Skip to main content
Top
Published in: The International Journal of Life Cycle Assessment 3/2013

01-03-2013 | LCIA OF IMPACTS ON HUMAN HEALTH AND ECOSYSTEMS

Integrating human health impact from indoor emissions into an LCA: a case study evaluating the significance of the use stage

Authors: Christofer Skaar, Rikke B. Jørgensen

Published in: The International Journal of Life Cycle Assessment | Issue 3/2013

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Purpose

Indoor emissions of toxic substances from products can have a negative effect on human health. These are typically not considered in a life cycle assessment (LCA), potentially underestimating the importance of the use stage. The purpose of this paper is to develop a method that, based on a set of measured emission rates, calculates the impact on human health during the use stage of products that are used indoors and that emit volatile organic compounds (VOCs).

Methods

Emissions from a product are measured in a test chamber and reported as a set of emission rates (microgrammes per hour) at specific points in time (hour/day). Constrained non-linear regression (CNLR) analysis is then used to determine parameters for three emission models, and a model is selected based on goodness of fit with the measured emission rates (R 2 and expert judgement). The emission model is integrated over a defined time period to estimate the total use stage emissions per functional unit (FU). The total emissions are subsequently integrated in a homogeneously mixed one-box model within the USEtox model. Intake fraction (iF) is calculated based on size of residential home, inhalation rate, exposure time, ventilation rate, mixing factor and number of people exposed.

Results and discussion

The method is tested in a case study of a chair, with the results showing that the impacts in the use stage are in most cases significantly higher than from the production and disposal stages combined. The sensitivity to parameter variations is evaluated. Intake fraction (factor of 761), replacement frequency (factor of 70) and emission model (factor of 24) are found to be the most important model parameters. Limiting early exposure (>14 % of emissions may occur in the first month and >50 % in the first year) and replacing furniture less frequently will reduce exposure.

