Skip to main content
Top

2020 | OriginalPaper | Chapter

Impedimetric Aptamer-Based Biosensors: Applications

Authors : John-Alexander Preuß, Peggy Reich, Nicole Bahner, Janina Bahnemann

Published in: Aptamers in Biotechnology

Publisher: Springer International Publishing

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Impedimetric aptamer-based biosensors show high potential for handheld devices and point-of-care tests. In this review, we report on recent advances in aptamer-based impedimetric biosensors for applications in biotechnology. We detail on analytes relevant in medical and environmental biotechnology as well as food control, for which aptamer-based impedimetric biosensors were developed. The reviewed biosensors are examined for their performance, including sensitivity, selectivity, response time, and real sample validation. Additionally, the benefits and challenges of impedimetric aptasensors are summarized.

Graphical Abstract

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
5.
go back to reference Pearson TA, Mensah GA, Alexander RW, Anderson JL, Cannon RO, Criqui M, Fadl YY, Fortmann SP, Hong Y, Myers GL, Rifai N, Smith SC, Taubert K, Tracy RP, Vinicor F (2003) Markers of inflammation and cardiovascular disease application to clinical and public health practice – a statement for healthcare professionals from the centers for disease control and prevention and the American Heart Association. Circulation 107(3):499–511. https://doi.org/10.1161/01.Cir.0000052939.59093.45CrossRefPubMed Pearson TA, Mensah GA, Alexander RW, Anderson JL, Cannon RO, Criqui M, Fadl YY, Fortmann SP, Hong Y, Myers GL, Rifai N, Smith SC, Taubert K, Tracy RP, Vinicor F (2003) Markers of inflammation and cardiovascular disease application to clinical and public health practice – a statement for healthcare professionals from the centers for disease control and prevention and the American Heart Association. Circulation 107(3):499–511. https://​doi.​org/​10.​1161/​01.​Cir.​0000052939.​59093.​45CrossRefPubMed
10.
go back to reference Bing X, Wang G (2017) Label free C-reactive protein detection based on an electrochemical sensor for clinical application. Int J Electrochem Sci 12(7):6304–6314CrossRef Bing X, Wang G (2017) Label free C-reactive protein detection based on an electrochemical sensor for clinical application. Int J Electrochem Sci 12(7):6304–6314CrossRef
11.
16.
go back to reference Zhang Z, Zhang S, He L, Peng D, Yan F, Wang M, Zhao J, Zhang H, Fang S (2015) Feasible electrochemical biosensor based on plasma polymerization-assisted composite of polyacrylic acid and hollow TiO2 spheres for sensitively detecting lysozyme. Biosens Bioelectron 74:384–390. https://doi.org/10.1016/j.bios.2015.06.062 Zhang Z, Zhang S, He L, Peng D, Yan F, Wang M, Zhao J, Zhang H, Fang S (2015) Feasible electrochemical biosensor based on plasma polymerization-assisted composite of polyacrylic acid and hollow TiO2 spheres for sensitively detecting lysozyme. Biosens Bioelectron 74:384–390. https://​doi.​org/​10.​1016/​j.​bios.​2015.​06.​062
32.
go back to reference Figueroa-Miranda G, Feng L, Shiu SC-C, Dirkzwager RM, Cheung Y-W, Tanner JA, Schöning MJ, Offenhäusser A, Mayer D (2018) Aptamer-based electrochemical biosensor for highly sensitive and selective malaria detection with adjustable dynamic response range and reusability. Sensors Actuators B Chem 255:235–243. https://doi.org/10.1016/j.snb.2017.07.117CrossRef Figueroa-Miranda G, Feng L, Shiu SC-C, Dirkzwager RM, Cheung Y-W, Tanner JA, Schöning MJ, Offenhäusser A, Mayer D (2018) Aptamer-based electrochemical biosensor for highly sensitive and selective malaria detection with adjustable dynamic response range and reusability. Sensors Actuators B Chem 255:235–243. https://​doi.​org/​10.​1016/​j.​snb.​2017.​07.​117CrossRef
