Abstract

Detecting catheter resistance during surgery is an important aspect of robotic interventional surgery. This haptic feedback can improve doctors’ sense of realism, and therefore, the safety of the procedure. The resistance to the catheter or guidewire is the only basis for providing doctors with haptic feedback, and is also an important parameter in surgical safety strategy design. In master–slave interventional robots, catheter resistance is measured by the slave side, specifically, the catheter or guidewire manipulator. Any of four problems may occur during catheter and guidewire resistance measurements: friction and slipping, bending, damage to the catheter, or damage to the guidewire. In this study, we designed a novel torque that nondestructively clamps the catheter or guidewire to prevent slippage and damage. We also developed a new catheter/guidewire manipulator that allows the catheter/guidewire’s movements and resistance measurements to occur coaxially, preventing the catheter/guidewire from bending during motion and measurement. All movable parts in the manipulator are connected by sliding rails to reduce errors caused by friction. The results of evaluation of haptic feedback using simulated surgery indicate that the operators provided with haptic feedback can significantly reduce the duration of an operation and the resulting impact force.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
go back to reference Dankelman J, Dobbelsteen JJVD, Breedveld P (2011) Current technology on minimally invasive surgery and interventional techniques. In: Proceedings of 2011 international conference on instrumentation control and automation, pp 12–15 Dankelman J, Dobbelsteen JJVD, Breedveld P (2011) Current technology on minimally invasive surgery and interventional techniques. In: Proceedings of 2011 international conference on instrumentation control and automation, pp 12–15
go back to reference Gelman D, Skanes AC, Tavallaei MA et al (2016) Design and evaluation of a catheter contact-force controller for cardiac ablation therapy. IEEE Trans Biomed Eng 63(11):2301–2307CrossRef Gelman D, Skanes AC, Tavallaei MA et al (2016) Design and evaluation of a catheter contact-force controller for cardiac ablation therapy. IEEE Trans Biomed Eng 63(11):2301–2307CrossRef
go back to reference Guo J, Guo S, Xiao N, Ma X, Yoshida S, Tamiya T, Kawanishi M (2012) A novel robotic catheter system with force and visual feedback for vascular interventional surgery. Int J Mechatron Autom 2(1):15–24CrossRef Guo J, Guo S, Xiao N, Ma X, Yoshida S, Tamiya T, Kawanishi M (2012) A novel robotic catheter system with force and visual feedback for vascular interventional surgery. Int J Mechatron Autom 2(1):15–24CrossRef
go back to reference Guo J, Guo S, Tamiya T, Hirata H, Ishihara H (2014) A virtual reality-based method of decreasing transmission time of visual feedback for a tele-operative robotic catheter operating system. Int J Med Robot Comput Assist Surg. https://doi.org/10.1002/rcs.1642 Guo J, Guo S, Tamiya T, Hirata H, Ishihara H (2014) A virtual reality-based method of decreasing transmission time of visual feedback for a tele-operative robotic catheter operating system. Int J Med Robot Comput Assist Surg. https://​doi.​org/​10.​1002/​rcs.​1642
go back to reference Ikeda S, Arai F, Fukuda T, Negoro M, Irie K, Takahashi I et al (2005) In vitro patient-tailored anatomical model of cerebral artery for evaluating medical robots and systems for intravascular neurosurgery. In: Proceedings of 2005 IEEE international conference on intelligent robots and systems, pp 1558–1563 Ikeda S, Arai F, Fukuda T, Negoro M, Irie K, Takahashi I et al (2005) In vitro patient-tailored anatomical model of cerebral artery for evaluating medical robots and systems for intravascular neurosurgery. In: Proceedings of 2005 IEEE international conference on intelligent robots and systems, pp 1558–1563
go back to reference Jayender J, Patel RV, Nikumb S (2009) Robot-assisted active catheter insertion: algorithms and experiments. Int J Robot Res (IJRR) 28(9):1101–1117CrossRef Jayender J, Patel RV, Nikumb S (2009) Robot-assisted active catheter insertion: algorithms and experiments. Int J Robot Res (IJRR) 28(9):1101–1117CrossRef
