Skip to main content
Top
Published in: Wood Science and Technology 5/2013

01-09-2013 | Original

Methods for determination of duration of surface moisture and presence of water in gaps in wood joints

Authors: Maria Fredriksson, Lars Wadsö, Peter Johansson

Published in: Wood Science and Technology | Issue 5/2013

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

If water stays on wood surfaces or is trapped in gaps, the wood is supplied with water for a long period of time and high local moisture contents are reached. This can lead to decay by rot fungi, and it is therefore important to avoid such water traps in order to limit the decay rate. This paper presents two methods: one for determination of duration of surface moisture on wood surfaces and one for determination of duration of water trapped in gaps in wood joints. Both these methods are based on electrical conductance measurements that are commonly used to measure moisture content of wood. Both sensor types consist of insulating tubing, electrically conductive adhesive and copper wire. The sensors monitor the presence of moisture on the actual material surface, and because of their small size, they do not influence the amount and duration of moisture that stays on the surface or in the gap.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Literature
go back to reference Barthakur NN (1985) A comparative study of radiometric and electronic leaf wetness sensors. Agric For Meteorol 36(1):83–90CrossRef Barthakur NN (1985) A comparative study of radiometric and electronic leaf wetness sensors. Agric For Meteorol 36(1):83–90CrossRef
go back to reference Bernardi A, Becherini F, Bassato G, Bellio M (2006) Condensation on ancient stained glass windows and efficiency of protective glazing systems: two French case studies, Sainte-Chapelle (Paris) and Saint-Urbain Basilica (Troyes). J Cultural Heritage 7(1):71–78CrossRef Bernardi A, Becherini F, Bassato G, Bellio M (2006) Condensation on ancient stained glass windows and efficiency of protective glazing systems: two French case studies, Sainte-Chapelle (Paris) and Saint-Urbain Basilica (Troyes). J Cultural Heritage 7(1):71–78CrossRef
go back to reference Bunnenberg C, Kuhn W (1977) Application of beta-absorption method to measure dew on soil and plant surfaces. Int J Appl Radiat Isot 28(9):751–754CrossRef Bunnenberg C, Kuhn W (1977) Application of beta-absorption method to measure dew on soil and plant surfaces. Int J Appl Radiat Isot 28(9):751–754CrossRef
go back to reference Burkhardt J, Gerchau J (1994) A new device for the study of water-vapor condensation and gaseous deposition to plant-surfaces and particle samples. Atmos Environ 28(12):2012–2017CrossRef Burkhardt J, Gerchau J (1994) A new device for the study of water-vapor condensation and gaseous deposition to plant-surfaces and particle samples. Atmos Environ 28(12):2012–2017CrossRef
go back to reference Cole IS, Holgate R, Kao P, Ganther W (1995) The rate of drying of moisture from a metal surface and its implication for time of wetness. Corros Sci 37(3):455–465CrossRef Cole IS, Holgate R, Kao P, Ganther W (1995) The rate of drying of moisture from a metal surface and its implication for time of wetness. Corros Sci 37(3):455–465CrossRef
go back to reference Davis DR, Hughes JE (1970) A new approach to recording the wetting parameter by the use of electrical resistance sensors. Plant Disease Reporter 54(6):474–479 Davis DR, Hughes JE (1970) A new approach to recording the wetting parameter by the use of electrical resistance sensors. Plant Disease Reporter 54(6):474–479
go back to reference De Groot RC, Highley TL (1995) Forest products laboratory methodology for monitoring decay in wood exposed above ground. In: Proceedings of IRG annual meeting, 1995. IRG/WP 11–40569 De Groot RC, Highley TL (1995) Forest products laboratory methodology for monitoring decay in wood exposed above ground. In: Proceedings of IRG annual meeting, 1995. IRG/WP 11–40569
