Abstract

CT is a mandatory imaging modality for radiation treatment planning (RTP) while MRI and PET have advantages in tumor delineation and dose prescriptions. To avoid multiple scanning and additional high radiation doses, this paper proposes to integrate low dose transmission scan (TX) into a PET/MRI machine for the synthesis of virtual CT (VCT) for treatment planning. TX is usually extremely noisy with artifact spots and it is necessary to smooth the sinogram to obtain interpretable images. However this results in blurred low resolution images. This study introduces a novel joint-anisotropic diffusion (JAD) method which restores VCT images without loss of resolution using additional anatomical images to regularize the filtering. Through reshaping the anisotropic diffusion tensor using MRI, this method guides the diffusion flux to favor the similarity between VCT and MRI leading to an increase of mutual information. For proof of concept, virtual PET/MRI/VCT system with conventional \(^{68}\)Ga ring source was implemented on GATE and realistic TX data were simulated and tested. The results demonstrate that the new approach improves the geometrical accuracy of VCT and provides a potential application for RTP.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Judenhofer, M.S., Wehrl, H.F., Newport, D.F., Catana, C., Siegel, S.B., Becker, M., Thielscher, A., Kneilling, M., Lichy, M.P., Eichner, M., Klingel, K., Reischl, G., Widmaier, S., Röcken, M., Nutt, R.E., Machulla, H.J., Uludag, K., Cherry, S.R., Claussen, C.D., Pichler, B.J.: Simultaneous PET-MRI: a new approach for functional and morphological imaging. Nat. Med. 14, 459–465 (2008)CrossRef Judenhofer, M.S., Wehrl, H.F., Newport, D.F., Catana, C., Siegel, S.B., Becker, M., Thielscher, A., Kneilling, M., Lichy, M.P., Eichner, M., Klingel, K., Reischl, G., Widmaier, S., Röcken, M., Nutt, R.E., Machulla, H.J., Uludag, K., Cherry, S.R., Claussen, C.D., Pichler, B.J.: Simultaneous PET-MRI: a new approach for functional and morphological imaging. Nat. Med. 14, 459–465 (2008)CrossRef
2.
go back to reference Pedemonte, S., Bousse, A., Hutton, B.F., Arridge, S.R., Ourselin, S.: 4-D generative model for PET/MRI reconstruction. MICCAI 6891(1), 581–588 (2011) Pedemonte, S., Bousse, A., Hutton, B.F., Arridge, S.R., Ourselin, S.: 4-D generative model for PET/MRI reconstruction. MICCAI 6891(1), 581–588 (2011)
3.
go back to reference Risholm, P., Balter, J., Wells III, W.M.: Estimation of delivered dose in radiotherapy: the influence of registration uncertainty. MICCAI 6891(1), 548–555 (2011) Risholm, P., Balter, J., Wells III, W.M.: Estimation of delivered dose in radiotherapy: the influence of registration uncertainty. MICCAI 6891(1), 548–555 (2011)
4.
go back to reference Stanescu, T., Jans, H.S., Pervez, N., Stavrev, P., Fallone, B.G.: A study on the magnetic resonance imaging (MRI)-based radiation treatment planning of intracranial lesions. Phys. Med. Biol. 53(13), 3579–3593 (2008)CrossRef Stanescu, T., Jans, H.S., Pervez, N., Stavrev, P., Fallone, B.G.: A study on the magnetic resonance imaging (MRI)-based radiation treatment planning of intracranial lesions. Phys. Med. Biol. 53(13), 3579–3593 (2008)CrossRef
5.
go back to reference Jonsson, J., Karlsson, M., Karlsson, M., Nyholm, T.: Treatment planning using MRI data: an analysis of the dose calculation accuracy for different treatment regions. Radiat. Oncol. 5(1), 62–69 (2010)CrossRef Jonsson, J., Karlsson, M., Karlsson, M., Nyholm, T.: Treatment planning using MRI data: an analysis of the dose calculation accuracy for different treatment regions. Radiat. Oncol. 5(1), 62–69 (2010)CrossRef
6.
go back to reference Bailey, D.L., Townsend, D.W., Valk, P.E., Maisey, M.N.: Positron Emission Tomography: Basic Sciences. Springer, New York (2004) Bailey, D.L., Townsend, D.W., Valk, P.E., Maisey, M.N.: Positron Emission Tomography: Basic Sciences. Springer, New York (2004)
7.