42.
43.
go back to reference Shekari Z, Zare HR, Falahati A (2017) Developing an impedimetric aptasensor for selective label–free detection of CEA as a cancer biomarker based on gold nanoparticles loaded in functionalized mesoporous silica films. J Electrochem Soc 164(13):B739–B745. https://doi.org/10.1149/2.1991713jesCrossRef Shekari Z, Zare HR, Falahati A (2017) Developing an impedimetric aptasensor for selective label–free detection of CEA as a cancer biomarker based on gold nanoparticles loaded in functionalized mesoporous silica films. J Electrochem Soc 164(13):B739–B745. https://​doi.​org/​10.​1149/​2.​1991713jesCrossRef
45.
50.
go back to reference Salven P, Perhoniemi V, Tykkä H, Mäenpää H, Joensuu H (1999) Serum VEGF levels in women with a benign breast tumor or breast cancer. Breast Cancer Res Treat 53(2):161–166CrossRef Salven P, Perhoniemi V, Tykkä H, Mäenpää H, Joensuu H (1999) Serum VEGF levels in women with a benign breast tumor or breast cancer. Breast Cancer Res Treat 53(2):161–166CrossRef
65.
go back to reference Alsirawan MB, Mohammad M, Al-kasmi B, Alhareth K, El-Hammadi M (2013) Development and validation of a simple HPLC method for the determination of ibuprofen sticking onto punch faces. Int J Pharm Pharm Sci 5(Suppl 4):227–231 Alsirawan MB, Mohammad M, Al-kasmi B, Alhareth K, El-Hammadi M (2013) Development and validation of a simple HPLC method for the determination of ibuprofen sticking onto punch faces. Int J Pharm Pharm Sci 5(Suppl 4):227–231
74.
go back to reference Commission Regulation (EC) No 181/2003 (2003) 2003/181/EC: commission decision of 13 March 2003 amending decision 2002/657/EC as regards the setting of minimum required performance limits (MRPLs) for certain residues in food of animal origin Commission Regulation (EC) No 181/2003 (2003) 2003/181/EC: commission decision of 13 March 2003 amending decision 2002/657/EC as regards the setting of minimum required performance limits (MRPLs) for certain residues in food of animal origin
94.
go back to reference Wanatabe S, Ito S, Kamata Y, Omoda N, Yamazaki T, Munakata H, Kaneko T, Yuasa Y (2001) Development of competitive enzyme-linked immunosorbent assays (ELISAs) based on monoclonal antibodies for chloronicotinoid insecticides imidacloprid and acetamiprid. Anal Chim Acta 427(2):211–219. https://doi.org/10.1016/S0003-2670(00)01126-0CrossRef Wanatabe S, Ito S, Kamata Y, Omoda N, Yamazaki T, Munakata H, Kaneko T, Yuasa Y (2001) Development of competitive enzyme-linked immunosorbent assays (ELISAs) based on monoclonal antibodies for chloronicotinoid insecticides imidacloprid and acetamiprid. Anal Chim Acta 427(2):211–219. https://​doi.​org/​10.​1016/​S0003-2670(00)01126-0CrossRef
97.
99.
go back to reference Commission Regulation (EU) No 10/2011 (2011) Commission Regulation (EU) No 10/2011 of 14 January 2011 on plastic materials and articles intended to come into contact with food Commission Regulation (EU) No 10/2011 (2011) Commission Regulation (EU) No 10/2011 of 14 January 2011 on plastic materials and articles intended to come into contact with food
102.
