Abstract

This paper describes a simple method for fabricating a variable-focus lens using polydimethylsiloxane (PDMS) filling with liquid to produce a variable-focus lens. A 2-mm diameter lens was designed in this experiment, expected to reach a focal length in the range of 3 ∼ 12 mm. The theoretical value between the liquid volume and the lens contact angle at different focal lengths were simulated and measured. The pumped-in liquid volumes ranged from 200 to 1,400 μl. The contact angles ranged from 14.25° to 49.02°. Variable focal length was produced by changing the PDMS film deformation using different micro-fluidic volumes. The focal length produce in the experiment was from 4 ∼ 10 mm. The proposed method successfully fabricated a variable-focus lens. Bonding PDMS only once using no expensive instrument such as oxygen plasma was accomplished. The final objective is to insert the variable focus lens into portable optical imagery products.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
go back to reference Agarwal M, Gunasekaran RA, Coane P, Varahramyan K (2004) Polymer-based variable focal length microlens system. J Micromech Microeng 14:1665–1673CrossRef Agarwal M, Gunasekaran RA, Coane P, Varahramyan K (2004) Polymer-based variable focal length microlens system. J Micromech Microeng 14:1665–1673CrossRef
go back to reference Chen J, Wang W, Fang J, Varahramyan K (2004) Variable-focusing microlens with microfluidic chip. J Micromech Microeng 14:675–680CrossRef Chen J, Wang W, Fang J, Varahramyan K (2004) Variable-focusing microlens with microfluidic chip. J Micromech Microeng 14:675–680CrossRef
go back to reference Chronis N, Liu GL, Jeong KH, Lee LP (2003) Tunable liquid-filled microlens array integrated with microfluidic network. Opt Express 11(19):2370–2378CrossRef Chronis N, Liu GL, Jeong KH, Lee LP (2003) Tunable liquid-filled microlens array integrated with microfluidic network. Opt Express 11(19):2370–2378CrossRef
go back to reference Gunasekaran RA, Agarwal M, Singh A, Dubsi P, Coane P, Varahramyan K (2005) Design and fabrication of fluid controlled dynamic optical lens system. Opt Lasers Eng 43(6):686–703CrossRef Gunasekaran RA, Agarwal M, Singh A, Dubsi P, Coane P, Varahramyan K (2005) Design and fabrication of fluid controlled dynamic optical lens system. Opt Lasers Eng 43(6):686–703CrossRef
go back to reference Hecht E (2002) Optics. University Adelphi, Addison Wesley, CA, pp 262–268 Hecht E (2002) Optics. University Adelphi, Addison Wesley, CA, pp 262–268
go back to reference Jeong KH, Lee LP (2002) A new method of increasing numerical aperture of microlens for biophotonic MEMS. In: 2nd annual international IEEE-EMBS special topic conference on microtechnologies in medicine and biology, pp 380–383 Jeong KH, Lee LP (2002) A new method of increasing numerical aperture of microlens for biophotonic MEMS. In: 2nd annual international IEEE-EMBS special topic conference on microtechnologies in medicine and biology, pp 380–383
go back to reference Jeong KH, Liu GL, Chronis N, Lee LP (2004) Tunable microdoublet lens array. Opt Express 12(11):2494–2500CrossRef Jeong KH, Liu GL, Chronis N, Lee LP (2004) Tunable microdoublet lens array. Opt Express 12(11):2494–2500CrossRef
go back to reference Kuiper S, Hendriks BHW (2004) Variable-focus liquid lens for miniature cameras. Appl Phys Lett 85(7):1128–1130CrossRef Kuiper S, Hendriks BHW (2004) Variable-focus liquid lens for miniature cameras. Appl Phys Lett 85(7):1128–1130CrossRef
go back to reference Ren H, Fan YH, Wu ST (2004a) Polymer network liquid crystals for tunable microlens arrays. J Phys D Appl Phys 37:400–403CrossRef Ren H, Fan YH, Wu ST (2004a) Polymer network liquid crystals for tunable microlens arrays. J Phys D Appl Phys 37:400–403CrossRef
go back to reference Ren H, Fan YH, Gauza S, Wu ST (2004b) Tunable microlens arrays using polymer network liquid crystal. Opt Commun 230(4–6):267–271CrossRef Ren H, Fan YH, Gauza S, Wu ST (2004b) Tunable microlens arrays using polymer network liquid crystal. Opt Commun 230(4–6):267–271CrossRef
go back to reference Ren H, Fan YH, Lin YH, Wu ST (2005) Tunable-focus microlens arrays using nanosized polymer-dispersed liquid crystal droplets. Opt Commun 247(1–3):101–106CrossRef Ren H, Fan YH, Lin YH, Wu ST (2005) Tunable-focus microlens arrays using nanosized polymer-dispersed liquid crystal droplets. Opt Commun 247(1–3):101–106CrossRef
go back to reference Zhang DY, Justis N, Lo YH (2004) Integrated fluidic adaptive zoom lens. Opt Lett 29(24):2855–2857CrossRef Zhang DY, Justis N, Lo YH (2004) Integrated fluidic adaptive zoom lens. Opt Lett 29(24):2855–2857CrossRef
Metadata
Title
Miniaturized variable-focus lens fabrication using liquid filling technique
Authors
Hsiharng Yang
Chung-Yao Yang
Mau-Shiun Yeh
Publication date
01-07-2008
Publisher
Springer-Verlag
Published in
Microsystem Technologies / Issue 7/2008
Print ISSN: 0946-7076
Electronic ISSN: 1432-1858
DOI
https://doi.org/10.1007/s00542-007-0524-9

Other articles of this Issue 7/2008

Microsystem Technologies 7/2008 Go to the issue