Skip to main content
Top

2019 | OriginalPaper | Chapter

Impedimetric Method to Monitor Biological Layer Formation on Central Venous Catheters for Hemodialysis Made of Carbothane

Authors : Ewa Paradowska, Marta Nycz, Katarzyna Arkusz, Bartosz Kudliński, Elżbieta Krasicka-Cydzik

Published in: Biomechanics in Medicine and Biology

Publisher: Springer International Publishing

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

The aim of the study was to specify by an impedimetric method the changes observed on the inner wall of central venous catheters for hemodialysis leading to the formation of a biological film. To evaluate these changes a patient-dialyzer model was built in which experimental parameters were kept closely similar to the clinical conditions of hemodialysis. The impedance spectra and SEM/EDS analysis of the biological layer deposited on the inner surface of the distal part of the catheter gave an insight into the structure of film formation and its chemical composition. Since an early detection of biofilm formation inside the distal part of the catheter is crucial for the safety of medical treatment and it usually prompts the implementation of antibiotic therapy. Developed impedimetric method can minimize the risk of infection and ensure the continuity of treatment.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
2.
go back to reference Saxena, A.K., Panhotra, B.R.: Haemodialysis catheter-related bloodstream infections: current treatment options and strategies for prevention. Swiss Med. Wkly. 127–138 (2005) Saxena, A.K., Panhotra, B.R.: Haemodialysis catheter-related bloodstream infections: current treatment options and strategies for prevention. Swiss Med. Wkly. 127–138 (2005)
5.
go back to reference Tsukashita, M., Anda, A., Balsam, L.: Type A aortic dissection: a rare complication of central venous catheter placement. J. Card. Surg. 29, 368–370 (2014)CrossRef Tsukashita, M., Anda, A., Balsam, L.: Type A aortic dissection: a rare complication of central venous catheter placement. J. Card. Surg. 29, 368–370 (2014)CrossRef
7.
go back to reference Raad, I., Hanna, H., Maki, D.: Intravascular catheter-related infections: advances in diagnosis, prevention, and management. Lan. Infect. Dis. 7, 645–657 (2007)CrossRef Raad, I., Hanna, H., Maki, D.: Intravascular catheter-related infections: advances in diagnosis, prevention, and management. Lan. Infect. Dis. 7, 645–657 (2007)CrossRef
9.
go back to reference Menglin, T., Mei, F., Lijun, C., Jinmei, Z., Peng, K., Shuhua, L.: Closed blood conservation device for reducing catheter-related infections in children after cardiac surgery. Crit. Care Nurse 5, 53–61 (2014) Menglin, T., Mei, F., Lijun, C., Jinmei, Z., Peng, K., Shuhua, L.: Closed blood conservation device for reducing catheter-related infections in children after cardiac surgery. Crit. Care Nurse 5, 53–61 (2014)
10.
go back to reference Horvath, R., Collignon, P.: Controlling intravascular catheter infections. Aust. Prescr. 26, 41–43 (2003)CrossRef Horvath, R., Collignon, P.: Controlling intravascular catheter infections. Aust. Prescr. 26, 41–43 (2003)CrossRef
11.
go back to reference Elliott, T.S.J.: The pathogensis and prevention of intervascular catheter infections Central Venous Catheters. Lancet Infect. Dis. 206-215 (2009) Elliott, T.S.J.: The pathogensis and prevention of intervascular catheter infections Central Venous Catheters. Lancet Infect. Dis. 206-215 (2009)
12.
15.
go back to reference Maczynska, B., Przondo-Mordarska, A.: Bloodstream infections related to venous access. Zakazenia, p. 4 (2011) Maczynska, B., Przondo-Mordarska, A.: Bloodstream infections related to venous access. Zakazenia, p. 4 (2011)
17.