go back to reference Frisvad JC, Thrane U, Samson RA, Pitt JI (2006) Important mycotoxins and the fungi which produce them. In: Advances in food mycology. Springer, Boston, pp 3–31CrossRef Frisvad JC, Thrane U, Samson RA, Pitt JI (2006) Important mycotoxins and the fungi which produce them. In: Advances in food mycology. Springer, Boston, pp 3–31CrossRef
106.
go back to reference Evtugyn G, Porfireva A, Sitdikov R, Evtugyn V, Stoikov I, Antipin I, Hianik T (2013) Electrochemical APTASENSOR for the determination of Ochratoxin A at the Au electrode modified with Ag nanoparticles decorated with macrocyclic ligand. Electroanalysis 25(8):1847–1854. https://doi.org/10.1002/elan.201300164CrossRef Evtugyn G, Porfireva A, Sitdikov R, Evtugyn V, Stoikov I, Antipin I, Hianik T (2013) Electrochemical APTASENSOR for the determination of Ochratoxin A at the Au electrode modified with Ag nanoparticles decorated with macrocyclic ligand. Electroanalysis 25(8):1847–1854. https://​doi.​org/​10.​1002/​elan.​201300164CrossRef
111.
116.
go back to reference Commission Regulation (EU) No 165/2010 (2010) Commission Regulation (EU) No 165/2010 of 26 February 2010 amending Regulation (EC) No 1881/2006 setting maximum levels for certain contaminants in foodstuffs as regards aflatoxins Commission Regulation (EU) No 165/2010 (2010) Commission Regulation (EU) No 165/2010 of 26 February 2010 amending Regulation (EC) No 1881/2006 setting maximum levels for certain contaminants in foodstuffs as regards aflatoxins
137.
go back to reference Vanegas DC, Rong Y, Schwalb N, Hills KD, Gomes C, McLamore ES (2015) Rapid detection of listeria spp. using an internalin A aptasensor based on carbon-metal nanohybrid structures. In: Proceedings of SPIE – smart biomedical and physiological sensor technology XIISPIE Sensing Technology + Applications. SPIE, Baltimore. https://doi.org/10.1117/12.2177441CrossRef Vanegas DC, Rong Y, Schwalb N, Hills KD, Gomes C, McLamore ES (2015) Rapid detection of listeria spp. using an internalin A aptasensor based on carbon-metal nanohybrid structures. In: Proceedings of SPIE – smart biomedical and physiological sensor technology XIISPIE Sensing Technology + Applications. SPIE, Baltimore. https://​doi.​org/​10.​1117/​12.​2177441CrossRef
138.
go back to reference Sidhu R, Rong Y, Vanegas DC, Claussen J, McLamore ES, Gomes C (2016) Impedance biosensor for the rapid detection of listeria spp. based on aptamer functionalized Pt-interdigitated microelectrodes array. In: Cullum BM, Kiehl D, McLamore ES (eds) Proceedings of SPIE – smart biomedical and physiological sensor technology XIIISPIE Commercial + Scientific Sensing and Imaging. SPIE, Baltimore. https://doi.org/10.1117/12.2223443CrossRef Sidhu R, Rong Y, Vanegas DC, Claussen J, McLamore ES, Gomes C (2016) Impedance biosensor for the rapid detection of listeria spp. based on aptamer functionalized Pt-interdigitated microelectrodes array. In: Cullum BM, Kiehl D, McLamore ES (eds) Proceedings of SPIE – smart biomedical and physiological sensor technology XIIISPIE Commercial + Scientific Sensing and Imaging. SPIE, Baltimore. https://​doi.​org/​10.​1117/​12.​2223443CrossRef
142.
go back to reference Commission Regulation (EC) No 2073/2005 (2005) Commission Regulation (EC) No 2073/2005 of 15 November 2005 on microbiological criteria for foodstuffs Commission Regulation (EC) No 2073/2005 (2005) Commission Regulation (EC) No 2073/2005 of 15 November 2005 on microbiological criteria for foodstuffs
Metadata
Title
Impedimetric Aptamer-Based Biosensors: Applications
Authors
John-Alexander Preuß
Peggy Reich
Nicole Bahner
Janina Bahnemann
Copyright Year
2020
DOI
https://doi.org/10.1007/10_2020_125

Premium Partners