Abstract

The National Institute for Occupational Safety and Health has developed and evaluated various fire barriers for their effectiveness in preventing the spraying of pressurized hydraulic fluids onto simulated turbocharger hot surfaces, and in preventing the ignition of flammable vapors and mists onto barrier outer surfaces. This initial study, however, needs to be followed by a larger investigation that deals with barrier effectiveness in preventing or reducing hydraulic fluid fires within compartments of operating equipment, and barrier physical endurance under hostile environments within compartments. Some of the barriers were also evaluated for their effectiveness in suppressing simulated turbocharger fast-developing fires (initial fires, 32 kW). For the evaluation, modeled engine compartments with simulated turbocharger surfaces of 600°C, initial fires of 32 kW, and a pressurized hydraulic fluid spray system, were used. Also, conceptualized designs of some of the fire barriers, set within the compartments of typical mining equipment, have been reported to provide further guidance toward barrier fabrication and installation. The fire barriers included a parachute silica cloth barrier lined with flexible stainless steel foil; a one-panel insulated stainless steel barrier with a water-spray system; a foldable multi-panel insulated stainless steel barrier; and, an open–close steel strip barrier. Results show that all four fire barriers were effective in preventing the spraying of pressurized hydraulic fluids onto simulated turbocharger hot surfaces. Most of the barriers were also effective in preventing the ignition of flammable vapors and mists onto barrier outer surfaces. Results also show that the parachute barrier and the one-panel barrier with a water-spray system were effective in suppressing simulated turbocharger initial fires of 32 kW.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Mine Safety and Health Administration (MSHA). Mine fire accident and injury abstracts, 1990–1999. U.S. Department of Labor, Office of Injury and Employment Information, Denver, CO Mine Safety and Health Administration (MSHA). Mine fire accident and injury abstracts, 1990–1999. U.S. Department of Labor, Office of Injury and Employment Information, Denver, CO
2.
go back to reference De Rosa MI (2004) Analyses of mobile equipment fires for all U.S. surface and underground coal and metal/nonmetal mining categories, 1990–1999. NIOSH IC 9467, 2004, 53 pp De Rosa MI (2004) Analyses of mobile equipment fires for all U.S. surface and underground coal and metal/nonmetal mining categories, 1990–1999. NIOSH IC 9467, 2004, 53 pp
3.
go back to reference De Rosa MI (2004) Analysis of mine fires for all U.S. underground and surface coal mining categories, 1990–1999. NIOSH IC 9470, 36 pp De Rosa MI (2004) Analysis of mine fires for all U.S. underground and surface coal mining categories, 1990–1999. NIOSH IC 9470, 36 pp
4.
go back to reference De Rosa MI. Analysis of mine fires for all U.S. metal/nonmetal mining categories, 1990–2001. NIOSH IC 9476, 52 pp De Rosa MI. Analysis of mine fires for all U.S. metal/nonmetal mining categories, 1990–2001. NIOSH IC 9476, 52 pp
5.
go back to reference MSHA. Accident and injury abstracts, 2000–2010. U.S. Department of Labor, Office of Injury and Employment Information, Denver, CO MSHA. Accident and injury abstracts, 2000–2010. U.S. Department of Labor, Office of Injury and Employment Information, Denver, CO
6.
go back to reference De Rosa MI (2007) Effectiveness of various inert gas concentrations for preventing and suppressing mining equipment cab fires: development of a dual cab fire inerting system. Fire Technol J 43(1):29–44CrossRef De Rosa MI (2007) Effectiveness of various inert gas concentrations for preventing and suppressing mining equipment cab fires: development of a dual cab fire inerting system. Fire Technol J 43(1):29–44CrossRef
8.
go back to reference Lambersten C (1994) Inergen: summary of relations. Physiological factors and fire protection engineering design scenario. Env. Biom. Res. Data Center, Inst. Env. Med., University of. Pennsylvania, College Park, PA, Report 4-14-94, pp 1–21 Lambersten C (1994) Inergen: summary of relations. Physiological factors and fire protection engineering design scenario. Env. Biom. Res. Data Center, Inst. Env. Med., University of. Pennsylvania, College Park, PA, Report 4-14-94, pp 1–21
9.
go back to reference Su J, Kim A, Crampton G, Liu Z (2001) Fire suppression with inert gas agents. Fire Prot Eng J 11:72–87CrossRef Su J, Kim A, Crampton G, Liu Z (2001) Fire suppression with inert gas agents. Fire Prot Eng J 11:72–87CrossRef
10.
go back to reference Guard G (1993) Development and testing of a lightweight fireproof composite structure. Proceedings of aerospace technology conference and exposition, Long Beach, CA, 3 pp Guard G (1993) Development and testing of a lightweight fireproof composite structure. Proceedings of aerospace technology conference and exposition, Long Beach, CA, 3 pp
11.
go back to reference Keith R, Dahms D, Litch R (1983) Versatile fire barrier systems for telephone cables. Proceedings of international wire and cable symposium, Cherry Hill, NJ, 9 pp Keith R, Dahms D, Litch R (1983) Versatile fire barrier systems for telephone cables. Proceedings of international wire and cable symposium, Cherry Hill, NJ, 9 pp
12.
go back to reference Leonard K (2003) Maximizing hot work safety with fabrics. Professional Safety J 40–43 Leonard K (2003) Maximizing hot work safety with fabrics. Professional Safety J 40–43
13.
go back to reference Yuan L (2006) Ignition of hydraulic fluid sprays by open flame and hot surfaces. J Loss Prev Process Ind 19:353–361.CrossRef Yuan L (2006) Ignition of hydraulic fluid sprays by open flame and hot surfaces. J Loss Prev Process Ind 19:353–361.CrossRef
14.
go back to reference Roberts A, Brookes F (1981) Hydraulic fluids: an approach to high pressure spray flammability testing based on measurement of heat output. Fire Mater J. 5:87–92CrossRef Roberts A, Brookes F (1981) Hydraulic fluids: an approach to high pressure spray flammability testing based on measurement of heat output. Fire Mater J. 5:87–92CrossRef
Metadata
Title
Development and Evaluation of Fire Barriers to Reduce Fire Hazards on large mining Equipment
Authors
Maria I. De Rosa
Charles D. Litton
Publication date
01-04-2013
Publisher
Springer US
Published in
Fire Technology / Issue 2/2013
Print ISSN: 0015-2684
Electronic ISSN: 1572-8099
DOI
https://doi.org/10.1007/s10694-012-0258-9

Other articles of this Issue 2/2013

Fire Technology 2/2013 Go to the issue