Skip to main content

2020 | OriginalPaper | Buchkapitel

Experimental Study on Electrical Power Generation and Natural Daylighting Illuminance Due to Building-Applied Photovoltaic Façade Application

verfasst von : Ahmad Riaz, Jili Zhang, Chao Zhou, Ruobing Liang

Erschienen in: Proceedings of the 11th International Symposium on Heating, Ventilation and Air Conditioning (ISHVAC 2019)

Verlag: Springer Singapore

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Office buildings consume a huge amount of energy which is responsible for greenhouse gas emissions as well. On the other hand, the photovoltaic systems play a copious role in building energy load reduction and at the same time supply clean electrical energy to the building. In this study, south-facing applied photovoltaics system was built to the exterior of the existing office building with a 0.5 m air gap having 13 m × 4 m dimensions with 8 × 4 of array layout to form building-applied photovoltaic (BAPV). The thermal response of this BAPV system was studied under real outdoor conditions for Dalian. Moreover, the daylighting illuminance (lux) was measured at the working plane inside the office room due to the effect of BAPV façade construction. The 19.8% of power generation efficiency was found for such custom-made PV modules. In addition, the daylighting illuminance was found to be 300–500 lx till 14:30 and afterward led to decrease and have to switch on the artificial daylighting for indoor comfort.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Song, J.-H., Lim, J.-H., Song, S.-Y.: Evaluation of alternatives for reducing thermal bridges in metal panel curtain wall systems. Energy Build. 127, 138–158 (2016)CrossRef Song, J.-H., Lim, J.-H., Song, S.-Y.: Evaluation of alternatives for reducing thermal bridges in metal panel curtain wall systems. Energy Build. 127, 138–158 (2016)CrossRef
2.
Zurück zum Zitat Goossens, D., Goverde, H., Catthoor, F.: Effect of wind on temperature patterns, electrical characteristics, and performance of building-integrated and building-applied inclined photovoltaic modules. Sol. Energy 170, 64–75 (2018)CrossRef Goossens, D., Goverde, H., Catthoor, F.: Effect of wind on temperature patterns, electrical characteristics, and performance of building-integrated and building-applied inclined photovoltaic modules. Sol. Energy 170, 64–75 (2018)CrossRef
3.
Zurück zum Zitat Agathokleous, R.A., Kalogirou, S.A.: Part I: thermal analysis of naturally ventilated BIPV system: experimental investigation and convective heat transfer coefficients estimation. Sol. Energy (2018) Agathokleous, R.A., Kalogirou, S.A.: Part I: thermal analysis of naturally ventilated BIPV system: experimental investigation and convective heat transfer coefficients estimation. Sol. Energy (2018)
4.
Zurück zum Zitat Yang, T., Athienitis, A.K.: A review of research and developments of building-integrated photovoltaic/thermal (BIPV/T) systems. Renew. Sust. Energy Rev 66, 886–912 (2016)CrossRef Yang, T., Athienitis, A.K.: A review of research and developments of building-integrated photovoltaic/thermal (BIPV/T) systems. Renew. Sust. Energy Rev 66, 886–912 (2016)CrossRef
5.
Zurück zum Zitat Tiwari, A., Sodha, M.S., Chandra, A., Joshi, J.C.: Performance evaluation of photovoltaic thermal solar air collector for composite climate of India. Sol. Energy Mater. Sol. Cells 90(2), 175–189 (2006)CrossRef Tiwari, A., Sodha, M.S., Chandra, A., Joshi, J.C.: Performance evaluation of photovoltaic thermal solar air collector for composite climate of India. Sol. Energy Mater. Sol. Cells 90(2), 175–189 (2006)CrossRef
