Skip to main content
Top
Published in: Journal of Materials Science: Materials in Electronics 20/2021

13-09-2021

Implementation of quartz crystal microbalance with polystyrene layer modification for bovine serum albumin adsorption

Authors: Zhangliang Xu, Zhengqi He

Published in: Journal of Materials Science: Materials in Electronics | Issue 20/2021

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Quartz crystal microbalance (QCM) sensor and bioactive-modified thin films of polystyrene (PS) have been successfully and respectively fabricated using resistance evaporation technique. The films’ quality, bovine serum albumin (BSA) adsorption characteristic, and sensor performance were investigated. Firstly, the aluminum and silver layers were, respectively, sputtered on the At-cut quartz to form QCM sensors and characterized by atomic force microscopy. The aluminum layer exhibits much greater roughness than silver layer. The QCM sensor coated with silver electrode layer of 300 nm exhibits the resonance frequency around 10 MHz and more superior Q-factor around 8000. Then, the morphology of the deposited PS membranes were analyzed by positive fluorescence microscope, attenuated total reflectance Fourier-transform infrared spectroscopy, X-ray photoelectron spectroscopy, and water contact angle methods. The island-like PS membranes were achieved and used as sensitive layer for BSA adsorption. A ~ 186 Hz drop in the PS-based QCM sensor resonance frequency was observed when the sensor exposed to the BSA solution that dissolved in pure phosphate buffer saline. Finally, the QCM sensor has good linear sensitivity of ~ 87 Hz/(100 μg/mL) to different BSA concentrations from 50 μg/mL to 500 μg/mL.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference A. Arnau, A review of interface electronic systems for AT-cut quartz crystal microbalance applications in liquids. Sensors 8(1), 370–411 (2008)CrossRef A. Arnau, A review of interface electronic systems for AT-cut quartz crystal microbalance applications in liquids. Sensors 8(1), 370–411 (2008)CrossRef
2.
go back to reference Y. Nariman, T. Nathalie, Probing the interaction between nanoparticles and lipid membranes by quartz crystal microbalance with dissipation monitoring. Front. Chem. 4, 46 (2016) Y. Nariman, T. Nathalie, Probing the interaction between nanoparticles and lipid membranes by quartz crystal microbalance with dissipation monitoring. Front. Chem. 4, 46 (2016)
3.
go back to reference L. Palmqvist, K. Holmberg, Dispersant adsorption and viscoelasticity of alumina suspensions measured by quartz crystal microbalance with dissipation monitoring and in situ dynamic rheology. Langmuir 24(18), 9989–9996 (2008)CrossRef L. Palmqvist, K. Holmberg, Dispersant adsorption and viscoelasticity of alumina suspensions measured by quartz crystal microbalance with dissipation monitoring and in situ dynamic rheology. Langmuir 24(18), 9989–9996 (2008)CrossRef
4.
go back to reference L. Gan, M. Zhou, D. Yang, X. Qiu, Aggregation and adsorption behaviors of carboxymethylated lignin (CML) in aqueous solution. Holzforschung 67(4), 379–385 (2013)CrossRef L. Gan, M. Zhou, D. Yang, X. Qiu, Aggregation and adsorption behaviors of carboxymethylated lignin (CML) in aqueous solution. Holzforschung 67(4), 379–385 (2013)CrossRef
5.
go back to reference N.L. Hong, W. Yu, Y.Y. Xue, W.M. Zeng, J.H. Huang, W.Q. Xie, X.Q. Qiu, Y. Li, A novel and highly efficient polymerization of sulfomethylated alkaline lignins via alkyl chain cross-linking method. Holzforschung 70(4), 297–304 (2016)CrossRef N.L. Hong, W. Yu, Y.Y. Xue, W.M. Zeng, J.H. Huang, W.Q. Xie, X.Q. Qiu, Y. Li, A novel and highly efficient polymerization of sulfomethylated alkaline lignins via alkyl chain cross-linking method. Holzforschung 70(4), 297–304 (2016)CrossRef
6.
