Skip to main content
Top
Published in: International Journal on Interactive Design and Manufacturing (IJIDeM) 3/2018

04-12-2017 | Original Paper

Registration of mandibular movement for dental diagnosis, planning and treatment

Authors: E. Solaberrieta, L. Barrenetxea, R. Minguez, M. Iturrate, I. De Prado

Published in: International Journal on Interactive Design and Manufacturing (IJIDeM) | Issue 3/2018

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

During the last decade, due to the digitalization of many procedures in the dental workflow, dentistry has undergone many changes. To begin with, virtual articulators substituted traditional mechanical articulators. Thanks to virtual articulators, exploring more options (manufacture in clinic, laboratory in different materials, among others) for each case became possible. Now, this study proposes a step forward in the registration of the patients’ mandibular movements, which allows taking into account the kinematics of each patient’s mandible in the design of prostheses. Surgeons and dentists require a comprehensive simulation system of the mandibular movements as a support for their design work. Taking into consideration the market needs, this article describes the work carried out to develop a method to capture mandibular movement. Using a Leap Motion device and rapid prototyped pieces, the developed system is simple and economically affordable. To design a dental prosthesis taking into account the movements of the antagonist, the most significant information regarding these mandibular movements—lateral movements, retrusion, protrusion and chewing—is necessary. In order to minimize interventions at the clinic, this kinematic design is essential because it eliminates occlusal interferences. However, this registration system is only applicable when an intraoral scanner and a virtual face bow are already integrated. Since the maxillary and mandibular casts must simulate the registered movements, the origin and relative position between both casts is essential. This virtual location of models and simulation of these movements enables the dentist, surgeon and lab technician to achieve a more interactive design, thus leading to a more functional design.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Park, J.H., Kim, J.E., Shim, J.S.: Digital workflow for a dental prosthesis that considers lateral mandibular relation. J. Prosthet. Dent. 117(3), 340–344 (2017)CrossRef Park, J.H., Kim, J.E., Shim, J.S.: Digital workflow for a dental prosthesis that considers lateral mandibular relation. J. Prosthet. Dent. 117(3), 340–344 (2017)CrossRef
2.
go back to reference Solaberrieta, E., Mínguez, R., Barrenetxea, L., Otegi, J.R., Szentpétery, A.: Comparison of the accuracy of a 3-dimensional virtual method and the conventional method for transferring the maxillary cast to a virtual articulator. J. Prosthet. Dent. 113(3), 191–197 (2015)CrossRef Solaberrieta, E., Mínguez, R., Barrenetxea, L., Otegi, J.R., Szentpétery, A.: Comparison of the accuracy of a 3-dimensional virtual method and the conventional method for transferring the maxillary cast to a virtual articulator. J. Prosthet. Dent. 113(3), 191–197 (2015)CrossRef
3.
go back to reference Solaberrieta, E., Garmendia, A., Mínguez, R., Brizuela, A., Pradies, A.: Virtual facebow technique. J. Prosthet. Dent. 114(6), 751–755 (2015)CrossRef Solaberrieta, E., Garmendia, A., Mínguez, R., Brizuela, A., Pradies, A.: Virtual facebow technique. J. Prosthet. Dent. 114(6), 751–755 (2015)CrossRef
4.
