Recently, scanning electron microscopy (SEM) has been used for digital image correlation (DIC), as micrographs can be acquired with high magnification, providing improved resolution to quantify strain heterogeneities. However, it has been shown by researchers that SEM images can be problematic due to inherent electromagnetic distortions that are not present in optical images. Drift, spatial distortions, and magnification uncertainties are the main issues that can seriously affect the accuracy of localized strain measurements. The present work focuses on long duration experiments, for which images are taken days or weeks apart. We have proposed a systematic procedure to reduce drift, correct spatial distortion, and account for magnification variations between pairs of acquired images. Additionally, SEM parameters are discussed and chosen to increase the signal-to-noise ratio and improve the accuracy of the DIC measurements. The spatial distortion correction increases the repeatability of the correlated values and the precision of the measurements. The implementation for this type of correction is done by applying the measured distortion gradient of a certified grid onto the DIC strain field. The magnification adjustment increases the reliability of the strain maps, ensuring the measurements are in agreement with the actual strain induced during the experiment. We have presented a systematic protocol for ex-situ DIC experiments within the SEM and some basic cross-check procedures that can be performed to evaluate the reliability of the reference grid and the precision of the final strain map.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Appendix
Available only for authorised users
Literature
2.
go back to reference Abuzaid WZ, Sangid MD, Carroll JD, Sehitoglu H, Lambros J (2012) Slip transfer and plastic strain accumulation across grain boundaries in Hastelloy X. J Mech Phys Solids 60(6):1201–1220CrossRef Abuzaid WZ, Sangid MD, Carroll JD, Sehitoglu H, Lambros J (2012) Slip transfer and plastic strain accumulation across grain boundaries in Hastelloy X. J Mech Phys Solids 60(6):1201–1220CrossRef
3.
go back to reference Tschopp MA, Bartha BB, Porter WJ, Murray PT, Fairchild SB (2009) Microstructure-Dependent Local Strain Behavior in Polycrystals through In-Situ Scanning Electron Microscope Tensile Experiments. Metall Mater Trans A: Phys Metall Mater Sci 40(10):2363–2368. doi:10.1007/s11661-009-9938-6 CrossRef Tschopp MA, Bartha BB, Porter WJ, Murray PT, Fairchild SB (2009) Microstructure-Dependent Local Strain Behavior in Polycrystals through In-Situ Scanning Electron Microscope Tensile Experiments. Metall Mater Trans A: Phys Metall Mater Sci 40(10):2363–2368. doi:10.​1007/​s11661-009-9938-6 CrossRef
4.
go back to reference Carter JLW, Zhou N, Sosa JM, Shade PA, Pilchak AL, Kuper WM, Wang Y, Fraser HL, Uchic MD, Mills MJ (2012) Characterization of strain accumulation at grain boundaries of nickel based superalloys. Superalloys 2012: 12th International Symposium on Superalloys (TMS), pp 43–52. doi:10.1002/9781118516430.ch5 Carter JLW, Zhou N, Sosa JM, Shade PA, Pilchak AL, Kuper WM, Wang Y, Fraser HL, Uchic MD, Mills MJ (2012) Characterization of strain accumulation at grain boundaries of nickel based superalloys. Superalloys 2012: 12th International Symposium on Superalloys (TMS), pp 43–52. doi:10.​1002/​9781118516430.​ch5
6.
go back to reference Esquivel J, Sangid MD (2015) Digital Image Correlation of Heterogeneous Deformation in Polycrystalline Material with Electron Backscatter Diffraction. Microsc. Microanal. 21 (Suppl 3), 21 (0583): 1167–68. doi:10.1017/S1431927615006625 Esquivel J, Sangid MD (2015) Digital Image Correlation of Heterogeneous Deformation in Polycrystalline Material with Electron Backscatter Diffraction. Microsc. Microanal. 21 (Suppl 3), 21 (0583): 1167–68. doi:10.​1017/​S143192761500662​5
7.
go back to reference Kammers A, Daly S (2011) Experimental investigation of deformation mechanisms present in ultrafine-grained metals. In: Proulx T (ed) MEMS and nanotechnology, Volume 44. Conference Proceedings of the Society for Experimental Mechanics Series. Springer, New York, pp 105–10. doi:10.1007/978-1-4614-0210-7 Kammers A, Daly S (2011) Experimental investigation of deformation mechanisms present in ultrafine-grained metals. In: Proulx T (ed) MEMS and nanotechnology, Volume 44. Conference Proceedings of the Society for Experimental Mechanics Series. Springer, New York, pp 105–10. doi:10.​1007/​978-1-4614-0210-7
8.
go back to reference Sutton MA, Li N, Garcia D, Cornille N, Orteu JJ, McNeill SR, Schreier HW, Li X, Reynolds AP (2007) Scanning Electron Microscopy for Quantitative Small and Large Deformation Measurements Part II: Experimental Validation for Magnifications from 200 to 10,000. Exp Mech 47(6):789–804. doi:10.1007/s11340-007-9041-0 CrossRef Sutton MA, Li N, Garcia D, Cornille N, Orteu JJ, McNeill SR, Schreier HW, Li X, Reynolds AP (2007) Scanning Electron Microscopy for Quantitative Small and Large Deformation Measurements Part II: Experimental Validation for Magnifications from 200 to 10,000. Exp Mech 47(6):789–804. doi:10.​1007/​s11340-007-9041-0 CrossRef
