Abstract

The overwhelming evidence of global warming caused by human activities documents both contemporary impacts on human life but also extraordinary future risks are also assisted with it. Accretion of global temperatures engenders the extensive use of air conditioning devices to make the surrounding livable in the summer season. Energy consumption for air conditioning is also palpable by the evidence that this industry is the 2nd largest power-consuming sector in the consumer field. High temperatures also affect the performance of the air conditioning system by decreasing their energy efficiency ratio (EER) and cooling capacity (QC). Modifications are made in such a way to lower down the temperature of the surrounding by the use of a honeycomb wet pad which uses evaporative cooling with condensate of the indoor side. Experiments were made to observe the difference in performance efficiency, with modification and sans modification, by operating separately at 40–50 °C temperatures. Results were evident that condensate assisted evaporative cooling shows improvement in cooling capacity by 19% and a reduction in power consumption (P) by 13% as compare to the conventional system. A huge increase in the energy efficiency ratio of 36% was observed with the use of the modified system. The things used for the modification are cheaper and easily available in the market.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Arto, I.; Capellán-Pérez, I.; Lago, R.; Bueno, G.; Bermejo, R.: The energy requirements of a developed world. Energy Sustain. Dev. 33, 1–13 (2016)CrossRef Arto, I.; Capellán-Pérez, I.; Lago, R.; Bueno, G.; Bermejo, R.: The energy requirements of a developed world. Energy Sustain. Dev. 33, 1–13 (2016)CrossRef
3.
go back to reference Us department of energy residential energy consumption survey (2009) Us department of energy residential energy consumption survey (2009)
4.
go back to reference Nagata, T.; Yasin, J.; Kishi, Y.; Wada, A.J.H.R.: Development of the inverter air conditioner for Southeast Asia in FY2014. Hitachi Rev. 64(2), 153 (2015) Nagata, T.; Yasin, J.; Kishi, Y.; Wada, A.J.H.R.: Development of the inverter air conditioner for Southeast Asia in FY2014. Hitachi Rev. 64(2), 153 (2015)
5.
go back to reference Hamza, A.: Ac Production Goes up 24% this Year, Amid Soaring Demand, in Daily Times. Sindh, Pakistan (2018) Hamza, A.: Ac Production Goes up 24% this Year, Amid Soaring Demand, in Daily Times. Sindh, Pakistan (2018)
6.
go back to reference ISO.: International standard iso 5151: Non-ducted air conditioners and heat pumps—testing and rating for performance, Organización Internacional de Normalización (2010) ISO.: International standard iso 5151: Non-ducted air conditioners and heat pumps—testing and rating for performance, Organización Internacional de Normalización (2010)
7.
go back to reference Chaktranond, C.; Doungsong, P.: An experimental evaluation of energy saving in a split-type air conditioner with evaporative cooling systems. Int. Trans. J. Eng. Manag. Appl. Sci. Technol. 1(1), 009–018 (2010) Chaktranond, C.; Doungsong, P.: An experimental evaluation of energy saving in a split-type air conditioner with evaporative cooling systems. Int. Trans. J. Eng. Manag. Appl. Sci. Technol. 1(1), 009–018 (2010)
9.
go back to reference Chen, W.-H.; Mo, H.-E.; Teng, T.-P.: Performance improvement of a split air conditioner by using an energy saving device. Energy Build. 174, 380–387 (2018)CrossRef Chen, W.-H.; Mo, H.-E.; Teng, T.-P.: Performance improvement of a split air conditioner by using an energy saving device. Energy Build. 174, 380–387 (2018)CrossRef
10.
go back to reference ISO.: Air-cooled air conditioners and air-to-air heat pumps—testing and calculating methods for seasonal performance factors—part 1: cooling seasonal performance factor. p. 26 (2013) ISO.: Air-cooled air conditioners and air-to-air heat pumps—testing and calculating methods for seasonal performance factors—part 1: cooling seasonal performance factor. p. 26 (2013)
11.
