Skip to main content
Top
Published in: Cluster Computing 3/2019

28-08-2017

The computation on compressor model of DC inverter based on the intelligent sensing algorithm of water heater system performance

Authors: Xuepeng Liu, Xiaohong Hao, Dongsheng Zhang

Published in: Cluster Computing | Special Issue 3/2019

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

The DC inverter is introduced to heat pump water heater system. Exchanger and evaporator mathematical equations are proposed to describe the compressor. The double PI closed-loop strategy is utilized to control inverter heater system. Optimal parameters are verified using experimental methods for measuring heat transfer performance. The refrigerant charge quantity is optimized by the model and experimental data. The optimal value is 3.6 kg. Taking into account the influence of the energy efficiency ratio, output heating and output water on the system performance, the optimal length of capillary tube is 0.65 mm for DC inverter heat pump water heater system.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Medgreen: Quasi-steady state modeling of an air source heat pump water heater. Energy Proc. 6, 325–330 (2011) Medgreen: Quasi-steady state modeling of an air source heat pump water heater. Energy Proc. 6, 325–330 (2011)
2.
go back to reference Zhang, L., Guo, X., Li, W.: Numerical and experimental study on dynamic performance of heat pump water heater with electronic expansion valve. J. Energy Power Eng. 10, 1582–1588 (2012) Zhang, L., Guo, X., Li, W.: Numerical and experimental study on dynamic performance of heat pump water heater with electronic expansion valve. J. Energy Power Eng. 10, 1582–1588 (2012)
3.
go back to reference Chen, Z., Tao, W., Zhu, Y., Hu, P.: Performance analysis of air-water dual source heat pump water heater with heat recovery. Sci. Chin. Technol. 42(8), 937–944 (2012) Chen, Z., Tao, W., Zhu, Y., Hu, P.: Performance analysis of air-water dual source heat pump water heater with heat recovery. Sci. Chin. Technol. 42(8), 937–944 (2012)
4.
go back to reference Huang, J., Li, S.: Application of variable frequency two-stage enthalpy-adding heat pumping technology in air source heat pump water heater. Chin. J. Refrig. Technol. 1 (2014) Huang, J., Li, S.: Application of variable frequency two-stage enthalpy-adding heat pumping technology in air source heat pump water heater. Chin. J. Refrig. Technol. 1 (2014)
5.
go back to reference Sun, F., Ma, Y., Wei, Y., Li, D.: Energy analysis of transcritical carbon dioxide refrigeration cycle with an ejector. In: ICEET, pp. 719–723 (2011) Sun, F., Ma, Y., Wei, Y., Li, D.: Energy analysis of transcritical carbon dioxide refrigeration cycle with an ejector. In: ICEET, pp. 719–723 (2011)
6.
go back to reference Liu, K., Lv, J., Zhang, S.B., Yang, J.: Study of circuit number on the evaporator in CO\(_2\) heat pump water heater. Appl. Mech. Mater. 71–78, 2266–2270 (2011)CrossRef Liu, K., Lv, J., Zhang, S.B., Yang, J.: Study of circuit number on the evaporator in CO\(_2\) heat pump water heater. Appl. Mech. Mater. 71–78, 2266–2270 (2011)CrossRef
7.
go back to reference Chen, G., Liang, L., Tang, L., et al.: Experimental investigation of an adjustable ejector for CO\(_2\) heat pump water heaters. J. Zhejiang Univ. 10(11), 1678–1682 (2009)CrossRef Chen, G., Liang, L., Tang, L., et al.: Experimental investigation of an adjustable ejector for CO\(_2\) heat pump water heaters. J. Zhejiang Univ. 10(11), 1678–1682 (2009)CrossRef
8.
go back to reference Yang, Y., Wang, S., Li, J., Li, G.: Current study on gas cooler of CO\(_2\) transcritical refrigeration cycle. Refrig. Air-cond. 14(2), 04–10 (2014) Yang, Y., Wang, S., Li, J., Li, G.: Current study on gas cooler of CO\(_2\) transcritical refrigeration cycle. Refrig. Air-cond. 14(2), 04–10 (2014)
9.
go back to reference Li, Y., Gong, Y., Peng, J.: Performance analysis of CO2 transcritical refrigeration system units‘ improvement. J. Zhengzhou Univ. Light Ind. (Nat. Sci. Ed.) 29(2), 80–86 (2014) Li, Y., Gong, Y., Peng, J.: Performance analysis of CO2 transcritical refrigeration system units‘ improvement. J. Zhengzhou Univ. Light Ind. (Nat. Sci. Ed.) 29(2), 80–86 (2014)
10.
go back to reference Li, T., Wang, D., Zhong, J., et al.: Experimental study on CO\(_2\) house-hold heat pump water heater. Chem. Eng. 41(2), 9–12 (2013)CrossRef Li, T., Wang, D., Zhong, J., et al.: Experimental study on CO\(_2\) house-hold heat pump water heater. Chem. Eng. 41(2), 9–12 (2013)CrossRef
