Skip to main content
Top

2011 | OriginalPaper | Chapter

41. Pharmaceutical Aerosol Sprays for Drug Delivery to the Lungs

Author : W. H. Finlay

Published in: Handbook of Atomization and Sprays

Publisher: Springer US

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Respiratory illnesses are commonly treated with drugs delivered to the lungs as an inhaled aerosol. The inhaled aerosol route sometimes offers advantages over other routes such as injection or oral delivery. These advantages include rapid and predictable onset of action of drug, decreased adverse reactions, as well as safe and convenient delivery. However, the design of a device and formulation for reliable delivery of a pharmaceutical compound as an inhaled aerosol is more difficult than most other delivery routes. This is because of the need to transform the active ingredient into an aerosol having particle sizes of a few micrometers in diameter that is then supplied to the patient’s mouth upon inhalation. Devices that can create sprays with particles in the micrometer size range, but which remain portable, inexpensive to manufacture, easy to use by patients, and are robust enough to withstand patient use, are relatively few in design. Indeed, at present only four basic spray production mechanisms are currently in use on the clinical market for drug delivery to the lungs: pressurized release of a volatile propellant, colliding liquid jets, air-blast atomization and high frequency vibration methods. While other methods have undergone development (e.g., Rayleigh breakup of an extruded liquid jet [1]; high voltage electrosprays [2]), they have not yet reached market release. In the following we consider the four clinically available methods.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Ward, M. E., Woodhouse, A., Mather, L. E., Farr, S. J., Okikawa, J. K., Lloyd, P., Schuster, J. A., and Rubsamen, R. M. 1997. Morphine pharmacokinetics after pulmonary administration from a novel aerosol delivery system, Clin. Pharm. Ther. 62:596–609.CrossRef Ward, M. E., Woodhouse, A., Mather, L. E., Farr, S. J., Okikawa, J. K., Lloyd, P., Schuster, J. A., and Rubsamen, R. M. 1997. Morphine pharmacokinetics after pulmonary administration from a novel aerosol delivery system, Clin. Pharm. Ther. 62:596–609.CrossRef
2.
go back to reference Meesters, G. M. H., Vercoulen, P. H. W., Marijnissen, J. C. M., and Scarlett, B. 1992. Generation of micron-sized droplets from the Taylor cone, J. Aerosol Sci. 23:37–49.CrossRef Meesters, G. M. H., Vercoulen, P. H. W., Marijnissen, J. C. M., and Scarlett, B. 1992. Generation of micron-sized droplets from the Taylor cone, J. Aerosol Sci. 23:37–49.CrossRef
3.
go back to reference Finlay, W. H. 2001. Mechanics of Inhaled Pharmaceutical Aerosols: An Introduction. Academic. London Finlay, W. H. 2001. Mechanics of Inhaled Pharmaceutical Aerosols: An Introduction. Academic. London
4.
go back to reference Versteeg, H. K., Hargrave, G. K., and Kirby, M. 2006. Internal flow and near-orifice spray visualisation of a model pharmaceutical pressurized metered dose inhaler, J. Phys. (Conf. Ser.) 45:207–213.CrossRef Versteeg, H. K., Hargrave, G. K., and Kirby, M. 2006. Internal flow and near-orifice spray visualisation of a model pharmaceutical pressurized metered dose inhaler, J. Phys. (Conf. Ser.) 45:207–213.CrossRef
5.