go back to reference Chua, K.J.; Chou, S.K.; Yang, W.M.; Yan, J.: Achieving better energy-efficient air conditioning–a review of technologies and strategies. Appl. Energy 104, 87–104 (2013)CrossRef Chua, K.J.; Chou, S.K.; Yang, W.M.; Yan, J.: Achieving better energy-efficient air conditioning–a review of technologies and strategies. Appl. Energy 104, 87–104 (2013)CrossRef
12.
go back to reference Chaudhari, B.D.; Sonawane, T.R.; Patil, S.M.; Dube, A.: A review on evaporative cooling technology. Int. J. Res. Advent Technol. 3(2), 88–96 (2015) Chaudhari, B.D.; Sonawane, T.R.; Patil, S.M.; Dube, A.: A review on evaporative cooling technology. Int. J. Res. Advent Technol. 3(2), 88–96 (2015)
13.
go back to reference Watt, J.: Evaporative air Conditioning Handbook. Springer, US (2012) Watt, J.: Evaporative air Conditioning Handbook. Springer, US (2012)
14.
go back to reference Otterbein, R.J.H.E.: Installing and maintaining evaporative coolers. 13(3) (1996) Otterbein, R.J.H.E.: Installing and maintaining evaporative coolers. 13(3) (1996)
15.
go back to reference Joshi, P.B.: Evaporative cooling method: A literature review IJSRD. Int. J. Sci. Res. Dev. 5(01), 747–751 (2017) Joshi, P.B.: Evaporative cooling method: A literature review IJSRD. Int. J. Sci. Res. Dev. 5(01), 747–751 (2017)
16.
go back to reference Jain, D.J.B.: Development and testing of two-stage evaporative cooler. Build. Environ. 42(7), 2549–2554 (2007)CrossRef Jain, D.J.B.: Development and testing of two-stage evaporative cooler. Build. Environ. 42(7), 2549–2554 (2007)CrossRef
17.
go back to reference Porumb, B.; Ungureşan, P.; Tutunaru, L.F.; Şerban, A.; Bălan, M.J.E.P.: A review of indirect evaporative cooling technology. Energy Procedia 85, 461–471 (2016)CrossRef Porumb, B.; Ungureşan, P.; Tutunaru, L.F.; Şerban, A.; Bălan, M.J.E.P.: A review of indirect evaporative cooling technology. Energy Procedia 85, 461–471 (2016)CrossRef
18.
go back to reference Khmamas, F.: Improving the environmental cooling for air-coolers by using the indirect-cooling method. ARPN J. Eng. Appl. Sci. 5(2), 66–73 (2012) Khmamas, F.: Improving the environmental cooling for air-coolers by using the indirect-cooling method. ARPN J. Eng. Appl. Sci. 5(2), 66–73 (2012)
19.
go back to reference Amer, O.; Boukhanouf, R.; Ibrahim, H.J.: A review of evaporative cooling technologies. Int. J. Environ. Sci. Develop. 6(2), 111 (2015)CrossRef Amer, O.; Boukhanouf, R.; Ibrahim, H.J.: A review of evaporative cooling technologies. Int. J. Environ. Sci. Develop. 6(2), 111 (2015)CrossRef
20.
go back to reference Jassim, L.I.: Enhancement the performance of condenser of split type air conditioning system by using evaporative cooling. Al-Ma’mon Coll. J. 17, 230–246 (2011) Jassim, L.I.: Enhancement the performance of condenser of split type air conditioning system by using evaporative cooling. Al-Ma’mon Coll. J. 17, 230–246 (2011)
21.
go back to reference Ajiambo, F.; Nzila, C.; Namango, S.; Deshmukh Ashvini, B.; Shelke Pooja, P.; Kokare Sayali, A.; Taware Saksha, S.; Anand, A.; Parasar, A.; Prabhakar, A.: International research journal of engineering and technology (irjet) Ajiambo, F.; Nzila, C.; Namango, S.; Deshmukh Ashvini, B.; Shelke Pooja, P.; Kokare Sayali, A.; Taware Saksha, S.; Anand, A.; Parasar, A.; Prabhakar, A.: International research journal of engineering and technology (irjet)
22.