Conclusions

The case study shows that the impact on human health from indoor emissions can be of significance, when compared to the impact on human health from total outdoor emissions. Without specific exposure data (e.g. ventilation rates) the uncertainty will be high. The developed method is applicable to all products that emit VOCs, provided that the emission rate can be modelled using an exponential decay model and that the product amount is related to a meaningful functional unit. It is recommended that when performing an LCA of products that emit VOCs, the indoor use stage is included in the life cycle impact assessment.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Appendix
Available only for authorised users
Literature
go back to reference Afsset (2009) Saisine Afsset no. 2004/11. Afsset, Paris Afsset (2009) Saisine Afsset no. 2004/11. Afsset, Paris
go back to reference Allan M, Richardson GM (1998) Probability density functions describing 24-hour inhalation rates for use in human health risk assessments. Hum Ecol Risk Assess 4(2):379–408CrossRef Allan M, Richardson GM (1998) Probability density functions describing 24-hour inhalation rates for use in human health risk assessments. Hum Ecol Risk Assess 4(2):379–408CrossRef
go back to reference Andrews E, Lesage P, Benoît C, Parent J, Norris G, Revéret J-P (2009) Life cycle attribute assessment—case study of Quebec greenhouse tomatoes. J Ind Ecol 13(4):565–578CrossRef Andrews E, Lesage P, Benoît C, Parent J, Norris G, Revéret J-P (2009) Life cycle attribute assessment—case study of Quebec greenhouse tomatoes. J Ind Ecol 13(4):565–578CrossRef
go back to reference Bennett DH, McKone TE, Evans JS, Nazaroff WW, Margni MD, Jolliet O, Smith KR (2002) Defining intake fraction. Environ Sci Technol 36(9):206a–211aCrossRef Bennett DH, McKone TE, Evans JS, Nazaroff WW, Margni MD, Jolliet O, Smith KR (2002) Defining intake fraction. Environ Sci Technol 36(9):206a–211aCrossRef
go back to reference Berglund B, Johansson I, Lindvall T (1989) Volatile organic compounds from used building materials in a simulated chamber study. Environ Int 15:383–387CrossRef Berglund B, Johansson I, Lindvall T (1989) Volatile organic compounds from used building materials in a simulated chamber study. Environ Int 15:383–387CrossRef
go back to reference Blondel A, Plaisance H (2011) Screening of formaldehyde indoor sources and quantification of their emission using a passive sampler. Build Environ 46(6):1284–1291CrossRef Blondel A, Plaisance H (2011) Screening of formaldehyde indoor sources and quantification of their emission using a passive sampler. Build Environ 46(6):1284–1291CrossRef
go back to reference Brasche S, Bischof W (2005) Daily time spent indoors in German homes—baseline data for the assessment of indoor exposure of German occupants. Int J Hyg Environ Heal 208(4):247–253CrossRef Brasche S, Bischof W (2005) Daily time spent indoors in German homes—baseline data for the assessment of indoor exposure of German occupants. Int J Hyg Environ Heal 208(4):247–253CrossRef
go back to reference Brown SK (1999) Chamber assessment of formaldehyde and VOC emissions from wood-based panels. Indoor Air 9(3):209–215CrossRef Brown SK (1999) Chamber assessment of formaldehyde and VOC emissions from wood-based panels. Indoor Air 9(3):209–215CrossRef
go back to reference Chang JCS, Sparks LE, Guo Z, Fortmann R (1998) Evaluation of sink effects on VOCs from a latex paint. J Air Waste Manag Assoc 48(10):953–958 Chang JCS, Sparks LE, Guo Z, Fortmann R (1998) Evaluation of sink effects on VOCs from a latex paint. J Air Waste Manag Assoc 48(10):953–958
go back to reference Chen J-C, Wey M-Y, Chiang B-C, Hsieh S-M (1998) The simulation of hexavalent chromium formation under various incineration conditions. Chemosphere 36(7):1553–1564CrossRef Chen J-C, Wey M-Y, Chiang B-C, Hsieh S-M (1998) The simulation of hexavalent chromium formation under various incineration conditions. Chemosphere 36(7):1553–1564CrossRef
go back to reference Choi H, Schmidbauer N, Sundell J, Hasselgren M, Spenger J, Bornehag C-G (2010) Common houshold chemicals and the allergy risks in pre-school children. PLoS One 5(10):e13423CrossRef Choi H, Schmidbauer N, Sundell J, Hasselgren M, Spenger J, Bornehag C-G (2010) Common houshold chemicals and the allergy risks in pre-school children. PLoS One 5(10):e13423CrossRef
go back to reference Colombo A, De Bortoli M, Knöppel H, Pecchio E, Visser H (1993) Adsorption on selected volatile organic compounds on a carpet, a wall coating, and a gypsum board in a test chamber. Indoor Air 3:276–282CrossRef Colombo A, De Bortoli M, Knöppel H, Pecchio E, Visser H (1993) Adsorption on selected volatile organic compounds on a carpet, a wall coating, and a gypsum board in a test chamber. Indoor Air 3:276–282CrossRef
