Skip to main content

2020 | OriginalPaper | Buchkapitel

Development and Experimental Validation of a Finite-Difference Frequency-Domain Model for the Exhaust Air Insulation Wall

verfasst von : Liao Li, Chong Zhang, Jiaqi Hu, Wenjie Gang, Jinbo Wang

Erschienen in: Proceedings of the 11th International Symposium on Heating, Ventilation and Air Conditioning (ISHVAC 2019)

Verlag: Springer Singapore

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

The exhaust air insulation (EAI) wall is a new type of external wall which is mainly composed of an air-permeable porous material, a ventilated cavity, and an exterior protection structure. The EAI wall can reduce the cooling/heating load through the wall by recovering the low-grade thermal energy of exhaust air. A finite-difference frequency-domain (FDFD) model was proposed to predict the thermal response of the EAI wall. The computation time of the FDFD model is lower than that of the finite-difference time-domain (FDTD) model. The experimental test of the EAI wall was conducted in a full-scale test cell under predefined boundary conditions. The experiment results were compared with the calculation results by the FDFD model. Results indicated that the temperatures of the EAI wall calculated by using the FDFD model show good agreement with the measurement data.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Zhang, Y., Bai, X., Mills, F.P., Pezzey, J.C.V.: Rethinking the role of occupant behavior in building energy performance: a review. Energy Build. 172, 279–294 (2018)CrossRef Zhang, Y., Bai, X., Mills, F.P., Pezzey, J.C.V.: Rethinking the role of occupant behavior in building energy performance: a review. Energy Build. 172, 279–294 (2018)CrossRef
2.
Zurück zum Zitat Ascione, F., de Masi, R.F., Mastrullo, R.M., Ruggiero, S., Vanoli, G.P.: Experimental investigation and numerical evaluation of adoption of multi-layered wall with vacuum insulation panel for typical Mediterranean climate. Energy Build. 152, 108–123 (2017)CrossRef Ascione, F., de Masi, R.F., Mastrullo, R.M., Ruggiero, S., Vanoli, G.P.: Experimental investigation and numerical evaluation of adoption of multi-layered wall with vacuum insulation panel for typical Mediterranean climate. Energy Build. 152, 108–123 (2017)CrossRef
3.
Zurück zum Zitat Siddiqui, O., Kumar, R., Fung, A.S., Zhang, D., White, M.A., Whitman, C.A.: Modelling for performance prediction of highly insulated buildings with different types of thermal mass. Appl. Therm. Eng. 122, 139–147 (2017)CrossRef Siddiqui, O., Kumar, R., Fung, A.S., Zhang, D., White, M.A., Whitman, C.A.: Modelling for performance prediction of highly insulated buildings with different types of thermal mass. Appl. Therm. Eng. 122, 139–147 (2017)CrossRef
4.
Zurück zum Zitat Shen, C., Li, X.: Energy saving potential of pipe-embedded building envelope utilizing low-temperature hot water in the heating season. Energy Build. 138, 318–331 (2017)CrossRef Shen, C., Li, X.: Energy saving potential of pipe-embedded building envelope utilizing low-temperature hot water in the heating season. Energy Build. 138, 318–331 (2017)CrossRef
5.
Zurück zum Zitat Yu, J., Huang, J., Xu, X., Ye, H., Xiong, C., Wang, J., Tian, L.: A semi-dynamic heat transfer model of hollow block ventilated wall for thermal performance prediction. Energy Build. 134, 285–294 (2017)CrossRef Yu, J., Huang, J., Xu, X., Ye, H., Xiong, C., Wang, J., Tian, L.: A semi-dynamic heat transfer model of hollow block ventilated wall for thermal performance prediction. Energy Build. 134, 285–294 (2017)CrossRef
6.
Zurück zum Zitat Wang, J., Du, Q., Zhang, C., Xu, X., Gang, W.: Mechanism and preliminary performance analysis of exhaust air insulation for building envelope wall. Energy Build. 173, 516–529 (2018)CrossRef Wang, J., Du, Q., Zhang, C., Xu, X., Gang, W.: Mechanism and preliminary performance analysis of exhaust air insulation for building envelope wall. Energy Build. 173, 516–529 (2018)CrossRef
7.
Zurück zum Zitat Zhang, C., Gang, W., Xu, X., Li, L., Wang, J.: Modelling, experimental test, and design of an active air permeable wall by utilizing the low-grade exhaust air. Appl. Energy 240, 730–743 (2019)CrossRef Zhang, C., Gang, W., Xu, X., Li, L., Wang, J.: Modelling, experimental test, and design of an active air permeable wall by utilizing the low-grade exhaust air. Appl. Energy 240, 730–743 (2019)CrossRef
8.
Zurück zum Zitat Zhang, C., Gang, W., Wang, J., Xu, X., Du, Q.: Numerical and experimental study on the thermal performance improvement of a triple glazed window by utilizing low-grade exhaust air. Energy 167, 1132–1143 (2019)CrossRef Zhang, C., Gang, W., Wang, J., Xu, X., Du, Q.: Numerical and experimental study on the thermal performance improvement of a triple glazed window by utilizing low-grade exhaust air. Energy 167, 1132–1143 (2019)CrossRef
9.
Zurück zum Zitat Zhang, C., Gang, W., Wang, J., Xu, X., Du, Q.: Experimental investigation and dynamic modeling of a triple-glazed exhaust air window with built-in venetian blinds in the cooling season. Appl. Therm. Eng. 140, 73–85 (2018)CrossRef Zhang, C., Gang, W., Wang, J., Xu, X., Du, Q.: Experimental investigation and dynamic modeling of a triple-glazed exhaust air window with built-in venetian blinds in the cooling season. Appl. Therm. Eng. 140, 73–85 (2018)CrossRef
10.
Zurück zum Zitat Zhang, C., Wang, J., Xu, X., Zou, F., Yu, J.: Modeling and thermal performance evaluation of a switchable triple glazing exhaust air window. Appl. Therm. Eng. 92, 8–17 (2016)CrossRef Zhang, C., Wang, J., Xu, X., Zou, F., Yu, J.: Modeling and thermal performance evaluation of a switchable triple glazing exhaust air window. Appl. Therm. Eng. 92, 8–17 (2016)CrossRef
Metadaten
Titel
Development and Experimental Validation of a Finite-Difference Frequency-Domain Model for the Exhaust Air Insulation Wall
verfasst von
Liao Li
Chong Zhang
Jiaqi Hu
Wenjie Gang
Jinbo Wang
Copyright-Jahr
2020
Verlag
Springer Singapore
DOI
https://doi.org/10.1007/978-981-13-9528-4_151