go back to reference Aglawe, K.; Matey, M.; Gudadhe, N.: Experimental analysis of window air conditioner using evaporative cooling. Int. J. Eng. Res. Technol. 2, 1–6 (2013) Aglawe, K.; Matey, M.; Gudadhe, N.: Experimental analysis of window air conditioner using evaporative cooling. Int. J. Eng. Res. Technol. 2, 1–6 (2013)
23.
go back to reference Huynh, T.M.T., A study on an eco-friendly and high-performance cooling system using evapo-transpiration (本文). 慶應義塾大学 (2014) Huynh, T.M.T., A study on an eco-friendly and high-performance cooling system using evapo-transpiration (本文). 慶應義塾大学 (2014)
24.
go back to reference Prajapati, M.: Enhancement the performance of condenser of split type air conditioning system by using evaporative cooling: a review. Int. J. Eng. Sci. Res. Technol. p. 6 (2014) Prajapati, M.: Enhancement the performance of condenser of split type air conditioning system by using evaporative cooling: a review. Int. J. Eng. Sci. Res. Technol. p. 6 (2014)
25.
go back to reference Wang, T.; Sheng, C.; Nnanna, A.A.: Experimental investigation of air conditioning system using evaporative cooling condenser. Energy Build. 81, 435–443 (2014)CrossRef Wang, T.; Sheng, C.; Nnanna, A.A.: Experimental investigation of air conditioning system using evaporative cooling condenser. Energy Build. 81, 435–443 (2014)CrossRef
26.
go back to reference Islam, M.; Jahangeer, K.; Chua, K.: Experimental and numerical study of an evaporatively-cooled condenser of air-conditioning systems. Energy 87, 390–399 (2015)CrossRef Islam, M.; Jahangeer, K.; Chua, K.: Experimental and numerical study of an evaporatively-cooled condenser of air-conditioning systems. Energy 87, 390–399 (2015)CrossRef
27.
go back to reference Alhamdo, M.H.; Theeb, M.A.; Abdulhameed, J.J.: Using evaporative cooling methods for improving performance of an air-cooled condenser. Univ. J. Mech. Eng. 3(3), 94–106 (2015)CrossRef Alhamdo, M.H.; Theeb, M.A.; Abdulhameed, J.J.: Using evaporative cooling methods for improving performance of an air-cooled condenser. Univ. J. Mech. Eng. 3(3), 94–106 (2015)CrossRef
28.
go back to reference Kulkami, M.; Khandagale, A.; Singh, P.; Choudhary, S.; Sharma, R.: Experimental investigations of evaporative-cooled condenser split air conditioner. Int. J. Eng. Sci. Comput. (IJESC) 6, 7–19 (2016) Kulkami, M.; Khandagale, A.; Singh, P.; Choudhary, S.; Sharma, R.: Experimental investigations of evaporative-cooled condenser split air conditioner. Int. J. Eng. Sci. Comput. (IJESC) 6, 7–19 (2016)
29.
go back to reference Soylu, S.K.; Atmaca, I.; Doğan, A.: Investigation of evaporative cooling effectiveness on the performance of air–cooled chillers. Online J. Sci. Technol. 6(3), 3–39 (2016) Soylu, S.K.; Atmaca, I.; Doğan, A.: Investigation of evaporative cooling effectiveness on the performance of air–cooled chillers. Online J. Sci. Technol. 6(3), 3–39 (2016)
30.
go back to reference Kabeel, A.; El-Samadony, Y.; Khiera, M.: Performance evaluation of energy efficient evaporatively air-cooled chiller. Appl. Therm. Eng. 122, 204–213 (2017)CrossRef Kabeel, A.; El-Samadony, Y.; Khiera, M.: Performance evaluation of energy efficient evaporatively air-cooled chiller. Appl. Therm. Eng. 122, 204–213 (2017)CrossRef
31.
