Skip to main content
Top
Published in: Medical & Biological Engineering & Computing 7-8/2021

22-06-2021 | Original Article

Tip estimation approach for concentric tube robots using 2D ultrasound images and kinematic model

Authors: Zihao Li, Xing Yang, Shuang Song, Li Liu, Max Q.-H. Meng

Published in: Medical & Biological Engineering & Computing | Issue 7-8/2021

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Concentric tube robot (CTR) is an efficient approach for minimally invasive surgery (MIS) and diagnosis due to its small size and high dexterity. To manipulate the robot accurately and safely inside the human body, tip position and shape information need to be well measured. In this paper, we propose a tip estimation method based on 2D ultrasound images with the help of the forward kinematic model of CTR. The forward kinematic model can help to provide a fast ultrasound scanning path and narrow the region of interest in ultrasound images. For each tube, only three scan positions are needed by combining the kinematic model prediction as prior knowledge. After that, the curve fitting method is used for its shape reconstruction, while its tip position can be estimated based on the constraints of its structure and length.7 This method provides the advantage that only three scan positions are needed for estimating the tip of each telescoping section. Moreover, no structure modification is needed on the robot, which makes it an appropriate approach for existing flexible surgical robots. Experimental results verified the feasibility of the proposed method and the tip estimation error is 0.59 mm.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Amack S, Rox MF, Emerson M, Webster RJ, Alterovitz R, Kuntz A, Mitchell J, Ertop TE, Gafford J, Maldonado F, Akulian J (2019) Design and control of a compact modular robot for transbronchial lung biopsy. In: Fei B, Linte CA (eds) Medical imaging 2019: image-guided procedures, robotic interventions, and modeling. https://doi.org/10.1117/12.2513967. SPIE Amack S, Rox MF, Emerson M, Webster RJ, Alterovitz R, Kuntz A, Mitchell J, Ertop TE, Gafford J, Maldonado F, Akulian J (2019) Design and control of a compact modular robot for transbronchial lung biopsy. In: Fei B, Linte CA (eds) Medical imaging 2019: image-guided procedures, robotic interventions, and modeling. https://​doi.​org/​10.​1117/​12.​2513967. SPIE
5.
go back to reference Denasi A, Khan F, Boskma KJ, Kaya M, Hennersperger C, Gobl R, Tirindelli M, Navab N, Misra S (2018) An Observer-Based fusion method using multicore optical shape sensors and ultrasound images for magnetically-actuated catheters. In: Proceedings - IEEE international conference on robotics and automation. https://doi.org/10.1109/ICRA.2018.8462695, pp 50–57 Denasi A, Khan F, Boskma KJ, Kaya M, Hennersperger C, Gobl R, Tirindelli M, Navab N, Misra S (2018) An Observer-Based fusion method using multicore optical shape sensors and ultrasound images for magnetically-actuated catheters. In: Proceedings - IEEE international conference on robotics and automation. https://​doi.​org/​10.​1109/​ICRA.​2018.​8462695, pp 50–57
7.
go back to reference Dupont PE, Gosline A, Vasilyev N, Lock J, Butler E, Folk C, Cohen a Chen R, Schmitz G, Ren H, del Nido P (2012) Concentric tube robots for minimally invasive surgery. In: Hamlyn symposium on medical robotics, pp 3–5 Dupont PE, Gosline A, Vasilyev N, Lock J, Butler E, Folk C, Cohen a Chen R, Schmitz G, Ren H, del Nido P (2012) Concentric tube robots for minimally invasive surgery. In: Hamlyn symposium on medical robotics, pp 3–5
9.
10.
go back to reference Gilbert HB, Rucker DC, Webster IIIRJ (2016) Concentric tube robots: the state of the art and future directions. In: Springer Tracts in Advanced Robotics, vol 114, pp 253–269 Gilbert HB, Rucker DC, Webster IIIRJ (2016) Concentric tube robots: the state of the art and future directions. In: Springer Tracts in Advanced Robotics, vol 114, pp 253–269
11.
go back to reference Hongliang Ren, Dupont PE (2011) Tubular structure enhancement for surgical instrument detection in 3D ultrasound. In: 2011 Annual international conference of the ieee engineering in medicine and biology society, vol 23. IEEE, pp 7203–7206. https://doi.org/10.1109/IEMBS.2011.6091820, NIHMS150003 Hongliang Ren, Dupont PE (2011) Tubular structure enhancement for surgical instrument detection in 3D ultrasound. In: 2011 Annual international conference of the ieee engineering in medicine and biology society, vol 23. IEEE, pp 7203–7206. https://​doi.​org/​10.​1109/​IEMBS.​2011.​6091820, NIHMS150003
24.
go back to reference Su H, Cardona DC, Shang W, Camilo A, Cole GA, Rucker DC, Webster RJ, Fischer GS (2012) A MRI-guided concentric tube continuum robot with piezoelectric actuation: a feasibility study. In: Proceedings - IEEE international conference on robotics and automation. https://doi.org/10.1109/ICRA.2012.6224550, 15334406, pp 1939–1945 Su H, Cardona DC, Shang W, Camilo A, Cole GA, Rucker DC, Webster RJ, Fischer GS (2012) A MRI-guided concentric tube continuum robot with piezoelectric actuation: a feasibility study. In: Proceedings - IEEE international conference on robotics and automation. https://​doi.​org/​10.​1109/​ICRA.​2012.​6224550, 15334406, pp 1939–1945
31.
go back to reference Xu R, Yurkewich A, Patel RV (2016b) Shape sensing for torsionally compliant concentric-tube robots. In: Gannot I (ed) Optical fibers and sensors for medical diagnostics and treatment applications XVI. https://doi.org/10.1117/12.2213128, vol 9702, p 97020V Xu R, Yurkewich A, Patel RV (2016b) Shape sensing for torsionally compliant concentric-tube robots. In: Gannot I (ed) Optical fibers and sensors for medical diagnostics and treatment applications XVI. https://​doi.​org/​10.​1117/​12.​2213128, vol 9702, p 97020V
32.
Metadata
Title
Tip estimation approach for concentric tube robots using 2D ultrasound images and kinematic model
Authors
Zihao Li
Xing Yang
Shuang Song
Li Liu
Max Q.-H. Meng
Publication date
22-06-2021
Publisher
Springer Berlin Heidelberg
Published in
Medical & Biological Engineering & Computing / Issue 7-8/2021
Print ISSN: 0140-0118
Electronic ISSN: 1741-0444
DOI
https://doi.org/10.1007/s11517-021-02369-z

Other articles of this Issue 7-8/2021

Medical & Biological Engineering & Computing 7-8/2021 Go to the issue

Premium Partner