Skip to main content
Top
Published in: Journal of Coatings Technology and Research 4/2011

01-07-2011

Coatings applied on damp building substrates: performance and influence on moisture transport

Authors: Vânia Brito, Teresa Diaz Gonçalves, Paulina Faria

Published in: Journal of Coatings Technology and Research | Issue 4/2011

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Dampness is a common condition in old buildings and, accordingly, many paint systems specific for this type of building allow for application on walls with nonnegligible moisture content. In spite of that, performance evaluation of these paints is normally carried out using dry substrates or even on free paint films. This article presents research performed on 16 commercial paint systems: seven silicate, three silicone, three hydro-pliolite and two lime-based systems, as well as one common vinyl emulsion paint that served as reference. Each paint was applied and cured both on dry and on damp mortar substrates. The test specimens were subjected to water vapor permeability tests and evaporative drying tests. The following conclusions could be drawn: (i) the way paint systems influence the drying of the substrate, to which they were applied and where they cured, may vary significantly depending on the moisture content of that substrate; (ii) vapor permeability, measured with specimens applied and cured on dry substrate, may be an acceptable way of predicting a paint’s influence on drying, provided that the paints are applied and cured on dry substrate or that their characteristics are not significantly affected by the moisture content of that substrate.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference CEN, Paints and Varnishes. Coating Materials and Coating Systems for Exterior Masonry and Concrete. Part 1: Classification. EN 1062-1:2004 CEN, Paints and Varnishes. Coating Materials and Coating Systems for Exterior Masonry and Concrete. Part 1: Classification. EN 1062-1:2004
2.
go back to reference Hall, C, Hoff, WD, Water Transport in Brick, Stone and Concrete. Spon Press, London and New York, 2002CrossRef Hall, C, Hoff, WD, Water Transport in Brick, Stone and Concrete. Spon Press, London and New York, 2002CrossRef
3.
go back to reference Freitas, V, “Influence of the Vapour Permeability of Paintings and the Higroscopicity of the Internal Coating on the Hygrothermal Behaviour of Walls.” Proceedings of the CIB-W40 Meeting, Kyoto, Japan, pp. 256–269, October 7–10, 1997 Freitas, V, “Influence of the Vapour Permeability of Paintings and the Higroscopicity of the Internal Coating on the Hygrothermal Behaviour of Walls.” Proceedings of the CIB-W40 Meeting, Kyoto, Japan, pp. 256–269, October 7–10, 1997
4.
go back to reference Massari, G, Massari, I, Damp Buildings: Old and New. ICCROM, Rome, 1993 Massari, G, Massari, I, Damp Buildings: Old and New. ICCROM, Rome, 1993
5.
go back to reference I’Anson, SJ, Hoff, WD, “Water Movement in Porous Building Materials–VIII. Effects of Evaporative Drying on Height of Capillary Rise Equilibrium in Walls.” Build. Environ., 21 (3–4) 195–200 (1984) I’Anson, SJ, Hoff, WD, “Water Movement in Porous Building Materials–VIII. Effects of Evaporative Drying on Height of Capillary Rise Equilibrium in Walls.” Build. Environ., 21 (3–4) 195–200 (1984)
6.
go back to reference Gonçalves, TD, Pel, L, Rodrigues, JD, “Influence of Paints on Drying and Salt Distribution Processes in Porous Building Materials.” Constr. Build. Mater., 23 (5) 1751–1759 (2008)CrossRef Gonçalves, TD, Pel, L, Rodrigues, JD, “Influence of Paints on Drying and Salt Distribution Processes in Porous Building Materials.” Constr. Build. Mater., 23 (5) 1751–1759 (2008)CrossRef
7.
go back to reference Defreece, E, Sherry, N, Charola, AE, “Coatings on Brick Masonry: Are They Protective or Can They Enhance Deterioration?” JAIC, 46 39–52 (2007) Defreece, E, Sherry, N, Charola, AE, “Coatings on Brick Masonry: Are They Protective or Can They Enhance Deterioration?” JAIC, 46 39–52 (2007)
9.