go back to reference Mohammed, J.A.-K.; Mohammed, F.M.; Jabbar, M.A.-S.J.A.T.E.: Investigation of high performance split air conditioning system by using hybrid pid controller. Appl. Therm. Eng. 129, 1240–1251 (2018)CrossRef Mohammed, J.A.-K.; Mohammed, F.M.; Jabbar, M.A.-S.J.A.T.E.: Investigation of high performance split air conditioning system by using hybrid pid controller. Appl. Therm. Eng. 129, 1240–1251 (2018)CrossRef
32.
go back to reference Huang, X.; Li, X.; Sheng, X.; Su, X.J.E.P.: The research of the key problem of evaporative cooling system in dry areas subway. Energy Procedia 61, 1965–1968 (2014)CrossRef Huang, X.; Li, X.; Sheng, X.; Su, X.J.E.P.: The research of the key problem of evaporative cooling system in dry areas subway. Energy Procedia 61, 1965–1968 (2014)CrossRef
33.
go back to reference Abraham, J.; Chitharthan, R.K.: Performance evaluation of air-conditioning system with evaporative cooled condenser. Int. J. Appl. Eng. Res. 10, 11356–11361 (2015) Abraham, J.; Chitharthan, R.K.: Performance evaluation of air-conditioning system with evaporative cooled condenser. Int. J. Appl. Eng. Res. 10, 11356–11361 (2015)
34.
go back to reference Sawant, A.P.; Agrawal, N.; Nanda, P.: Performance assessment of an evaporative cooling-assisted window air conditioner. Int. J. Low-Carbon Technol. 7(2), 128–136 (2011)CrossRef Sawant, A.P.; Agrawal, N.; Nanda, P.: Performance assessment of an evaporative cooling-assisted window air conditioner. Int. J. Low-Carbon Technol. 7(2), 128–136 (2011)CrossRef
35.
go back to reference Martínez, P.; Ruiz, J.; Cutillas, C.; Martínez, P.; Kaiser, A.; Lucas, M.: Experimental study on energy performance of a split air-conditioner by using variable thickness evaporative cooling pads coupled to the condenser. Appl. Therm. Eng. 105, 1041–1050 (2016)CrossRef Martínez, P.; Ruiz, J.; Cutillas, C.; Martínez, P.; Kaiser, A.; Lucas, M.: Experimental study on energy performance of a split air-conditioner by using variable thickness evaporative cooling pads coupled to the condenser. Appl. Therm. Eng. 105, 1041–1050 (2016)CrossRef
36.
go back to reference Martínez, P.; Ruiz, J.; Martínez, P.; Kaiser, A.; Lucas, M.J.A.T.E.: Experimental study of the energy and exergy performance of a plastic mesh evaporative pad used in air conditioning applications. 138, p. 675–685 (2018) Martínez, P.; Ruiz, J.; Martínez, P.; Kaiser, A.; Lucas, M.J.A.T.E.: Experimental study of the energy and exergy performance of a plastic mesh evaporative pad used in air conditioning applications. 138, p. 675–685 (2018)
37.
go back to reference Noutcha, M.A.E.: Quantity and quality of water condensate from air conditioners and its potential uses at the university of port harcourt, nigeria) m aline e noutcha, oramabo damiete, mathew johnny jr., oparanozie ngozi, chinwendum u ezera, samuel n okiwelu Noutcha, M.A.E.: Quantity and quality of water condensate from air conditioners and its potential uses at the university of port harcourt, nigeria) m aline e noutcha, oramabo damiete, mathew johnny jr., oparanozie ngozi, chinwendum u ezera, samuel n okiwelu
38.
go back to reference Sabnis, A.; Kale, M.; Dhanorkar, M.; Kale, S.P.: Quality testing of air conditioner condensate and its potential in water conservation. J. Water Resour. Protect. 12(02), 93 (2020)CrossRef Sabnis, A.; Kale, M.; Dhanorkar, M.; Kale, S.P.: Quality testing of air conditioner condensate and its potential in water conservation. J. Water Resour. Protect. 12(02), 93 (2020)CrossRef
39.