go back to reference Crosland, B. M., Johnson, M. R. J., and Matida, E. A. 2009. Characterization of the spray velocities from a pressurized metered-dose inhaler, J. Aerosol Med. Pulm. Drug. Del. 22:85097. Crosland, B. M., Johnson, M. R. J., and Matida, E. A. 2009. Characterization of the spray velocities from a pressurized metered-dose inhaler, J. Aerosol Med. Pulm. Drug. Del. 22:85097.
6.
go back to reference Dunbar, C. A., Watkins, A. P., and Miller, J. F. 1997. An experimental investigation of the spray issued from a pMDI using laser diagnostic techniques, J. Aerosol Med. 10:351–268.CrossRef Dunbar, C. A., Watkins, A. P., and Miller, J. F. 1997. An experimental investigation of the spray issued from a pMDI using laser diagnostic techniques, J. Aerosol Med. 10:351–268.CrossRef
7.
go back to reference Clark, A. R. 1996. MDIs: physics of aerosol formation, J. Aerosol Med. 9S:19–26. Clark, A. R. 1996. MDIs: physics of aerosol formation, J. Aerosol Med. 9S:19–26.
8.
go back to reference Kleinstreuer, C., Shi, H., and Zhang, Z. 2006. Computational analyses of a pressurized metered dose inhaler and a new drug-aerosol targeting methodology, J. Aerosol Med. 20:294–309.CrossRef Kleinstreuer, C., Shi, H., and Zhang, Z. 2006. Computational analyses of a pressurized metered dose inhaler and a new drug-aerosol targeting methodology, J. Aerosol Med. 20:294–309.CrossRef
9.
go back to reference Martin, A. R. and Finlay, W. H. The effect of humidity on particle sizing from metered-dose inhalers, Aerosol Sci. Technol. 39:283–289, 2005. Martin, A. R. and Finlay, W. H. The effect of humidity on particle sizing from metered-dose inhalers, Aerosol Sci. Technol. 39:283–289, 2005.
10.
go back to reference Domnick, J. and Durst, F. 1995. Measurement of bubble size, velocity and concentration in flashing flow behind a sudden constriction, Int. J. Multiphase Flow 21:1047–1062.MATHCrossRef Domnick, J. and Durst, F. 1995. Measurement of bubble size, velocity and concentration in flashing flow behind a sudden constriction, Int. J. Multiphase Flow 21:1047–1062.MATHCrossRef
11.
go back to reference Dunbar, C. A., Watkins, A. P., and Miller, J. F. 1997. Theoretical investigation of the spray from a metered-dose inhaler. Atom. Sprays 7:417–436. Dunbar, C. A., Watkins, A. P., and Miller, J. F. 1997. Theoretical investigation of the spray from a metered-dose inhaler. Atom. Sprays 7:417–436.
12.
go back to reference Zierenberg, B., Eicher, J., Dunne, S., and Freund, B. 1996. Boehringer Ingelheim nebulizer BINEB a new approach to inhalation therapy. In R. N. Dalby, P. R. Byron, and S. J. Farr, eds., Proceedings of Respiratory Drug Delivery V. Interpharm Press, Buffalo Grove, pp. 187–193. Zierenberg, B., Eicher, J., Dunne, S., and Freund, B. 1996. Boehringer Ingelheim nebulizer BINEB a new approach to inhalation therapy. In R. N. Dalby, P. R. Byron, and S. J. Farr, eds., Proceedings of Respiratory Drug Delivery V. Interpharm Press, Buffalo Grove, pp. 187–193.
13.
go back to reference Bartels, F., Bachtler, W., Dunne, S. T., Eicher, J., Freund, B., Hart, W. B., and Lessmoellmann, C. 1999. Atomizing nozzle and filter and spray generating device, US Patent 6007676. Bartels, F., Bachtler, W., Dunne, S. T., Eicher, J., Freund, B., Hart, W. B., and Lessmoellmann, C. 1999. Atomizing nozzle and filter and spray generating device, US Patent 6007676.
14.
