Skip to main content
Top
Published in: International Journal of Computer Assisted Radiology and Surgery 6/2017

07-03-2017 | Original Article

Geometric modeling of hepatic arteries in 3D ultrasound with unsupervised MRA fusion during liver interventions

Authors: Maxime Gérard, François Michaud, Alexandre Bigot, An Tang, Gilles Soulez, Samuel Kadoury

Published in: International Journal of Computer Assisted Radiology and Surgery | Issue 6/2017

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Purpose

Modulating the chemotherapy injection rate with regard to blood flow velocities in the tumor-feeding arteries during intra-arterial therapies may help improve liver tumor targeting while decreasing systemic exposure. These velocities can be obtained noninvasively using Doppler ultrasound (US). However, small vessels situated in the liver are difficult to identify and follow in US. We propose a multimodal fusion approach that non-rigidly registers a 3D geometric mesh model of the hepatic arteries obtained from preoperative MR angiography (MRA) acquisitions with intra-operative 3D US imaging.

Methods

The proposed fusion tool integrates 3 imaging modalities: an arterial MRA, a portal phase MRA and an intra-operative 3D US. Preoperatively, the arterial phase MRA is used to generate a 3D model of the hepatic arteries, which is then non-rigidly co-registered with the portal phase MRA. Once the intra-operative 3D US is acquired, we register it with the portal MRA using a vessel-based rigid initialization followed by a non-rigid registration using an image-based metric based on linear correlation of linear combination. Using the combined non-rigid transformation matrices, the 3D mesh model is fused with the 3D US.

Results

3D US and multi-phase MRA images acquired from 10 porcine models were used to test the performance of the proposed fusion tool. Unimodal registration of the MRA phases yielded a target registration error (TRE) of \(1.2\pm 0.6\) mm. Initial rigid alignment of the portal MRA and 3D US yielded a mean TRE of \(8.6\pm 3.0\) mm, which was significantly reduced to \(4.0\pm 1.0\) mm (\(p = 0.002\)) after affine image-based registration. The following deformable registration step allowed for further decrease of the mean TRE to \(3.9\pm 1.1\) mm.