6.
Zurück zum Zitat Joshi, A.S., Tiwari, A., Tiwari, G.N., Dincer, I., Reddy, B.V.: Performance evaluation of a hybrid photovoltaic thermal (PV/T) (glass-to-glass) system. Int. J. Therm. Sci. 48(1), 154–164 (2009)CrossRef Joshi, A.S., Tiwari, A., Tiwari, G.N., Dincer, I., Reddy, B.V.: Performance evaluation of a hybrid photovoltaic thermal (PV/T) (glass-to-glass) system. Int. J. Therm. Sci. 48(1), 154–164 (2009)CrossRef
7.
Zurück zum Zitat Tonui, J.K., Tripanagnostopoulos, Y.: Improved PV/T solar collectors with heat extraction by forced or natural air circulation. Renew. Energy 32(4), 623–637 (2007)CrossRef Tonui, J.K., Tripanagnostopoulos, Y.: Improved PV/T solar collectors with heat extraction by forced or natural air circulation. Renew. Energy 32(4), 623–637 (2007)CrossRef
8.
Zurück zum Zitat Ji, J., Han, J., Chow, T.-T., Yi, H., Lu, J., He, W., Sun, W.: Effect of fluid flow and packing factor on energy performance of a wall-mounted hybrid photovoltaic/water-heating collector system. Energy Build. 38(12), 1380–1387 (2006)CrossRef Ji, J., Han, J., Chow, T.-T., Yi, H., Lu, J., He, W., Sun, W.: Effect of fluid flow and packing factor on energy performance of a wall-mounted hybrid photovoltaic/water-heating collector system. Energy Build. 38(12), 1380–1387 (2006)CrossRef
9.
Zurück zum Zitat Chialastri, A., Isaacson, M.: Performance and optimization of a BIPV/T solar air collector for building fenestration applications. Energy Build. 150, 200–210 (2017)CrossRef Chialastri, A., Isaacson, M.: Performance and optimization of a BIPV/T solar air collector for building fenestration applications. Energy Build. 150, 200–210 (2017)CrossRef
10.
Zurück zum Zitat Zogou, O., Stapountzis, H.: Energy analysis of an improved concept of integrated PV panels in an office building in central Greece. Appl. Energy 88(3), 853–866 (2011)CrossRef Zogou, O., Stapountzis, H.: Energy analysis of an improved concept of integrated PV panels in an office building in central Greece. Appl. Energy 88(3), 853–866 (2011)CrossRef
11.
Zurück zum Zitat Zogou, O., Stapountzis, H.: Experimental validation of an improved concept of building integrated photovoltaic panels. Renew. Energy 36(12), 3488–3498 (2011)CrossRef Zogou, O., Stapountzis, H.: Experimental validation of an improved concept of building integrated photovoltaic panels. Renew. Energy 36(12), 3488–3498 (2011)CrossRef
12.
Zurück zum Zitat Athienitis, A.K., Bambara, J., O’Neill, B., Faille, J.: A prototype photovoltaic/thermal system integrated with transpired collector. Sol. Energy 85(1), 139–153 (2011)CrossRef Athienitis, A.K., Bambara, J., O’Neill, B., Faille, J.: A prototype photovoltaic/thermal system integrated with transpired collector. Sol. Energy 85(1), 139–153 (2011)CrossRef
13.
Zurück zum Zitat Hu, Z., He, W., Hu, D., Lv, S., Wang, L., Ji, J., Chen, H., Ma, J.: Design, construction and performance testing of a PV blind-integrated Trombe wall module. Appl. Energy 203, 643–656 (2017)CrossRef Hu, Z., He, W., Hu, D., Lv, S., Wang, L., Ji, J., Chen, H., Ma, J.: Design, construction and performance testing of a PV blind-integrated Trombe wall module. Appl. Energy 203, 643–656 (2017)CrossRef
14.
Zurück zum Zitat Sacht, H.M., Bragança, L., Almeida, M., Caram, R.: Glazing daylighting performance and Trombe wall thermal performance of a modular façade system in four different Portuguese cities. Indoor Built Environ. 24(4), 544–563 (2015)CrossRef Sacht, H.M., Bragança, L., Almeida, M., Caram, R.: Glazing daylighting performance and Trombe wall thermal performance of a modular façade system in four different Portuguese cities. Indoor Built Environ. 24(4), 544–563 (2015)CrossRef
