The aim of this study was to determine whether multiple use cellulosic medical textiles (cotton blends, Tencel®) could provide protection against contamination after sterilization, regardless of the barrier system of only qualified materials, as per EN 868-2, used in the process. New methods for testing permeability and durability of the microbial barrier cellulosic textiles were developed. The most resistant endospores of two apathogenic bacteria of the Bacilllus genus (Geobacillus stearothermophilus and Bacillus atrophaeus) were used. Testing was conducted after 1, 10, 20, 30 and 50 washing and sterilization cycles under real hospital conditions of the University Hospital Centre Zagreb. The retention period of the microbial barrier of the diagonally packaged packages (one layer; EN ISO 11607-1:2009) after sterilization was tested after the time period of 1, 2 and 3 months of storage under controlled conditions. Bacterial permeability occurred in cellulosic medical textiles when they were contaminated with an extremely high quantity of aerobe bacterial spores. During the testing of microbial barrier durability, the package remained uncontaminated after 1, 2 and 3 months of storage. Medical cellulose textiles used under real hospital conditions functioned properly as a microbial barrier system after 50 cycles of washing and sterilization and 3 months of storage, as the sterilized content was not contaminated at all; they could be used as a microbe barrier system for packing in sterilization, regardless of the fact that they did not meet the standard EN 868-02:2009 Packaging materials for terminally sterilized medical devices. Part 2: sterilization wrap—requirements and test methods or the International standard, for example EN ISO 11607-1:2009 Packaging for terminally sterilized medical devices, part 1: requirements for materials, sterile barrier systems and packaging systems.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Literature
go back to reference American Society for Testing and Materials (1997) F1671-97b standard test method for resistance of materials used in protective clothing to penetration by blood borne pathogens using phi-x174 bacteriophage penetration as a test system. ASTM, West Conshohocken American Society for Testing and Materials (1997) F1671-97b standard test method for resistance of materials used in protective clothing to penetration by blood borne pathogens using phi-x174 bacteriophage penetration as a test system. ASTM, West Conshohocken
go back to reference American Society for Testing and Materials (1998) F1670-98 standard test method for resistance of materials used in protective clothing to penetration by synthetic blood. ASTM, West Conshohocken American Society for Testing and Materials (1998) F1670-98 standard test method for resistance of materials used in protective clothing to penetration by synthetic blood. ASTM, West Conshohocken
go back to reference Beck WC (1963) Aseptic barriers in surgery: their present status. Arch Surg 87(2):288–296CrossRef Beck WC (1963) Aseptic barriers in surgery: their present status. Arch Surg 87(2):288–296CrossRef
go back to reference Belkin NL (1980) Textiles as aseptic barriers: the past, present, and future. Med Instrum 14(4):233–236 Belkin NL (1980) Textiles as aseptic barriers: the past, present, and future. Med Instrum 14(4):233–236
go back to reference Belkin NL (1988) Aseptic barrier materials for surgical gowns and drapes. AORN J 47(2):572–576CrossRef Belkin NL (1988) Aseptic barrier materials for surgical gowns and drapes. AORN J 47(2):572–576CrossRef
go back to reference Belkin NL (1994) The new American society for testing and materials tests: all that glitters is not gold. Am J Infect Control 22:172–176CrossRef Belkin NL (1994) The new American society for testing and materials tests: all that glitters is not gold. Am J Infect Control 22:172–176CrossRef
go back to reference Belkin NL (2002a) Surgical gowns and drapes: just how necessary are they? Text Rent 72:66–73 Belkin NL (2002a) Surgical gowns and drapes: just how necessary are they? Text Rent 72:66–73
