Skip to main content
Top
Published in: e & i Elektrotechnik und Informationstechnik 1/2016

18-01-2016 | Originalarbeiten

Intelligent plaster for accurate body temperature monitoring and investigations regarding EMI using near-field magnetic scan

Authors: Carolin Kollegger, Christoph Steffan, Philipp Greiner, Martin Wiessflecker, Gerald Holweg, Bernd Deutschmann

Published in: e+i Elektrotechnik und Informationstechnik | Issue 1/2016

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

A wireless self-sufficient human body temperature monitoring system was designed using a 130 nm CMOS standard process. This miniaturized sensor grain enables significant cost advantages and impresses with its high level of integration. The RFID communication protocol ensures compatibility with state-of-the-art smart phones and tablets, thus facilitating point-of-care as well as end-user utilization. The biocompatible plaster enables cyclic measurements and also storage of the obtained data. In the range of 35 °C to 42 °C a \(\pm3\sigma\) accuracy of ±0.4 °C can be achieved. The system is powered by a lithium based micro battery, which can be recharged wirelessly by any state-of-the-art near field communication device. Measurement data and monitoring history can be displayed via an Android™ software application on a commercial NFC compatible smartphone. The configuration and calibration data as well as the measurement results are stored in the integrated EEPROM. The main advantage of this system appliance is, that it can be easily used within the scope of medical attendance as well as home health care. For the save usage in hospitals additional investigations regarding Electromagnetic Interference using Near-Field Magnetic Scan were performed.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
2.
go back to reference Opasjumruskit, K., Thanthipwan, T., Sathusen, O., Sirinamarattana, P., Gadmanee, P., Pootarapan, E., Wongkomet, N., Thanachayanont, A., Thamsirianunt, M. (2006): Self-powered wireless temperature sensors exploit RFID technology. IEEE Pervasive Comput., 5(1), 54–61. doi:10.1109/MPRV.2006.15. CrossRef Opasjumruskit, K., Thanthipwan, T., Sathusen, O., Sirinamarattana, P., Gadmanee, P., Pootarapan, E., Wongkomet, N., Thanachayanont, A., Thamsirianunt, M. (2006): Self-powered wireless temperature sensors exploit RFID technology. IEEE Pervasive Comput., 5(1), 54–61. doi:10.​1109/​MPRV.​2006.​15. CrossRef
3.
go back to reference Shen, H., Li, L., Zhou, Y. (2007): Fully integrated passive UHF RFID tag with temperature sensor for environment monitoring. In 7th international conference on ASIC, 2007. ASICON ’07 (pp. 360–363). doi:10.1109/ICASIC.2007.4415641. CrossRef Shen, H., Li, L., Zhou, Y. (2007): Fully integrated passive UHF RFID tag with temperature sensor for environment monitoring. In 7th international conference on ASIC, 2007. ASICON ’07 (pp. 360–363). doi:10.​1109/​ICASIC.​2007.​4415641. CrossRef
4.
go back to reference Cecil, S., Bammer, M., Schmid, G., Lamedschwandner, K., Oberleitner, A. (2013): Smart NFC-sensors for healthcare applications and further development trends. E&I, Elektrotech. Inf.tech., 130(7), 191–200. doi:10.1007/s00502-013-0156-y. CrossRef Cecil, S., Bammer, M., Schmid, G., Lamedschwandner, K., Oberleitner, A. (2013): Smart NFC-sensors for healthcare applications and further development trends. E&I, Elektrotech. Inf.tech., 130(7), 191–200. doi:10.​1007/​s00502-013-0156-y. CrossRef
5.
go back to reference Steffan, C. (2013): Konzeption und Entwurf einer integrierten DC/DC Spannungsregelung für On-Chip Ladeschaltungen. Master’s thesis, Graz University of Technology. Steffan, C. (2013): Konzeption und Entwurf einer integrierten DC/DC Spannungsregelung für On-Chip Ladeschaltungen. Master’s thesis, Graz University of Technology.
6.