go back to reference ECA (1997) Evaluation of VOC emissions from building products. European Comission, Brussels ECA (1997) Evaluation of VOC emissions from building products. European Comission, Brussels
go back to reference EPD Norway (2008) Product category rules for preparing an Environmental Product Declaration (EPD) for product group seating solution. EPD Norway, Oslo EPD Norway (2008) Product category rules for preparing an Environmental Product Declaration (EPD) for product group seating solution. EPD Norway, Oslo
go back to reference Fet AM, Skaar C, Michelsen O (2009) Product category rules and environmental product declarations as tools to promote sustainable products: experiences from a case study of furniture production. Clean Technol Environ 11(2):201–207CrossRef Fet AM, Skaar C, Michelsen O (2009) Product category rules and environmental product declarations as tools to promote sustainable products: experiences from a case study of furniture production. Clean Technol Environ 11(2):201–207CrossRef
go back to reference Greenguard (2011) GREENGUARD Environmental Institute Formaldehyde Free Verification Requirement. Marietta Greenguard (2011) GREENGUARD Environmental Institute Formaldehyde Free Verification Requirement. Marietta
go back to reference Guo Z (2002a) Review of indoor emission source models. Part 1. Overview. Environ Pollut 120(3):533–549CrossRef Guo Z (2002a) Review of indoor emission source models. Part 1. Overview. Environ Pollut 120(3):533–549CrossRef
go back to reference Guo Z (2002b) Review of indoor emission source models. Part 2. Parameter estimation. Environ Pollut 120(3):551–564CrossRef Guo Z (2002b) Review of indoor emission source models. Part 2. Parameter estimation. Environ Pollut 120(3):551–564CrossRef
go back to reference He G, Yang X, Shaw CY (2005) Material emission parameters obtained through regression. Indoor Built Environ 14(1):59–68CrossRef He G, Yang X, Shaw CY (2005) Material emission parameters obtained through regression. Indoor Built Environ 14(1):59–68CrossRef
go back to reference Hellweg S, Demou E, Bruzzi R, Meijer A, Rosenbaum RK, Huijbregts MAJ, McKone TE (2009) Integrating human indoor air pollutant exposure within life cycle impact assessment. Environ Sci Technol 43(6):1670–1679CrossRef Hellweg S, Demou E, Bruzzi R, Meijer A, Rosenbaum RK, Huijbregts MAJ, McKone TE (2009) Integrating human indoor air pollutant exposure within life cycle impact assessment. Environ Sci Technol 43(6):1670–1679CrossRef
go back to reference Hun DE, Corsi RL, Morandi MT, Siegel JA (2010) Formaldehyde in residences: long-term indoor concentrations and influencing factors. Indoor Air 20(3):196–203CrossRef Hun DE, Corsi RL, Morandi MT, Siegel JA (2010) Formaldehyde in residences: long-term indoor concentrations and influencing factors. Indoor Air 20(3):196–203CrossRef
go back to reference International Organization for Standardization (2001) Indoor air—part 3: determination of formaldehyde and other carbonyl compounds - Active sampling method (ISO 16000–3:2001). International Organization for Standardization, Geneva International Organization for Standardization (2001) Indoor air—part 3: determination of formaldehyde and other carbonyl compounds - Active sampling method (ISO 16000–3:2001). International Organization for Standardization, Geneva
go back to reference International Organization for Standardization (2004) Indoor air—part 6: determination of volatile organic compounds in indoor and test chamber air by active sampling on Tenax TA sorbent, thermal desorption and gas chromatography using MS/FID (ISO 16000–6:2004). International Organization for Standardization, Geneva International Organization for Standardization (2004) Indoor air—part 6: determination of volatile organic compounds in indoor and test chamber air by active sampling on Tenax TA sorbent, thermal desorption and gas chromatography using MS/FID (ISO 16000–6:2004). International Organization for Standardization, Geneva
go back to reference International Organization for Standardization (2006a) Environmental management—life cycle assessment—requirements and guidelines (ISO 14044:2006). International Organization for Standardization, Geneva International Organization for Standardization (2006a) Environmental management—life cycle assessment—requirements and guidelines (ISO 14044:2006). International Organization for Standardization, Geneva
go back to reference International Organization for Standardization (2006b) Indoor air—part 9: determination of the emission of volatile organic compounds from building products and furnishing—emission test chamber method (ISO 16000–9:2006). International Organization for Standardization, Geneva International Organization for Standardization (2006b) Indoor air—part 9: determination of the emission of volatile organic compounds from building products and furnishing—emission test chamber method (ISO 16000–9:2006). International Organization for Standardization, Geneva