go back to reference Hern, C, Snethlage, R, “Water Vapour Permeability of Painted Stone.” Proceedings of the 7th International Congress on Deterioration and Conservation of Stone, LNEC, Lisbon, pp. 677–686, June 15–18, 1992 Hern, C, Snethlage, R, “Water Vapour Permeability of Painted Stone.” Proceedings of the 7th International Congress on Deterioration and Conservation of Stone, LNEC, Lisbon, pp. 677–686, June 15–18, 1992
10.
go back to reference ISO, Paints and Varnishes—Determination of Water-Vapour Transmission Properties. Cup Method. ISO/DIS 7783 (2008) ISO, Paints and Varnishes—Determination of Water-Vapour Transmission Properties. Cup Method. ISO/DIS 7783 (2008)
11.
go back to reference RILEM TC 25-PEM, Test No. II.2, “Coefficient of Water Vapour Conductivity. Recommended Tests to Measure the Deterioration of Stone and to Assess the Effectiveness of Treatment Methods.” Mater. Struct., 13 197–199 (1980) RILEM TC 25-PEM, Test No. II.2, “Coefficient of Water Vapour Conductivity. Recommended Tests to Measure the Deterioration of Stone and to Assess the Effectiveness of Treatment Methods.” Mater. Struct., 13 197–199 (1980)
12.
go back to reference RILEM TC 25-PEM, Test No. II.5, “Evaporation Curve. Recommended Tests to Measure the Deterioration of Stone and to Assess the Effectiveness of Treatment Methods.” Mater. Struct., 13 204–207 (1980) RILEM TC 25-PEM, Test No. II.5, “Evaporation Curve. Recommended Tests to Measure the Deterioration of Stone and to Assess the Effectiveness of Treatment Methods.” Mater. Struct., 13 204–207 (1980)
13.
go back to reference Stoye, D, Freitag, W (eds.), Paints, Coatings and Solvents. Wiley-VCH, Weinheim, 1998 Stoye, D, Freitag, W (eds.), Paints, Coatings and Solvents. Wiley-VCH, Weinheim, 1998
14.
go back to reference Müller, B, Poth, U, Coatings Formulation: An International Textbook. Vincentz, Hannover, 2006 Müller, B, Poth, U, Coatings Formulation: An International Textbook. Vincentz, Hannover, 2006
17.
go back to reference Leitão, LA, Elementary Course on Construction (in Portuguese). Imprensa Nacional, Lisbon, 1896 Leitão, LA, Elementary Course on Construction (in Portuguese). Imprensa Nacional, Lisbon, 1896
18.
go back to reference Margalha, G, “The Use of Lime in Mortars in the Alentejo.” MSc Thesis (in Portuguese). Universidade de Évora, Évora (1997) Margalha, G, “The Use of Lime in Mortars in the Alentejo.” MSc Thesis (in Portuguese). Universidade de Évora, Évora (1997)
19.
go back to reference CEN, Methods of Testing Cement. Part 1: Determination of Strength. EN 196-1:2005 CEN, Methods of Testing Cement. Part 1: Determination of Strength. EN 196-1:2005
20.
go back to reference CEN, Methods of Test for Mortar for Masonry—Part 2: Bulk Sampling of Mortars and Preparation of Test Mortars. EN 1015-2:1998 CEN, Methods of Test for Mortar for Masonry—Part 2: Bulk Sampling of Mortars and Preparation of Test Mortars. EN 1015-2:1998
21.
go back to reference CEN, Methods of Test for Mortar for Masonry—Part 2: Bulk Sampling of Mortars and Preparation of Test Mortars. EN 1015-2:1998/A1:2006 CEN, Methods of Test for Mortar for Masonry—Part 2: Bulk Sampling of Mortars and Preparation of Test Mortars. EN 1015-2:1998/A1:2006
22.
go back to reference CEN, Methods of Test for Mortar for Masonry. Part 3: Determination of Consistence of Fresh Mortar (By Flow Table). EN 1015-3:1999 CEN, Methods of Test for Mortar for Masonry. Part 3: Determination of Consistence of Fresh Mortar (By Flow Table). EN 1015-3:1999
23.
go back to reference CEN, Methods of Test for Mortar for Masonry. Part 3: Determination of Consistence of Fresh Mortar (By Flow Table). EN 1015-3:1999/A1:2004 CEN, Methods of Test for Mortar for Masonry. Part 3: Determination of Consistence of Fresh Mortar (By Flow Table). EN 1015-3:1999/A1:2004
24.
go back to reference CEN, Methods of Test for Mortar for Masonry. Part 3: Determination of Consistence of Fresh Mortar (By Flow Table). EN 1015-3:1999/A2:2006 CEN, Methods of Test for Mortar for Masonry. Part 3: Determination of Consistence of Fresh Mortar (By Flow Table). EN 1015-3:1999/A2:2006
25.
go back to reference CEN, Methods of Test for Mortar for Masonry. Part 6: Determination of Bulk Density of Fresh Mortar. EN 1015-6:1998 CEN, Methods of Test for Mortar for Masonry. Part 6: Determination of Bulk Density of Fresh Mortar. EN 1015-6:1998
