Experimental Study on Electrical Power Generation and Natural Daylighting Illuminance Due to Building-Applied Photovoltaic Façade Application

Authors : Ahmad Riaz, Jili Zhang, Chao Zhou, Ruobing Liang

Published in: Proceedings of the 11th International Symposium on Heating, Ventilation and Air Conditioning (ISHVAC 2019)

Publisher: Springer Singapore

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Office buildings consume a huge amount of energy which is responsible for greenhouse gas emissions as well. On the other hand, the photovoltaic systems play a copious role in building energy load reduction and at the same time supply clean electrical energy to the building. In this study, south-facing applied photovoltaics system was built to the exterior of the existing office building with a 0.5 m air gap having 13 m × 4 m dimensions with 8 × 4 of array layout to form building-applied photovoltaic (BAPV). The thermal response of this BAPV system was studied under real outdoor conditions for Dalian. Moreover, the daylighting illuminance (lux) was measured at the working plane inside the office room due to the effect of BAPV façade construction. The 19.8% of power generation efficiency was found for such custom-made PV modules. In addition, the daylighting illuminance was found to be 300–500 lx till 14:30 and afterward led to decrease and have to switch on the artificial daylighting for indoor comfort.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Song, J.-H., Lim, J.-H., Song, S.-Y.: Evaluation of alternatives for reducing thermal bridges in metal panel curtain wall systems. Energy Build. 127, 138–158 (2016)CrossRef Song, J.-H., Lim, J.-H., Song, S.-Y.: Evaluation of alternatives for reducing thermal bridges in metal panel curtain wall systems. Energy Build. 127, 138–158 (2016)CrossRef
2.
go back to reference Goossens, D., Goverde, H., Catthoor, F.: Effect of wind on temperature patterns, electrical characteristics, and performance of building-integrated and building-applied inclined photovoltaic modules. Sol. Energy 170, 64–75 (2018)CrossRef Goossens, D., Goverde, H., Catthoor, F.: Effect of wind on temperature patterns, electrical characteristics, and performance of building-integrated and building-applied inclined photovoltaic modules. Sol. Energy 170, 64–75 (2018)CrossRef
3.
go back to reference Agathokleous, R.A., Kalogirou, S.A.: Part I: thermal analysis of naturally ventilated BIPV system: experimental investigation and convective heat transfer coefficients estimation. Sol. Energy (2018) Agathokleous, R.A., Kalogirou, S.A.: Part I: thermal analysis of naturally ventilated BIPV system: experimental investigation and convective heat transfer coefficients estimation. Sol. Energy (2018)
4.
go back to reference Yang, T., Athienitis, A.K.: A review of research and developments of building-integrated photovoltaic/thermal (BIPV/T) systems. Renew. Sust. Energy Rev 66, 886–912 (2016)CrossRef Yang, T., Athienitis, A.K.: A review of research and developments of building-integrated photovoltaic/thermal (BIPV/T) systems. Renew. Sust. Energy Rev 66, 886–912 (2016)CrossRef
5.
go back to reference Tiwari, A., Sodha, M.S., Chandra, A., Joshi, J.C.: Performance evaluation of photovoltaic thermal solar air collector for composite climate of India. Sol. Energy Mater. Sol. Cells 90(2), 175–189 (2006)CrossRef Tiwari, A., Sodha, M.S., Chandra, A., Joshi, J.C.: Performance evaluation of photovoltaic thermal solar air collector for composite climate of India. Sol. Energy Mater. Sol. Cells 90(2), 175–189 (2006)CrossRef
6.
go back to reference Joshi, A.S., Tiwari, A., Tiwari, G.N., Dincer, I., Reddy, B.V.: Performance evaluation of a hybrid photovoltaic thermal (PV/T) (glass-to-glass) system. Int. J. Therm. Sci. 48(1), 154–164 (2009)CrossRef Joshi, A.S., Tiwari, A., Tiwari, G.N., Dincer, I., Reddy, B.V.: Performance evaluation of a hybrid photovoltaic thermal (PV/T) (glass-to-glass) system. Int. J. Therm. Sci. 48(1), 154–164 (2009)CrossRef
7.
go back to reference Tonui, J.K., Tripanagnostopoulos, Y.: Improved PV/T solar collectors with heat extraction by forced or natural air circulation. Renew. Energy 32(4), 623–637 (2007)CrossRef Tonui, J.K., Tripanagnostopoulos, Y.: Improved PV/T solar collectors with heat extraction by forced or natural air circulation. Renew. Energy 32(4), 623–637 (2007)CrossRef
8.
go back to reference Ji, J., Han, J., Chow, T.-T., Yi, H., Lu, J., He, W., Sun, W.: Effect of fluid flow and packing factor on energy performance of a wall-mounted hybrid photovoltaic/water-heating collector system. Energy Build. 38(12), 1380–1387 (2006)CrossRef Ji, J., Han, J., Chow, T.-T., Yi, H., Lu, J., He, W., Sun, W.: Effect of fluid flow and packing factor on energy performance of a wall-mounted hybrid photovoltaic/water-heating collector system. Energy Build. 38(12), 1380–1387 (2006)CrossRef
9.
go back to reference Chialastri, A., Isaacson, M.: Performance and optimization of a BIPV/T solar air collector for building fenestration applications. Energy Build. 150, 200–210 (2017)CrossRef Chialastri, A., Isaacson, M.: Performance and optimization of a BIPV/T solar air collector for building fenestration applications. Energy Build. 150, 200–210 (2017)CrossRef
10.