go back to reference Kutner, D.J.: Thrombotic complications of centra venous catheters in cancer patients. Oncologist 9, 207–216 (2004)CrossRef Kutner, D.J.: Thrombotic complications of centra venous catheters in cancer patients. Oncologist 9, 207–216 (2004)CrossRef
20.
go back to reference Kingdon, E.J., et al.: Atrial thrombus and central venous dialysis catheters. Am. J. Kidney Dis. 38, 631–639 (2001)CrossRef Kingdon, E.J., et al.: Atrial thrombus and central venous dialysis catheters. Am. J. Kidney Dis. 38, 631–639 (2001)CrossRef
22.
go back to reference Paredes, J., Becerro, S., Arizti, F., Aguinaga, A., Del Pozo, J.L., Arana, S.: Real time monitoring of the impedance characteristics of Staphylococcal bacterial biofilm cultures with a modified CDC reactor system. Biosens. Bioelectron. 38, 226–232 (2012)CrossRef Paredes, J., Becerro, S., Arizti, F., Aguinaga, A., Del Pozo, J.L., Arana, S.: Real time monitoring of the impedance characteristics of Staphylococcal bacterial biofilm cultures with a modified CDC reactor system. Biosens. Bioelectron. 38, 226–232 (2012)CrossRef
26.
go back to reference Wei, H., Ding, D., Wei, S., Guo, Z.: Anticorrosive conductive polyurethane multiwalled carbon nanotube nanocomposites. J. Mater. Chem. 45, 10805–10813 (2013)CrossRef Wei, H., Ding, D., Wei, S., Guo, Z.: Anticorrosive conductive polyurethane multiwalled carbon nanotube nanocomposites. J. Mater. Chem. 45, 10805–10813 (2013)CrossRef
27.
go back to reference Ookubo, A., Nishida, M., Ooi, K., Ishida, K., Hashimura, Y., Ikawa, A., Yoshimura, Y., Kawada, J.: Mechanism of phosphate adsorption to a three-dimensional structure of boehmite in the presence of bovine serum albumin. J. Pharm. Sci. 82, 744–749 (1993)CrossRef Ookubo, A., Nishida, M., Ooi, K., Ishida, K., Hashimura, Y., Ikawa, A., Yoshimura, Y., Kawada, J.: Mechanism of phosphate adsorption to a three-dimensional structure of boehmite in the presence of bovine serum albumin. J. Pharm. Sci. 82, 744–749 (1993)CrossRef
29.
go back to reference Moradi, M., Yeganeh, H., Pazokifard, S.: Synthesis and assessment of novel anticorrosive polyurethane coatings containing an amine-functionalized nanoclay additive prepared by the cathodic electrophoretic deposition method. RSC Adv. 6, 28089–28102 (2016). https://doi.org/10.1039/C5RA26609BCrossRef Moradi, M., Yeganeh, H., Pazokifard, S.: Synthesis and assessment of novel anticorrosive polyurethane coatings containing an amine-functionalized nanoclay additive prepared by the cathodic electrophoretic deposition method. RSC Adv. 6, 28089–28102 (2016). https://​doi.​org/​10.​1039/​C5RA26609BCrossRef
30.
go back to reference Mohsen, Q., SFadl-allah, S.A., El-Shenawy, N.S.: Electrochemical impedance spectroscopy study of the adsorption behavior of bovine serum albumin at biomimetic calcium - phosphate coating. Int. J. Electrochem. Sc. 7, 4510–4527 (2012) Mohsen, Q., SFadl-allah, S.A., El-Shenawy, N.S.: Electrochemical impedance spectroscopy study of the adsorption behavior of bovine serum albumin at biomimetic calcium - phosphate coating. Int. J. Electrochem. Sc. 7, 4510–4527 (2012)
31.
go back to reference Vlasova, I., Saletsky, A.: Study of the denaturation of human serum albumin by sodium dodecyl sulfate using the intrinsic fluorescence of albumin. J. App. Spectrosc. 76, 536–541 (2009)CrossRef Vlasova, I., Saletsky, A.: Study of the denaturation of human serum albumin by sodium dodecyl sulfate using the intrinsic fluorescence of albumin. J. App. Spectrosc. 76, 536–541 (2009)CrossRef
Metadata
Title
Impedimetric Method to Monitor Biological Layer Formation on Central Venous Catheters for Hemodialysis Made of Carbothane
Authors
Ewa Paradowska
Marta Nycz
Katarzyna Arkusz
Bartosz Kudliński
Elżbieta Krasicka-Cydzik
Copyright Year
2019
DOI
https://doi.org/10.1007/978-3-319-97286-2_4