Conventionally dental crown manufacturing was done by investment casting. This work presents the Rapid Prototyping as a best tool for dental prosthesis and crown manufacturing. It also represents the static structural analysis of dental crown with FEM software, ANSYS 14.5. Crown Models are constructed with dental wings client software and mimics. FEM compatible models were constructed using Remeshing and Volume meshing tool of 3-matic software. Masticatory force 350 N was applied downward perpendicular to surface of molar crown with boundary conditions. Five materials such as Ti-6Al-4V, Stainless steel, Cobalt-Chromium, Zirconia and Titanium are selected for analysis. Zirconia and Cobalt-Chromium are found to be the best materials amongst the five. ANSYS results show that the optimum crown thickness ranges from 1.75 to 2.25 mm. Directional deformation is very less for the crown model developed with dental wings. Tooth preparation is the main parameter which affects the strength of crown 3D printing is the most promising tool for Dental Prosthesis manufacturing. It can be manufactured with selective laser sintering, ink-jet printing. This model is manufactured with Desktop CNC milling in Cobalt-Chromium metal.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Bammani SS, Birajdar PR, Metan SS (2012) Dental crown manufacturing using stereolithography method. In: Proceedings of international conference on advances in industrial and production engineering 2012 Bammani SS, Birajdar PR, Metan SS (2012) Dental crown manufacturing using stereolithography method. In: Proceedings of international conference on advances in industrial and production engineering 2012
2.
go back to reference Chougule VN, Mulay AV, Ahuja BB (2013) Three dimensional point cloud generations from CT scan images for bio-cad modeling. In: Proceedings international conference on additive manufacturing technologies—AM 2013 Chougule VN, Mulay AV, Ahuja BB (2013) Three dimensional point cloud generations from CT scan images for bio-cad modeling. In: Proceedings international conference on additive manufacturing technologies—AM 2013
3.
go back to reference Baradeswaran A, Joshua Selvakumar L, Padma Priya R (2014) Reconstruction of Images into 3D Models using CAD Techniques. European J Appl Eng Sci Res 3:1–8 Baradeswaran A, Joshua Selvakumar L, Padma Priya R (2014) Reconstruction of Images into 3D Models using CAD Techniques. European J Appl Eng Sci Res 3:1–8
4.
go back to reference Chromy A, Zalud L (2014) Robotic 3D scanner as an alternative to standard modalities of medical imaging. SpringerPlus a Springer Open J 3:1–10 Chromy A, Zalud L (2014) Robotic 3D scanner as an alternative to standard modalities of medical imaging. SpringerPlus a Springer Open J 3:1–10
5.
go back to reference Jin GQ, Li WD, Gao L, Popplewell K (2013) A hybrid and adaptive tool-path generation approach of rapid prototyping and manufacturing for biomedical models. Elsevier Comput Indus 64:336–349CrossRef Jin GQ, Li WD, Gao L, Popplewell K (2013) A hybrid and adaptive tool-path generation approach of rapid prototyping and manufacturing for biomedical models. Elsevier Comput Indus 64:336–349CrossRef
6.
go back to reference Gomes Ferraz E, Costa Safira Andrade L, Rode dos Santos A, Rabelo Torregrossa V, do Rosario Santos Freire M, Almeida Sarmento V (2011) Effect of different surface processing protocols in three-dimensional images for rapid prototyping. Elsevier Adv Eng Softw 42:332–335 Gomes Ferraz E, Costa Safira Andrade L, Rode dos Santos A, Rabelo Torregrossa V, do Rosario Santos Freire M, Almeida Sarmento V (2011) Effect of different surface processing protocols in three-dimensional images for rapid prototyping. Elsevier Adv Eng Softw 42:332–335
7.
go back to reference Wanga C-S, Wangb W-HA, Lin b M-C (2010) STL rapid prototyping bio-CAD model for CT medical image segmentation. Elsevier Comput 84 in Indus 61:187–197 Wanga C-S, Wangb W-HA, Lin b M-C (2010) STL rapid prototyping bio-CAD model for CT medical image segmentation. Elsevier Comput 84 in Indus 61:187–197
8.