go back to reference Wiessflecker, M., Hofer, G., Holweg, G., Reinisch, H., Pribyl, W. (2012): A sub 1 V self clocked switched capacitor bandgap reference with a current consumption of 180 nA. In IEEE international symposium on circuits and systems. ISCAS (pp. 2841–2844). doi:10.1109/ISCAS.2012.6271903. Wiessflecker, M., Hofer, G., Holweg, G., Reinisch, H., Pribyl, W. (2012): A sub 1 V self clocked switched capacitor bandgap reference with a current consumption of 180 nA. In IEEE international symposium on circuits and systems. ISCAS (pp. 2841–2844). doi:10.​1109/​ISCAS.​2012.​6271903.
7.
go back to reference Wiessflecker, M. (2013): Design of a generic low voltage, ultra-low power sensor interface for wirelessly powered ICs. PhD thesis, Graz University of Technology. Wiessflecker, M. (2013): Design of a generic low voltage, ultra-low power sensor interface for wirelessly powered ICs. PhD thesis, Graz University of Technology.
8.
go back to reference Cavallini, A., Jost, T., Ghoreishizadeh, S., Olivo, J., de Beeck, M., Gorissen, B., Grassi, F., De Micheli, G., Carrara, S. (2015): A subcutaneous biochip for remote monitoring of human metabolism: packaging and biocompatibility assessment. IEEE Sens. J., 15(1), 417–424. doi:10.1109/JSEN.2014.2339638. CrossRef Cavallini, A., Jost, T., Ghoreishizadeh, S., Olivo, J., de Beeck, M., Gorissen, B., Grassi, F., De Micheli, G., Carrara, S. (2015): A subcutaneous biochip for remote monitoring of human metabolism: packaging and biocompatibility assessment. IEEE Sens. J., 15(1), 417–424. doi:10.​1109/​JSEN.​2014.​2339638. CrossRef
9.
go back to reference Solbrekken, G., Chiu, C.-p (1998): Single temperature calibration method for die level temperature sensors. In The 6th intersociety conference on thermal and thermomechanical phenomena in electronic systems. ITHERM ’98 (pp. 88–95). doi:10.1109/ITHERM.1998.689524. Solbrekken, G., Chiu, C.-p (1998): Single temperature calibration method for die level temperature sensors. In The 6th intersociety conference on thermal and thermomechanical phenomena in electronic systems. ITHERM ’98 (pp. 88–95). doi:10.​1109/​ITHERM.​1998.​689524.
10.
go back to reference DIN EN ISO 80601-2-56 2009 (2009): Medical electrical equipment, part 2: 56 particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement. DIN EN ISO 80601-2-56 2009 (2009): Medical electrical equipment, part 2: 56 particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement.
11.
go back to reference IEC EN 60601-1-2 (2007): Medical electrical equipment, part 1: general requirements for safety.; part 2: collateral standard: electromagnetic compatibility, requirements and tests. IEC EN 60601-1-2 (2007): Medical electrical equipment, part 1: general requirements for safety.; part 2: collateral standard: electromagnetic compatibility, requirements and tests.
12.
go back to reference Council Directive (1993): Medical devices directive 93/42/EEC (as amended by directive 2007/47/EC). Modified by directive 2007/47, 2007. Council Directive (1993): Medical devices directive 93/42/EEC (as amended by directive 2007/47/EC). Modified by directive 2007/47, 2007.
13.
go back to reference Lamedschwandner, K., Preineder, H. (2011): EMV Betrachtung von Nahbereichsfunksystemen. In 9. EMV Fachtagung. OVE Schriftenreihe (Vol. 60, pp. 114–136). Lamedschwandner, K., Preineder, H. (2011): EMV Betrachtung von Nahbereichsfunksystemen. In 9. EMV Fachtagung. OVE Schriftenreihe (Vol. 60, pp. 114–136).
14.
go back to reference ECC (2015): ERC recommendation 70-03 relating to the use of Short Range Devices (SRD). ECC (2015): ERC recommendation 70-03 relating to the use of Short Range Devices (SRD).
Metadata
Title
Intelligent plaster for accurate body temperature monitoring and investigations regarding EMI using near-field magnetic scan
Authors
Carolin Kollegger
Christoph Steffan
Philipp Greiner
Martin Wiessflecker
Gerald Holweg
Bernd Deutschmann
Publication date
18-01-2016
Publisher
Springer Vienna
Published in
e+i Elektrotechnik und Informationstechnik / Issue 1/2016
Print ISSN: 0932-383X
Electronic ISSN: 1613-7620
DOI
https://doi.org/10.1007/s00502-015-0381-7

Other articles of this Issue 1/2016

e & i Elektrotechnik und Informationstechnik 1/2016 Go to the issue