15.
Zurück zum Zitat Yun, G.Y., McEvoy, M., Steemers, K.: Design and overall energy performance of a ventilated photovoltaic façade. Sol. Energy 81(3), 383–394 (2007)CrossRef Yun, G.Y., McEvoy, M., Steemers, K.: Design and overall energy performance of a ventilated photovoltaic façade. Sol. Energy 81(3), 383–394 (2007)CrossRef
16.
Zurück zum Zitat Lu, L., Law, K.M.: Overall energy performance of semi-transparent single-glazed photovoltaic (PV) window for a typical office in Hong Kong. Renew. Energy 49, 250–254 (2013)CrossRef Lu, L., Law, K.M.: Overall energy performance of semi-transparent single-glazed photovoltaic (PV) window for a typical office in Hong Kong. Renew. Energy 49, 250–254 (2013)CrossRef
17.
Zurück zum Zitat Li, R., Dai, Y.J., Wang, R.Z.: Experimental and theoretical analysis on thermal performance of solar thermal curtain wall in building envelope. Energy Build. 87, 324–334 (2015)CrossRef Li, R., Dai, Y.J., Wang, R.Z.: Experimental and theoretical analysis on thermal performance of solar thermal curtain wall in building envelope. Energy Build. 87, 324–334 (2015)CrossRef
18.
Zurück zum Zitat Zhou, C., Liang, R., Zhang, J., Riaz, A.: Experimental study on dynamic thermal response of building attached photovoltaic (BAPV) curtain wall system. Procedia Eng. 205, 314–320 (2017)CrossRef Zhou, C., Liang, R., Zhang, J., Riaz, A.: Experimental study on dynamic thermal response of building attached photovoltaic (BAPV) curtain wall system. Procedia Eng. 205, 314–320 (2017)CrossRef
19.
Zurück zum Zitat Olivieri, L., Caamaño-Martin, E., Olivieri, F., Neila, J.: Integral energy performance characterization of semi-transparent photovoltaic elements for building integration under real operation conditions. Energy Build. 68, 280–291 (2014)CrossRef Olivieri, L., Caamaño-Martin, E., Olivieri, F., Neila, J.: Integral energy performance characterization of semi-transparent photovoltaic elements for building integration under real operation conditions. Energy Build. 68, 280–291 (2014)CrossRef
20.
Zurück zum Zitat Atif, M.R., Love, J.A., Littlefair, P.J.: Daylighting monitoring protocols and procedures for buildings. In: A report of IEA Task 21/Annex 29 Daylight in Buildings, International Energy Association (1999) Atif, M.R., Love, J.A., Littlefair, P.J.: Daylighting monitoring protocols and procedures for buildings. In: A report of IEA Task 21/Annex 29 Daylight in Buildings, International Energy Association (1999)
21.
Zurück zum Zitat Environmental Design, CIBSE Guide A, The Chartered Institution of Building Services Engineers, UK (1999) Environmental Design, CIBSE Guide A, The Chartered Institution of Building Services Engineers, UK (1999)
22.
Zurück zum Zitat Zhang, X., Du, J.: Lighting performance in office buildings with BIPV facades : visual and non-visual effects. In: Solar World Congress, Daegu, Korea (2015) Zhang, X., Du, J.: Lighting performance in office buildings with BIPV facades : visual and non-visual effects. In: Solar World Congress, Daegu, Korea (2015)
Metadaten
Titel
Experimental Study on Electrical Power Generation and Natural Daylighting Illuminance Due to Building-Applied Photovoltaic Façade Application
verfasst von
Ahmad Riaz
Jili Zhang
Chao Zhou
Ruobing Liang
Copyright-Jahr
2020
Verlag
Springer Singapore
DOI