go back to reference N.L. Hong, X.Q. Qiu, Structure-adsorption behavior-dispersion property relationship of alkyl chain cross-linked lignosulfonate with different molecular weights. ACS Omega 5(10), 4836–4843 (2020)CrossRef N.L. Hong, X.Q. Qiu, Structure-adsorption behavior-dispersion property relationship of alkyl chain cross-linked lignosulfonate with different molecular weights. ACS Omega 5(10), 4836–4843 (2020)CrossRef
7.
go back to reference A.W. Lu, A. Czanderna, Townshend, applications of piezoelectric quartz crystal microbalances. Anal. Chim. Acta 199(1), 279–279 (1987)CrossRef A.W. Lu, A. Czanderna, Townshend, applications of piezoelectric quartz crystal microbalances. Anal. Chim. Acta 199(1), 279–279 (1987)CrossRef
8.
go back to reference H. Aizawa, S.I. Kusakari, K. Yamada, K. Noda, H. Habe, Development of organic gas sensor using quartz crystal microbalance coated with plasma-polymerized films. Sens. Mater. 32(3), 1123–1131 (2020) H. Aizawa, S.I. Kusakari, K. Yamada, K. Noda, H. Habe, Development of organic gas sensor using quartz crystal microbalance coated with plasma-polymerized films. Sens. Mater. 32(3), 1123–1131 (2020)
9.
go back to reference P.L. Konash, G.J. Bastiaans, Piezoelectric crystals as detectors in liquid chromatography. Anal. Chem. 52(12), 1929–1931 (1980)CrossRef P.L. Konash, G.J. Bastiaans, Piezoelectric crystals as detectors in liquid chromatography. Anal. Chem. 52(12), 1929–1931 (1980)CrossRef
10.
go back to reference K.K. Kanazawa, J.G. Gordon II., The oscillation frequency of a quartz resonator in contact with liquid. Anal. Chim. Acta 175, 99–105 (1985)CrossRef K.K. Kanazawa, J.G. Gordon II., The oscillation frequency of a quartz resonator in contact with liquid. Anal. Chim. Acta 175, 99–105 (1985)CrossRef
11.
go back to reference H. Eun, Y. Umezawa, Quartz crystal microbalance for selenite sensing based on growth of cadmium selenite crystals immobilized on a monolayer of phosphorylated 11-mercapto-1-undecanol. Microchim. Acta 131(3), 177–185 (1999)CrossRef H. Eun, Y. Umezawa, Quartz crystal microbalance for selenite sensing based on growth of cadmium selenite crystals immobilized on a monolayer of phosphorylated 11-mercapto-1-undecanol. Microchim. Acta 131(3), 177–185 (1999)CrossRef
12.
go back to reference M. Michalzik, R. Wilke, S. Buettgenbach, Miniaturized QCM-based flow system for immunosensor application in liquid. Sens. Actuators B Chem. 111(11), 410–415 (2005)CrossRef M. Michalzik, R. Wilke, S. Buettgenbach, Miniaturized QCM-based flow system for immunosensor application in liquid. Sens. Actuators B Chem. 111(11), 410–415 (2005)CrossRef
13.
go back to reference E.E. María, S. Sánchez, A. Jiménez, Virgin olive oil sensory evaluation by an artificial olfactory system, based on quartz crystal microbalance (QCM) sensors. Sens. Actuators B Chem. 147(1), 159–164 (2010)CrossRef E.E. María, S. Sánchez, A. Jiménez, Virgin olive oil sensory evaluation by an artificial olfactory system, based on quartz crystal microbalance (QCM) sensors. Sens. Actuators B Chem. 147(1), 159–164 (2010)CrossRef
14.
go back to reference D.J. Li, J.P. Wang, R.H. Wang, Y.B. Li, D. Abi-Ghanem, L. Berghman, B. Hargis, H.G. Lu, A nanobeads amplified QCM immunosensor for the detection of avian influenza virus H5N1. Biosens. Bioelectron. 26(10), 4146–4154 (2011)CrossRef D.J. Li, J.P. Wang, R.H. Wang, Y.B. Li, D. Abi-Ghanem, L. Berghman, B. Hargis, H.G. Lu, A nanobeads amplified QCM immunosensor for the detection of avian influenza virus H5N1. Biosens. Bioelectron. 26(10), 4146–4154 (2011)CrossRef
15.