go back to reference Solaberrieta, E., Etxaniz, O., Minguez, R., Gorozika, J., Barrenetxea, L., Sierra, E.: Virtual production of dental prostheses using a dental virtual articulator. Int. J. Interact. Des. Manuf. 9, 19–30 (2015)CrossRef Solaberrieta, E., Etxaniz, O., Minguez, R., Gorozika, J., Barrenetxea, L., Sierra, E.: Virtual production of dental prostheses using a dental virtual articulator. Int. J. Interact. Des. Manuf. 9, 19–30 (2015)CrossRef
5.
go back to reference Seelbach, P., Brueckel, C., Woestmann, B.: Accuracy of digital and conventional impression techniques and workflow. Clin. Oral Investig. 17(7), 1759–1764 (2013)CrossRef Seelbach, P., Brueckel, C., Woestmann, B.: Accuracy of digital and conventional impression techniques and workflow. Clin. Oral Investig. 17(7), 1759–1764 (2013)CrossRef
7.
go back to reference Mitchell, D.L., Wilkie, N.D.: Articulators through the years. Part I. Up to 1940. J. Prosthet. Dent. 39, 330–338 (1978)CrossRef Mitchell, D.L., Wilkie, N.D.: Articulators through the years. Part I. Up to 1940. J. Prosthet. Dent. 39, 330–338 (1978)CrossRef
8.
go back to reference Mitchell, D.L., Wilkie, N.D.: Articulators through the years. Part II. From 1940. J. Prosthet. Dent. 39, 451–458 (1978)CrossRef Mitchell, D.L., Wilkie, N.D.: Articulators through the years. Part II. From 1940. J. Prosthet. Dent. 39, 451–458 (1978)CrossRef
9.
go back to reference Reiss, B.: Occlusal surface design with Cerec 3D. Int. J. Comput. Dent. 6(4), 333–342 (2003) Reiss, B.: Occlusal surface design with Cerec 3D. Int. J. Comput. Dent. 6(4), 333–342 (2003)
10.
go back to reference Kaur, I., Datta, K.: CEREC: the power of technology. J. Indian Prosthodont. Soc. 6, 115–119 (2006)CrossRef Kaur, I., Datta, K.: CEREC: the power of technology. J. Indian Prosthodont. Soc. 6, 115–119 (2006)CrossRef
11.
go back to reference Otto, T., Schneider, D.: Long-term clinical results of chairside Cerec CAD/CAM inlays and onlays: a case series. Int. J. Prosthodont. 21(1), 53–59 (2008) Otto, T., Schneider, D.: Long-term clinical results of chairside Cerec CAD/CAM inlays and onlays: a case series. Int. J. Prosthodont. 21(1), 53–59 (2008)
12.
go back to reference Szentpétery, A.: Computer aided dynamic correction of digitized occlusal surfaces. J. Gnathol. 16, 53–60 (1997) Szentpétery, A.: Computer aided dynamic correction of digitized occlusal surfaces. J. Gnathol. 16, 53–60 (1997)
13.
go back to reference Sójka, A., Huber, J., Kaczmarek, E., Hȩdzelek, W.: Evaluation of mandibular movement functions using instrumental ultrasound system. J. Prosthodont. 26(2), 123–128 (2017)CrossRef Sójka, A., Huber, J., Kaczmarek, E., Hȩdzelek, W.: Evaluation of mandibular movement functions using instrumental ultrasound system. J. Prosthodont. 26(2), 123–128 (2017)CrossRef
14.
go back to reference Lippold, C., Hoppe, G., Moiseenko, T., Ehmer, U., Danesh, G.: Analysis of condylar differences in functional unilateral posterior crossbite during early treatment-a randomized clinical study. J. Orofac. Orthop. 69(4), 283–296 (2008)CrossRef Lippold, C., Hoppe, G., Moiseenko, T., Ehmer, U., Danesh, G.: Analysis of condylar differences in functional unilateral posterior crossbite during early treatment-a randomized clinical study. J. Orofac. Orthop. 69(4), 283–296 (2008)CrossRef
15.
go back to reference Dai, F., Wang, L., Chen, G., Chen, S., Xu, T.: Three-dimensional modeling of an individualized functional masticatory system and bite force analysis with an orthodontic bite plate. Int. J. Comput. Assist. Radiol. Surg. 11(2), 217–229 (2016)CrossRef Dai, F., Wang, L., Chen, G., Chen, S., Xu, T.: Three-dimensional modeling of an individualized functional masticatory system and bite force analysis with an orthodontic bite plate. Int. J. Comput. Assist. Radiol. Surg. 11(2), 217–229 (2016)CrossRef
16.