9.
go back to reference Sutton MA, Li N, Joy DC, Reynolds AP, Li X (2007) Scanning Electron Microscopy for Quantitative Small and Large Deformation Measurements Part I: SEM Imaging at Magnifications from 200 to 10,000. Exp Mech 47(6):775–787. doi:10.1007/s11340-007-9042-z CrossRef Sutton MA, Li N, Joy DC, Reynolds AP, Li X (2007) Scanning Electron Microscopy for Quantitative Small and Large Deformation Measurements Part I: SEM Imaging at Magnifications from 200 to 10,000. Exp Mech 47(6):775–787. doi:10.​1007/​s11340-007-9042-z CrossRef
10.
go back to reference Sutton MA, Li N, Garcia D, Cornille N, Orteu JJ, McNeill SR, Schreier HW, Li X (2006) Metrology in a Scanning Electron Microscope: Theoretical Developments and Experimental Validation. Meas Sci Technol 17(10):2613. doi:10.1088/0957-0233/17/10/012 CrossRef Sutton MA, Li N, Garcia D, Cornille N, Orteu JJ, McNeill SR, Schreier HW, Li X (2006) Metrology in a Scanning Electron Microscope: Theoretical Developments and Experimental Validation. Meas Sci Technol 17(10):2613. doi:10.​1088/​0957-0233/​17/​10/​012 CrossRef
12.
go back to reference Kammers AD, Daly S (2013) Self-Assembled Nanoparticle Surface Patterning for Improved Digital Image Correlation in a Scanning Electron Microscope. Experimental Mechanics, 1–15. doi:10.1007/s11340-013-9734-5. Kammers AD, Daly S (2013) Self-Assembled Nanoparticle Surface Patterning for Improved Digital Image Correlation in a Scanning Electron Microscope. Experimental Mechanics, 1–15. doi:10.​1007/​s11340-013-9734-5.
13.
go back to reference Kammers AD, Daly S (2013) Digital image correlation under scanning electron microscopy: methodology and validation. Exp Mech 53.9:1743–1761CrossRef Kammers AD, Daly S (2013) Digital image correlation under scanning electron microscopy: methodology and validation. Exp Mech 53.9:1743–1761CrossRef
16.
go back to reference Tortonese M, Guan Y, Prochazka J (2003) NIST-traceable calibration of CD-SEM magnification using a 100-nm pitch standard. Proc SPIE - Int Soc Opt Eng 5038:711–718. doi:10.1117/12.482648 Tortonese M, Guan Y, Prochazka J (2003) NIST-traceable calibration of CD-SEM magnification using a 100-nm pitch standard. Proc SPIE - Int Soc Opt Eng 5038:711–718. doi:10.​1117/​12.​482648
17.
go back to reference Vladar AE (1999) Time-Lapse Scanning Electron Microscopy for Measurement of Contamination Rate and Stage Drift. Scanning 21:191–196CrossRef Vladar AE (1999) Time-Lapse Scanning Electron Microscopy for Measurement of Contamination Rate and Stage Drift. Scanning 21:191–196CrossRef
18.
go back to reference Stinville JC, Echlin MP, Texier D, Bridier F, Bocher P, Pollock TM (2016) Sub-Grain Scale Digital Image Correlation by Electron Microscopy for Polycrystalline Materials during Elastic and Plastic Deformation. Exp Mech 56(2):197–216. doi:10.1007/s11340-015-0083-4 CrossRef Stinville JC, Echlin MP, Texier D, Bridier F, Bocher P, Pollock TM (2016) Sub-Grain Scale Digital Image Correlation by Electron Microscopy for Polycrystalline Materials during Elastic and Plastic Deformation. Exp Mech 56(2):197–216. doi:10.​1007/​s11340-015-0083-4 CrossRef
19.
go back to reference Marschallinger R, Topa D (1997) Assessment and Correction of Geometric Distortions in Low-Magnification Scanning Electron Microscopy Images. Scanning 19:36–41 Marschallinger R, Topa D (1997) Assessment and Correction of Geometric Distortions in Low-Magnification Scanning Electron Microscopy Images. Scanning 19:36–41
20.
go back to reference Charbal A, Dufour J-E, Guery A, Hild F, Roux S, Vincent L, Poncelet M (2016) Integrated Digital Image Correlation considering gray level and blur variations: Application to distortion measurements of IR camera. Opt Lasers Eng 78:75–85. doi:10.1016/j.optlaseng.2015.09.011 CrossRef Charbal A, Dufour J-E, Guery A, Hild F, Roux S, Vincent L, Poncelet M (2016) Integrated Digital Image Correlation considering gray level and blur variations: Application to distortion measurements of IR camera. Opt Lasers Eng 78:75–85. doi:10.​1016/​j.​optlaseng.​2015.​09.​011 CrossRef
21.
go back to reference Watt IM (1997) The Principles and Practice of Electron Microscopy. Chapter 5. 189-200. Second Edition. Cambridge University Press. ISBN 0 521 43591 9. New York Watt IM (1997) The Principles and Practice of Electron Microscopy. Chapter 5. 189-200. Second Edition. Cambridge University Press. ISBN 0 521 43591 9. New York
Metadata
Title
Distortion Correction Protocol for Digital Image Correlation after Scanning Electron Microscopy: Emphasis on Long Duration and Ex-Situ Experiments
Authors
A. W. Mello
T. A. Book
A. Nicolas
S. E. Otto
C. J. Gilpin
M. D. Sangid
Publication date
13-07-2017
Publisher
Springer US
Published in
Experimental Mechanics / Issue 9/2017
Print ISSN: 0014-4851
Electronic ISSN: 1741-2765
DOI
https://doi.org/10.1007/s11340-017-0303-1

Other articles of this Issue 9/2017

Experimental Mechanics 9/2017 Go to the issue

Premium Partners