go back to reference M.K. Mustafa, A. Nabok, D. Parkinson, I.E. Tothill, A. Tsargorodskaya, Detection of β-amyloid peptide (1–16) and amyloid precursor protein (APP770) using spectroscopic ellipsometry and QCM techniques: A step forward towards Alzheimers disease diagnostics. Biosens. Bioelectron. 26(4), 1332–1336 (2011)CrossRef M.K. Mustafa, A. Nabok, D. Parkinson, I.E. Tothill, A. Tsargorodskaya, Detection of β-amyloid peptide (1–16) and amyloid precursor protein (APP770) using spectroscopic ellipsometry and QCM techniques: A step forward towards Alzheimers disease diagnostics. Biosens. Bioelectron. 26(4), 1332–1336 (2011)CrossRef
16.
go back to reference N. Kim, S.H. Son, C.T. Kim, Y.J. Cho, C.J. Kim, W.Y. Kim, Direct-binding quartz crystal microbalance immunosensor to detect carp metallothionein. Sens. Actuators B Chem. 157(2), 627–634 (2011)CrossRef N. Kim, S.H. Son, C.T. Kim, Y.J. Cho, C.J. Kim, W.Y. Kim, Direct-binding quartz crystal microbalance immunosensor to detect carp metallothionein. Sens. Actuators B Chem. 157(2), 627–634 (2011)CrossRef
17.
go back to reference Y.F. Wu, G.Y. Li, Y.Z. Hong, X.L. Zhao, P.I. Reyes, Y.C. Lu, Rapid and dynamic detection of antimicrobial treatment response using spectral amplitude modulation in MZO nanostructure-modified quartz crystal microbalance. J. Microbiol. Meth. 178, 106071 (2020)CrossRef Y.F. Wu, G.Y. Li, Y.Z. Hong, X.L. Zhao, P.I. Reyes, Y.C. Lu, Rapid and dynamic detection of antimicrobial treatment response using spectral amplitude modulation in MZO nanostructure-modified quartz crystal microbalance. J. Microbiol. Meth. 178, 106071 (2020)CrossRef
18.
go back to reference H.J. Lim, T. Saha, B.T. Tey, W.S. Tan, C.W. Ooi, Quartz crystal microbalance-based biosensors as rapid diagnostic devices for infectious diseases. Biosens. Bioelectron. 168, 112513 (2020)CrossRef H.J. Lim, T. Saha, B.T. Tey, W.S. Tan, C.W. Ooi, Quartz crystal microbalance-based biosensors as rapid diagnostic devices for infectious diseases. Biosens. Bioelectron. 168, 112513 (2020)CrossRef
19.
go back to reference M.Z. Atashbar, B. Bejcek, A. Vijh, S. Singamaneni, QCM biosensor with ultra thin polymer film. Sens. Actuators B Chem. 107(2), 945–951 (2005)CrossRef M.Z. Atashbar, B. Bejcek, A. Vijh, S. Singamaneni, QCM biosensor with ultra thin polymer film. Sens. Actuators B Chem. 107(2), 945–951 (2005)CrossRef
20.
go back to reference Z.C. Pei, H. Anderson, T. Aastrup, O. Ramstrom, Study of real-time lectin-carbohydrate interactions on the surface of a quartz crystal microbalance. Biosens. Bioelectron. 21(1), 60–66 (2005)CrossRef Z.C. Pei, H. Anderson, T. Aastrup, O. Ramstrom, Study of real-time lectin-carbohydrate interactions on the surface of a quartz crystal microbalance. Biosens. Bioelectron. 21(1), 60–66 (2005)CrossRef
21.
go back to reference S.P. Sakti, F. Wahyuni, U.P. Juswono, Development of QCM immunosensor with small sample solution for detection of MMP-3 antibody. Sens. Transducers 149(2), 143–148 (2013) S.P. Sakti, F. Wahyuni, U.P. Juswono, Development of QCM immunosensor with small sample solution for detection of MMP-3 antibody. Sens. Transducers 149(2), 143–148 (2013)
22.
