Skip to main content
Top
Published in: International Journal of Computer Assisted Radiology and Surgery 5/2017

06-02-2017 | Original Article

Normal model construction for statistical image analysis of torso FDG-PET images based on anatomical standardization by CT images from FDG-PET/CT devices

Authors: Kenshiro Takeda, Takeshi Hara, Xiangrong Zhou, Tetsuro Katafuchi, Masaya Kato, Satoshi Ito, Keiichi Ishihara, Shinichiro Kumita, Hiroshi Fujita

Published in: International Journal of Computer Assisted Radiology and Surgery | Issue 5/2017

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Purpose

A better understanding of the standardized uptake value (SUV) ranges of fludeoxyglucose positron emission tomography (FDG-PET) is crucial for radiologists. We have developed a statistical image analysis method for FDG-PET imaging of the torso, based on comparisons with normal data. The purpose of this study was to verify the accuracy of the normal model and usefulness of the statistical image analysis method by using typical cancer cases in the liver, lungs, and abdomen.

Methods

Our study and the data collection (49 normal and 34 abnormal cases, in terms of PET/CT findings) were approved by the institutional review board. Our scheme consisted of the following steps: (1) normal model construction, (2) anatomical standardization of patient images, and (3) Z-score calculation to show the results of the statistical image analysis. To validate the Z-score index, we sampled 3603 and 1270 voxels in normal organs and abnormal regions, respectively, from the liver, lungs, and the abdomen. We then obtained the SUV and Z-score for each region. A receiver operating characteristics (ROC) analysis-based method was performed to evaluate the discrimination performances of the SUV and Z-score.

Results

The discrimination performances of the SUV and Z-score for the objective regions of interest (ROIs) were evaluated by the areas under the ROC curves (AUCs). As a result of the ROC analysis and statistical tests, all AUCs were found to be larger than 0.98. When the ROIs in the objective regions were combined, the mean AUCs of the Z-score and SUV were 0.99 and 0.98, respectively, the difference being statistically significant (\(p < 0.001\)).