go back to reference Wagner, J.D., Moore, D.L.: Preoperative laboratory testing for the oral and maxillofacial surgery patient. J. Oral Maxillofac. Surg. 49(2), 177–182 (1991)CrossRef Wagner, J.D., Moore, D.L.: Preoperative laboratory testing for the oral and maxillofacial surgery patient. J. Oral Maxillofac. Surg. 49(2), 177–182 (1991)CrossRef
17.
go back to reference Teng, T.Terry Te-Yi, Ko, E.Ching, Huang, C.S., Chen, Y.: The effect of early physiotherapy on the recovery of mandibular function after orthognathic surgery for Class III correction: part I-jaw-motion analysis. J. Craniomaxillofac. Surg. 43(1), 131–137 (2015)CrossRef Teng, T.Terry Te-Yi, Ko, E.Ching, Huang, C.S., Chen, Y.: The effect of early physiotherapy on the recovery of mandibular function after orthognathic surgery for Class III correction: part I-jaw-motion analysis. J. Craniomaxillofac. Surg. 43(1), 131–137 (2015)CrossRef
18.
go back to reference Ching Ko, E., Huang, C.S., Lo, L., Chen, Y.: Longitudinal observation of mandibular motion pattern in patients with skeletal Class III malocclusion subsequent to orthognathic surgery. J. Oral Maxillofac. Surg. 70(2), 158–168 (2012)CrossRef Ching Ko, E., Huang, C.S., Lo, L., Chen, Y.: Longitudinal observation of mandibular motion pattern in patients with skeletal Class III malocclusion subsequent to orthognathic surgery. J. Oral Maxillofac. Surg. 70(2), 158–168 (2012)CrossRef
19.
go back to reference Baqaien, M., Barra, J., Muessig, D.: Computerized axiographic evaluation of the changes in sagittal condylar path inclination with dental and physical development. Am. J. Orthod. Dentofacial. Orthop. 135(1), 88–94 (2009)CrossRef Baqaien, M., Barra, J., Muessig, D.: Computerized axiographic evaluation of the changes in sagittal condylar path inclination with dental and physical development. Am. J. Orthod. Dentofacial. Orthop. 135(1), 88–94 (2009)CrossRef
20.
go back to reference Ching Ko, E., Alazizi, A., Lin, C.: Three-dimensional surgical changes of mandibular proximal segments affect outcome of jaw motion analysis. J. Oral Maxillofac. Surg. 73(5), 971–984 (2015)CrossRef Ching Ko, E., Alazizi, A., Lin, C.: Three-dimensional surgical changes of mandibular proximal segments affect outcome of jaw motion analysis. J. Oral Maxillofac. Surg. 73(5), 971–984 (2015)CrossRef
21.
go back to reference Fang, J.J., Kuo, T.H.: Modelling of mandibular movement. Comput. Biol. Med. 38(11), 1152–1162 (2008)CrossRef Fang, J.J., Kuo, T.H.: Modelling of mandibular movement. Comput. Biol. Med. 38(11), 1152–1162 (2008)CrossRef
22.
go back to reference Fang, J.J., Kuo, T.H.: Tracked motion-based dental occlusion surface estimation for crown restoration. Comput. Aided Des. 41(4), 315–323 (2009)CrossRef Fang, J.J., Kuo, T.H.: Tracked motion-based dental occlusion surface estimation for crown restoration. Comput. Aided Des. 41(4), 315–323 (2009)CrossRef
23.
go back to reference Kumar, V., Ludlow, J., Soares, L.H., et al.: In vivo comparison of conventional and cone beam CT synthesized cephalograms. Angle Orthod. 78(5), 873–879 (2008)CrossRef Kumar, V., Ludlow, J., Soares, L.H., et al.: In vivo comparison of conventional and cone beam CT synthesized cephalograms. Angle Orthod. 78(5), 873–879 (2008)CrossRef
24.
go back to reference Alsufyani, N., Noga, M., Finlay, W., et al.: Topical contrast agents to improve soft-tissue contrast in the upper airway using cone beam CT: a pilot study. Dentomaxillofac. Radio. 42(7), 20130022 (2013)CrossRef Alsufyani, N., Noga, M., Finlay, W., et al.: Topical contrast agents to improve soft-tissue contrast in the upper airway using cone beam CT: a pilot study. Dentomaxillofac. Radio. 42(7), 20130022 (2013)CrossRef
25.
