10. Modeling and Control Strategies for VAV Systems

Authors : Ye Yao, Yuebin Yu

Published in: Modeling and Control in Air-conditioning Systems

Publisher: Springer Berlin Heidelberg

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

In a heating, ventilating, and air-conditioning (HVAC) system, operation of the air-side system has a significant influence on the overall performance of a building energy system. For example, in a worst-case scenario instability in the air-side economizer could trigger instability at the central chilled water plant or vice versa.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Urban, R.A.: Design considerations and operating characteristics of variable volume systems. ASHRAE J. 12(2), 77–84 (1969) Urban, R.A.: Design considerations and operating characteristics of variable volume systems. ASHRAE J. 12(2), 77–84 (1969)
2.
go back to reference Shepherd, K.: VAV Air Conditioning Systems. Blackwell Science Ltd, United Kingdom (1999) Shepherd, K.: VAV Air Conditioning Systems. Blackwell Science Ltd, United Kingdom (1999)
3.
go back to reference ASHRAE Handbook. HVAC Systems and Equipment [Chapter 4]. In Air Handling and Distribution. American Society of Heating, Refrigerating and Air conditioning Engineers Inc, Atlanta (2008) (4.11) ASHRAE Handbook. HVAC Systems and Equipment [Chapter 4]. In Air Handling and Distribution. American Society of Heating, Refrigerating and Air conditioning Engineers Inc, Atlanta (2008) (4.11)
4.
go back to reference Dodd, M.: Comparing Energy Savings of Different VAV Systems, pp. 1–9. EnergySoft LLC (2012) Dodd, M.: Comparing Energy Savings of Different VAV Systems, pp. 1–9. EnergySoft LLC (2012)
5.
go back to reference Bearg, D.W.: Indoor Air Quality and HVAC Systems. Lewis Publishers (1993) Bearg, D.W.: Indoor Air Quality and HVAC Systems. Lewis Publishers (1993)
6.
go back to reference Engdahl, F., Johansson, D.: Optimal supply air temperature with respect to energy use in a variable air volume system. J. Energy Build. 36, 205–218 (2004)CrossRef Engdahl, F., Johansson, D.: Optimal supply air temperature with respect to energy use in a variable air volume system. J. Energy Build. 36, 205–218 (2004)CrossRef
7.
go back to reference Tung, D., Deng, S.: Variable air volume system under reduced static pressure control. Build. Serv. Eng. Res. Technol. 18(2), 77–83 (1997)CrossRef Tung, D., Deng, S.: Variable air volume system under reduced static pressure control. Build. Serv. Eng. Res. Technol. 18(2), 77–83 (1997)CrossRef
8.
go back to reference Inoue, U., Matsumoto, T.: A study on energy savings with variable air volume systems by simulation and field measurement. J. Energy Build. 2, 27–36 (1979)CrossRef Inoue, U., Matsumoto, T.: A study on energy savings with variable air volume systems by simulation and field measurement. J. Energy Build. 2, 27–36 (1979)CrossRef
9.
go back to reference Kloostra, L.: VAV systems save 38 % of energy use. Heating Pip. Air Conditioning 51(12), 61–63 (1979) Kloostra, L.: VAV systems save 38 % of energy use. Heating Pip. Air Conditioning 51(12), 61–63 (1979)
10.
go back to reference Mull, T.E.: Energy conservation measures for air distribution and HVAC systems. J. Plant Eng. 58(10), 60–64 (2004) Mull, T.E.: Energy conservation measures for air distribution and HVAC systems. J. Plant Eng. 58(10), 60–64 (2004)
11.
go back to reference Mysen, M., Rydock, I.P., Tjelflaat, P.O.: Demand controlled ventilation for office cubicles-can it be profitable? J. Energy Build. 35, 657–662 (2003)CrossRef Mysen, M., Rydock, I.P., Tjelflaat, P.O.: Demand controlled ventilation for office cubicles-can it be profitable? J. Energy Build. 35, 657–662 (2003)CrossRef
12.
go back to reference Norford, L.K., Rabl, A., Socolow, R.H.: Control of supply air temperature and outdoor airflow and its effect on energy use in a variable air volume system. ASHRAE Trans. 92, 30–45 (1986) Norford, L.K., Rabl, A., Socolow, R.H.: Control of supply air temperature and outdoor airflow and its effect on energy use in a variable air volume system. ASHRAE Trans. 92, 30–45 (1986)
13.
go back to reference Wang, S., Burnett, J.: Variable-air-volume air-conditioning systems: optimized static pressure setpoint. J. Build. Serv. Eng. Res. Technol. 19(4), 219–231 (1998)CrossRef Wang, S., Burnett, J.: Variable-air-volume air-conditioning systems: optimized static pressure setpoint. J. Build. Serv. Eng. Res. Technol. 19(4), 219–231 (1998)CrossRef
14.