go back to reference Seckler, D.; Barker, R.; Amarasinghe, U.: Water scarcity in the twenty-first century. Int. J. Water Resour. Dev. 15(1–2), 29–42 (1999)CrossRef Seckler, D.; Barker, R.; Amarasinghe, U.: Water scarcity in the twenty-first century. Int. J. Water Resour. Dev. 15(1–2), 29–42 (1999)CrossRef
40.
go back to reference Ali, M.A.; Saifur, S.; Ali, M.A.J.G.S.T.J.: Quantification of condensate water generated from air conditioning system. 6, p. 44–56 (2018) Ali, M.A.; Saifur, S.; Ali, M.A.J.G.S.T.J.: Quantification of condensate water generated from air conditioning system. 6, p. 44–56 (2018)
41.
go back to reference Akram, M.W.; Mursalin, R.; Hassan, M.M.; Islam, M.R.; Choudhury, S.K: Recycling of condensed water from an air conditioning unit. In: 2018 International Conference on Computer, Communication, Chemical, Material and Electronic Engineering (IC4ME2). IEEE (2018) Akram, M.W.; Mursalin, R.; Hassan, M.M.; Islam, M.R.; Choudhury, S.K: Recycling of condensed water from an air conditioning unit. In: 2018 International Conference on Computer, Communication, Chemical, Material and Electronic Engineering (IC4ME2). IEEE (2018)
42.
go back to reference Ardita, I.; Subagia, I.: The application of condensate water as an additional cooling media intermittently in condenser of a split air conditioning. in Journal of Physics: Conference Series. IOP Publishing (2018) Ardita, I.; Subagia, I.: The application of condensate water as an additional cooling media intermittently in condenser of a split air conditioning. in Journal of Physics: Conference Series. IOP Publishing (2018)
43.
go back to reference Du, G.; Zhou, S.; Zhou, Y.; Liu, X.J.P.E.: Design of performance testing system for hvac based on enthalpy difference method. 205, 2156–2163 (2017) Du, G.; Zhou, S.; Zhou, Y.; Liu, X.J.P.E.: Design of performance testing system for hvac based on enthalpy difference method. 205, 2156–2163 (2017)
44.
go back to reference Sanhueza, S.M.R.; Tofoli, F.L.; de Albuquerque, F.L.; de Oliveira, J.C.; G.C.I.T.o.P.S: Guimaraes, analysis and evaluation of residential air conditioners for power system studies. 22(2), 706–716 (2007) Sanhueza, S.M.R.; Tofoli, F.L.; de Albuquerque, F.L.; de Oliveira, J.C.; G.C.I.T.o.P.S: Guimaraes, analysis and evaluation of residential air conditioners for power system studies. 22(2), 706–716 (2007)
45.
go back to reference Commission, I.E.; IOF Standardization; Iso/iec guide 98–3: Uncertainty of measurement. Part 3: Guide to the expressión of uncertainty in measurement (gum :1995). Partie 3: Guide pour l'expression de l'incertitude de mesure (gum: 1995). ISO (2008) Commission, I.E.; IOF Standardization; Iso/iec guide 98–3: Uncertainty of measurement. Part 3: Guide to the expressión of uncertainty in measurement (gum :1995). Partie 3: Guide pour l'expression de l'incertitude de mesure (gum: 1995). ISO (2008)
Metadata
Title
Energy Efficiency Improvement of the Split Air Conditioner Through Condensate Assisted Evaporative Cooling
Authors
Majid Ramzan
Muhammad Sajid Kamran
Muhammad Wajid Saleem
Hassan Ali
Mudather Ibrahim Mudather Zeinelabdeen
Publication date
22-03-2021
Publisher
Springer Berlin Heidelberg
Published in
Arabian Journal for Science and Engineering / Issue 8/2021
Print ISSN: 2193-567X
Electronic ISSN: 2191-4281
DOI
https://doi.org/10.1007/s13369-021-05494-x

Other articles of this Issue 8/2021

Arabian Journal for Science and Engineering 8/2021 Go to the issue

Research Article-Mechanical Engineering

Estimation of Optimal Cone Index by Using Neural Networks

Premium Partners