Conclusions

The results suggested the possibility of applying a quantitative image reading method for torso FDG-PET imaging. Furthermore, a combination of the SUV and Z-score may provide increased accuracy of the determination methods, such as computer-aided detection and diagnosis.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Keyes JW Jr (1995) SUV: standardized uptake or silly uptake value. J Nucl Med 36:1836–1839PubMed Keyes JW Jr (1995) SUV: standardized uptake or silly uptake value. J Nucl Med 36:1836–1839PubMed
3.
go back to reference Ishii K, Kono AK, Sasaki H, Miyamoto N, Fukuda T, Sakamoto S, Mori E (2006) Fully automatic diagnostic system for early- and late-onset mild Alzheimer’s disease using FDG PET and 3D-SSP. Eur J Nucl Med Mol Imaging 33:575–583CrossRefPubMed Ishii K, Kono AK, Sasaki H, Miyamoto N, Fukuda T, Sakamoto S, Mori E (2006) Fully automatic diagnostic system for early- and late-onset mild Alzheimer’s disease using FDG PET and 3D-SSP. Eur J Nucl Med Mol Imaging 33:575–583CrossRefPubMed
4.
go back to reference Mito Y, Yoshida K, Yabe I, Makino K, Hirotani M, Tashiro K, Kikuchi S, Sasaki H (2005) Brain 3D-SSP SPECT analysis in dementia with Lewy bodies, Parkinson’s disease with and without dementia, and Alzheimer’s disease. Clin Neurol Neurosurg 107:396–400CrossRefPubMed Mito Y, Yoshida K, Yabe I, Makino K, Hirotani M, Tashiro K, Kikuchi S, Sasaki H (2005) Brain 3D-SSP SPECT analysis in dementia with Lewy bodies, Parkinson’s disease with and without dementia, and Alzheimer’s disease. Clin Neurol Neurosurg 107:396–400CrossRefPubMed
5.
go back to reference Friston KJ, Ashburner JT, Kiebel SJ, Nichols TE, Penny WD (2007) Statistical parametric mapping: the analysis of functional brain images. Academic Press, LondonCrossRef Friston KJ, Ashburner JT, Kiebel SJ, Nichols TE, Penny WD (2007) Statistical parametric mapping: the analysis of functional brain images. Academic Press, LondonCrossRef
6.
go back to reference McNally KA, Paige AL, Varghese G, Zhang H, Novotny EJ, Spencer SS, Zubal IG, Blumenfeld H (2005) Localizing value of ictal-interictal SPECT analyzed by SPM (ISAS). Epilepsia 46:1450–1464CrossRefPubMed McNally KA, Paige AL, Varghese G, Zhang H, Novotny EJ, Spencer SS, Zubal IG, Blumenfeld H (2005) Localizing value of ictal-interictal SPECT analyzed by SPM (ISAS). Epilepsia 46:1450–1464CrossRefPubMed
7.
go back to reference Minoshima S, Giordani B, Berent S, Frey K, Foster N, Kuhl D (1997) Metabolic reduction in the posterior cingulate cortex in very early Alzheimer’s disease. Ann Neurol 42:85–94 Minoshima S, Giordani B, Berent S, Frey K, Foster N, Kuhl D (1997) Metabolic reduction in the posterior cingulate cortex in very early Alzheimer’s disease. Ann Neurol 42:85–94
8.
go back to reference Hara T, Kobayashi T, Ito S, Zhou X, Katafuchi T, Fujita H (2015) Quantitative analysis of torso FDG-PET scans by using anatomical standardization of normal cases from thorough physical examinations. PLoS ONE 10(5):e0125713 Hara T, Kobayashi T, Ito S, Zhou X, Katafuchi T, Fujita H (2015) Quantitative analysis of torso FDG-PET scans by using anatomical standardization of normal cases from thorough physical examinations. PLoS ONE 10(5):e0125713
9.
go back to reference Shimizu Y, Hara T, Fukuoka D, Zhou X, Muramatsu C, Ito S, Hakozaki K, Kumita S, Ishihara K, Katafuchi T, Fujita H (2013) Temporal subtraction system on torso FDG-PET scans based on statistical image analysis. Proc SPIE Med Imaging 8670:86703F-1–86703F-6CrossRef Shimizu Y, Hara T, Fukuoka D, Zhou X, Muramatsu C, Ito S, Hakozaki K, Kumita S, Ishihara K, Katafuchi T, Fujita H (2013) Temporal subtraction system on torso FDG-PET scans based on statistical image analysis. Proc SPIE Med Imaging 8670:86703F-1–86703F-6CrossRef
10.
go back to reference Bookstein FL (1989) Principal warps: thin-plate splines and the decomposition of deformation. IEEE Trans Pattern Anal Mach Intell 11:567–585CrossRef Bookstein FL (1989) Principal warps: thin-plate splines and the decomposition of deformation. IEEE Trans Pattern Anal Mach Intell 11:567–585CrossRef
12.
go back to reference Faul F, Erdfelder E, Lang AG, Buchner A (2007) G*Power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences. Behav Res Methods 39(2):175–191CrossRefPubMed Faul F, Erdfelder E, Lang AG, Buchner A (2007) G*Power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences. Behav Res Methods 39(2):175–191CrossRefPubMed
13.
go back to reference Faul F, Erdfelder E, Buchner A, Lang AG (2009) Statistical power analyses using G*Power 3.1: tests for correlation and regression analyses. Behav Res Methods 41(4):1149–1160CrossRefPubMed Faul F, Erdfelder E, Buchner A, Lang AG (2009) Statistical power analyses using G*Power 3.1: tests for correlation and regression analyses. Behav Res Methods 41(4):1149–1160CrossRefPubMed
14.
go back to reference Zhou X, Yamaguchi S, Zhou X, Chen H, Hara T, Yokoyama R, Kanematsu M, Fujita H (2013) Automatic organ localizations on 3D CT images by using majority-voting of multiple 2D detections based on local binary patterns and Haar-like features. Proc SPIE Med Imaging 8670:86703A-1–86703A-7CrossRef Zhou X, Yamaguchi S, Zhou X, Chen H, Hara T, Yokoyama R, Kanematsu M, Fujita H (2013) Automatic organ localizations on 3D CT images by using majority-voting of multiple 2D detections based on local binary patterns and Haar-like features. Proc SPIE Med Imaging 8670:86703A-1–86703A-7CrossRef
15.
go back to reference Zhou X, Xu R, Hara T, Hirano Y, Yokoyama R, Kanematsu M, Hoshi H, Kido S, Fujita H (2014) Development and evaluation of statistical shape modeling for principal inner organs on torso CT images. Radiol Phys Technol 7:277–283CrossRefPubMed Zhou X, Xu R, Hara T, Hirano Y, Yokoyama R, Kanematsu M, Hoshi H, Kido S, Fujita H (2014) Development and evaluation of statistical shape modeling for principal inner organs on torso CT images. Radiol Phys Technol 7:277–283CrossRefPubMed
Metadata
Title
Normal model construction for statistical image analysis of torso FDG-PET images based on anatomical standardization by CT images from FDG-PET/CT devices
Authors
Kenshiro Takeda
Takeshi Hara
Xiangrong Zhou
Tetsuro Katafuchi
Masaya Kato
Satoshi Ito
Keiichi Ishihara
Shinichiro Kumita
Hiroshi Fujita
Publication date
06-02-2017
Publisher
Springer International Publishing
Published in
International Journal of Computer Assisted Radiology and Surgery / Issue 5/2017
Print ISSN: 1861-6410
Electronic ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-017-1526-4

Other articles of this Issue 5/2017

International Journal of Computer Assisted Radiology and Surgery 5/2017 Go to the issue

Premium Partner