Skip to main content
Top
Published in: Artificial Life and Robotics 4/2015

01-12-2015 | Original Article

Development of vibration sensing system with wide dynamic range: monitoring of scratching and turning-over motions during sleep

Authors: Yosuke Kurihara, Takashi Kaburagi, Kajiro Watanabe, Hiroshi Tanaka

Published in: Artificial Life and Robotics | Issue 4/2015

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

This paper describes a novel vibration sensing system with wide dynamic range for measuring “scratching”, “turning over” and “sitting up/lying down” motions in an unconstrained manner while the patient is sleeping. The sensing device used in the proposed system is composed of a piezoceramic sensor sandwiched between two metal plates. Under the system’s configuration, each piezoceramic sensor generates a measurable output voltage proportional to the wide-ranging amplitude of vibrations produced by “scratching”, “turning over” and “sitting up/lying down” motions. Furthermore, in order to detect the direction of “turning over” and “sitting up/lying down” motions, we defined two indices that could be calculated based on three output signals from the piezoceramic sensors placed under three legs of the bed. A validity experiment was carried out for comparison with a conventional sensing method for measuring “scratching”, “turning over” and “sitting up/lying down” motions. The results showed that the proposed vibration sensing system is valid in terms of accuracy without the need for attaching sensors to the patient’s body.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Ebata T, Aizawa H, Kamide R, Niimura M (1999) The characteristics of nocturnal scratching in adults with atopic dermatitis. Br J Dermatol 141:82–86CrossRef Ebata T, Aizawa H, Kamide R, Niimura M (1999) The characteristics of nocturnal scratching in adults with atopic dermatitis. Br J Dermatol 141:82–86CrossRef
2.
go back to reference Ebata T, Iwasaki S, Kamide R, Niimura M (2001) Use of a wrist activity monitor for the measurement of nocturnal scratching in patients with atopic dermatitis. Br J Dermatol 144:305–309CrossRef Ebata T, Iwasaki S, Kamide R, Niimura M (2001) Use of a wrist activity monitor for the measurement of nocturnal scratching in patients with atopic dermatitis. Br J Dermatol 144:305–309CrossRef
3.
go back to reference Izumi H, Ebata T, Sato Y, Aizawa H, Kamide R, Niimura M (1997) A simplified method for the measurement of nocturnal scratching with an infrared video camera. Skin 39:560–563 Izumi H, Ebata T, Sato Y, Aizawa H, Kamide R, Niimura M (1997) A simplified method for the measurement of nocturnal scratching with an infrared video camera. Skin 39:560–563
4.
go back to reference Umeda K, Noro Y, Murakami T, Tokime K, Sugisaki H, Yamanaka K, Kurokawa I, Kuno K, Tsutsui H, Nakanishi K, Mizutani H (2006) A novel acoustic evaluation system of scratching in mouse dermatitis: rapid and specific detection of invisibly rapid scratch in an atopic dermatitis model mouse. Life Sci 79:2144–2150CrossRef Umeda K, Noro Y, Murakami T, Tokime K, Sugisaki H, Yamanaka K, Kurokawa I, Kuno K, Tsutsui H, Nakanishi K, Mizutani H (2006) A novel acoustic evaluation system of scratching in mouse dermatitis: rapid and specific detection of invisibly rapid scratch in an atopic dermatitis model mouse. Life Sci 79:2144–2150CrossRef
5.
go back to reference Kawabe Y, Aritake K, Noro Y, Umeda K and Mizutani H (2007) A study of sensors for detection of human scratching behavior during sleep. Tokai of society related to electricity branch union rally, O-329 Kawabe Y, Aritake K, Noro Y, Umeda K and Mizutani H (2007) A study of sensors for detection of human scratching behavior during sleep. Tokai of society related to electricity branch union rally, O-329
6.
go back to reference Konishi M, Aritake K, Noro Y, Umeda K and Mizutani H (2008) A study of sensors for detection of human scratching behavior during sleep. Tokai of society related to electricity branch union rally, O-322 Konishi M, Aritake K, Noro Y, Umeda K and Mizutani H (2008) A study of sensors for detection of human scratching behavior during sleep. Tokai of society related to electricity branch union rally, O-322
7.