go back to reference Khoo, I., Levermore, G.J., Letherman, K.M.: Variable-air-volume terminal units I: steady state models. J. Build. Serv. Eng. Res. Technol. 19(3), 155–162 (1998)CrossRef Khoo, I., Levermore, G.J., Letherman, K.M.: Variable-air-volume terminal units I: steady state models. J. Build. Serv. Eng. Res. Technol. 19(3), 155–162 (1998)CrossRef
15.
go back to reference Parameshwaran, R., Karunakaran, R., Iniyan, S., Anand, A.S.: Optimization of energy conservation potential for VAV air conditioning system using Fuzzy based genetic algorithm. Int. J. Mech. Aerosp. Ind. Mechatron. Manuf. Eng. 2(1), 67–74 (2008) Parameshwaran, R., Karunakaran, R., Iniyan, S., Anand, A.S.: Optimization of energy conservation potential for VAV air conditioning system using Fuzzy based genetic algorithm. Int. J. Mech. Aerosp. Ind. Mechatron. Manuf. Eng. 2(1), 67–74 (2008)
16.
go back to reference ANSI/ASHRAE/IESNA. Standard 90.1-2010 Energy standard for buildings except low-rise residential buildings. International Code Council, Inc., Washington, D.C. and American Society of Heating, Refrigerating and Air-conditioning Engineers, Inc., Atlanta, GA (2010) ANSI/ASHRAE/IESNA. Standard 90.1-2010 Energy standard for buildings except low-rise residential buildings. International Code Council, Inc., Washington, D.C. and American Society of Heating, Refrigerating and Air-conditioning Engineers, Inc., Atlanta, GA (2010)
17.
go back to reference Yu, Y., Liu, M., Cho, Y., Xu, K.: Integrated demand controlled ventilation for single duct VAV system with conference rooms. In: Proceedings of ICEBO, California (2007) Yu, Y., Liu, M., Cho, Y., Xu, K.: Integrated demand controlled ventilation for single duct VAV system with conference rooms. In: Proceedings of ICEBO, California (2007)
18.
go back to reference Yu, Y., Xu, K., Cho, Y.H., Liu, M.: A smart logic for conference room terminal box of single duct VAV system. In: Proceedings of the 7th International Conference for Enhanced Building Operations. San Francisco, CA (2007) Yu, Y., Xu, K., Cho, Y.H., Liu, M.: A smart logic for conference room terminal box of single duct VAV system. In: Proceedings of the 7th International Conference for Enhanced Building Operations. San Francisco, CA (2007)
19.
go back to reference Cho, Y.H.: Development of a terminal control system with variable minimum airflow rate. Energies 5, 4643–4664 (2012)CrossRef Cho, Y.H.: Development of a terminal control system with variable minimum airflow rate. Energies 5, 4643–4664 (2012)CrossRef
20.
go back to reference Hartman, T.: TRAV—A new HVAC concept. Heating/Piping/Air Conditioning Eng. HPAC 61(7), 69–73 (1989) Hartman, T.: TRAV—A new HVAC concept. Heating/Piping/Air Conditioning Eng. HPAC 61(7), 69–73 (1989)
21.
go back to reference Hartman, T.: Terminal regulated air volume (TRAV) systems. ASHRAE Trans. 99(1), 791–800 (1993) Hartman, T.: Terminal regulated air volume (TRAV) systems. ASHRAE Trans. 99(1), 791–800 (1993)
22.
go back to reference Hartman, T.: Global optimization strategies for high-performance controls. ASHRAE Trans. 101(2), 679–687 (1995) Hartman, T.: Global optimization strategies for high-performance controls. ASHRAE Trans. 101(2), 679–687 (1995)
23.
go back to reference Englander S.: Ventilation Control for Energy Conservation: Digitally Controlled Terminal Boxes and Variable Speed Drives. Princeton University (1990) Englander S.: Ventilation Control for Energy Conservation: Digitally Controlled Terminal Boxes and Variable Speed Drives. Princeton University (1990)
24.
go back to reference Englander, S.L., Norford, L.K.: Saving fan energy in VAV systems—Part 2: supply fan control for static pressure minimization using DDC zone feedback. ASHRAE Trans. 98(1), 19–32 (1992) Englander, S.L., Norford, L.K.: Saving fan energy in VAV systems—Part 2: supply fan control for static pressure minimization using DDC zone feedback. ASHRAE Trans. 98(1), 19–32 (1992)
25.
go back to reference Warren, M., Norford, L.K.: Integrating VAV zone requirements with supply fan operation. ASHRAE J. 35(4), 43–46 (1993) Warren, M., Norford, L.K.: Integrating VAV zone requirements with supply fan operation. ASHRAE J. 35(4), 43–46 (1993)
26.