11.
go back to reference Lv, J., Ren, Y., Yang, J., et al.: Experimental study on the influence of the water temperature to the performance of CO\(_2\) heat pump water heater. J. Refrig. 333(6), 73–77 (2012) Lv, J., Ren, Y., Yang, J., et al.: Experimental study on the influence of the water temperature to the performance of CO\(_2\) heat pump water heater. J. Refrig. 333(6), 73–77 (2012)
12.
go back to reference Chen, Q., Tong, Y., et al.: Experimental study on CO\(_2\) air source heat pump water heater. J. Zhejiang Univ. 46(4), 610–615 (2012) Chen, Q., Tong, Y., et al.: Experimental study on CO\(_2\) air source heat pump water heater. J. Zhejiang Univ. 46(4), 610–615 (2012)
13.
go back to reference Wang, Z., Gong, Y., Wu, X., et al.: Experimental research of transcritical CO\(_2\) heat pump system with double expansion valve. J. Refrig. 33(6), 57–61 (2012) Wang, Z., Gong, Y., Wu, X., et al.: Experimental research of transcritical CO\(_2\) heat pump system with double expansion valve. J. Refrig. 33(6), 57–61 (2012)
14.
go back to reference Bao, T., Lie, Y., Cai, C.: Experimental study on CO\(_2\) heat pump water heater with capillary tube as throttling device. Refrig. Technol. 2, 23–26 (2011) Bao, T., Lie, Y., Cai, C.: Experimental study on CO\(_2\) heat pump water heater with capillary tube as throttling device. Refrig. Technol. 2, 23–26 (2011)
15.
go back to reference Cai, C., Liu, Y., Su, Q.: Experimental study on heat pump water heater with transcritical CO\(_2\) cycle. Refrig. Air-Cond. 11(1), 66–70 (2011) Cai, C., Liu, Y., Su, Q.: Experimental study on heat pump water heater with transcritical CO\(_2\) cycle. Refrig. Air-Cond. 11(1), 66–70 (2011)
16.
go back to reference Gong, Y., Liang, Z., Hou, F., et al.: Experimental research of CO\(_2\) trans-critical cycle water source heat pump system. J. Zhengzhou Univ. Light Ind. (Nat. Sci.) 26(4), 41–44 (2011) Gong, Y., Liang, Z., Hou, F., et al.: Experimental research of CO\(_2\) trans-critical cycle water source heat pump system. J. Zhengzhou Univ. Light Ind. (Nat. Sci.) 26(4), 41–44 (2011)
17.
go back to reference Jin, T., Lu, G., Zheng, Z.: Performance comparison of a R410a direct-current frequency heat pump water heater running at variable refrigerant flows. Fluid Mach. 39(5), 70–73 (2011) Jin, T., Lu, G., Zheng, Z.: Performance comparison of a R410a direct-current frequency heat pump water heater running at variable refrigerant flows. Fluid Mach. 39(5), 70–73 (2011)
18.
go back to reference Gong, Y., Liang, Z.: Experimental research of trans-critical CO\(_2\) heat pump system performance. Fluid Mach. 39(9), 66–69 (2011) Gong, Y., Liang, Z.: Experimental research of trans-critical CO\(_2\) heat pump system performance. Fluid Mach. 39(9), 66–69 (2011)
19.
go back to reference Jiang, Y., Ma, Y., Li, M., Fu, L.: An experimental study of trans-critical CO\(_2\) water heat pump using compact tube-in-tube heat exchangers. Energy Convers. Manage. 76, 92–100 (2013)CrossRef Jiang, Y., Ma, Y., Li, M., Fu, L.: An experimental study of trans-critical CO\(_2\) water heat pump using compact tube-in-tube heat exchangers. Energy Convers. Manage. 76, 92–100 (2013)CrossRef
20.
go back to reference Yokoyama, R., Wakui, T., Kamakari, J., Takemura, K.: Performance analysis of a CO\(_2\) heat pump water heating system under a daily change in a standardizeddemand. Energy 35, 718–728 (2010)CrossRef Yokoyama, R., Wakui, T., Kamakari, J., Takemura, K.: Performance analysis of a CO\(_2\) heat pump water heating system under a daily change in a standardizeddemand. Energy 35, 718–728 (2010)CrossRef
21.
go back to reference Fornasieri, E., Girotto, S., Minetto, S.: CO\(_2\) heat pump for domestic hot water. In: 8th IIR Gustav Lorentzen Conference on Natural Working Fluids, Copenhagen, 7–10 September (2008) Fornasieri, E., Girotto, S., Minetto, S.: CO\(_2\) heat pump for domestic hot water. In: 8th IIR Gustav Lorentzen Conference on Natural Working Fluids, Copenhagen, 7–10 September (2008)
22.
go back to reference Minetto, S.: Theoretical and experimental analysis of a CO\(_2\) heat pump for domestic hot water. Int. J. Refrig. 34, 742–751 (2011)CrossRef Minetto, S.: Theoretical and experimental analysis of a CO\(_2\) heat pump for domestic hot water. Int. J. Refrig. 34, 742–751 (2011)CrossRef
23.