go back to reference International Organization for Standardization (2006c) Indoor air—part 11: determination of the emission of volatile organic compounds from building products and furnishing—sampling, storage of samples and preparation of test specimens (ISO 16000–11:2006). International Organization for Standardization, Geneva International Organization for Standardization (2006c) Indoor air—part 11: determination of the emission of volatile organic compounds from building products and furnishing—sampling, storage of samples and preparation of test specimens (ISO 16000–11:2006). International Organization for Standardization, Geneva
go back to reference Jørgensen RB, Bjørseth O (1999) Sorption behaviour of volatile organic compounds on material surfaces—the influence of combinations of compounds and materials compared to sorption of single compounds on single materials. Environ Int 25:17–27CrossRef Jørgensen RB, Bjørseth O (1999) Sorption behaviour of volatile organic compounds on material surfaces—the influence of combinations of compounds and materials compared to sorption of single compounds on single materials. Environ Int 25:17–27CrossRef
go back to reference Jørgensen RB, Bjørseth O, Malvik B (1999) Chamber testing of adsorption of volatile organic compounds (VOCs) on material surfaces. Indoor Air 9(1):2–9CrossRef Jørgensen RB, Bjørseth O, Malvik B (1999) Chamber testing of adsorption of volatile organic compounds (VOCs) on material surfaces. Indoor Air 9(1):2–9CrossRef
go back to reference Jørgensen RB, Dokka TH, Bjørseth O (2000) Introduction of a sink–diffusion model to describe the interaction between VOCs and material surfaces. Indoor Air 10:27–38CrossRef Jørgensen RB, Dokka TH, Bjørseth O (2000) Introduction of a sink–diffusion model to describe the interaction between VOCs and material surfaces. Indoor Air 10:27–38CrossRef
go back to reference Kim I, Hur T (2009) Integration of working environment into life cycle assessment framework. Int J Life Cycle Assess 14(4):290–301CrossRef Kim I, Hur T (2009) Integration of working environment into life cycle assessment framework. Int J Life Cycle Assess 14(4):290–301CrossRef
go back to reference Kuehn BM (2008) Stronger formaldehyde regulation sought. JAMA 299(17):2015–2015CrossRef Kuehn BM (2008) Stronger formaldehyde regulation sought. JAMA 299(17):2015–2015CrossRef
go back to reference Meijer A, Huijbregts MAJ, Reijnders L (2005) Human health damages due to indoor sources of organic compounds and radioactivity in life cycle impact assessment of dwellings—part 1: characterisation factors. Int J Life Cycle Assess 10(5):309–316CrossRef Meijer A, Huijbregts MAJ, Reijnders L (2005) Human health damages due to indoor sources of organic compounds and radioactivity in life cycle impact assessment of dwellings—part 1: characterisation factors. Int J Life Cycle Assess 10(5):309–316CrossRef
go back to reference National Research Council (1991) Human exposure assessment for airborne pollutants: advances and opportunities. National Academy Press, Washington, DC National Research Council (1991) Human exposure assessment for airborne pollutants: advances and opportunities. National Academy Press, Washington, DC
go back to reference Nordic Ecolabelling (2011a) Nordic Ecolabelling of furniture and fitments. Nordic Ecolabelling, Oslo Nordic Ecolabelling (2011a) Nordic Ecolabelling of furniture and fitments. Nordic Ecolabelling, Oslo
go back to reference Nordic Ecolabelling (2011b) Nordic Ecolabelling of panels for the building, decoration and furniture industries. Nordic Ecolabelling, Oslo Nordic Ecolabelling (2011b) Nordic Ecolabelling of panels for the building, decoration and furniture industries. Nordic Ecolabelling, Oslo
go back to reference Øie L (1998) The ventilation rate of 344 Oslo residences. Indoor Air 8(3):190–196CrossRef Øie L (1998) The ventilation rate of 344 Oslo residences. Indoor Air 8(3):190–196CrossRef
go back to reference Rosenbaum R, Bachmann T, Gold L, Huijbregts M, Jolliet O, Juraske R, Koehler A, Larsen H, MacLeod M, Margni M, McKone T, Payet J, Schuhmacher M, van de Meent D, Hauschild M (2008) USEtox—the UNEP-SETAC toxicity model: recommended characterisation factors for human toxicity and freshwater ecotoxicity in life cycle impact assessment. Int J Life Cycle Assess 13(7):532–546CrossRef Rosenbaum R, Bachmann T, Gold L, Huijbregts M, Jolliet O, Juraske R, Koehler A, Larsen H, MacLeod M, Margni M, McKone T, Payet J, Schuhmacher M, van de Meent D, Hauschild M (2008) USEtox—the UNEP-SETAC toxicity model: recommended characterisation factors for human toxicity and freshwater ecotoxicity in life cycle impact assessment. Int J Life Cycle Assess 13(7):532–546CrossRef
