Conformal mapping of carotid vessel wall and plaque thickness measured from 3D ultrasound images

Authors: Gary P. T. Choi, Yimin Chen, Lok Ming Lui, Bernard Chiu

Published in: Medical & Biological Engineering & Computing | Issue 12/2017

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Measurements of vessel-wall-plus-plaque thickness (VWT) from 3D carotid ultrasound have been shown to be sensitive to the effect of pharmaceutical interventions. Since the geometry of carotid arteries is highly subject-specific, quantitative comparison of the distributions of point-wise VWT measured for different patients or for the same patients at different ultrasound scanning sessions requires the development of a mapping strategy to adjust for the geometric variability of different carotid surface models. In this paper, we present an algorithm mapping each 3D carotid surface to a 2D carotid template with an emphasis on preserving the local geometry of the carotid surface by minimizing local angular distortion. The previously described arc-length scaling (AL) approach was applied to generate an initial 2D VWT map. Using results established in the quasi-conformal theory, a new map was computed to compensate for the angular distortion incurred in AL mapping. As the 2D carotid template lies on an L-shaped non-convex domain, one-to-one correspondence of the mapping operation was not guaranteed. To address this issue, an iterative Beltrami differential chopping and smoothing procedure was developed to enforce bijectivity. Evaluations performed in the 20 carotid surface models showed that the reduction in average angular distortion made by the proposed algorithm was highly significant (P = 2.06 × 10−5). This study is the first study showing that a bijective conformal map to a non-convex domain can be obtained using the iterative Beltrami differential chopping and smoothing procedure. The improved consistency exhibited in the 2D VWT map generated by the proposed algorithm will allow for unbiased quantitative comparisons of VWT as well as local geometric and hemodynamic quantities in population studies.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
2.
4.
6.
go back to reference Cheng J, Pike D, Chow TW, Kirby M, Parraga G, Chiu B (2016) Three-dimensional ultrasound measurements of carotid vessel wall and plaque thickness and their relationship with pulmonary abnormalities in ex-smokers without airflow limitation. Int J Cardiovasc Imaging 32(9):1391–1402CrossRefPubMed Cheng J, Pike D, Chow TW, Kirby M, Parraga G, Chiu B (2016) Three-dimensional ultrasound measurements of carotid vessel wall and plaque thickness and their relationship with pulmonary abnormalities in ex-smokers without airflow limitation. Int J Cardiovasc Imaging 32(9):1391–1402CrossRefPubMed
8.
go back to reference Chiu B, Chen W, Cheng J (2016) Concise biomarker for spatial-temporal change in three-dimensional ultrasound measurement of carotid vessel wall and plaque thickness based on a graph-based random walk framework: towards sensitive evaluation of response to therapy. Comput Biol Med 79:149–162CrossRefPubMed Chiu B, Chen W, Cheng J (2016) Concise biomarker for spatial-temporal change in three-dimensional ultrasound measurement of carotid vessel wall and plaque thickness based on a graph-based random walk framework: towards sensitive evaluation of response to therapy. Comput Biol Med 79:149–162CrossRefPubMed
9.
10.