go back to reference Wang, T., Dharkar, S., Kurtulus, O., Groll, E.A., Yazawa, K.: Experimental study of a CO\(_2\) thermal battery for simultaneous cooling and heating applications. In: Proceedings of 15th International Refrigeration and Air Conditioning Conference at Purdue, West Lafayette, R2701 (2014) Wang, T., Dharkar, S., Kurtulus, O., Groll, E.A., Yazawa, K.: Experimental study of a CO\(_2\) thermal battery for simultaneous cooling and heating applications. In: Proceedings of 15th International Refrigeration and Air Conditioning Conference at Purdue, West Lafayette, R2701 (2014)
24.
go back to reference Jensen, L.H., Holten, A., Blarke, M.B., Groll, E.A., Shakouri, A., Yazawa, K.: Dynamicanalysis of a dual-mode CO\(_2\) heat pump with both hot and cold thermal storage. In: Proceedings of the ASME 2013 International Mechanical Engineering Congress and Exposition, San Diego, IMECE2013-62894 (2013) Jensen, L.H., Holten, A., Blarke, M.B., Groll, E.A., Shakouri, A., Yazawa, K.: Dynamicanalysis of a dual-mode CO\(_2\) heat pump with both hot and cold thermal storage. In: Proceedings of the ASME 2013 International Mechanical Engineering Congress and Exposition, San Diego, IMECE2013-62894 (2013)
25.
go back to reference Huang, Z., Chen, W., Tu, J.: Fuzzy temperature control arithmetic for household variable frequency air-conditioner. J. Univ. Shanghai Sci. Technol. 35(2), 169–174 (2013) Huang, Z., Chen, W., Tu, J.: Fuzzy temperature control arithmetic for household variable frequency air-conditioner. J. Univ. Shanghai Sci. Technol. 35(2), 169–174 (2013)
26.
go back to reference Liu, X., Hao, X., Zhang, D.: Multi-strategy wide-frequency control technology of DC air conditioner PMSM. J. Sichuan Ordnance 34(6), 97–100 (2013) Liu, X., Hao, X., Zhang, D.: Multi-strategy wide-frequency control technology of DC air conditioner PMSM. J. Sichuan Ordnance 34(6), 97–100 (2013)
27.
go back to reference Guo, Y., Chen, M., Chen, N.: Rotor speed estimate method for sensorless vector control of BLDCM. Control Eng. Chin. 20(2), 348–352 (2013) Guo, Y., Chen, M., Chen, N.: Rotor speed estimate method for sensorless vector control of BLDCM. Control Eng. Chin. 20(2), 348–352 (2013)
28.
go back to reference Wang, W., Li, T., Wu, S.: The design of electrical control system of DC inverter air conditioner. Small Spec. Electr. Mach. 41(11), 7–12 (2013) Wang, W., Li, T., Wu, S.: The design of electrical control system of DC inverter air conditioner. Small Spec. Electr. Mach. 41(11), 7–12 (2013)
29.
go back to reference Zhang, S., Liu, G., Wang, W.: Parameter identification methods for conversion air conditioner compressor motor. J. Power Supply 1, 95–100 (2013) Zhang, S., Liu, G., Wang, W.: Parameter identification methods for conversion air conditioner compressor motor. J. Power Supply 1, 95–100 (2013)
30.
go back to reference Wang, N., Lu, F., Yang, X., et al.: Application of a three-phase three-level rectifier inverter air conditioner. Electr. Autom. 35(2), 17–20 (2013) Wang, N., Lu, F., Yang, X., et al.: Application of a three-phase three-level rectifier inverter air conditioner. Electr. Autom. 35(2), 17–20 (2013)
31.
go back to reference Cao, C., Jiang, S., et al.: The design of inverter air-conditioner PWM rectifier. Electr. Appl. 4, 48–52 (2013) Cao, C., Jiang, S., et al.: The design of inverter air-conditioner PWM rectifier. Electr. Appl. 4, 48–52 (2013)
32.
go back to reference Li, X., Ji, J., Ma, S., et al.: Development of sensorless sinusoidal inverter drive controller for central air-conditioning compressor. Compress. Technol. 6, 21–25 (2013) Li, X., Ji, J., Ma, S., et al.: Development of sensorless sinusoidal inverter drive controller for central air-conditioning compressor. Compress. Technol. 6, 21–25 (2013)
33.
go back to reference Liu, X., Zhao, D.: Study on PMSM field oriented inventor regulating speed techngoloy. Mach. Tool Hydraul. 38, 106–108 (2010) Liu, X., Zhao, D.: Study on PMSM field oriented inventor regulating speed techngoloy. Mach. Tool Hydraul. 38, 106–108 (2010)
Metadata
Title
The computation on compressor model of DC inverter based on the intelligent sensing algorithm of water heater system performance
Authors
Xuepeng Liu
Xiaohong Hao
Dongsheng Zhang
Publication date
28-08-2017
Publisher
Springer US
Published in
Cluster Computing / Issue Special Issue 3/2019
Print ISSN: 1386-7857
Electronic ISSN: 1573-7543
DOI
https://doi.org/10.1007/s10586-017-1130-y

Other articles of this Special Issue 3/2019

Cluster Computing 3/2019 Go to the issue