go back to reference Rottke, D., Patzelt, S., Poxleitner, P., et al.: Effective dose span of ten different cone beam CT devices. Dentomaxillofac. Radio. 42(7), 20120417 (2013)CrossRef Rottke, D., Patzelt, S., Poxleitner, P., et al.: Effective dose span of ten different cone beam CT devices. Dentomaxillofac. Radio. 42(7), 20120417 (2013)CrossRef
26.
go back to reference Solaberrieta, E., Mínguez, R., Barrenetxea, L., et al.: Direct transfer of the position of digitized casts to a virtual articulator. J. Prosthet. Dent. 109(6), 411–414 (2013)CrossRef Solaberrieta, E., Mínguez, R., Barrenetxea, L., et al.: Direct transfer of the position of digitized casts to a virtual articulator. J. Prosthet. Dent. 109(6), 411–414 (2013)CrossRef
27.
go back to reference Barone, S., Casinelli, M., Frascaria, M., Paoli, A., Razionale, A.: Interactive design of dental implant placements through CAD-CAM technologies: from 3D imaging to additive manufacturing. Int. J. Interact. Des. Manuf. 10, 105–117 (2016)CrossRef Barone, S., Casinelli, M., Frascaria, M., Paoli, A., Razionale, A.: Interactive design of dental implant placements through CAD-CAM technologies: from 3D imaging to additive manufacturing. Int. J. Interact. Des. Manuf. 10, 105–117 (2016)CrossRef
28.
go back to reference Delangle, M., Petiot, J.F., Poirson, E.: Using motion capture to study human standing accessibility: comparison between physical experiment, static model and virtual ergonomic evaluations. Int. J. Interact. Des. Manuf. 11, 515–524 (2017)CrossRef Delangle, M., Petiot, J.F., Poirson, E.: Using motion capture to study human standing accessibility: comparison between physical experiment, static model and virtual ergonomic evaluations. Int. J. Interact. Des. Manuf. 11, 515–524 (2017)CrossRef
29.
go back to reference Barone, S., Paoli, A., Razionale, A., Savignano, R.: Computer aided modelling to simulate the biomechanical behaviour of customised orthodontic removable appliances. Int. J. Interact. Des. Manuf. 10, 387–400 (2016)CrossRef Barone, S., Paoli, A., Razionale, A., Savignano, R.: Computer aided modelling to simulate the biomechanical behaviour of customised orthodontic removable appliances. Int. J. Interact. Des. Manuf. 10, 387–400 (2016)CrossRef
30.
go back to reference Garcia-Zapirain, B., de la Torre Díez, I., López-Coronado, M.: Dual system for enhancing cognitive abilities of children with ADHD using Leap Motion and eye-tracking technologies. J. Med. Syst. 41(7), 111 (2017)CrossRef Garcia-Zapirain, B., de la Torre Díez, I., López-Coronado, M.: Dual system for enhancing cognitive abilities of children with ADHD using Leap Motion and eye-tracking technologies. J. Med. Syst. 41(7), 111 (2017)CrossRef
31.
go back to reference Sun, X., Byrns, S., Cheng, I., Zheng, B., Basu, A.: Smart sensor-based motion detection system for hand movement training in open surgery. J. Med. Syst. 41(2), 24 (2017)CrossRef Sun, X., Byrns, S., Cheng, I., Zheng, B., Basu, A.: Smart sensor-based motion detection system for hand movement training in open surgery. J. Med. Syst. 41(2), 24 (2017)CrossRef
32.
go back to reference Smeragliuolo, A.H., Hill, N.J., Disla, L., Putrino, D.: Validation of the Leap Motion controller using markered motion capture technology. J. Biomech. 49(9), 1742–1750 (2016)CrossRef Smeragliuolo, A.H., Hill, N.J., Disla, L., Putrino, D.: Validation of the Leap Motion controller using markered motion capture technology. J. Biomech. 49(9), 1742–1750 (2016)CrossRef
33.
go back to reference Juanes, J.A., Gómez, J.J., Peguero, P.D., Ruisoto, P.: Digital environment for movement control in surgical skill training. J. Med. Syst. 40(6), 133 (2016)CrossRef Juanes, J.A., Gómez, J.J., Peguero, P.D., Ruisoto, P.: Digital environment for movement control in surgical skill training. J. Med. Syst. 40(6), 133 (2016)CrossRef
34.