go back to reference Yokoi H, Noro Y, Umeda K and Mizutani H (2008) Detection of human scratching behavior during sleep with acceleration sensor. Tokai of society related to electricity branch union rally, O-323 Yokoi H, Noro Y, Umeda K and Mizutani H (2008) Detection of human scratching behavior during sleep with acceleration sensor. Tokai of society related to electricity branch union rally, O-323
8.
go back to reference Felix R, Shuster S (1975) A new method for the measurement of itch and the response to treatment. Br J Dermatol 93:303–312CrossRef Felix R, Shuster S (1975) A new method for the measurement of itch and the response to treatment. Br J Dermatol 93:303–312CrossRef
9.
go back to reference Savin AJ, Paterson DW, Oswald I (1973) Scratching during sleep. Lancet 302:296–297CrossRef Savin AJ, Paterson DW, Oswald I (1973) Scratching during sleep. Lancet 302:296–297CrossRef
10.
go back to reference Endo K, Sumitsuji H, Fukuzumi T, Adachi J, Aoki T (1997) Evaluation of scratch movements by a new scratch-monitor to analyze nocturnal itching in atopic dermatitis. Acta Derm Venereol (Stockh) 77:432–435 Endo K, Sumitsuji H, Fukuzumi T, Adachi J, Aoki T (1997) Evaluation of scratch movements by a new scratch-monitor to analyze nocturnal itching in atopic dermatitis. Acta Derm Venereol (Stockh) 77:432–435
11.
go back to reference Aoki T, Kushimoto H, Hishikawa Y, Savin AJ (1991) Nocturnal scratching and its relationship to the disturbed sleep of itchy subject. Clin Exp Dermatol 16:268–272CrossRef Aoki T, Kushimoto H, Hishikawa Y, Savin AJ (1991) Nocturnal scratching and its relationship to the disturbed sleep of itchy subject. Clin Exp Dermatol 16:268–272CrossRef
12.
go back to reference Alihan J, Vaahtornanta V (1979) A static charge sensitive bed. A new method for recording body movement during sleep. Electroencephalogr Clin Neurophysiol 46:731–734CrossRef Alihan J, Vaahtornanta V (1979) A static charge sensitive bed. A new method for recording body movement during sleep. Electroencephalogr Clin Neurophysiol 46:731–734CrossRef
13.
go back to reference Ishijima M (1993) Monitoring of electro-cardiograms in bed without utilizing body surface electrodes. IEEE Trans Biomed Eng 40(6):593–594CrossRef Ishijima M (1993) Monitoring of electro-cardiograms in bed without utilizing body surface electrodes. IEEE Trans Biomed Eng 40(6):593–594CrossRef
14.
go back to reference Hernandez L, Waag B, Hsiao H, Neelon V (1995) New non-invasive approach for monitoring respiratory movements of sleeping subjects. Physiol Meas 16(3):161–167CrossRef Hernandez L, Waag B, Hsiao H, Neelon V (1995) New non-invasive approach for monitoring respiratory movements of sleeping subjects. Physiol Meas 16(3):161–167CrossRef
15.
go back to reference Kirjavainen T, Cooper D, Polo O, Sullivan CE (1996) Respiratory and body movements as indicators of sleep stage and wakefulness in infants and young children. J Sleep Res 5(3):186–194CrossRef Kirjavainen T, Cooper D, Polo O, Sullivan CE (1996) Respiratory and body movements as indicators of sleep stage and wakefulness in infants and young children. J Sleep Res 5(3):186–194CrossRef
16.
go back to reference Rauhala E, Erkinjuntti M, Polo O (1996) Detection of periodic leg movements with a static-charge-sensitive bed. J Sleep Res 5(4):246–250CrossRef Rauhala E, Erkinjuntti M, Polo O (1996) Detection of periodic leg movements with a static-charge-sensitive bed. J Sleep Res 5(4):246–250CrossRef
17.
go back to reference Tanaka S, Matsumoto Y, Wakimoto K (2002) Unconstrained and noninvasive measurement of heart-beat and respiration periods using a phonocardiographic sensor. Med Biomed Eng Comput 40:246–252CrossRef Tanaka S, Matsumoto Y, Wakimoto K (2002) Unconstrained and noninvasive measurement of heart-beat and respiration periods using a phonocardiographic sensor. Med Biomed Eng Comput 40:246–252CrossRef
18.
go back to reference Watanabe K, Watanabe T, Watanabe H, Ando H, Ishikawa T, Kobayashi K (2005) Noninvasive measurement of heartbeat, respiration, snoring and body movements of a subject in bed via a pneumatic method. IEEE Trans Biomed Eng 52(12):2100–2107CrossRef Watanabe K, Watanabe T, Watanabe H, Ando H, Ishikawa T, Kobayashi K (2005) Noninvasive measurement of heartbeat, respiration, snoring and body movements of a subject in bed via a pneumatic method. IEEE Trans Biomed Eng 52(12):2100–2107CrossRef
19.
