Abstract

An analysis technique for the determination of rare-earth metals Ce, Er, Gd, La, Nd, Y in magnesium alloys by the method of atomic emission spectrometry with inductively coupled plasma is proposed. Analytical lines of elements free of significant spectral overlays and the internal standard line were chosen. The metrological characteristics of the technique were studied using model solutions and its accuracy was verified using standard samples of magnesium alloys containing rare-earth metals.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference E. N. Kablov, “Materials and chemical technologies for aeronautical engineering,” Vest. RAN, 82, No 6, 520–530 (2012). E. N. Kablov, “Materials and chemical technologies for aeronautical engineering,” Vest. RAN, 82, No 6, 520–530 (2012).
3.
go back to reference I. Yu. Mukhina, Z. P. Uridia, and N. V. Trofi mov, “Corrosion-resistant casting magnesium alloys,” Aviats. Mater. Tekhnol., 2, No. 47, 15–23 (2017). I. Yu. Mukhina, Z. P. Uridia, and N. V. Trofi mov, “Corrosion-resistant casting magnesium alloys,” Aviats. Mater. Tekhnol., 2, No. 47, 15–23 (2017).
5.
go back to reference E. N. Kablov, O. G. Ospennikova, and A. V. Vershkov, “Rare metals and rare earth elements –modern and future high-tech materials,” Aviats. Mater. Tekhnol., No. S2, 3–10 (2013). E. N. Kablov, O. G. Ospennikova, and A. V. Vershkov, “Rare metals and rare earth elements –modern and future high-tech materials,” Aviats. Mater. Tekhnol., No. S2, 3–10 (2013).
8.
go back to reference Yu. A. Karpov and V. B. Baranovskaya, “Analytical control – an integral part of material diagnostics,” Zavod. Lab. Diagn. Mater., 83, No. 1, Pt. I, 5–12 (2017). Yu. A. Karpov and V. B. Baranovskaya, “Analytical control – an integral part of material diagnostics,” Zavod. Lab. Diagn. Mater., 83, No. 1, Pt. I, 5–12 (2017).
9.
go back to reference V. G. Garanin, “The application of the spectrometer Grand-Epert to determine the composition of metals and alloys based on magnesium, titanium and aluminum,” Zavod. Lab. Diagn. Mater., 81, No 1, Pt. 2, 79–88 (2015). V. G. Garanin, “The application of the spectrometer Grand-Epert to determine the composition of metals and alloys based on magnesium, titanium and aluminum,” Zavod. Lab. Diagn. Mater., 81, No 1, Pt. 2, 79–88 (2015).
10.
go back to reference E. S. Koshel, V. B. Baranovskaya, and T. Yu. Gubanova, “Direct arc atomic emission analysis of yttrium, gadolinium, and neodymium oxides,” Zavod. Lab. Diagn. Mater., 81, No. 12, 8–13 (2015). E. S. Koshel, V. B. Baranovskaya, and T. Yu. Gubanova, “Direct arc atomic emission analysis of yttrium, gadolinium, and neodymium oxides,” Zavod. Lab. Diagn. Mater., 81, No. 12, 8–13 (2015).
11.
go back to reference E. F. Volkova, I. V. Mostyaev, and V. V. Akinina, “Comparative studies of the effect of phase composition on the mechanical and technological properties of magnesium alloys MA20- SP and MA2-1,” Trudy VIAM: Elektron. Nauch.-Tekhn. Zh., 1, No. 61, 41–48 (2018), DOI: https://doi.org/10.18577/2307-6046-2018-0-1-5-5. E. F. Volkova, I. V. Mostyaev, and V. V. Akinina, “Comparative studies of the effect of phase composition on the mechanical and technological properties of magnesium alloys MA20- SP and MA2-1,” Trudy VIAM: Elektron. Nauch.-Tekhn. Zh., 1, No. 61, 41–48 (2018), DOI: https://​doi.​org/​10.​18577/​2307-6046-2018-0-1-5-5.
13.
go back to reference K. U. Kainer, “Magnesium,” Magnesium Alloys and Their Applications: Proc. 6th Int. Conf., Wiley-VCH Verlag GmbH & Co. KGaA, Germany (2004), p. 987. K. U. Kainer, “Magnesium,” Magnesium Alloys and Their Applications: Proc. 6th Int. Conf., Wiley-VCH Verlag GmbH & Co. KGaA, Germany (2004), p. 987.
15.
go back to reference Yu. A. Karpov, Analytical Control of Metallurgical Production, Metallurgiya, Moscow (1995), pp. 97–107. Yu. A. Karpov, Analytical Control of Metallurgical Production, Metallurgiya, Moscow (1995), pp. 97–107.
16.
go back to reference N. Velitchkova, P. Petrova, S. Velichkov, and N. Daskalova, “Inductively coupled plasma optical emission spectrometry– determination of rare earth and platinum group of elements” Chemistry: Bulg. J. Sci. Educ., 24, No. 3, 469 (2015). N. Velitchkova, P. Petrova, S. Velichkov, and N. Daskalova, “Inductively coupled plasma optical emission spectrometry– determination of rare earth and platinum group of elements” Chemistry: Bulg. J. Sci. Educ., 24, No. 3, 469 (2015).
17.
go back to reference RMG 61–2010, GSI. Indicators of Accuracy, Correctness, Precision of Methods for Quantitative Chemical Analysis. Evaluation Methods. RMG 61–2010, GSI. Indicators of Accuracy, Correctness, Precision of Methods for Quantitative Chemical Analysis. Evaluation Methods.
18.
go back to reference E. N. Kablov, “Innovative developments of VIAM on the implementation of Strategic Directions for the Development of Materials and Technologies for Their Processing for the Period up to 2030,” Aviats. Mater. Tekhnol., 1, No. 34, 3–33 (2015). E. N. Kablov, “Innovative developments of VIAM on the implementation of Strategic Directions for the Development of Materials and Technologies for Their Processing for the Period up to 2030,” Aviats. Mater. Tekhnol., 1, No. 34, 3–33 (2015).
Metadata
Title
Determination of Rare-Earth Metals in Magnesium Alloys by Atomic Emission Spectrometry with Inductively Coupled Plasma
Authors
R. M. Dvoretskov
V. B. Baranovskaya
F. N. Karachevtsev
A. F. Letov
Publication date
14-08-2019
Publisher
Springer US
Published in
Measurement Techniques / Issue 4/2019
Print ISSN: 0543-1972
Electronic ISSN: 1573-8906
DOI
https://doi.org/10.1007/s11018-019-01632-y

Other articles of this Issue 4/2019

Measurement Techniques 4/2019 Go to the issue