Conclusion

The proposed tool could facilitate visualization and localization of these vessels when using 3D US intra-operatively for either intravascular or percutaneous interventions to avoid vessel perforation.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Chen HS, Gross JF (1980) Intra-arterial infusion of anticancer drugs: theoretic aspects of drug delivery and review of responses. Cancer Treat Rep 64(1):31–40PubMed Chen HS, Gross JF (1980) Intra-arterial infusion of anticancer drugs: theoretic aspects of drug delivery and review of responses. Cancer Treat Rep 64(1):31–40PubMed
2.
go back to reference Varela M, Real MI, Burrel M, Forner A, Sala M, Brunet M, Ayuso C, Castells L, Montañá X, Llovet JM, Bruix J (2007) Chemoembolization of hepatocellular carcinoma with drug eluting beads: efficacy and doxorubicin pharmacokinetics. J Hepatol 46(3):474–481CrossRefPubMed Varela M, Real MI, Burrel M, Forner A, Sala M, Brunet M, Ayuso C, Castells L, Montañá X, Llovet JM, Bruix J (2007) Chemoembolization of hepatocellular carcinoma with drug eluting beads: efficacy and doxorubicin pharmacokinetics. J Hepatol 46(3):474–481CrossRefPubMed
3.
go back to reference Draghi F, Rapaccini GL, Fachinetti C, de Matthaeis N, Battaglia S, Abbattista T, Busilacchi (2007) Ultrasound examination of the liver. J Ultrasound 10:5–11CrossRefPubMedPubMedCentral Draghi F, Rapaccini GL, Fachinetti C, de Matthaeis N, Battaglia S, Abbattista T, Busilacchi (2007) Ultrasound examination of the liver. J Ultrasound 10:5–11CrossRefPubMedPubMedCentral
4.
go back to reference Chen SJ, Reinertsen I, Coupé P, Yan CX, Mercier L, Del Maestro DR, Collins DL (2012) Validation of hybrid Doppler ultrasound vessel-based registration algorithm for neurosurgery. Int J Comput Assist Radiol Surg 7(5):667–685CrossRefPubMedPubMedCentral Chen SJ, Reinertsen I, Coupé P, Yan CX, Mercier L, Del Maestro DR, Collins DL (2012) Validation of hybrid Doppler ultrasound vessel-based registration algorithm for neurosurgery. Int J Comput Assist Radiol Surg 7(5):667–685CrossRefPubMedPubMedCentral
5.
go back to reference Penney GP, Blackall JM, Hamady MS, Sabharwal T, Adam A, Hawkes DJ (2004) Registration of freehand 3D ultrasound and magnetic resonance liver images. Med Image Anal 8(1):81–91CrossRefPubMed Penney GP, Blackall JM, Hamady MS, Sabharwal T, Adam A, Hawkes DJ (2004) Registration of freehand 3D ultrasound and magnetic resonance liver images. Med Image Anal 8(1):81–91CrossRefPubMed
6.
go back to reference Milko S, Melvaer EL, Samset E, Kadir T (2009) A novel method for registration of US/MR of the liver based on the analysis of US dynamics. Med Image Comput Assist Interv 12:771–778 Milko S, Melvaer EL, Samset E, Kadir T (2009) A novel method for registration of US/MR of the liver based on the analysis of US dynamics. Med Image Comput Assist Interv 12:771–778
7.
go back to reference Wein W, Ladikos A, Fuerst B, Shah A, Sharma K, Navab N (2013) Global registration of ultrasound to MRI using the \(\text{LC}^2\) metric for enabling neurosurgical guidance. In: Medical image computing and computer-assisted intervention—MICCAI 2013, part I, volume 8149 of lecture notes in computer science. Springer, pp 33–41 Wein W, Ladikos A, Fuerst B, Shah A, Sharma K, Navab N (2013) Global registration of ultrasound to MRI using the \(\text{LC}^2\) metric for enabling neurosurgical guidance. In: Medical image computing and computer-assisted intervention—MICCAI 2013, part I, volume 8149 of lecture notes in computer science. Springer, pp 33–41
8.
go back to reference Fuerst B, Wein W, Müller M, Navab N (2014) Automatic ultrasound-MRI registration for neurosurgery using the 2D and 3D \(\text{ LC }^2\) metric. Med Image Anal 18:1312–1319CrossRefPubMed Fuerst B, Wein W, Müller M, Navab N (2014) Automatic ultrasound-MRI registration for neurosurgery using the 2D and 3D \(\text{ LC }^2\) metric. Med Image Anal 18:1312–1319CrossRefPubMed
9.
go back to reference Rivaz H, Chen SJ, Collins DL (2015) Automatic deformable MR-ultrasound registration for image-guided neurosurgery. IEEE Trans Med Imaging 34(2):366–380CrossRefPubMed Rivaz H, Chen SJ, Collins DL (2015) Automatic deformable MR-ultrasound registration for image-guided neurosurgery. IEEE Trans Med Imaging 34(2):366–380CrossRefPubMed
10.
