Skip to main content
Top
Published in: Microsystem Technologies 11/2017

25-11-2016 | Technical Paper

Design of a moving bed for a radiation therapy system with multiple linear accelerators

Authors: Dongwook Kim, Jun-Ho Yoon, No-Cheol Park, Seungho Kim, Yeong-Geol Bae, Kyung-Min Jeong

Published in: Microsystem Technologies | Issue 11/2017

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Radiation therapy system is preferred to surgery for the most cancer because it is noninvasive. In radiotherapy, respiratory motion is an obstacle of high-precision therapy. The patient support system (PSS) is a method to compensate respiratory motion without increasing treatment time. But treatment time could not be decreased dramatically with conventional PSS because it increases duty cycle of linear accelerator (LINAC). To apply multiple LINACs, the conventional PSS is not suitable as the structure of PSS interrupt workspace of LINACs. In this study, we designed a new moving bed to apply multiple LINACs as well under the bed. A force distribution method and dynamics of the bed were identified. Rigid body simulation model was made to verify that the bed can operate well as expected. And a real size model was manufactured on a basis of the simulation model. Experiments were conducted to identify that the bed can move in desired objectives.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
go back to reference D’Souza WD, Naqvi SA, Yu CX (2005) Real-time intra-fraction-motion tracking using the treatment couch: a feasibility study. Phys Med Biol 50:4021–4033CrossRef D’Souza WD, Naqvi SA, Yu CX (2005) Real-time intra-fraction-motion tracking using the treatment couch: a feasibility study. Phys Med Biol 50:4021–4033CrossRef
go back to reference D’Souza WD, Malinaowski KT, Van Liew S et al (2009) Investigation of motion sickness and inertial stability on a moving couch for intra-faction motion compensation. Med Phys 48:1198–1203 D’Souza WD, Malinaowski KT, Van Liew S et al (2009) Investigation of motion sickness and inertial stability on a moving couch for intra-faction motion compensation. Med Phys 48:1198–1203
go back to reference Depuydt T et al (2011) Geometric accuracy of a novel gimbals based radiation therapy tumor tracking system. Radiother Oncol 98:365–372CrossRef Depuydt T et al (2011) Geometric accuracy of a novel gimbals based radiation therapy tumor tracking system. Radiother Oncol 98:365–372CrossRef
go back to reference George R, Chung T, Vedam SS, Ramakrishnan V, Mohan R, Weiss E, Keall PJ (2006) Audio-visual biofeedback for respiratory-gated radiotherapy: impact of audio instruction and audio-visual biofeedback on respiratory-gated radiotherapy. Int J Radiat Oncol Biol Phys 65:924–933CrossRef George R, Chung T, Vedam SS, Ramakrishnan V, Mohan R, Weiss E, Keall PJ (2006) Audio-visual biofeedback for respiratory-gated radiotherapy: impact of audio instruction and audio-visual biofeedback on respiratory-gated radiotherapy. Int J Radiat Oncol Biol Phys 65:924–933CrossRef
go back to reference Giraud P, Houle A (2010) Respiratory gating for radiotherapy: main technical aspects and clinical benefits. Bull Cancer 97:847–856 Giraud P, Houle A (2010) Respiratory gating for radiotherapy: main technical aspects and clinical benefits. Bull Cancer 97:847–856
go back to reference Haas OCL, Paluszczyszyn D, Ruta M, Skworcow P (2011) Motion prediction and control for patient motion compensation in radiotherapy. In: Proceedings of the 18th IFAC World Congress (Milano, Italy), pp 5985–5990. http://www.Ifac-Papersonline.net. Accessed 16 May 2016 Haas OCL, Paluszczyszyn D, Ruta M, Skworcow P (2011) Motion prediction and control for patient motion compensation in radiotherapy. In: Proceedings of the 18th IFAC World Congress (Milano, Italy), pp 5985–5990. http://​www.​Ifac-Papersonline.​net. Accessed 16 May 2016
