987) Closed-form solution of absolute orientation using unit quaternions. J Optical Soc Am 4(4):629–642CrossRef
16.
go back to reference Besl PJ, McKay ND (1992) Method for registration of 3-D shapes. IEEE Pattern Anal Machine Intell 14(2):239–256CrossRef Besl PJ, McKay ND (1992) Method for registration of 3-D shapes. IEEE Pattern Anal Machine Intell 14(2):239–256CrossRef
Metadata
Title
Calibration of mobile-gantry computed tomography for surgical navigation
Authors
Anna Belkova
David R Pichora
Randy E Ellis
Publication date
01-04-2016
Publisher
Springer Berlin Heidelberg
Published in
International Journal of Computer Assisted Radiology and Surgery / Issue 4/2016
Print ISSN: 1861-6410
Electronic ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-015-1302-2

Other articles of this Issue 4/2016

International Journal of Computer Assisted Radiology and Surgery 4/2016 Go to the issue

Premium Partner