go back to reference Tung, J.Y., Lulic, T., Gonzalez, D.A., Tran, J., Dickerson, C.R., Roy, E.A.: Evaluation of a portable markerless finger position capture device: accuracy of the Leap Motion controller in healthy adults. Physiol. Meas. 36(5), 1025–1035 (2015)CrossRef Tung, J.Y., Lulic, T., Gonzalez, D.A., Tran, J., Dickerson, C.R., Roy, E.A.: Evaluation of a portable markerless finger position capture device: accuracy of the Leap Motion controller in healthy adults. Physiol. Meas. 36(5), 1025–1035 (2015)CrossRef
35.
go back to reference Bachmann, D., Weichert, F., Rudak, B., Fisseler, D.: Analysis of the accuracy and robustness of the Leap Motion controller. Sensors 13(5), 6380–6393 (2013)CrossRef Bachmann, D., Weichert, F., Rudak, B., Fisseler, D.: Analysis of the accuracy and robustness of the Leap Motion controller. Sensors 13(5), 6380–6393 (2013)CrossRef
36.
go back to reference Matta, R.E., Bergauer, B., Adler, W., Wichmann, M., Nickenig, H.: The impact of the fabrication method on the three-dimensional accuracy of an implant surgery template. J. Craniomaxillofac. Surg. 45(6), 804–808 (2017)CrossRef Matta, R.E., Bergauer, B., Adler, W., Wichmann, M., Nickenig, H.: The impact of the fabrication method on the three-dimensional accuracy of an implant surgery template. J. Craniomaxillofac. Surg. 45(6), 804–808 (2017)CrossRef
37.
go back to reference Ramos, B., Santos, E.: Comparative study of different digitization techniques and their accuracy. Comput. Aided Des. 43(2), 188–206 (2011)CrossRef Ramos, B., Santos, E.: Comparative study of different digitization techniques and their accuracy. Comput. Aided Des. 43(2), 188–206 (2011)CrossRef
38.
go back to reference Matta, R.E., Adler, W., Wichmann, M., Heckmann, S.M.: Accuracy of impression scanning compared with stone casts of implant impressions. J. Prosthet. Dent. 117(4), 507–512 (2017)CrossRef Matta, R.E., Adler, W., Wichmann, M., Heckmann, S.M.: Accuracy of impression scanning compared with stone casts of implant impressions. J. Prosthet. Dent. 117(4), 507–512 (2017)CrossRef
39.
go back to reference Palousek, D., Omasta, M., Koutny, D., Bednar, J., Koutecky, T., Dokoupil, F.: Effect of matte coating on 3D optical measurement accuracy. Opt. Mater. 40, 1–9 (2015)CrossRef Palousek, D., Omasta, M., Koutny, D., Bednar, J., Koutecky, T., Dokoupil, F.: Effect of matte coating on 3D optical measurement accuracy. Opt. Mater. 40, 1–9 (2015)CrossRef
40.
go back to reference Matta, R.E., Wilmowsky, C., Neuhuber, W., Lell, M., Neukam, F., Adler, W., Wichmann, M., Bergauer, B.: The impact of different cone beam computed tomography and multi-slice computed tomography scan parameters on virtual three-dimensional model accuracy using a highly precise ex vivo evaluation method. J. Craniomaxillofac. Surg. 44(5), 632–636 (2016)CrossRef Matta, R.E., Wilmowsky, C., Neuhuber, W., Lell, M., Neukam, F., Adler, W., Wichmann, M., Bergauer, B.: The impact of different cone beam computed tomography and multi-slice computed tomography scan parameters on virtual three-dimensional model accuracy using a highly precise ex vivo evaluation method. J. Craniomaxillofac. Surg. 44(5), 632–636 (2016)CrossRef
Metadata
Title
Registration of mandibular movement for dental diagnosis, planning and treatment
Authors
E. Solaberrieta
L. Barrenetxea
R. Minguez
M. Iturrate
I. De Prado
Publication date
04-12-2017
Publisher
Springer Paris
Published in
International Journal on Interactive Design and Manufacturing (IJIDeM) / Issue 3/2018
Print ISSN: 1955-2513
Electronic ISSN: 1955-2505
DOI
https://doi.org/10.1007/s12008-017-0438-4

Other articles of this Issue 3/2018

International Journal on Interactive Design and Manufacturing (IJIDeM) 3/2018 Go to the issue

Premium Partner