go back to reference Wei, G.H., Liu, M.S., Claridge, D.E., Sakurai, Y.: Improved air volume control logic for VAV systems. In: Proceedings of the Twelfth Symposium on Improving Building Systems in Hot and Humid Climates. San Antonio, TX, May 15–17 (2000) Wei, G.H., Liu, M.S., Claridge, D.E., Sakurai, Y.: Improved air volume control logic for VAV systems. In: Proceedings of the Twelfth Symposium on Improving Building Systems in Hot and Humid Climates. San Antonio, TX, May 15–17 (2000)
27.
go back to reference Nassif, N., Moujaes, S.: A new operating strategy for economizer dampers of VAV system. J. Energy Build. 40, 289–299 (2008)CrossRef Nassif, N., Moujaes, S.: A new operating strategy for economizer dampers of VAV system. J. Energy Build. 40, 289–299 (2008)CrossRef
29.
31.
go back to reference Liu, M.: Variable speed drive volumetric tracking (VSDVT) for airflow control in variable air volume (VAV) systems. J. Sol. Energy Eng. 125, 318–323 (2003)CrossRef Liu, M.: Variable speed drive volumetric tracking (VSDVT) for airflow control in variable air volume (VAV) systems. J. Sol. Energy Eng. 125, 318–323 (2003)CrossRef
32.
go back to reference Liu, G., Liu, M.: Supply fan control methods for VAV systems using a fan airflow station. ASHRAE Trans. 114(2), 451–457 (2008) Liu, G., Liu, M.: Supply fan control methods for VAV systems using a fan airflow station. ASHRAE Trans. 114(2), 451–457 (2008)
33.
go back to reference Wu, L., Liu, M., Wang, G., Pang, X.: Integrated static pressure reset with fan airflow station in dual-duct VAV system control. In: Proceedings of the Energy Sustainability Conference 2007, pp. 441–49. Long Beach, CA (2007) Wu, L., Liu, M., Wang, G., Pang, X.: Integrated static pressure reset with fan airflow station in dual-duct VAV system control. In: Proceedings of the Energy Sustainability Conference 2007, pp. 441–49. Long Beach, CA (2007)
35.
go back to reference Zheng, K., Li, H., Yang, H.: Application of wireless sensor network (WSN) technologies in optimal static pressure reset in variable air volume (VAV) system. In: Proceedings of the 7th International Conference for Enhanced Building Operations. SanFrancisco, CA (2007). http://esl.eslwin.tamu.edu/digital-library.html Zheng, K., Li, H., Yang, H.: Application of wireless sensor network (WSN) technologies in optimal static pressure reset in variable air volume (VAV) system. In: Proceedings of the 7th International Conference for Enhanced Building Operations. SanFrancisco, CA (2007). http://​esl.​eslwin.​tamu.​edu/​digital-library.​html
36.
go back to reference Murphy, J.: Ventilation control in terminal units with variable speed fan control. ASHRAE J., 12–19 (2013) Murphy, J.: Ventilation control in terminal units with variable speed fan control. ASHRAE J., 12–19 (2013)
37.
go back to reference Meng, Q.L., Yan, X.Y., Ren, Q.C.: Global optimal control of VAV air-conditioning system with iterative learning: an experimental case study. J. Zhejiang Univ.-Sci. A (ApplPhys&Eng), 1–21 (2014) Meng, Q.L., Yan, X.Y., Ren, Q.C.: Global optimal control of VAV air-conditioning system with iterative learning: an experimental case study. J. Zhejiang Univ.-Sci. A (ApplPhys&Eng), 1–21 (2014)
38.
go back to reference Koulani, C.S.: Optimized damper control of pressure and airflow in ventilation systems. Section of building physics and services department of civil engineering, Technical University of Denmark. Master thesis (2013) Koulani, C.S.: Optimized damper control of pressure and airflow in ventilation systems. Section of building physics and services department of civil engineering, Technical University of Denmark. Master thesis (2013)
41.
go back to reference Zheng, G.R.: Dynamic modeling and global optimal operation of multi-zone variable air volume HVAC system. PHD Thesis, The Center for Building Studies, Concordia University, Montreal, Canada (1997) Zheng, G.R.: Dynamic modeling and global optimal operation of multi-zone variable air volume HVAC system. PHD Thesis, The Center for Building Studies, Concordia University, Montreal, Canada (1997)
42.
go back to reference White, F.M.: Fluid Mechanics, 3rd edn, p. 736. Mc-Graw Hill, New York (1994) White, F.M.: Fluid Mechanics, 3rd edn, p. 736. Mc-Graw Hill, New York (1994)
43.