go back to reference B. Pejcic, C. Barton, E. Crooke, P. Eadington, E. Jee, A. Ross, Hydrocarbon sensing. Part 1: some important aspects about sensitivity of a polymer-coated quartz crystal microbalance in the aqueous phase. Sens. Actuators B Chem. 135(2), 436–443 (2009)CrossRef B. Pejcic, C. Barton, E. Crooke, P. Eadington, E. Jee, A. Ross, Hydrocarbon sensing. Part 1: some important aspects about sensitivity of a polymer-coated quartz crystal microbalance in the aqueous phase. Sens. Actuators B Chem. 135(2), 436–443 (2009)CrossRef
23.
go back to reference J. Kobayashi, Y. Arisaka, N. Yui, Y. Akiyama, M. Yamato, T. Okano, Effect of temperature changes on serum protein adsorption on thermoresponsive cell-culture surfaces monitored by a quartz crystal microbalance with dissipation. Int. J. Mol. Sci. 19(5), 1516 (2018)CrossRef J. Kobayashi, Y. Arisaka, N. Yui, Y. Akiyama, M. Yamato, T. Okano, Effect of temperature changes on serum protein adsorption on thermoresponsive cell-culture surfaces monitored by a quartz crystal microbalance with dissipation. Int. J. Mol. Sci. 19(5), 1516 (2018)CrossRef
24.
go back to reference S.P. Sakti, L. Amaliya, N.F. Khusnah, M. Masruroh, Effect of UV radiation duration and molecular weight to hydrophobicity and surface roughness of polystyrene coating on QCM sensor. J. Teknol 79(3), 61–67 (2017) S.P. Sakti, L. Amaliya, N.F. Khusnah, M. Masruroh, Effect of UV radiation duration and molecular weight to hydrophobicity and surface roughness of polystyrene coating on QCM sensor. J. Teknol 79(3), 61–67 (2017)
25.
go back to reference S.P. Sakti, E. Rahmawati, F. Robiandi, Solvent effect on polystyrene surface roughness on top of QCM sensor. AIP Conf. Proc. 1719, 030017 (2016)CrossRef S.P. Sakti, E. Rahmawati, F. Robiandi, Solvent effect on polystyrene surface roughness on top of QCM sensor. AIP Conf. Proc. 1719, 030017 (2016)CrossRef
26.
go back to reference M. Sun, B. Ding, J.Y. Yu, Sensitive metal ion sensors based on fibrous polystyrene membranes modified by polyethyleneimine. RSC Adv. 2(4), 1373–1378 (2012)CrossRef M. Sun, B. Ding, J.Y. Yu, Sensitive metal ion sensors based on fibrous polystyrene membranes modified by polyethyleneimine. RSC Adv. 2(4), 1373–1378 (2012)CrossRef
27.
go back to reference S.P. Sakti, C. Nur, S.P. Ayu, M.C. Padaga, Aulanni’am A, , Development of QCM biosensor with specific cow milk protein antibody for candidate milk adulteration detection. J. Sens. 2016, 1807647 (2016)CrossRef S.P. Sakti, C. Nur, S.P. Ayu, M.C. Padaga, Aulanni’am A, , Development of QCM biosensor with specific cow milk protein antibody for candidate milk adulteration detection. J. Sens. 2016, 1807647 (2016)CrossRef
28.
go back to reference C. Turgut, G. Sinha, L. Mether, J. Lahtinen, K. Nordlund, M. Belmahi, P. Philipp, Experimental and numerical study of submonolayer sputter deposition of polystyrene fragments on silver for the storing matter technique. Anal. Chem. 86, 11217–11225 (2014)CrossRef C. Turgut, G. Sinha, L. Mether, J. Lahtinen, K. Nordlund, M. Belmahi, P. Philipp, Experimental and numerical study of submonolayer sputter deposition of polystyrene fragments on silver for the storing matter technique. Anal. Chem. 86, 11217–11225 (2014)CrossRef
29.
go back to reference C. Turgut, T. Wirtz, M. Belmahi, P. Philipp, Fragmentation of polystyrene during sputter deposition in the storing matter instrument. Surf. Interface Anal. 46, 357–359 (2014)CrossRef C. Turgut, T. Wirtz, M. Belmahi, P. Philipp, Fragmentation of polystyrene during sputter deposition in the storing matter instrument. Surf. Interface Anal. 46, 357–359 (2014)CrossRef
30.