go back to reference Lauwagie T, Vanhollebeke F, Pluymers B, Zegels4 R, Verschueren4 P, Dascotte1 E (2010) The impact of high-fidelity model geometry on test-analysis correlation and FE model updating results. In: Proceedings of ISMA 2010, pp 2679–2688 Lauwagie T, Vanhollebeke F, Pluymers B, Zegels4 R, Verschueren4 P, Dascotte1 E (2010) The impact of high-fidelity model geometry on test-analysis correlation and FE model updating results. In: Proceedings of ISMA 2010, pp 2679–2688
9.
go back to reference Singare S, Li Dichen L, Bingheng LY, Zhenyu G, Yaxiong L (2004) Design and fabrication of custom mandible titanium tray based on rapid prototyping. J Med Eng Phys 26:671–676CrossRef Singare S, Li Dichen L, Bingheng LY, Zhenyu G, Yaxiong L (2004) Design and fabrication of custom mandible titanium tray based on rapid prototyping. J Med Eng Phys 26:671–676CrossRef
10.
go back to reference Gebhardt A, Schmidt F-M, Hotter J-S, Sokalla W, Sokalla P (2010) Additive manufacturing by selective laser melting the realizer desktop machine and its application for the dental industry. J Phys Proc 5:543–549CrossRef Gebhardt A, Schmidt F-M, Hotter J-S, Sokalla W, Sokalla P (2010) Additive manufacturing by selective laser melting the realizer desktop machine and its application for the dental industry. J Phys Proc 5:543–549CrossRef
11.
go back to reference Bammani S, Birajdar P, Metan S (2013) Application of CAD and SLA method in dental prosthesis. AMAE Int J Manuf Mater Sci 3:14–18 Bammani S, Birajdar P, Metan S (2013) Application of CAD and SLA method in dental prosthesis. AMAE Int J Manuf Mater Sci 3:14–18
12.
go back to reference Varun Desai S, Venkateshkashyap KG, Thomas TO, Siddartha S, Ramesh CS (2013) Rapid prototyping of dental tool. In: Proceedings 3rd International Conference on Additive Manufacturing Technologies—AM 2013, Bangaluru Varun Desai S, Venkateshkashyap KG, Thomas TO, Siddartha S, Ramesh CS (2013) Rapid prototyping of dental tool. In: Proceedings 3rd International Conference on Additive Manufacturing Technologies—AM 2013, Bangaluru
13.
go back to reference Costa Safira L, Costa Bastos L, Estevao Beal V, Almeida de Azevedo R, Eduardo Francischone C, Almeida Sarmento V (2013) Accuracy of rapid prototyping biomodels plotted by three dimensional printing technique: ex vivo study. Adv Comput Tomogr 2:41–45 Costa Safira L, Costa Bastos L, Estevao Beal V, Almeida de Azevedo R, Eduardo Francischone C, Almeida Sarmento V (2013) Accuracy of rapid prototyping biomodels plotted by three dimensional printing technique: ex vivo study. Adv Comput Tomogr 2:41–45
15.
go back to reference Pan H, Li L, Tao J, Xurong X, Mao C, Gub X, Tang R (2008) Repair of enamel by using hydroxyapatite nano particles as the building blocks. J Mater Chem 18:4079–4084CrossRef Pan H, Li L, Tao J, Xurong X, Mao C, Gub X, Tang R (2008) Repair of enamel by using hydroxyapatite nano particles as the building blocks. J Mater Chem 18:4079–4084CrossRef
16.
go back to reference Ozcan M, H¨ammerle C (2012) Review-titanium as a reconstruction and implant material in dentistry: advantages and pitfalls. J Mater 5:1528–1545 Ozcan M, H¨ammerle C (2012) Review-titanium as a reconstruction and implant material in dentistry: advantages and pitfalls. J Mater 5:1528–1545
17.