go back to reference Brandemuel, M.J., Gabell, S., Andersen, I.: A Toolkit for Secondary HVAC System Energy Calculation. ASHRAE, Joint Center for Energy Management, University of Colorado, Boulder (1993) Brandemuel, M.J., Gabell, S., Andersen, I.: A Toolkit for Secondary HVAC System Energy Calculation. ASHRAE, Joint Center for Energy Management, University of Colorado, Boulder (1993)
44.
go back to reference Nassif, N.S., Kajl, S., Sabourin, R.: Modeling and validation of existing VAV system components. In: Proceedings of Esim, Canadian Conference on Building Simulation, Vancouver, Canada (2004) Nassif, N.S., Kajl, S., Sabourin, R.: Modeling and validation of existing VAV system components. In: Proceedings of Esim, Canadian Conference on Building Simulation, Vancouver, Canada (2004)
45.
go back to reference Fans and Pumps. Energy Management Series 13 for Industry and Commercial Institutions, Canada Fans and Pumps. Energy Management Series 13 for Industry and Commercial Institutions, Canada
46.
go back to reference Colebrook, C.F.: Turbulent flow in the pipe, with particular reference to the transition region between the smooth and rough pipe laws. J. Inst. Civ. Eng. 11, 133–156 (1938–1939) (London) Colebrook, C.F.: Turbulent flow in the pipe, with particular reference to the transition region between the smooth and rough pipe laws. J. Inst. Civ. Eng. 11, 133–156 (1938–1939) (London)
47.
go back to reference Haaland, S.: Simple and explicit formulas for the friction factor in turbulent flow. Trans. ASME J. Fluids Eng. 103, 89–90 (1983)CrossRef Haaland, S.: Simple and explicit formulas for the friction factor in turbulent flow. Trans. ASME J. Fluids Eng. 103, 89–90 (1983)CrossRef
48.
go back to reference McQuiston, F.C., Parker, J.D.: Heating, Ventilating and Air-Conditioning, 3rd edn. Wiley, Hoboken (1988) McQuiston, F.C., Parker, J.D.: Heating, Ventilating and Air-Conditioning, 3rd edn. Wiley, Hoboken (1988)
49.
go back to reference Idelchik, I.E.: Handbook of Hydraulic Resistance. Hemisphere Publishing Corporation (1986) Idelchik, I.E.: Handbook of Hydraulic Resistance. Hemisphere Publishing Corporation (1986)
50.
go back to reference Archer, W.H.: Loss of head due to enlargements in pipes. Trans. Am. Soc. Civ. Eng. 76, 999–1026 (1913) Archer, W.H.: Loss of head due to enlargements in pipes. Trans. Am. Soc. Civ. Eng. 76, 999–1026 (1913)
51.
go back to reference ASHRAE. HVAC Fundamentals. ASHRAE Handbook (2011) ASHRAE. HVAC Fundamentals. ASHRAE Handbook (2011)
52.
go back to reference ANSI/ASHRAE/IESNA Standard 90.1-2010. Energy standard for buildings except low-rise residential buildings. American Society of Heating, Refrigerating and Air-conditioning Engineers, Inc, Atlanta (2010) ANSI/ASHRAE/IESNA Standard 90.1-2010. Energy standard for buildings except low-rise residential buildings. American Society of Heating, Refrigerating and Air-conditioning Engineers, Inc, Atlanta (2010)
53.
go back to reference Yuying, S., Zheng, Z., Hou, X., Tian, P.: AHU control strategies in the VAV system. In: Fourth International Conference on Innovative Computing, Information and Control, pp. 119–123 (2009) Yuying, S., Zheng, Z., Hou, X., Tian, P.: AHU control strategies in the VAV system. In: Fourth International Conference on Innovative Computing, Information and Control, pp. 119–123 (2009)
54.
go back to reference Nelson, R.M., Householder, B.: A study on static pressure reset and instability in variable air volume HVAC systems. Final report, Iowa Energy Center (2011) Nelson, R.M., Householder, B.: A study on static pressure reset and instability in variable air volume HVAC systems. Final report, Iowa Energy Center (2011)
55.
go back to reference Taylor, S.: Resetting set points using trim and respond logic. ASHRAE J., 52–57 (2015) Taylor, S.: Resetting set points using trim and respond logic. ASHRAE J., 52–57 (2015)
56.
go back to reference Taylor, S.: Increasing efficiency with VAV system static pressure setpoint reset. ASHRAE J. 49(6), 24–32 (2007) Taylor, S.: Increasing efficiency with VAV system static pressure setpoint reset. ASHRAE J. 49(6), 24–32 (2007)
Metadata
Title
Modeling and Control Strategies for VAV Systems
Authors
Ye Yao
Yuebin Yu
Copyright Year
2017
Publisher
Springer Berlin Heidelberg
DOI
https://doi.org/10.1007/978-3-662-53313-0_10