26.
go back to reference CEN, Methods of Test for Mortar for Masonry. Part 6: Determination of Bulk Density of Fresh Mortar. EN 1015-6:1998/A1:2006 CEN, Methods of Test for Mortar for Masonry. Part 6: Determination of Bulk Density of Fresh Mortar. EN 1015-6:1998/A1:2006
27.
go back to reference Teutonico, JM, A Laboratory Manual for Architectural Conservators. ICCROM, Rome, 1988 Teutonico, JM, A Laboratory Manual for Architectural Conservators. ICCROM, Rome, 1988
28.
go back to reference RILEM TC 25-PEM, Test No. II.6, “Water Absorption Coefficient (Capillarity). Recommended Tests to Measure the Deterioration of Stone and to Assess the Effectiveness of Treatment Methods.” Mater. Struct., 13 209–210 (1980) RILEM TC 25-PEM, Test No. II.6, “Water Absorption Coefficient (Capillarity). Recommended Tests to Measure the Deterioration of Stone and to Assess the Effectiveness of Treatment Methods.” Mater. Struct., 13 209–210 (1980)
29.
go back to reference Gonçalves, TD, Rodrigues, JD, Abreu, MM, Esteves, AM, Santos Silva, A, “Causes of Salt Decay and Repair of Plasters and Renders of Five Historic Buildings in Portugal.” Proceedings of the Conference Heritage, Weathering and Conservation, CSIC, Instituto de Geologia Económica, Madrid, Vol. 1, pp. 273–284, June 21–24, 2006 Gonçalves, TD, Rodrigues, JD, Abreu, MM, Esteves, AM, Santos Silva, A, “Causes of Salt Decay and Repair of Plasters and Renders of Five Historic Buildings in Portugal.” Proceedings of the Conference Heritage, Weathering and Conservation, CSIC, Instituto de Geologia Económica, Madrid, Vol. 1, pp. 273–284, June 21–24, 2006
30.
go back to reference CEN, Hygrothermal Performance of Building Materials and Products. Determination of Water Vapour Transmission Properties. EN ISO 12572:2001 CEN, Hygrothermal Performance of Building Materials and Products. Determination of Water Vapour Transmission Properties. EN ISO 12572:2001
31.
go back to reference Sherwood, TK, “The Drying of Solids II.” Ind. Eng. Chem., 21 (10) 976–980 (1929)CrossRef Sherwood, TK, “The Drying of Solids II.” Ind. Eng. Chem., 21 (10) 976–980 (1929)CrossRef
32.
go back to reference Hall, C, Hoff, WD, Nixon, MR, “Water Movement in Porous Building Materials—VI. Evaporation and Drying in Brick and Block Materials.” Build. Environ., 19 (1) 13–20 (1984)CrossRef Hall, C, Hoff, WD, Nixon, MR, “Water Movement in Porous Building Materials—VI. Evaporation and Drying in Brick and Block Materials.” Build. Environ., 19 (1) 13–20 (1984)CrossRef
33.
34.
go back to reference Commissione Normal, Misura dell’indice di asciugamento (drying index). CNR/ICR, Normal 29/88, Roma (1991) Commissione Normal, Misura dell’indice di asciugamento (drying index). CNR/ICR, Normal 29/88, Roma (1991)
35.
go back to reference Gossens, E, Van der Spoel, W, Bancken, E, “Moisture Transport in Coated Plaster.” Heron, 46 (3) 217–222 (2001) Gossens, E, Van der Spoel, W, Bancken, E, “Moisture Transport in Coated Plaster.” Heron, 46 (3) 217–222 (2001)
36.
go back to reference Tavares, M, “Conservation and Restoration of External Renderings of Old Buildings. A Methodology of Study and Repair.” PhD Thesis (in Portuguese). FA/UTL (2009) Tavares, M, “Conservation and Restoration of External Renderings of Old Buildings. A Methodology of Study and Repair.” PhD Thesis (in Portuguese). FA/UTL (2009)
38.
go back to reference Freitas, VP, Abrantes, V, Crausse, P, “Moisture Migration in Building Walls. Analysis of the Interface Phenomena.” Build. Environ., 31 (2) 99–108 (1996)CrossRef Freitas, VP, Abrantes, V, Crausse, P, “Moisture Migration in Building Walls. Analysis of the Interface Phenomena.” Build. Environ., 31 (2) 99–108 (1996)CrossRef
Metadata
Title
Coatings applied on damp building substrates: performance and influence on moisture transport
Authors
Vânia Brito
Teresa Diaz Gonçalves
Paulina Faria
Publication date
01-07-2011
Publisher
Springer US
Published in
Journal of Coatings Technology and Research / Issue 4/2011
Print ISSN: 1547-0091
Electronic ISSN: 1935-3804
DOI
https://doi.org/10.1007/s11998-010-9319-5

Other articles of this Issue 4/2011

Journal of Coatings Technology and Research 4/2011 Go to the issue

Premium Partners