go back to reference Zhu X, Chen W, Nemoto T, Kanemitsu Y, Kitamura K, Yamakoshi K, Wei D (2006) Real-time monitoring of respiration rhythm and pulse rate during sleep. IEEE Trans Biomed Eng 53(12):2553–2563CrossRef Zhu X, Chen W, Nemoto T, Kanemitsu Y, Kitamura K, Yamakoshi K, Wei D (2006) Real-time monitoring of respiration rhythm and pulse rate during sleep. IEEE Trans Biomed Eng 53(12):2553–2563CrossRef
20.
go back to reference Brink M, Mueller CH, Schierz C (2006) Contact-free measurement of heart rate, respiration rate, and body movements during sleep. Behav Res Methods 38:511–521CrossRef Brink M, Mueller CH, Schierz C (2006) Contact-free measurement of heart rate, respiration rate, and body movements during sleep. Behav Res Methods 38:511–521CrossRef
21.
go back to reference Mack DC, Patrie JT, Suratt PM, Felder RA, Alwan MA (2009) Development and preliminary validation of heart rate and breathing rate detection using a passive, ballistocardiography-based sleep monitoring system. IEEE Trans Inf Technol Biomed 13(1):111–1120CrossRef Mack DC, Patrie JT, Suratt PM, Felder RA, Alwan MA (2009) Development and preliminary validation of heart rate and breathing rate detection using a passive, ballistocardiography-based sleep monitoring system. IEEE Trans Inf Technol Biomed 13(1):111–1120CrossRef
22.
go back to reference Watanabe K, Kurihara Y, Tanaka H (2009) Ubiquitous health monitoring at home -sensing of human bio-signals on flooring, on tatami mat, in the bathtub, and in the lavatory-. IEEE Sens J 9(12):1847–1855CrossRef Watanabe K, Kurihara Y, Tanaka H (2009) Ubiquitous health monitoring at home -sensing of human bio-signals on flooring, on tatami mat, in the bathtub, and in the lavatory-. IEEE Sens J 9(12):1847–1855CrossRef
23.
go back to reference Kortelainen JM, Mendez MO, Bianchi AM, Matteucci M, Cerutti S (2010) Sleep staging based on signals acquired through bed sensor. IEEE Trans Inf Technol Biomed 14(3):776–785CrossRef Kortelainen JM, Mendez MO, Bianchi AM, Matteucci M, Cerutti S (2010) Sleep staging based on signals acquired through bed sensor. IEEE Trans Inf Technol Biomed 14(3):776–785CrossRef
24.
go back to reference Nukaya S, Shino T, Kurihara Y, Watanabe K, Tanaka H (2012) Noninvasive bed sensing of human biosignals via piezoceramic devices sandwiched between the floor and bed. IEEE Sens J 12(3):431–438CrossRef Nukaya S, Shino T, Kurihara Y, Watanabe K, Tanaka H (2012) Noninvasive bed sensing of human biosignals via piezoceramic devices sandwiched between the floor and bed. IEEE Sens J 12(3):431–438CrossRef
25.
go back to reference Nukaya S, Sugie M, Kurihara Y, Hiroyasu T, Watanabe K, Tanaka H (2014) A noninvasive heartbeat, respiration and body movement monitoring system for neonates. Artif Life Robot 19(4):414–419CrossRef Nukaya S, Sugie M, Kurihara Y, Hiroyasu T, Watanabe K, Tanaka H (2014) A noninvasive heartbeat, respiration and body movement monitoring system for neonates. Artif Life Robot 19(4):414–419CrossRef
26.
go back to reference Sumi T, Nukaya S, Kaburagi T, Tanaka H, Watanabe K, Kurihara Y (2013) Development of scratching monitoring system based on mathematical model of unconstrained bed sensing method. Int J Med Health Biomed Pharm Eng 7(12):493–499 Sumi T, Nukaya S, Kaburagi T, Tanaka H, Watanabe K, Kurihara Y (2013) Development of scratching monitoring system based on mathematical model of unconstrained bed sensing method. Int J Med Health Biomed Pharm Eng 7(12):493–499
27.
go back to reference Kurihara Y, Kaburagi T, Watanabe K (2013) Development of a non-contact sensing method for scratching activity measurement. IEEE Sens J 13(9):3325–3330CrossRef Kurihara Y, Kaburagi T, Watanabe K (2013) Development of a non-contact sensing method for scratching activity measurement. IEEE Sens J 13(9):3325–3330CrossRef
Metadata
Title
Development of vibration sensing system with wide dynamic range: monitoring of scratching and turning-over motions during sleep
Authors
Yosuke Kurihara
Takashi Kaburagi
Kajiro Watanabe
Hiroshi Tanaka
Publication date
01-12-2015
Publisher
Springer Japan
Published in
Artificial Life and Robotics / Issue 4/2015
Print ISSN: 1433-5298
Electronic ISSN: 1614-7456
DOI
https://doi.org/10.1007/s10015-015-0241-x

Other articles of this Issue 4/2015

Artificial Life and Robotics 4/2015 Go to the issue