go back to reference Almeida, P., Bendriem, B., de Dreuille, O., Peltier, A., Perrot, C., Brulon, V.: Dosimetry of transmission measurements in nuclear medicine: a study using anthropomorphic phantoms and thermoluminescent dosimeters. Eur. J. Nucl. Med. 25, 1435–1441 (1998)CrossRef Almeida, P., Bendriem, B., de Dreuille, O., Peltier, A., Perrot, C., Brulon, V.: Dosimetry of transmission measurements in nuclear medicine: a study using anthropomorphic phantoms and thermoluminescent dosimeters. Eur. J. Nucl. Med. 25, 1435–1441 (1998)CrossRef
8.
go back to reference Martinez-Möller, A., Souvatzoglou, M., Delso, G., Bundschuh, R.A., Chefd’hotel, C., Ziegler, S.I., Navab, N., Schwaiger, M., Nekolla, S.G.: Tissue classification as a potential approach for attenuation correction in whole-body PET/MRI: evaluation with PET/CT data. J. Nucl. Med. 50(4), 520–526 (2009)CrossRef Martinez-Möller, A., Souvatzoglou, M., Delso, G., Bundschuh, R.A., Chefd’hotel, C., Ziegler, S.I., Navab, N., Schwaiger, M., Nekolla, S.G.: Tissue classification as a potential approach for attenuation correction in whole-body PET/MRI: evaluation with PET/CT data. J. Nucl. Med. 50(4), 520–526 (2009)CrossRef
9.
go back to reference Santin, G., Strul, D., Lazaro, D., Simon, L., Krieguer, M., Martins, M., Breton, V., Morel, C.: GATE: a Geant4-based simulation platform for PET and SPECT integrating movement and time management. IEEE Trans. Nucl. Sci. 50(5), 1516–1521 (2003)CrossRef Santin, G., Strul, D., Lazaro, D., Simon, L., Krieguer, M., Martins, M., Breton, V., Morel, C.: GATE: a Geant4-based simulation platform for PET and SPECT integrating movement and time management. IEEE Trans. Nucl. Sci. 50(5), 1516–1521 (2003)CrossRef
10.
go back to reference Weickert, J.: Anisotropic Diffusion in Image Processing. Teuber Verlag, Stuttgart (1998)MATH Weickert, J.: Anisotropic Diffusion in Image Processing. Teuber Verlag, Stuttgart (1998)MATH
11.
go back to reference Burger, C., Goerres, G., Schoenes, S., Buck, A., Lonn, A., von Schulthess, G.: PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients. Eur. J. Nucl. Med. Mol. Imaging 29, 922–927 (2002)CrossRef Burger, C., Goerres, G., Schoenes, S., Buck, A., Lonn, A., von Schulthess, G.: PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients. Eur. J. Nucl. Med. Mol. Imaging 29, 922–927 (2002)CrossRef
12.
go back to reference Delso, G., Fürst, S., Jakoby, B., Ladebeck, R., Ganter, C., Nekolla, S.G., Schwaiger, M., Ziegler, S.I.: Performance measurements of the Siemens mMR integrated whole-body PET/MR scanner. J. Nucl. Med. 52(12), 1914–1922 (2011)CrossRef Delso, G., Fürst, S., Jakoby, B., Ladebeck, R., Ganter, C., Nekolla, S.G., Schwaiger, M., Ziegler, S.I.: Performance measurements of the Siemens mMR integrated whole-body PET/MR scanner. J. Nucl. Med. 52(12), 1914–1922 (2011)CrossRef
13.
go back to reference Hofmann, M., Steinke, F., Scheel, V., Charpiat, G, Farquhar, J., Aschoff, P., Brady, M., Schölkopf, B., Pichler, B.J.: MRI-based attenuation correction for PET/MRI: a novel approach combining pattern recognition and atlas registration. J. Nucl. Med. 49(11), 1875–1883 (2008)CrossRef Hofmann, M., Steinke, F., Scheel, V., Charpiat, G, Farquhar, J., Aschoff, P., Brady, M., Schölkopf, B., Pichler, B.J.: MRI-based attenuation correction for PET/MRI: a novel approach combining pattern recognition and atlas registration. J. Nucl. Med. 49(11), 1875–1883 (2008)CrossRef
Metadata
Title
PET/MRI/VCT: Restoration of Virtual CT from Transmission Scan on PET/MRI Using Joint-Anisotropic Diffusion
Authors
Kuangyu Shi
Xiaoyin Cheng
Nassir Navab
Stefan Foerster
Sibylle I. Ziegler
Copyright Year
2015
DOI
https://doi.org/10.1007/978-3-319-18431-9_3