go back to reference Fattinger C, Togni G, Lukosz W (1987) Wetting in narrow gaps and capillaries: temperature- and surface-pressure-induced wetting transitions. Surf Sci 189(190):405–410CrossRef Fattinger C, Togni G, Lukosz W (1987) Wetting in narrow gaps and capillaries: temperature- and surface-pressure-induced wetting transitions. Surf Sci 189(190):405–410CrossRef
go back to reference Fraigi L, Gwirc SN, Lupi D (1994) A thick-film sensor for atmospheric corrosion testing. Sens Actuators B-Chem 19(1–3):558–561CrossRef Fraigi L, Gwirc SN, Lupi D (1994) A thick-film sensor for atmospheric corrosion testing. Sens Actuators B-Chem 19(1–3):558–561CrossRef
go back to reference Giesler LJ, Horst GL, Yuen GY (1996) A site-specific sensor for measuring leaf wetness duration within turfgrass canopies. Agric For Meteorol 81(1–2):145–156CrossRef Giesler LJ, Horst GL, Yuen GY (1996) A site-specific sensor for measuring leaf wetness duration within turfgrass canopies. Agric For Meteorol 81(1–2):145–156CrossRef
go back to reference Gillespie TJ, Kidd GE (1978) Sensing duration of leaf moisture retention using electrical-impedance grids. Can J Plant Sci 58(1):179–187CrossRef Gillespie TJ, Kidd GE (1978) Sensing duration of leaf moisture retention using electrical-impedance grids. Can J Plant Sci 58(1):179–187CrossRef
go back to reference Griffioen H, Kornet JG, Schurer K (1992) An optical leaf wetness sensor. Acta Horticulturae 304:127–135 Griffioen H, Kornet JG, Schurer K (1992) An optical leaf wetness sensor. Acta Horticulturae 304:127–135
go back to reference Häckel H (1974) Electrical method for measuring wetness duration immediately on leaves. Agric Meteorol 13(1):91–103CrossRef Häckel H (1974) Electrical method for measuring wetness duration immediately on leaves. Agric Meteorol 13(1):91–103CrossRef
go back to reference Häckel H (1980) New developments of an electrical method for direct measurement of the wetness-duration on plants. Agric Meteorol 22(2):113–119CrossRef Häckel H (1980) New developments of an electrical method for direct measurement of the wetness-duration on plants. Agric Meteorol 22(2):113–119CrossRef
go back to reference Heusinkveld BG, Berkowicz SM, Jacobs AFG, Hillen W, Holtslag AAM (2008) A new remote optical wetness sensor and its applications. Agric For Meteorol 148(4):580–591CrossRef Heusinkveld BG, Berkowicz SM, Jacobs AFG, Hillen W, Holtslag AAM (2008) A new remote optical wetness sensor and its applications. Agric For Meteorol 148(4):580–591CrossRef
go back to reference Huber L (1992) Causes of wetness periods and measurement of leaf wetness duration for plant-protection purposes. Agronomie 12(4):281–295CrossRef Huber L (1992) Causes of wetness periods and measurement of leaf wetness duration for plant-protection purposes. Agronomie 12(4):281–295CrossRef
go back to reference Nady M, Said A, Brown WC, Walker IS (1997) Long-term field monitoring of an EIFS clad wall. J Build Phys (Journal of Thermal Insulation and Building Envelopes) 20(4):320–338 Nady M, Said A, Brown WC, Walker IS (1997) Long-term field monitoring of an EIFS clad wall. J Build Phys (Journal of Thermal Insulation and Building Envelopes) 20(4):320–338
go back to reference Norberg P (1999) Monitoring wood moisture content using the WETCORR method. Part 1: background and theoretical considerations. Holz Roh- Werkst 57(6):448–453 Norberg P (1999) Monitoring wood moisture content using the WETCORR method. Part 1: background and theoretical considerations. Holz Roh- Werkst 57(6):448–453
go back to reference Nore K, Thue JV, Rydock JP (2006) A comparison of time-of-wetness and wind-driven rain measurements on wooden cladding. Paper presented at the 5th International conference on cold climate–heating, ventilation and air-conditioning, Moscow, Russia Nore K, Thue JV, Rydock JP (2006) A comparison of time-of-wetness and wind-driven rain measurements on wooden cladding. Paper presented at the 5th International conference on cold climate–heating, ventilation and air-conditioning, Moscow, Russia
