Skip to main content
Top
Published in: Medical & Biological Engineering & Computing 6/2008

01-06-2008 | Original Article

Diameter measurement from images of fluorescent cylinders embedded in tissue

Authors: Marijn P. Rolf, Rene ter Wee, Ton G. van Leeuwen, Jos A. E. Spaan, Geert J. Streekstra

Published in: Medical & Biological Engineering & Computing | Issue 6/2008

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Absorption and scattering of light by tissue as well as limitations in the resolution of the optical system influence the appearance of tissue embedded objects in fluorescence images and may reduce the accuracy of measurements from these images. Although the principles of light scattering in tissue and optical resolution are well known, the interplay between the two in fluorescence imaging in an imaging cryomicrotome is not well understood. In this paper we present and investigate an image formation model in a reflection geometry, like an imaging cryomicrotome, that takes both light scattering by tissue as well as the point spread function of the lens into account. The validity of the model was investigated by comparison of diameter estimates of fluorescent cylinders as obtained from images acquired in a reflection geometry with those estimated from simulated images. The results reveal that diameter values estimated from the simulated images are in excellent agreement with the experimental estimates. Our approach in modeling the image formation process of embedded fluorescent structures allows for the prediction of accuracy of quantitative estimates from fluorescence images. The relationship between imaging parameters and bias can be applied to arrive at accurate diameter estimates of near cylindrical structures like blood vessels.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Bernard SL, Ewen JR, Barlow CH, Kelly JJ, McKinney S, Frazer DA, Glenny RW (2006) High spatial resolution measurements of organ blood flow in small laboratory animals. Am J Physiol Heart Circulat Physiol 279:H2043–H2052 Bernard SL, Ewen JR, Barlow CH, Kelly JJ, McKinney S, Frazer DA, Glenny RW (2006) High spatial resolution measurements of organ blood flow in small laboratory animals. Am J Physiol Heart Circulat Physiol 279:H2043–H2052
2.
go back to reference Born M, Wolf E (1980) Principles of optics. Academic Press, San Diego Born M, Wolf E (1980) Principles of optics. Academic Press, San Diego
3.
go back to reference Eidsath A, Chernomordik V, Gandjbakhche A, Smith P, Russo A (2002) Three-dimensional localization of fluorescent masses deeply embedded in tissue. Phys Med Biol 47(22):4079–4092CrossRef Eidsath A, Chernomordik V, Gandjbakhche A, Smith P, Russo A (2002) Three-dimensional localization of fluorescent masses deeply embedded in tissue. Phys Med Biol 47(22):4079–4092CrossRef
4.
go back to reference Faber DJ, van der Meer FJ, Aalders MC, van Leeuwen TG (2004) Quantitative measurement of attenuation coefficients of weakly scattering media using optical coherence tomography. Opt Express 12:4353–4365CrossRef Faber DJ, van der Meer FJ, Aalders MC, van Leeuwen TG (2004) Quantitative measurement of attenuation coefficients of weakly scattering media using optical coherence tomography. Opt Express 12:4353–4365CrossRef
5.
go back to reference Kelly JJ, Ewen JR, Bernard SL, Glenny RW, Barlow CH (2000) Regional blood flow measurements from fluorescent microsphere images using an imaging cryomicrotome. Rev Sci Instrum 71(1):228–234CrossRef Kelly JJ, Ewen JR, Bernard SL, Glenny RW, Barlow CH (2000) Regional blood flow measurements from fluorescent microsphere images using an imaging cryomicrotome. Rev Sci Instrum 71(1):228–234CrossRef
6.