go back to reference Kesner SB, Howe RD (2011) Position control of motion compensation cardiac catheters. IEEE Trans Robot 27(6):1045–1055CrossRef Kesner SB, Howe RD (2011) Position control of motion compensation cardiac catheters. IEEE Trans Robot 27(6):1045–1055CrossRef
go back to reference Khan EM et al (2013) First experience with a novel robotic remote catheter system: Amigo™ mapping trial. J Interv Card Electrophysiol 37(2):121–129CrossRef Khan EM et al (2013) First experience with a novel robotic remote catheter system: Amigo™ mapping trial. J Interv Card Electrophysiol 37(2):121–129CrossRef
go back to reference Lock J, Laing G (2010) Quasistasic modeling of concentric tube robots with external loads. In: The proceedings of 2010 IEEE/RSJ international conference on intelligent robots and systems, pp 2325–2332 Lock J, Laing G (2010) Quasistasic modeling of concentric tube robots with external loads. In: The proceedings of 2010 IEEE/RSJ international conference on intelligent robots and systems, pp 2325–2332
go back to reference Ma X, Guo S, Xiao N, Guo J, Yoshida S, Tamiya T, Kawanishi M (2012) Development of a novel robotic catheter manipulating system with fuzzy PID control. Int J Intell Mechatron Robot (IJIMR) 2(2):58–77 Ma X, Guo S, Xiao N, Guo J, Yoshida S, Tamiya T, Kawanishi M (2012) Development of a novel robotic catheter manipulating system with fuzzy PID control. Int J Intell Mechatron Robot (IJIMR) 2(2):58–77
go back to reference Penning RS, Jung J, Borgstadt JA, Ferrier NJ, Zinn MR (2011) Towards closed loop control of a continuum robotic manipulator for medical applications. In: IEEE international conference on robotics and automation (ICRA), pp 4822–4827 Penning RS, Jung J, Borgstadt JA, Ferrier NJ, Zinn MR (2011) Towards closed loop control of a continuum robotic manipulator for medical applications. In: IEEE international conference on robotics and automation (ICRA), pp 4822–4827
go back to reference Saliba W, Reddy VY, Wazni O, Cummings JE et al (2008) Atrial fibrillation ablation using a robotic catheter remote control system: initial human experience and long-term follow-up results. J Am Coll Cardiol 51:2407–2411CrossRef Saliba W, Reddy VY, Wazni O, Cummings JE et al (2008) Atrial fibrillation ablation using a robotic catheter remote control system: initial human experience and long-term follow-up results. J Am Coll Cardiol 51:2407–2411CrossRef
go back to reference Thakur Y, Bax JS, Holdsworth DW, Drangova M (2011) Design and performance evaluation of a remote catheter navigation system. IEEE Trans Biomed Eng 56(7):1901–1908CrossRef Thakur Y, Bax JS, Holdsworth DW, Drangova M (2011) Design and performance evaluation of a remote catheter navigation system. IEEE Trans Biomed Eng 56(7):1901–1908CrossRef
go back to reference Xiao N, Guo S, Guo J, Xiao X, Tamiya T (2011) Development of a kind of robotic catheter manipulation system. In: Proceedings of 2011 IEEE international conference on robotics and biomimetics, pp 32–37 Xiao N, Guo S, Guo J, Xiao X, Tamiya T (2011) Development of a kind of robotic catheter manipulation system. In: Proceedings of 2011 IEEE international conference on robotics and biomimetics, pp 32–37
go back to reference Xiao N, Guo J, Guo S, Tamiya T (2012) A robotic catheter system with real-time force feedback and monitor. J Australas Phys Eng Sci Med 35(3):283–289CrossRef Xiao N, Guo J, Guo S, Tamiya T (2012) A robotic catheter system with real-time force feedback and monitor. J Australas Phys Eng Sci Med 35(3):283–289CrossRef
Metadata
Title
Online measuring and evaluation of guidewire inserting resistance for robotic interventional surgery systems
Authors
Yuan Wang
Shuxiang Guo
Nan Xiao
Youxiang Li
Yuhua Jiang
Publication date
03-02-2018
Publisher
Springer Berlin Heidelberg
Published in
Microsystem Technologies / Issue 8/2018
Print ISSN: 0946-7076
Electronic ISSN: 1432-1858
DOI
https://doi.org/10.1007/s00542-018-3750-4

Other articles of this Issue 8/2018

Microsystem Technologies 8/2018 Go to the issue