go back to reference Chiu B, Li B, Chow TWS (2013) Novel 3d ultrasound image-based biomarkers based on a feature selection from a 2d standardized vessel wall thickness map: a tool for sensitive assessment of therapies for carotid atherosclerosis. Phys Med Biol 58(17):5959–5982. doi:10.1088/0031-9155/58/17/5959 CrossRefPubMed Chiu B, Li B, Chow TWS (2013) Novel 3d ultrasound image-based biomarkers based on a feature selection from a 2d standardized vessel wall thickness map: a tool for sensitive assessment of therapies for carotid atherosclerosis. Phys Med Biol 58(17):5959–5982. doi:10.​1088/​0031-9155/​58/​17/​5959 CrossRefPubMed
12.
13.
go back to reference Choi PT, Lam KC, Lui LM (2015) FLASH: fast landmark aligned spherical harmonic parameterization for genus-0 closed brain surfaces. SIAM J Imaging Sci 8(1):67–94. doi:10.1137/130950008 CrossRef Choi PT, Lam KC, Lui LM (2015) FLASH: fast landmark aligned spherical harmonic parameterization for genus-0 closed brain surfaces. SIAM J Imaging Sci 8(1):67–94. doi:10.​1137/​130950008 CrossRef
14.
go back to reference Choi PT, Lui LM (2015) Fast disk conformal parameterization of simply-connected open surfaces. J Sci Comput 65(3):1065–1090CrossRef Choi PT, Lui LM (2015) Fast disk conformal parameterization of simply-connected open surfaces. J Sci Comput 65(3):1065–1090CrossRef
16.
go back to reference Eicke BM, von Lorentz J, Paulus W (1995) Embolus detection in different degrees of carotid disease. Neurol Res 17(3):181–184CrossRefPubMed Eicke BM, von Lorentz J, Paulus W (1995) Embolus detection in different degrees of carotid disease. Neurol Res 17(3):181–184CrossRefPubMed
17.
18.
go back to reference Fenster A, Landry A, Downey DB, Hegele RA, Spence JD (2004) 3D ultrasound imaging of the carotid arteries. Curr Drug Targets Cardiovasc Haematol Disord 4(2):161–175CrossRefPubMed Fenster A, Landry A, Downey DB, Hegele RA, Spence JD (2004) 3D ultrasound imaging of the carotid arteries. Curr Drug Targets Cardiovasc Haematol Disord 4(2):161–175CrossRefPubMed
19.
go back to reference Filipovic N, Teng Z, Radovic M, Saveljic I, Fotiadis D, Parodi O (2013) Computer simulation of three-dimensional plaque formation and progression in the carotid artery. Med Biol Eng Comput 51(6):607–616. doi:10.1007/s11517-012-1031-4 CrossRefPubMed Filipovic N, Teng Z, Radovic M, Saveljic I, Fotiadis D, Parodi O (2013) Computer simulation of three-dimensional plaque formation and progression in the carotid artery. Med Biol Eng Comput 51(6):607–616. doi:10.​1007/​s11517-012-1031-4 CrossRefPubMed
20.
go back to reference Floater MS, Hormann K (2005) Surface parameterization: a tutorial and survey, pp. 157–186. Advances in multiresolution for geometric modelling. Springer-Verlag, Heidelberg Floater MS, Hormann K (2005) Surface parameterization: a tutorial and survey, pp. 157–186. Advances in multiresolution for geometric modelling. Springer-Verlag, Heidelberg
21.
go back to reference Haker S, Angenent S, Tannenbaum A, Kikinis R (2000) Nondistorting flattening maps and the 3-D visualization of colon CT images. IEEE Trans Med Imaging 19(7):665–670CrossRefPubMed Haker S, Angenent S, Tannenbaum A, Kikinis R (2000) Nondistorting flattening maps and the 3-D visualization of colon CT images. IEEE Trans Med Imaging 19(7):665–670CrossRefPubMed
22.
go back to reference He J, Gu D, Wu X, Reynolds K, Duan X, Yao C, Wang J, Chen CS, Chen J, Wildman RP, Klag MJ, Whelton PK (2005) Major causes of death among men and women in china. N Engl J Med 353(11):1124–1134. doi:10.1056/NEJMsa050467 CrossRefPubMed He J, Gu D, Wu X, Reynolds K, Duan X, Yao C, Wang J, Chen CS, Chen J, Wildman RP, Klag MJ, Whelton PK (2005) Major causes of death among men and women in china. N Engl J Med 353(11):1124–1134. doi:10.​1056/​NEJMsa050467 CrossRefPubMed
23.