go back to reference Rydberg T, Westerdahl J, Hallberg E, Öman A, Andersson PL, Haglund P, Holmgren T, Fuhrman F, Molander S, Tivander J (2012) Emissions of additives from plastics in the societal material stock: a case study for Sweden. In: Bilitewski B, Darbra RM, Barceló D (eds) The handbook of environmental chemistry volume 18. Springer, Berlin, pp 133–149 Rydberg T, Westerdahl J, Hallberg E, Öman A, Andersson PL, Haglund P, Holmgren T, Fuhrman F, Molander S, Tivander J (2012) Emissions of additives from plastics in the societal material stock: a case study for Sweden. In: Bilitewski B, Darbra RM, Barceló D (eds) The handbook of environmental chemistry volume 18. Springer, Berlin, pp 133–149
go back to reference Saarela K, Tirkkonen T (2004) M1, emission classification of building materials: protocol for chemical and sensory testing of building materials. VTT, Finland Saarela K, Tirkkonen T (2004) M1, emission classification of building materials: protocol for chemical and sensory testing of building materials. VTT, Finland
go back to reference Salthammer T, Mentese S, Marutzky R (2010) Formaldehyde in the indoor environment. Chem Rev 110(4):2536–2572CrossRef Salthammer T, Mentese S, Marutzky R (2010) Formaldehyde in the indoor environment. Chem Rev 110(4):2536–2572CrossRef
go back to reference Sexton K, Adgate JL, Church TR, Ashley DL, Needham LL, Ramachandran G, Fredrickson AL, Ryan AD (2005) Children’s exposure to volatile organic compounds as determined by longitudinal measurements in blood. Environ Health Perspect 113(3):342–349CrossRef Sexton K, Adgate JL, Church TR, Ashley DL, Needham LL, Ramachandran G, Fredrickson AL, Ryan AD (2005) Children’s exposure to volatile organic compounds as determined by longitudinal measurements in blood. Environ Health Perspect 113(3):342–349CrossRef
go back to reference Sexton K, Adgate JL, Ramachandran G, Pratt GC, Mongin SJ, Stock TH, Morandi MT (2003) Comparison of personal, indoor, and outdoor exposures to hazardous air pollutants in three urban communities. Environ Sci Technol 38(2):423–430CrossRef Sexton K, Adgate JL, Ramachandran G, Pratt GC, Mongin SJ, Stock TH, Morandi MT (2003) Comparison of personal, indoor, and outdoor exposures to hazardous air pollutants in three urban communities. Environ Sci Technol 38(2):423–430CrossRef
go back to reference Singer BC, Hodgson AT, Hotchi T, Ming KY, Sextro RG, Wood EE, Brown NJ (2007) Sorption of organic gases in residential rooms. Atmos Environ 41(15):3251–3265CrossRef Singer BC, Hodgson AT, Hotchi T, Ming KY, Sextro RG, Wood EE, Brown NJ (2007) Sorption of organic gases in residential rooms. Atmos Environ 41(15):3251–3265CrossRef
go back to reference Tichenor BA, Guo Z (1991) The effect of ventilation on emission rates of wood finishing materials. Environ Int 17(4):317–323CrossRef Tichenor BA, Guo Z (1991) The effect of ventilation on emission rates of wood finishing materials. Environ Int 17(4):317–323CrossRef
go back to reference Tichenor BA, Guo Z, Dorsey JA (1992) Emission rates of mercury from latex paints. U.S Environmental Protection Agency, Washington DC Tichenor BA, Guo Z, Dorsey JA (1992) Emission rates of mercury from latex paints. U.S Environmental Protection Agency, Washington DC
go back to reference Tichenor BA, Guo Z, Dunn JE, Sparkds LE, Mason MA (1991) The interaction of vapour phase organic compounds with indoor sinks. Indoor Air 1:23–37CrossRef Tichenor BA, Guo Z, Dunn JE, Sparkds LE, Mason MA (1991) The interaction of vapour phase organic compounds with indoor sinks. Indoor Air 1:23–37CrossRef
go back to reference Wenger Y, Li D, Jolliet O (2012) Indoor intake fraction considering surface sorption of air organic compounds for life cycle assessment. Int J Life Cycle Assess 17(7):919–931CrossRef Wenger Y, Li D, Jolliet O (2012) Indoor intake fraction considering surface sorption of air organic compounds for life cycle assessment. Int J Life Cycle Assess 17(7):919–931CrossRef
go back to reference WHO (2010) WHO guidelines for indoor air quality: selected pollutants. The WHO European Centre for Environment and Health, Bonn WHO (2010) WHO guidelines for indoor air quality: selected pollutants. The WHO European Centre for Environment and Health, Bonn
Metadata
Title
Integrating human health impact from indoor emissions into an LCA: a case study evaluating the significance of the use stage
Authors
Christofer Skaar
Rikke B. Jørgensen
Publication date
01-03-2013
Publisher
Springer-Verlag
Published in
The International Journal of Life Cycle Assessment / Issue 3/2013
Print ISSN: 0948-3349
Electronic ISSN: 1614-7502
DOI
https://doi.org/10.1007/s11367-012-0506-8

Other articles of this Issue 3/2013

The International Journal of Life Cycle Assessment 3/2013 Go to the issue