go back to reference Badoual A, Gerard M, De Leener B, Abi-Jaoudeh N, Kadoury S (2016) 3D vascular path planning of chemo-embolizations using segmented hepatic arteries from MR angiography. In: IEEE 13th international symposium on biomedical imaging (ISBI 2016), pp 225–228 Badoual A, Gerard M, De Leener B, Abi-Jaoudeh N, Kadoury S (2016) 3D vascular path planning of chemo-embolizations using segmented hepatic arteries from MR angiography. In: IEEE 13th international symposium on biomedical imaging (ISBI 2016), pp 225–228
11.
go back to reference Sato Y, Nakajima S, Atsumi H, Koller T, Gerig G, Yoshida S, Kikinis R (1997) 3D multi-scale line filter for segmentation and visualization of curvilinear structures in medical images. In: CVRMed-MRCAS’97, volume 1205 of lecture notes in computer science. Springer, pp 213–222 Sato Y, Nakajima S, Atsumi H, Koller T, Gerig G, Yoshida S, Kikinis R (1997) 3D multi-scale line filter for segmentation and visualization of curvilinear structures in medical images. In: CVRMed-MRCAS’97, volume 1205 of lecture notes in computer science. Springer, pp 213–222
12.
go back to reference De Leener B, Cohen-Adad J, Kadoury S (2015) Automatic segmentation of the spinal cord and spinal canal coupled with vertebral labeling. IEEE Trans Med Imaging 34:1705–1718CrossRefPubMed De Leener B, Cohen-Adad J, Kadoury S (2015) Automatic segmentation of the spinal cord and spinal canal coupled with vertebral labeling. IEEE Trans Med Imaging 34:1705–1718CrossRefPubMed
13.
go back to reference Friman O, Hidennach M, Kühnel C, Peitgen HO (2010) Multiple hypothesis template tracking of small 3D vessel structures. Med Image Anal 14:160–171CrossRefPubMed Friman O, Hidennach M, Kühnel C, Peitgen HO (2010) Multiple hypothesis template tracking of small 3D vessel structures. Med Image Anal 14:160–171CrossRefPubMed
14.
go back to reference Klein S, Staring M, Murphy K, Viergever MA, Pluim JPW (2010) Elastix: a toolbox for intensity based medical image registration. IEEE Trans Med Imaging 29(1):196–205CrossRefPubMed Klein S, Staring M, Murphy K, Viergever MA, Pluim JPW (2010) Elastix: a toolbox for intensity based medical image registration. IEEE Trans Med Imaging 29(1):196–205CrossRefPubMed
15.
go back to reference Shamonin DP, Bron EE, Lelieveldt BPF, Smits M, Klein S, Staring M (2014) Fast parallel image registration on CPU and GPU for diagnostic classification of Alzheimer’s disease. Front Neuroinform 7(50):1–15 Shamonin DP, Bron EE, Lelieveldt BPF, Smits M, Klein S, Staring M (2014) Fast parallel image registration on CPU and GPU for diagnostic classification of Alzheimer’s disease. Front Neuroinform 7(50):1–15
16.
go back to reference Pluim JPW, Maintz JBA, Viergever MA (2003) Mutual information based registration of medical images: a survey. IEEE Trans Med Imaging 22(8):986–1004CrossRefPubMed Pluim JPW, Maintz JBA, Viergever MA (2003) Mutual information based registration of medical images: a survey. IEEE Trans Med Imaging 22(8):986–1004CrossRefPubMed
17.
go back to reference Frangi AF, Niessen WJ, Vincken KL, Viergever MA (1998) Multiscale vessel enhancement filtering. In: Wells WM, Colchester A, Delp SL (eds) Medical image computing and computer-assisted intervention—MICCAI’98, volume 1496 of lecture notes in computer science. Springer, New York, pp 130–137 Frangi AF, Niessen WJ, Vincken KL, Viergever MA (1998) Multiscale vessel enhancement filtering. In: Wells WM, Colchester A, Delp SL (eds) Medical image computing and computer-assisted intervention—MICCAI’98, volume 1496 of lecture notes in computer science. Springer, New York, pp 130–137
18.
go back to reference Powell MJ (2009) The BOBYQA algorithm for bound constrained optimization without derivatives. In: Cambridge report NA2009/06. University of Cambridge Powell MJ (2009) The BOBYQA algorithm for bound constrained optimization without derivatives. In: Cambridge report NA2009/06. University of Cambridge
19.
go back to reference Kadoury S, Zargochev L, Wood BJ, Venkatesan A, Weese J, Jago J, Kruecker J (2012) A model-based registration approach of pre-operative MRI with 3D ultrasound of the liver for Interventional guidance procedures. In: Proceedings of international symposium on biomedical imaging, pp 952–955 Kadoury S, Zargochev L, Wood BJ, Venkatesan A, Weese J, Jago J, Kruecker J (2012) A model-based registration approach of pre-operative MRI with 3D ultrasound of the liver for Interventional guidance procedures. In: Proceedings of international symposium on biomedical imaging, pp 952–955