go back to reference Zogou, O., Stapountzis, H.: Energy analysis of an improved concept of integrated PV panels in an office building in central Greece. Appl. Energy 88(3), 853–866 (2011)CrossRef Zogou, O., Stapountzis, H.: Energy analysis of an improved concept of integrated PV panels in an office building in central Greece. Appl. Energy 88(3), 853–866 (2011)CrossRef
11.
go back to reference Zogou, O., Stapountzis, H.: Experimental validation of an improved concept of building integrated photovoltaic panels. Renew. Energy 36(12), 3488–3498 (2011)CrossRef Zogou, O., Stapountzis, H.: Experimental validation of an improved concept of building integrated photovoltaic panels. Renew. Energy 36(12), 3488–3498 (2011)CrossRef
12.
go back to reference Athienitis, A.K., Bambara, J., O’Neill, B., Faille, J.: A prototype photovoltaic/thermal system integrated with transpired collector. Sol. Energy 85(1), 139–153 (2011)CrossRef Athienitis, A.K., Bambara, J., O’Neill, B., Faille, J.: A prototype photovoltaic/thermal system integrated with transpired collector. Sol. Energy 85(1), 139–153 (2011)CrossRef
13.
go back to reference Hu, Z., He, W., Hu, D., Lv, S., Wang, L., Ji, J., Chen, H., Ma, J.: Design, construction and performance testing of a PV blind-integrated Trombe wall module. Appl. Energy 203, 643–656 (2017)CrossRef Hu, Z., He, W., Hu, D., Lv, S., Wang, L., Ji, J., Chen, H., Ma, J.: Design, construction and performance testing of a PV blind-integrated Trombe wall module. Appl. Energy 203, 643–656 (2017)CrossRef
14.
go back to reference Sacht, H.M., Bragança, L., Almeida, M., Caram, R.: Glazing daylighting performance and Trombe wall thermal performance of a modular façade system in four different Portuguese cities. Indoor Built Environ. 24(4), 544–563 (2015)CrossRef Sacht, H.M., Bragança, L., Almeida, M., Caram, R.: Glazing daylighting performance and Trombe wall thermal performance of a modular façade system in four different Portuguese cities. Indoor Built Environ. 24(4), 544–563 (2015)CrossRef
15.
go back to reference Yun, G.Y., McEvoy, M., Steemers, K.: Design and overall energy performance of a ventilated photovoltaic façade. Sol. Energy 81(3), 383–394 (2007)CrossRef Yun, G.Y., McEvoy, M., Steemers, K.: Design and overall energy performance of a ventilated photovoltaic façade. Sol. Energy 81(3), 383–394 (2007)CrossRef
16.
go back to reference Lu, L., Law, K.M.: Overall energy performance of semi-transparent single-glazed photovoltaic (PV) window for a typical office in Hong Kong. Renew. Energy 49, 250–254 (2013)CrossRef Lu, L., Law, K.M.: Overall energy performance of semi-transparent single-glazed photovoltaic (PV) window for a typical office in Hong Kong. Renew. Energy 49, 250–254 (2013)CrossRef
17.
go back to reference Li, R., Dai, Y.J., Wang, R.Z.: Experimental and theoretical analysis on thermal performance of solar thermal curtain wall in building envelope. Energy Build. 87, 324–334 (2015)CrossRef Li, R., Dai, Y.J., Wang, R.Z.: Experimental and theoretical analysis on thermal performance of solar thermal curtain wall in building envelope. Energy Build. 87, 324–334 (2015)CrossRef
18.
go back to reference Zhou, C., Liang, R., Zhang, J., Riaz, A.: Experimental study on dynamic thermal response of building attached photovoltaic (BAPV) curtain wall system. Procedia Eng. 205, 314–320 (2017)CrossRef Zhou, C., Liang, R., Zhang, J., Riaz, A.: Experimental study on dynamic thermal response of building attached photovoltaic (BAPV) curtain wall system. Procedia Eng. 205, 314–320 (2017)CrossRef
19.
go back to reference Olivieri, L., Caamaño-Martin, E., Olivieri, F., Neila, J.: Integral energy performance characterization of semi-transparent photovoltaic elements for building integration under real operation conditions. Energy Build. 68, 280–291 (2014)CrossRef Olivieri, L., Caamaño-Martin, E., Olivieri, F., Neila, J.: Integral energy performance characterization of semi-transparent photovoltaic elements for building integration under real operation conditions. Energy Build. 68, 280–291 (2014)CrossRef
20.
go back to reference Atif, M.R., Love, J.A., Littlefair, P.J.: Daylighting monitoring protocols and procedures for buildings. In: A report of IEA Task 21/Annex 29 Daylight in Buildings, International Energy Association (1999) Atif, M.R., Love, J.A., Littlefair, P.J.: Daylighting monitoring protocols and procedures for buildings. In: A report of IEA Task 21/Annex 29 Daylight in Buildings, International Energy Association (1999)
21.
go back to reference Environmental Design, CIBSE Guide A, The Chartered Institution of Building Services Engineers, UK (1999) Environmental Design, CIBSE Guide A, The Chartered Institution of Building Services Engineers, UK (1999)
22.
go back to reference Zhang, X., Du, J.: Lighting performance in office buildings with BIPV facades : visual and non-visual effects. In: Solar World Congress, Daegu, Korea (2015) Zhang, X., Du, J.: Lighting performance in office buildings with BIPV facades : visual and non-visual effects. In: Solar World Congress, Daegu, Korea (2015)
Metadata
Title
Experimental Study on Electrical Power Generation and Natural Daylighting Illuminance Due to Building-Applied Photovoltaic Façade Application
Authors
Ahmad Riaz
Jili Zhang
Chao Zhou
Ruobing Liang
Copyright Year
2020
Publisher
Springer Singapore
DOI