go back to reference Krasinski A, Chiu B, Fenster A, Parraga G (2009) Magnetic resonance imaging and three-dimensional ultrasound of carotid atherosclerosis: mapping regional differences. J Magn Reson Imaging 29 (4):901–908. doi:10.1002/jmri.21709 CrossRefPubMed Krasinski A, Chiu B, Fenster A, Parraga G (2009) Magnetic resonance imaging and three-dimensional ultrasound of carotid atherosclerosis: mapping regional differences. J Magn Reson Imaging 29 (4):901–908. doi:10.​1002/​jmri.​21709 CrossRefPubMed
26.
go back to reference Landry A, Spence JD, Fenster A (2004) Measurement of carotid plaque volume by 3-dimensional ultrasound. Stroke 35(4):864–869CrossRefPubMed Landry A, Spence JD, Fenster A (2004) Measurement of carotid plaque volume by 3-dimensional ultrasound. Stroke 35(4):864–869CrossRefPubMed
31.
go back to reference Malek AM, Alper SL, Izumo S (1999) Hemodynamic shear stress and its role in atherosclerosis. JAMA 282(21):2035–2042CrossRefPubMed Malek AM, Alper SL, Izumo S (1999) Hemodynamic shear stress and its role in atherosclerosis. JAMA 282(21):2035–2042CrossRefPubMed
32.
go back to reference Meng TW, Choi GPT, Lui LM (2016) TEMPO: feature-endowed Teichmüller extremal mappings of point clouds. SIAM J Imaging Sci 9(4):1922–1962CrossRef Meng TW, Choi GPT, Lui LM (2016) TEMPO: feature-endowed Teichmüller extremal mappings of point clouds. SIAM J Imaging Sci 9(4):1922–1962CrossRef
33.
go back to reference Mozaffarian D, Benjamin EJ, Go AS, Arnett DK, Blaha MJ, Cushman M, de Ferranti S, Després JP, Fullerton HJ, Howard VJ, Huffman MD, Judd SE, Kissela BM, Lackland DT, Lichtman JH, Lisabeth LD, Liu S, Mackey RH, Matchar DB, McGuire DK, Mohler ER, Moy CS, Muntner P, Mussolino ME, Nasir K, Neumar RW, Nichol G, Palaniappan L, Pandey DK, Reeves MJ, Rodriguez CJ, Sorlie PD, Stein J, Towfighi A, Turan TN, Virani SS, Willey JZ, Woo D, Yeh RW, Turner MB (2014) Heart disease and stroke statistics - 2015 update. Circulation. doi:10.1161/CIR.0000000000000152 Mozaffarian D, Benjamin EJ, Go AS, Arnett DK, Blaha MJ, Cushman M, de Ferranti S, Després JP, Fullerton HJ, Howard VJ, Huffman MD, Judd SE, Kissela BM, Lackland DT, Lichtman JH, Lisabeth LD, Liu S, Mackey RH, Matchar DB, McGuire DK, Mohler ER, Moy CS, Muntner P, Mussolino ME, Nasir K, Neumar RW, Nichol G, Palaniappan L, Pandey DK, Reeves MJ, Rodriguez CJ, Sorlie PD, Stein J, Towfighi A, Turan TN, Virani SS, Willey JZ, Woo D, Yeh RW, Turner MB (2014) Heart disease and stroke statistics - 2015 update. Circulation. doi:10.​1161/​CIR.​0000000000000152​
34.
go back to reference Perktold K, Thurner E, Kenner T (1994) Flow and stress characteristics in rigid walled and compliant carotid artery bifurcation models. Medi Biol Eng Comput 32:19–26CrossRef Perktold K, Thurner E, Kenner T (1994) Flow and stress characteristics in rigid walled and compliant carotid artery bifurcation models. Medi Biol Eng Comput 32:19–26CrossRef
37.
38.
go back to reference Zeng W, Marino J, Gurijala KC, Gu X, Kaufman A (2010) Supine and prone colon registration using quasi-conformal mapping. IEEE Trans Vis Comput Graph 16(6):1348–1357CrossRefPubMedPubMedCentral Zeng W, Marino J, Gurijala KC, Gu X, Kaufman A (2010) Supine and prone colon registration using quasi-conformal mapping. IEEE Trans Vis Comput Graph 16(6):1348–1357CrossRefPubMedPubMedCentral
Metadata
Title
Conformal mapping of carotid vessel wall and plaque thickness measured from 3D ultrasound images
Authors
Gary P. T. Choi
Yimin Chen
Lok Ming Lui
Bernard Chiu
Publication date
07-06-2017
Publisher
Springer Berlin Heidelberg
Published in
Medical & Biological Engineering & Computing / Issue 12/2017
Print ISSN: 0140-0118
Electronic ISSN: 1741-0444
DOI
https://doi.org/10.1007/s11517-017-1656-4

Other articles of this Issue 12/2017

Medical & Biological Engineering & Computing 12/2017 Go to the issue

Premium Partner