go back to reference Haas OCL, Skworcow P, Paluszczyszyn D, Sahih A et al (2012) Couch-based motion compensation: modeling, simulation and real-time experiments. Phys Med Biol 57:5787–5807CrossRef Haas OCL, Skworcow P, Paluszczyszyn D, Sahih A et al (2012) Couch-based motion compensation: modeling, simulation and real-time experiments. Phys Med Biol 57:5787–5807CrossRef
go back to reference Herrmann C, Ma L, Schilling L (2011) Model predictive control for tumor motion compensation in robot assisted radiotherapy. In: Proceedings of the 18th IFAC World Congress (Milano, Italy), pp 5968–5973. http://www.Ifac-Papersonline.net. Accessed 27 May 2016 Herrmann C, Ma L, Schilling L (2011) Model predictive control for tumor motion compensation in robot assisted radiotherapy. In: Proceedings of the 18th IFAC World Congress (Milano, Italy), pp 5968–5973. http://​www.​Ifac-Papersonline.​net. Accessed 27 May 2016
go back to reference Hoogeman M, Prévost JB, Nuyttens J, Pöll J, Levendag P, Heijmen B (2009) Clinical accuracy of the respiratory tumor tracking system of the cyberknife: assessment by analysis of log files. Int J Radiat Oncol Biol Phys 74:297–303CrossRef Hoogeman M, Prévost JB, Nuyttens J, Pöll J, Levendag P, Heijmen B (2009) Clinical accuracy of the respiratory tumor tracking system of the cyberknife: assessment by analysis of log files. Int J Radiat Oncol Biol Phys 74:297–303CrossRef
go back to reference Karuss A, Nil SN, Tacke M, Oelfke U (2011) Electromagnetic real-time tumor position monitoring and dynamic multileaf collimator tracking using a siemens 160 MLC: geometric and dosimetric accuracy of an integrated system. Int J Radiat Oncol Biol Phys 79:579–587CrossRef Karuss A, Nil SN, Tacke M, Oelfke U (2011) Electromagnetic real-time tumor position monitoring and dynamic multileaf collimator tracking using a siemens 160 MLC: geometric and dosimetric accuracy of an integrated system. Int J Radiat Oncol Biol Phys 79:579–587CrossRef
go back to reference Murphy MJ, Eidens R, Vertaschitsch E, Wright JN (2008) The effect of transponder motion on the accuracy of the calypso electromagnetic localization system. Int J Radiat Oncol Biol Phys 72:295–299CrossRef Murphy MJ, Eidens R, Vertaschitsch E, Wright JN (2008) The effect of transponder motion on the accuracy of the calypso electromagnetic localization system. Int J Radiat Oncol Biol Phys 72:295–299CrossRef
go back to reference Verellen D, Ridder MD, Storme G (2008) A (short) history of image-guided radiotherapy. Radiother Oncol 86:4–13CrossRef Verellen D, Ridder MD, Storme G (2008) A (short) history of image-guided radiotherapy. Radiother Oncol 86:4–13CrossRef
go back to reference Wong JW, Sharpe MB, Jaffray DA, Kini VR et al (1999) The use of active breathing control (ABC) to reduce margin for breathing motion. Int J Radiat Oncol Biol Phys 44:911–919CrossRef Wong JW, Sharpe MB, Jaffray DA, Kini VR et al (1999) The use of active breathing control (ABC) to reduce margin for breathing motion. Int J Radiat Oncol Biol Phys 44:911–919CrossRef
go back to reference Woo MK, Kim B (2002) An investigation of the reproducibility and usefulness of automatic couch motion in complex radiation therapy techniques. J Appl Clin Med Phys 3:46–50 Woo MK, Kim B (2002) An investigation of the reproducibility and usefulness of automatic couch motion in complex radiation therapy techniques. J Appl Clin Med Phys 3:46–50
Metadata
Title
Design of a moving bed for a radiation therapy system with multiple linear accelerators
Authors
Dongwook Kim
Jun-Ho Yoon
No-Cheol Park
Seungho Kim
Yeong-Geol Bae
Kyung-Min Jeong
Publication date
25-11-2016
Publisher
Springer Berlin Heidelberg
Published in
Microsystem Technologies / Issue 11/2017
Print ISSN: 0946-7076
Electronic ISSN: 1432-1858
DOI
https://doi.org/10.1007/s00542-016-3214-7

Other articles of this Issue 11/2017

Microsystem Technologies 11/2017 Go to the issue

Foreword

Foreword