go back to reference Jaeger, J., Cirillo, P., Eicher, J., Geser, J., Freund, B., and Zierenberg, B. 2005. Device for producing high pressure in a fluid in miniature, US patent 69185467. Jaeger, J., Cirillo, P., Eicher, J., Geser, J., Freund, B., and Zierenberg, B. 2005. Device for producing high pressure in a fluid in miniature, US patent 69185467.
15.
go back to reference Zierenberg, B. 1999. Optimizing the in vitro performance of Respimat, J. Aerosol Med. 12:S19–S24.CrossRef Zierenberg, B. 1999. Optimizing the in vitro performance of Respimat, J. Aerosol Med. 12:S19–S24.CrossRef
16.
go back to reference Mercer, T. T., Tillery, M. I., and Chow, H. Y. 1968. Operating characteristics of some compressed-air nebulizers, Am. Ind. Hyg. J. 29:66–78. Mercer, T. T., Tillery, M. I., and Chow, H. Y. 1968. Operating characteristics of some compressed-air nebulizers, Am. Ind. Hyg. J. 29:66–78.
17.
go back to reference Dessanges, J.-F. 2001. A history of nebulization, J. Aerosol Med. 14:65–71.CrossRef Dessanges, J.-F. 2001. A history of nebulization, J. Aerosol Med. 14:65–71.CrossRef
18.
go back to reference Niven, R. W., Speer, M., Schreier, H. 1991. Nebulization of liposomes II. The effects of size and modelling of solute release profiles, Pharm. Res. 8:217–221.CrossRef Niven, R. W., Speer, M., Schreier, H. 1991. Nebulization of liposomes II. The effects of size and modelling of solute release profiles, Pharm. Res. 8:217–221.CrossRef
19.
go back to reference Lentz, Y. K., Worden, L. R., Anchordoquy, T. J., and Lengsfeld, C. S. 2005. Effect of jet nebulization on DNA: identifying the dominant degradation mechanism and mitigation methods, J. Aerosol Sci. 36:973–990.CrossRef Lentz, Y. K., Worden, L. R., Anchordoquy, T. J., and Lengsfeld, C. S. 2005. Effect of jet nebulization on DNA: identifying the dominant degradation mechanism and mitigation methods, J. Aerosol Sci. 36:973–990.CrossRef
20.
go back to reference Finlay, W. H., Lange, C. F., King, M., and Speert, D. 2000. Lung delivery of aerosolized dextran, Am. J. Resp. Crit. Care Med. 161:91–97. Finlay, W. H., Lange, C. F., King, M., and Speert, D. 2000. Lung delivery of aerosolized dextran, Am. J. Resp. Crit. Care Med. 161:91–97.
21.
go back to reference Finlay, W. H., Stapleton, K. W., and Zuberbuhler, P. 1998. Variations in predicted regional lung deposition of salbutamol sulphate between 19 nebulizer models, J. Aerosol Med. 11:65–80.CrossRef Finlay, W. H., Stapleton, K. W., and Zuberbuhler, P. 1998. Variations in predicted regional lung deposition of salbutamol sulphate between 19 nebulizer models, J. Aerosol Med. 11:65–80.CrossRef
22.
go back to reference Topp, M. 1973. Ultrasonic atomization – a photographic study of the mechanism of disintegration, J. Aerosol Sci. 4:17–25.CrossRef Topp, M. 1973. Ultrasonic atomization – a photographic study of the mechanism of disintegration, J. Aerosol Sci. 4:17–25.CrossRef
23.
go back to reference Cipolla, D. C., Clark, A. R., Chan, H. K., Gonda, I., and Shire, S. J. 1994. Assessment of aerosol delivery systems for recombinant human deoxyribonuclease, STP Pharm. Sci. 4:50–62. Cipolla, D. C., Clark, A. R., Chan, H. K., Gonda, I., and Shire, S. J. 1994. Assessment of aerosol delivery systems for recombinant human deoxyribonuclease, STP Pharm. Sci. 4:50–62.
24.
go back to reference Nikander, K., Turpeinen, M., and Wollmer, P. 1999. The conventional ultrasonic nebulizer proved inefficient in nebulizing a suspension, J. Aerosol Med. 12:47–53.CrossRef Nikander, K., Turpeinen, M., and Wollmer, P. 1999. The conventional ultrasonic nebulizer proved inefficient in nebulizing a suspension, J. Aerosol Med. 12:47–53.CrossRef