go back to reference Belkin NL (2002b) A historical review of barrier materials. AORN J 76(4):648–653CrossRef Belkin NL (2002b) A historical review of barrier materials. AORN J 76(4):648–653CrossRef
go back to reference Bojic-Turcic V (1994) Sterilization and disinfection in medicine. Medicinska naklada, Medicom, Zagreb. ISBN: 953-176-024-1 Bojic-Turcic V (1994) Sterilization and disinfection in medicine. Medicinska naklada, Medicom, Zagreb. ISBN: 953-176-024-1
go back to reference Borkow G, Gabbay J (2008) Biocidal textiles can help fight nosocomial infections. Med Hypotheses 70:990–994CrossRef Borkow G, Gabbay J (2008) Biocidal textiles can help fight nosocomial infections. Med Hypotheses 70:990–994CrossRef
go back to reference EN ISO 11607-1:2009 Packaging for terminally sterilized medical devices. Part 1: requirements for materials, sterile barrier systems and packaging systems EN ISO 11607-1:2009 Packaging for terminally sterilized medical devices. Part 1: requirements for materials, sterile barrier systems and packaging systems
go back to reference EN 868-02:2009 Packaging materials for terminally sterilized medical devices. Part 2: sterilization wrap—requirements and test methods or the International standard for example EN 868-02:2009 Packaging materials for terminally sterilized medical devices. Part 2: sterilization wrap—requirements and test methods or the International standard for example
go back to reference Enko MT (2009) Sterile supply packaging. WFHSS-ÖGSV Basic Script Enko MT (2009) Sterile supply packaging. WFHSS-ÖGSV Basic Script
go back to reference Fijan S, Šoštar-Turk S (2012) Hospital textiles, are they a possible vehicle for healthcare-associated infections? Int J Environ Res Public Health 9(9):3330–3343CrossRef Fijan S, Šoštar-Turk S (2012) Hospital textiles, are they a possible vehicle for healthcare-associated infections? Int J Environ Res Public Health 9(9):3330–3343CrossRef
go back to reference Granzow JW, Smith JW, Nichols RL, Waterman RS, Muzik AC (1998) Evaluation of the protective value of hospital gowns against blood strike-through and methicillin-resistant Staphylococcus aureus penetration. Am J Infect Control 26(2):85–93CrossRef Granzow JW, Smith JW, Nichols RL, Waterman RS, Muzik AC (1998) Evaluation of the protective value of hospital gowns against blood strike-through and methicillin-resistant Staphylococcus aureus penetration. Am J Infect Control 26(2):85–93CrossRef
go back to reference Lankester BJ, Bartlett GE, Garneti N, Blom AW, Bowker KE, Bannister GC (2002) Direct measurement of bacterial penetration through surgical gowns: a new method. J Hosp Infect 50(4):281–285CrossRef Lankester BJ, Bartlett GE, Garneti N, Blom AW, Bowker KE, Bannister GC (2002) Direct measurement of bacterial penetration through surgical gowns: a new method. J Hosp Infect 50(4):281–285CrossRef
go back to reference Leonas KK (1998) Effect of laundering on the barrier properties of reusable surgical gown fabrics. Am J Infect Control 26:495–501CrossRef Leonas KK (1998) Effect of laundering on the barrier properties of reusable surgical gown fabrics. Am J Infect Control 26:495–501CrossRef
go back to reference Rutala WA, Weber DJ (2001) A review of single use and reusable gowns and drapers in health care. Infect Control Hosp Epidemiol 22(4):248–257CrossRef Rutala WA, Weber DJ (2001) A review of single use and reusable gowns and drapers in health care. Infect Control Hosp Epidemiol 22(4):248–257CrossRef
go back to reference Stephens-Borg K (2008) Surgical dressings and turbulent years of cotton industry. J Perioper Pract 18(7):305–306 Stephens-Borg K (2008) Surgical dressings and turbulent years of cotton industry. J Perioper Pract 18(7):305–306
Metadata
Title
Do multi-use cellulosic textiles provide safe protection against the contamination of sterilized items?
Authors
B. Rogina-Car
A. Budimir
V. Turcic
D. Katovic
Publication date
01-06-2014
Publisher
Springer Netherlands
Published in
Cellulose / Issue 3/2014
Print ISSN: 0969-0239
Electronic ISSN: 1572-882X
DOI
https://doi.org/10.1007/s10570-014-0199-1

Other articles of this Issue 3/2014

Cellulose 3/2014 Go to the issue