go back to reference van Leeuwen TG, Faber DJ, Aalders MC (2003) Measurement of the axial point spread function in scattering media using single mode fiber based optical coherence tomography. IEEE J Sel Top Quant Electr 9:227–233CrossRef van Leeuwen TG, Faber DJ, Aalders MC (2003) Measurement of the axial point spread function in scattering media using single mode fiber based optical coherence tomography. IEEE J Sel Top Quant Electr 9:227–233CrossRef
7.
go back to reference Massoud TF, Gambhir SS (2003) Molecular imaging in living subjects: seeing fundamental biological processes in a new light. Genes Dev 17(5):545–580CrossRef Massoud TF, Gambhir SS (2003) Molecular imaging in living subjects: seeing fundamental biological processes in a new light. Genes Dev 17(5):545–580CrossRef
8.
go back to reference Press WH, Teukolsky SA, Vetterling WT, Flannery BP (1992) Numerical recipes in C. Cambridge University Press, New YorkMATH Press WH, Teukolsky SA, Vetterling WT, Flannery BP (1992) Numerical recipes in C. Cambridge University Press, New YorkMATH
9.
go back to reference Shimizu K, Tochio K, Kato Y (2005) Improvement of transcutaneous fluorescent images with a depth dependent point-spread function. Appl Opt 44(11):2154–2161CrossRef Shimizu K, Tochio K, Kato Y (2005) Improvement of transcutaneous fluorescent images with a depth dependent point-spread function. Appl Opt 44(11):2154–2161CrossRef
10.
go back to reference Spaan JAE, ter Wee R, van Teeffelen JWGE, Streekstra G, Siebes M, Kolyva C, Vink H, Fokkema DS, VanBavel E (2005) Visualisation of intromural coronary vasculature by an imaging cryomicrotome suggests compartmentalisation of myocardial perfusion areas. Med Biol Eng Comput 43(4):431–435CrossRef Spaan JAE, ter Wee R, van Teeffelen JWGE, Streekstra G, Siebes M, Kolyva C, Vink H, Fokkema DS, VanBavel E (2005) Visualisation of intromural coronary vasculature by an imaging cryomicrotome suggests compartmentalisation of myocardial perfusion areas. Med Biol Eng Comput 43(4):431–435CrossRef
11.
go back to reference Streekstra GJ, van Pelt J (2002) Analysis of tubular structures in three-dimensional confocal images. Netw Comput Neural Syst 13(3):381–395CrossRef Streekstra GJ, van Pelt J (2002) Analysis of tubular structures in three-dimensional confocal images. Netw Comput Neural Syst 13(3):381–395CrossRef
12.
go back to reference Streekstra GJ, van den Boomgaard R, Smeulders AWM (2001) Scale dependency of image derivatives for feature measurement in curvilinear structures. Int J Comp Vis 42(3):177–189MATHCrossRef Streekstra GJ, van den Boomgaard R, Smeulders AWM (2001) Scale dependency of image derivatives for feature measurement in curvilinear structures. Int J Comp Vis 42(3):177–189MATHCrossRef
13.
go back to reference Streekstra GJ, Brascamp P, van der Leij C, ter Wee R, Strackee SD, Maas M, Venema HW (2004) Cartilage thickness measurement in the sub-millimeter range. Lect Notes Comp Sci 3217(2):950–958CrossRef Streekstra GJ, Brascamp P, van der Leij C, ter Wee R, Strackee SD, Maas M, Venema HW (2004) Cartilage thickness measurement in the sub-millimeter range. Lect Notes Comp Sci 3217(2):950–958CrossRef
14.
go back to reference van Vliet L, Verbeek P (1994) Edge localization by mog filters: Multiple-of-gaussians. Pattern Recognit Lett 15:485–496MATHCrossRef van Vliet L, Verbeek P (1994) Edge localization by mog filters: Multiple-of-gaussians. Pattern Recognit Lett 15:485–496MATHCrossRef
Metadata
Title
Diameter measurement from images of fluorescent cylinders embedded in tissue
Authors
Marijn P. Rolf
Rene ter Wee
Ton G. van Leeuwen
Jos A. E. Spaan
Geert J. Streekstra
Publication date
01-06-2008
Publisher
Springer-Verlag
Published in
Medical & Biological Engineering & Computing / Issue 6/2008
Print ISSN: 0140-0118
Electronic ISSN: 1741-0444
DOI
https://doi.org/10.1007/s11517-008-0328-9

Other articles of this Issue 6/2008

Medical & Biological Engineering & Computing 6/2008 Go to the issue

Premium Partner