go back to reference Schurer K, Van Der Wal AF (1972) An electronic leaf wetness recorder. Neth J Plant Pathol 78(1):29–32CrossRef Schurer K, Van Der Wal AF (1972) An electronic leaf wetness recorder. Neth J Plant Pathol 78(1):29–32CrossRef
go back to reference See RB, Reddy MM, Martin RG (1988) Description and testing of three moisture sensors for measuring surface wetness on carbonate building stones. Rev Sci Instrum 59(10):2279–2284CrossRef See RB, Reddy MM, Martin RG (1988) Description and testing of three moisture sensors for measuring surface wetness on carbonate building stones. Rev Sci Instrum 59(10):2279–2284CrossRef
go back to reference Sereda PJ, Croll SG, Slade HF (1982) Measurement of the time of wetness by moisture sensors and their calibration. Atmos Corros Met ASTM STP 767:267–285CrossRef Sereda PJ, Croll SG, Slade HF (1982) Measurement of the time of wetness by moisture sensors and their calibration. Atmos Corros Met ASTM STP 767:267–285CrossRef
go back to reference Smith CA, Gilpatrick JD (1980) Geneva leaf wetness detector. Plant Dis 64(3):286–288CrossRef Smith CA, Gilpatrick JD (1980) Geneva leaf wetness detector. Plant Dis 64(3):286–288CrossRef
go back to reference Sveipe E, Jelle BP, Wegger E, Uvslokk S, Grynning S, Thue JV, Time B, Gustavsen A (2011) Improving thermal insulation of timber frame walls by retrofitting with vacuum insulation panels—experimental and theoretical investigations. J Build Phys 35(2):168–188CrossRef Sveipe E, Jelle BP, Wegger E, Uvslokk S, Grynning S, Thue JV, Time B, Gustavsen A (2011) Improving thermal insulation of timber frame walls by retrofitting with vacuum insulation panels—experimental and theoretical investigations. J Build Phys 35(2):168–188CrossRef
go back to reference Wallin JR (1963) Dew, its significance and measurement in phytopathology. Phytopathology 53(10):1210–1216 Wallin JR (1963) Dew, its significance and measurement in phytopathology. Phytopathology 53(10):1210–1216
go back to reference Wallin J (1967) Agrometeorological aspects of dew. Agric Meteorol 4(2):85–102CrossRef Wallin J (1967) Agrometeorological aspects of dew. Agric Meteorol 4(2):85–102CrossRef
go back to reference Wei YQ, Bailey BJ, Stenning BC (1995) A wetness sensor for detecting condensation on tomato plants in greenhouses. J Agric Eng Res 61(3):197–204CrossRef Wei YQ, Bailey BJ, Stenning BC (1995) A wetness sensor for detecting condensation on tomato plants in greenhouses. J Agric Eng Res 61(3):197–204CrossRef
go back to reference Weiss A, Lukens DL (1981) Electronic-circuit for detecting leaf wetness and comparison of two sensors. Plant Dis 65(1):41–43CrossRef Weiss A, Lukens DL (1981) Electronic-circuit for detecting leaf wetness and comparison of two sensors. Plant Dis 65(1):41–43CrossRef
go back to reference Weiss A, Lukens DL, Steadman JR (1988) A sensor for the direct measurement of leaf wetness—construction techniques and testing under controlled conditions. Agric For Meteorol 43(3–4):241–249CrossRef Weiss A, Lukens DL, Steadman JR (1988) A sensor for the direct measurement of leaf wetness—construction techniques and testing under controlled conditions. Agric For Meteorol 43(3–4):241–249CrossRef
go back to reference Zlochin I, Seginer I (2001) Fiber-optic leaf-wetness sensor: canopy condensation warning for greenhouses. Acta Horticulturae 562:401–406 Zlochin I, Seginer I (2001) Fiber-optic leaf-wetness sensor: canopy condensation warning for greenhouses. Acta Horticulturae 562:401–406
Metadata
Title
Methods for determination of duration of surface moisture and presence of water in gaps in wood joints
Authors
Maria Fredriksson
Lars Wadsö
Peter Johansson
Publication date
01-09-2013
Publisher
Springer Berlin Heidelberg
Published in
Wood Science and Technology / Issue 5/2013
Print ISSN: 0043-7719
Electronic ISSN: 1432-5225
DOI
https://doi.org/10.1007/s00226-013-0549-4

Other articles of this Issue 5/2013

Wood Science and Technology 5/2013 Go to the issue