25.
go back to reference Ghazanfari, T., Elhissi, A. M. A., Ding, Z., and Taylor, K. M. G. 2007. The influence of fluid physicochemical properties on vibrating-mesh nebulization, Int. J. Pharm. 339:103–111.CrossRef Ghazanfari, T., Elhissi, A. M. A., Ding, Z., and Taylor, K. M. G. 2007. The influence of fluid physicochemical properties on vibrating-mesh nebulization, Int. J. Pharm. 339:103–111.CrossRef
26.
go back to reference Knoch, M. and Finlay, W. H. 2008. Nebulizer technologies. In Modified-Release Drug Delivery Technology, 2nd edn., ed. M. J. Rathbone, Marcel Dekker, pp. 613–622, Chap. 45. Knoch, M. and Finlay, W. H. 2008. Nebulizer technologies. In Modified-Release Drug Delivery Technology, 2nd edn., ed. M. J. Rathbone, Marcel Dekker, pp. 613–622, Chap. 45.
27.
go back to reference Lass, J. S., Sant, A., and Knoch, M. 2006. New advances in aerosolised drug delivery: vibrating membrane nebuliser technology, Exp. Op. Drug Del. 3:693–702.CrossRef Lass, J. S., Sant, A., and Knoch, M. 2006. New advances in aerosolised drug delivery: vibrating membrane nebuliser technology, Exp. Op. Drug Del. 3:693–702.CrossRef
28.
go back to reference Zhang, G., Anand, D., and Wiedmann, T. S. 2007. Performance of the vibrating membrane aerosol generation device: aeroneb micropump nebulizer, J. Aerosol Med. 20:408–416.CrossRef Zhang, G., Anand, D., and Wiedmann, T. S. 2007. Performance of the vibrating membrane aerosol generation device: aeroneb micropump nebulizer, J. Aerosol Med. 20:408–416.CrossRef
29.
go back to reference Knoch, M. and Keller, M. 2005. The customised electronic nebuliser: a new category of liquid aerosol drug delivery systems, Exp. Op. Drug Del. 2:377–390.CrossRef Knoch, M. and Keller, M. 2005. The customised electronic nebuliser: a new category of liquid aerosol drug delivery systems, Exp. Op. Drug Del. 2:377–390.CrossRef
30.
go back to reference Elhissi, A. M. A., Faizi, M., Naji, W. F., Gill, H. S., and Taylor, K. M. G. 2007. Physical stability and aerosol properties of liposomes delivered using an air-jet nebulizer and a novel micropump device with large mesh apertures, Int. J. Pharm. 334:62–70.CrossRef Elhissi, A. M. A., Faizi, M., Naji, W. F., Gill, H. S., and Taylor, K. M. G. 2007. Physical stability and aerosol properties of liposomes delivered using an air-jet nebulizer and a novel micropump device with large mesh apertures, Int. J. Pharm. 334:62–70.CrossRef
31.
go back to reference Rottier, B. L., van Erp, C. J. P., Sluyter, T. S., Heijerman, H. G. M., Frijlink, H. W. F., and de Boer, A. H. 2009. Changes in performance of the Pari eFlow® rapid and Pari LC Plus™ during 6 months use by CF patients, J. Aerosol Med. Pulm. Drug Del., ahead of print. doi:10.1089/jamp.2008.0712. Rottier, B. L., van Erp, C. J. P., Sluyter, T. S., Heijerman, H. G. M., Frijlink, H. W. F., and de Boer, A. H. 2009. Changes in performance of the Pari eFlow® rapid and Pari LC Plus™ during 6 months use by CF patients, J. Aerosol Med. Pulm. Drug Del., ahead of print. doi:10.1089/jamp.2008.0712.
Metadata
Title
Pharmaceutical Aerosol Sprays for Drug Delivery to the Lungs
Author
W. H. Finlay
Copyright Year
2011
Publisher
Springer US
DOI
https://doi.org/10.1007/978-1-4419-7264-4_41

Premium Partners