go back to reference Malshe A, Bartolo P, Rajurkar K (2012) Biomedical production of implants by additive electro-chemical and physical processes. CIRP Ann Manuf Technol 61:635–655CrossRef Malshe A, Bartolo P, Rajurkar K (2012) Biomedical production of implants by additive electro-chemical and physical processes. CIRP Ann Manuf Technol 61:635–655CrossRef
18.
go back to reference Guti´errez Rubert SC, Meseguer Calas MD, Bellera Sosa J, Folguera Arbas, F.b (2013) Analysis of variability in the manufacture of Cr-Co fixed partial dentures by geometric comparison. Procedia 63:481–488 Guti´errez Rubert SC, Meseguer Calas MD, Bellera Sosa J, Folguera Arbas, F.b (2013) Analysis of variability in the manufacture of Cr-Co fixed partial dentures by geometric comparison. Procedia 63:481–488
19.
go back to reference Satoko T, Soshu K, Mitsuyori S, Taiji S (2011) Particle size effect and mechanical properties of alumina dental crown fabricated by stereolithogrphy. Trans JWRI, I 40:85–87 Satoko T, Soshu K, Mitsuyori S, Taiji S (2011) Particle size effect and mechanical properties of alumina dental crown fabricated by stereolithogrphy. Trans JWRI, I 40:85–87
20.
go back to reference Palamara JEA, Palamara D, Messer HH (2002) Strains in the marginal ridge during occlusal loading. Aust Dent J 47(3):218–222CrossRef Palamara JEA, Palamara D, Messer HH (2002) Strains in the marginal ridge during occlusal loading. Aust Dent J 47(3):218–222CrossRef
21.
go back to reference Milewski G (2005) Numerical and experimental analysis of effort of human tooth hard tissues in terms of proper occlusal loadings. Acta of Bioeng Biomech 7:47–59 Milewski G (2005) Numerical and experimental analysis of effort of human tooth hard tissues in terms of proper occlusal loadings. Acta of Bioeng Biomech 7:47–59
22.
go back to reference Raoofi S, Khademi Reza Amid M, Kadkhodazadeh M, Reza Movahhedi M (2013) Comparison of the effect of three abutment-implant connections on stress distribution at the internal surface of dental implants: a finite element analysis. J Dental Res Dental Clinics, Dental Prospects 7(3):132–133 Raoofi S, Khademi Reza Amid M, Kadkhodazadeh M, Reza Movahhedi M (2013) Comparison of the effect of three abutment-implant connections on stress distribution at the internal surface of dental implants: a finite element analysis. J Dental Res Dental Clinics, Dental Prospects 7(3):132–133
23.
go back to reference Uddanwadiker Rashmi (2012) Study of various molar crown designs and their assessment. J Biomed Sci Eng 5:629–633CrossRef Uddanwadiker Rashmi (2012) Study of various molar crown designs and their assessment. J Biomed Sci Eng 5:629–633CrossRef
24.
go back to reference Biswas BK, Bag S, Pal S (2013) Biomechanical analysis of normal and implanted tooth using biting force measurement. Int J Eng Appl Sci 4(2):17–23 Biswas BK, Bag S, Pal S (2013) Biomechanical analysis of normal and implanted tooth using biting force measurement. Int J Eng Appl Sci 4(2):17–23
25.
go back to reference Weisskircher HW (2013) Maximum bilateral masticatory forces in patients with and without pain. J Craniomandibular Function 5(1):19–39 Weisskircher HW (2013) Maximum bilateral masticatory forces in patients with and without pain. J Craniomandibular Function 5(1):19–39
Metadata
Title
Development and Optimization of Dental Crown Using Rapid Prototyping Integrated with CAD
Authors
P. J. Kale
R. M. Metkar
S. D. Hiwase
Copyright Year
2017
Publisher
Springer Singapore
DOI
https://doi.org/10.1007/978-981-10-0812-2_15

Premium Partners