go back to reference S. Wehner, K. Wondraczek, D. Johannsmann, A. Bund, Roughness-induced acoustic second-harmonic generation during electrochemical metal deposition on the quartz-crystal microbalance. Langmuir 20(6), 2356–2360 (2004)CrossRef S. Wehner, K. Wondraczek, D. Johannsmann, A. Bund, Roughness-induced acoustic second-harmonic generation during electrochemical metal deposition on the quartz-crystal microbalance. Langmuir 20(6), 2356–2360 (2004)CrossRef
31.
go back to reference H.J. Janshoff, C. Galla, Steinem, the quartz-crystal microbalance in life science. Angew. Chem. Int. Ed. 39, 4004–4032 (2000)CrossRef H.J. Janshoff, C. Galla, Steinem, the quartz-crystal microbalance in life science. Angew. Chem. Int. Ed. 39, 4004–4032 (2000)CrossRef
32.
go back to reference Y. Josse, S.J. Lee, R.W. Martin, Cernosek, analysis of the radial dependence of mass sensitivity for modified-electrode quartz crystal resonators. Anal. Chem. 70(2), 237–247 (1998)CrossRef Y. Josse, S.J. Lee, R.W. Martin, Cernosek, analysis of the radial dependence of mass sensitivity for modified-electrode quartz crystal resonators. Anal. Chem. 70(2), 237–247 (1998)CrossRef
33.
go back to reference B.K. Gan, M.M.M. Bilek, A. Kondyurin, K. Mizuno, D.R. Mckenzie, Etching and structural changes in nitrogen plasma immersion ion implanted polystyrene films. Nuclear Instrum. Methods Phys. Res. Sect. B 247(2), 254–260 (2006)CrossRef B.K. Gan, M.M.M. Bilek, A. Kondyurin, K. Mizuno, D.R. Mckenzie, Etching and structural changes in nitrogen plasma immersion ion implanted polystyrene films. Nuclear Instrum. Methods Phys. Res. Sect. B 247(2), 254–260 (2006)CrossRef
34.
go back to reference D.M. Bubb, M.R. Papantonakis, J.S. Horwitz, R.F. Haglund, B. Toftmann, R.A. Mcgill, D.B. Chrisey, Vapor deposition of polystyrene thin films by intense laser vibrational excitation. Chem. Phys. Lett. 352, 135–139 (2002)CrossRef D.M. Bubb, M.R. Papantonakis, J.S. Horwitz, R.F. Haglund, B. Toftmann, R.A. Mcgill, D.B. Chrisey, Vapor deposition of polystyrene thin films by intense laser vibrational excitation. Chem. Phys. Lett. 352, 135–139 (2002)CrossRef
35.
go back to reference A.J. Choudhury, H. Kakati, A.R. Pal, D.S. Patil, J. Chutia, Synthesis and characterization of plasma polymerized styrene films by rf discharge. J Phys: Conf Ser. 208(1), 012104 (2010) A.J. Choudhury, H. Kakati, A.R. Pal, D.S. Patil, J. Chutia, Synthesis and characterization of plasma polymerized styrene films by rf discharge. J Phys: Conf Ser. 208(1), 012104 (2010)
36.
go back to reference D. Merche, C. Poleunis, P. Bertrand, M. Sferrazza, F. Reniers, Synthesis of polystyrene thin films by means of an atmospheric-pressure plasma torch and a dielectric barrier discharge. IEEE Trans. Plasma Sci. 37(6), 951–960 (2009)CrossRef D. Merche, C. Poleunis, P. Bertrand, M. Sferrazza, F. Reniers, Synthesis of polystyrene thin films by means of an atmospheric-pressure plasma torch and a dielectric barrier discharge. IEEE Trans. Plasma Sci. 37(6), 951–960 (2009)CrossRef
Metadata
Title
Implementation of quartz crystal microbalance with polystyrene layer modification for bovine serum albumin adsorption
Authors
Zhangliang Xu
Zhengqi He
Publication date
13-09-2021
Publisher
Springer US
Published in
Journal of Materials Science: Materials in Electronics / Issue 20/2021
Print ISSN: 0957-4522
Electronic ISSN: 1573-482X
DOI
https://doi.org/10.1007/s10854-021-06985-1

Other articles of this Issue 20/2021