20.
go back to reference Wein W, Brunke S, Khamene A, Callstrom MR, Navab N (2008) Automatic CT-ultrasound registration for diagnostic imaging and image-guided intervention. Med Image Anal 12:577–585CrossRefPubMed Wein W, Brunke S, Khamene A, Callstrom MR, Navab N (2008) Automatic CT-ultrasound registration for diagnostic imaging and image-guided intervention. Med Image Anal 12:577–585CrossRefPubMed
21.
go back to reference Abi-Jaoudeh N, Kobeiter H, Xu S, Wood BJ (2013) Image fusion during vascular and nonvascular image-guided procedures. Tech Vasc Interv Radiol 16(3):168–176CrossRefPubMed Abi-Jaoudeh N, Kobeiter H, Xu S, Wood BJ (2013) Image fusion during vascular and nonvascular image-guided procedures. Tech Vasc Interv Radiol 16(3):168–176CrossRefPubMed
22.
go back to reference Yzet T, Bouzerar R, Allart J-D, Demuynck F, Legallais C, Robert B, Deramond H, Meyer M-E, Balédent O (2010) Hepatic vascular flow measurements by phase contrast mri and doppler echography: a comparative and reproducibility study. J Magn Reson Imaging 31(3):579–588CrossRefPubMed Yzet T, Bouzerar R, Allart J-D, Demuynck F, Legallais C, Robert B, Deramond H, Meyer M-E, Balédent O (2010) Hepatic vascular flow measurements by phase contrast mri and doppler echography: a comparative and reproducibility study. J Magn Reson Imaging 31(3):579–588CrossRefPubMed
23.
go back to reference Yzet T, Bouzerar R, Baledent O, Renard C, Lumbala DM, Nguyen-Khac E, Regimbeau JM, Deramond H, Meyer M-E (2010) Dynamic measurements of total hepatic blood flow with phase contrast mri. Eur J Radiol 73(1):119–124CrossRefPubMed Yzet T, Bouzerar R, Baledent O, Renard C, Lumbala DM, Nguyen-Khac E, Regimbeau JM, Deramond H, Meyer M-E (2010) Dynamic measurements of total hepatic blood flow with phase contrast mri. Eur J Radiol 73(1):119–124CrossRefPubMed
24.
go back to reference Roldán-Alzate A, Frydrychowicz A, Niespodzany E, Landgraf BR, Johnson KM, Wieben O, Reeder SB (2013) In vivo validation of 4D flow MRI for assessing the hemodynamics of portal hypertension. J Magn Reson Imaging 37(5):1100–1108CrossRefPubMed Roldán-Alzate A, Frydrychowicz A, Niespodzany E, Landgraf BR, Johnson KM, Wieben O, Reeder SB (2013) In vivo validation of 4D flow MRI for assessing the hemodynamics of portal hypertension. J Magn Reson Imaging 37(5):1100–1108CrossRefPubMed
25.
go back to reference Berzigotti A, Reverter E, Garcia-Criado A, Abraldes JG, Cerini F, Garcia-Pagan JC, Bosch J (2013) Reliability of the estimation of total hepatic blood flow by doppler ultrasound in patients with cirrhotic portal hypertension. J Hepatol 59(4):717–722CrossRefPubMed Berzigotti A, Reverter E, Garcia-Criado A, Abraldes JG, Cerini F, Garcia-Pagan JC, Bosch J (2013) Reliability of the estimation of total hepatic blood flow by doppler ultrasound in patients with cirrhotic portal hypertension. J Hepatol 59(4):717–722CrossRefPubMed
26.
go back to reference Bowdle A (2014) Vascular complications of central venous catheter placement: evidence-based methods for prevention and treatment. J Cardiothorac Vasc Anesth 28:358–368CrossRefPubMed Bowdle A (2014) Vascular complications of central venous catheter placement: evidence-based methods for prevention and treatment. J Cardiothorac Vasc Anesth 28:358–368CrossRefPubMed
27.
go back to reference Pratschke S, Meimarakis G, Mayr S, Graeb C, Rentsch M, Zachoval R, Bruns CJ, Kleespies A, Jauch K-W, Loehe F, Angele MK (2011) Arterial bloof flow predicts graft survival in liver transplant patients. Liver Transpl 17:436–445CrossRefPubMed Pratschke S, Meimarakis G, Mayr S, Graeb C, Rentsch M, Zachoval R, Bruns CJ, Kleespies A, Jauch K-W, Loehe F, Angele MK (2011) Arterial bloof flow predicts graft survival in liver transplant patients. Liver Transpl 17:436–445CrossRefPubMed
Metadata
Title
Geometric modeling of hepatic arteries in 3D ultrasound with unsupervised MRA fusion during liver interventions
Authors
Maxime Gérard
François Michaud
Alexandre Bigot
An Tang
Gilles Soulez
Samuel Kadoury
Publication date
07-03-2017
Publisher
Springer International Publishing
Published in
International Journal of Computer Assisted Radiology and Surgery / Issue 6/2017
Print ISSN: 1861-6410
Electronic ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-017-1550-4

Other articles of this Issue 6/2017

International Journal of Computer Assisted Radiology and Surgery 6/2017 Go to the issue